Pamphlet A2000. TL\l. Free Float Steam Trap Series

Similar documents
Pure Performance For Steam Mains and Tracers

Pure Performance For Steam Mains and Tracers

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

TL\l DRAIN TRAP. , s. JA JAHR Series I GS. TATSU2 SS1VA/JAHRASeries. Pamphlet A

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

Our Know-How. Your Peace of Mind. Steam Solutions

Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

LIQUIDATOR UMT-TD Series Thermodynamic

STAINLESS STEEL PRODUCT GUIDE. Pamphlet M8012

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

THERMOSTATIC STEAM TRAPS

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

THERMODYNAMIC STEAM TRAPS

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

THERMODYNAMIC STEAM TRAPS

Steam Traps and Steam Specialties

STEAM TRAPS

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Liquid Drainers LIQUID DRAINERS

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

- Pamphlet A2404 TLV. ertrap a ic I Pump & Pump/Trap. GP Series GT Series

Pamphlet M AIR & DRAIN TRAPS. JA JAHR Series / G8 TATSU2 SS1VG / JAHRG Series

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS JH-B SERIES JH5RL-B JH5RH-B JH7RH-B JH7.

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

LIQUIDATOR 450 SERIES

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

INSTALLATION, OPERATION

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

INSTALLATION, OPERATION

Silhouette. Feedwater Heater. Boiler Feedwater

Blowdown Separator & Aftercoolers

UNIFIED FACILITIES GUIDE SPECIFICATIONS

THE THERMOSTATIC STEAM TRAP

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Pamphlet M2012 BALANCED PRESSURE THERMOSTATIC STEAM TRAPS

CD-33/CD-33S Controlled Disc Steam Traps

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Chapter 2.3: Steam System

Refrigerant Valves/Accessories

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

The right trap for the right application.

Disc Type Steam Trap TSD-42

THERMODYNAMIC STEAM TRAP

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Intelligent System Solutions Steam Air Hot Water

Inverted Bucket Steam Traps

Hoffman Specialty General Catalog

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

PIP PNE00004 Steam Trap Guidelines

Product Family Overview

Series 1140 and 1141 Temperature Regulators

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Hydrocarbon & Chemical Processing Solutions

PRODUCTS. Expansion Joints Fire Fighting. Flexible Metal Hoses. Equipments. Insulation Solutions. Steam. Valves. Level Control.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

INSTALLATION, OPERATION

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

Main Steam Vents. Hoffman Specialty Regulators. How to Select Steam Vents

Steam Condensing Heat Exchanger SR-3 / SR-8

Steam Injection Humidifiers for use with steam boilers PR0DUCT CATALOG

FT14 Ball Float Steam Trap (Screwed)

Spirax-Sarco Industrial Thermostatic Steam Traps

Economical and simplified solutions that offer quality and optimum steam trap service.

Bringing Energy Down to Earth

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Installation and Testing of Inverted Bucket Steam Traps Manual

STEAM CONSERVATION GUIDELINES

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

STAINLESS STEEL TRAP VALVE STATION

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Open the Door to Increased Productivity and Cost Efficiency

13-1. Temperature Regulator

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

SECTION SECTION DESIGN REQUIREMENTS

Why steam trap survey?

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

Transcription:

- Pamphlet A2000 TL\l Free Float Steam Trap Series

Free Float Steam Traps Revolutionizing Fluid Control Technology More than 40 years have passed since TUI introduced the free float concept to the steam industry. Since then, TUl's Free Float traps and other innovative technologies have enabled users to achieve exceptional performance in facility after facility worldwide. Free Float. Principle The failure of mechanical steam traps is related to their number of moving parts. TUI Free Float traps have only one moving part, the float. Compared to complex mechanical traps such as the inverted bucket with its fevers and hinges, TUI Free Float traps mean fewer failures and long service life. Precision-ground Spherical Float For most TUI Free Float trap models, a unique grinding process virtually eliminates the welding seam, finishing the float to be almost perfectly spherical. These floats have unmatched sealing performance with the valve seat to prevent steam loss, and they are designed for severe senice operation. Even at high pressures, they provide excellent durability and resistance to water hammer, ensuring long and reliable operation. Simple Is Best! Free Float technology manifests TUl's product philosophy.

The First Choice for Efficiency The Reasons are Simple 1 Efficiency The TUI Free Float adjusts quickly to changes in condensate flow, ensuring rapid discharge and maximum process efficiency. Unaffected by back pressure, the TUI Free Float is ideal wherever condensate is recovered. 4 Long Life The precision ground float provides an infinite number of contact surfaces with the orifice, ensuring little wear and long reliable fife. 2 Energy Conservation Orifice below "water level" and 3-point seating in some models prevent steam leakage. 5 Automatic Air Venting Automatic air venting discharges initial air so the equipment can be started up in the shortest possible time period. X-efement also vents air at near steam temperature, suitable for batch operation equipment. 3 Integral Strainer All internals are protected by an integral perforated stainless steel strainer screen.* * except JL and JI 0 Series FREE FLOAT OPERATION (X-elementJ 1 Start-up Discharge 2 Hot Condensate Discharge 3 Continuous Response 4 Complete Closure When trap is cool, the X-element contracts and valve port [AJ opens wide, continuously discharging initial air. As cold condensate enters the trap, the float rises to allow discharge of condensate from valve port (BJ and both air and condensate from valve port [AJ. Once all initial air and cold condensate have been discharged, hot condensate heats the X element and closes valve port [AJ before steam can escape. Condensate which simultaneously enters the trap continues to be discharged through valve port (BJ. Air or retained condensate entering the trap drop the temperature and contract the X-element. Valve port [AJ instantaneously opens to discharge both air and condensate. When higher temperature condensate follows, the X-element expands and closes valve port [AJ. ~~~,....::,Z B When condensate flow to the trap ceases