TOOLS AND INSTRUMENTS MANNIX INSTRUMENTS DELUXE DIGITAL POCKET THERMOMETER DIGITAL ANEMOMETER F/C Switch Protective Cover Auto Power Off ON/OFF Switch Data Hold Simultaneous Display of Air Velocity and Temperature Recording Min., Max., and Average Measuring Average Air Velocity for Multi-points Pocket Clip C and F Switchable Drop Resistant Water Resistant P955 Hold Auto Power Off P952 2.5 Probe HDT303K RS232 Serial Output DCFM8901 Range: -40 to 300 F -40 to 150 C Battery: (1) LR44 Included AIRFLOW RANGE RESOLUTION ACCURACY 80-4900 ft/min. 1 ±2% 0.9-55.9 mph 0.1 ±2% 0.4-25 m/sec. 0.1 ±2% 1.4-90 km/hr. 0.1 ±2% TEMPERATURE -10 C to 50 C 0.1 ±0.6 C +14 F to 122 F 0.1 ±0.6 C SCREW DRIVER/TESTER with RED GLOW LED Self-Test Function AC Voltage Test: Contact: 70 to 250 VAC Non-Contact: 70 to 600 VAC Continuity Test Polarity Test Microwave Oven Leakage Detector Fuse Continuity Check Locates a Broken Wire P954 ST600LED DIGITAL SLING PSYCHROMETER Much More Accurate Than Outdated Analog Technology No Water Necessary No Twirling No Reading Charts Saves Time and Labor Instrument Displays: Temperature Humidity P953 Wet Bulb Dew Point SAM990DW 1103
TOOLS AND INSTRUMENTS MANNIX INSTRUMENTS (cont) TEMPERATURE/HUMIDITY PEN (THERMO-HYGROMETER) Color: Dark Grey Power Supply: One Button Cell Included (1 CR2032) Humidity Range: 5 to 95 RH Accuracy: 10 to 90 RH ±3% All Other Ranges ±5% Temperature: ±14 F to 122 F -10 C to 50 C Response Time: 80 Seconds Typical Simultaneous Display of Temperature and Humidity Memory (Min/Max) F/C Switch Pocket Sized DIGITAL HIGH TEMPERATURE THERMOMETER F/C Switch Clear Button Min/Max Function Plastic Sheath -14 F to 392 F (0 C to 200 C) P1201 P1200 PTH8708 DPT392F/C CFM AIRFLOW METER Can read up to 8 multi-point readings Hard carrying case Single hand airflow measurement with recessed service grip F and C Switchable Auto power off RS232 output SPECIFICATIONS Air Flow 80 to 6900 ft/m (0.4 to 35 m/sec) Resolution 0.1 Accuracy ±3%, ±2 F (±1 C) Temperature +14 to 122 F (-10 to 50 C) bpic1 DCFM8906 1104
BACHARACH SLING PSYCHROMETER TOOLS AND INSTRUMENTS Sling-type psychrometer determines percent relative humidity Built-in side rule calculator correlates wet and dry bulb temperatures to relative humidity Dual range (high and low temperature) scales for better resolution Thermometers telescope into handle for protection when not in use Built-in water reservoir holds sufficient water for several hours of testing P/N DESCRIPTION SCALE BAC-12-7011 Mercury Filled ( F) BAC-12-7012 Red Spirit Filled ( F) BAC-12-7013 Mercury Filled ( C) BAC-12-7043 Red Spirit Filled ( C) P825 BACHARACH GAS BURNER COMBUSTION TESTING KIT BAC-10-5217 This kit is one of the most economical means of testing for gas burner efficiency during installation or servicing. Included in this kit: Gas Service Calculator Fire Efficiency Finder High Efficiency Finder Carrying Case Moisture Absorb. Material Fyrite CO 2, 20% Filled Tyrite 0 2, 21% Filled Tempoint Thermometer 1000 F (6 Stem) Draftrite +.10 to.14 W Manometer 15 W 8.5 oz/in 2 Sampling Tube Attachment Spare Tube Tips (6) Monoxor Indicator.2% Carton of 12 CO Tubes P4295 BACHARACH GAS PRESSURE MANOMETER BAC-17-7002 This accurate and portable manometer is easy to read. Whether you are measuring or adjusting the pressure in gas lines, the valuable manometer can be used for all types of gas burning appliances. Besides using this instrument to measure and adjust the inlet and manifold pressure, it can also be used to determine filter resistance, fan efficiency, air velocity and statistic pressures. P4296 BACHARACH OIL BURNER COMBUSTION KIT BAC-10-5022 Like the Gas Burner Combustion Kit featured above, this kit is one of the most economical means of testing for oil burner efficiency during installation and servicing. Included in this kit: Fire Efficiency Finder Carrying Case (large) Moisture Absorb. Material Sampling Hose Assembly Fyrite CO 2 20% Filled Tempoint Therm. 1000 (6 Stem) MZF Draft, +.05 to -.25 W P4294 True Spot Smoke Tester 1105
TOOLS AND INSTRUMENTS BACHARACH MONOXER II CO ANALYZER WITH CASE BAC-19-8004 The continuous sampling instrument measures CO levels in combustion gas stack and ambient air levels quickly and accurately. Measures and displays low levels of CO between 0 and 2200 ppm (parts per million) in increments of 1 ppm Easy to hold with the multi-purpose strap Easy to read highly visible digital display with backlight Comes with probe and hose assembly for flu gas testing BACHARACH TRUE SPOT SMOKE TEST KIT BAC-21-7006 The True Spot smoke method has long been recognized as the accepted standard for oil burner smoke tests. The kit determines efficient combustion. The smoke test is an indispensable part of any oil burner service job as excess smoke is one of the most common causes of excessive fuel usage and expensive service requirements. P4298 P4297 BACHARACH FYRITE PRO 120 COMBUSTION ANALYZER WITCO BAC-24-8104 Increase your overall service productivity with the Fyrite Pro. Verify and adjust the efficiency of residential furnaces and appliances quickly and easily with the Fyrite Pro and all of these features: Simple to use. Turn unit on, select fuel, insert probe Each test can be recorded using an optional infrared printer (no wires) Hold key freezes the readings and transfers them to the infrared printer Tactile feedback from the instrument s keypad assures that the appropriate key has been activated Warranty offers worry free operation of instrument and sensors for up to two years after purchase A unique hand strap offers ease of handling Four alkaline batteries typically offer 24 hours of continuous operation Automatic power off ensure long battery life Optional protective rubber boot with magnet provides hands free operation Error message informs you of an instrument or sensor failure CE Certified P4293 1106
LEYBOLD INFICON D-TEK REFRIGERANT LEAK DETECTOR Equal sensitivity to CFC s, HCFC s, HFC s Flexible probe Variable-intensity audible signal Electrochemical heated-diode sensor TOOLS AND INSTRUMENTS 703-006-G1 (110V) 703-006-G2 (220V) P1198 TEK-MATE REFRIGERANT LEAK DETECTOR Sensitive to CFC s, HCFC s, HFC s (.4 oz./yr.) Automatic contamination adjustment Variable-intensity contamination alarm Operating Temperature Range: -20 F to 122 F, -27 C to 50 C 705-202-G1 P1199 WEY-TEK REFRIGERANT CHANGING SCALE Precision designed Lightweight Transfer all refrigerant by weight Measures in lbs. or kgs. High accuracy load cell won t drift 707-600-G1 1107
LEYBOLD INFICON (cont) GAS-MATE GASLEAK DETECTOR Sensitive to 5 ppm methane Also Detects natural gas, propane, butane, cyclopentane, ethane, ethanol, isobutane and ammonia Flexible probe Adjustable sensitivity Variable audio alarm for leak strength Auto zeroing for ignoring background gas levels TOOLS AND INSTRUMENTS 706-600-G1 CHARGING MODULE Charge/hold key Displays target charge & total refrigerant transferred Provides power to the scale 709-700-G1 YOKOGAWA H10G REFRIGERANT LEAK DETECTOR Detect all CFC, HFC and HFC Refrigerants Manual balance/zero adjust control AC powered Switchable sensitivity 25 years of proven experience Alarm Sensitivity SW Position R-134a R-12 Small 0.5 oz/yr. 0.1 oz/yr. Medium 1.0 oz/yr. 0.5 oz/yr. Large 5.0 oz/yr. 3.o oz.yr. P4282 H10G10 (12V) H10PM REFRIGERANT LEAK DETECTOR Detect all CFC, HFC and HFC Refrigerants Manual or automatic auto zero balance control Unique sensor calibration system CE Mark Pinpoints both small and large leaks Alarm Sensitivity SW Position R-134a R-12 Small 0.5 oz/yr. 0.1 oz/yr. Medium 1.0 oz/yr. 0.5 oz/yr. Large 5.0 oz/yr. 3.o oz.yr. P4283 H10PM-5 1108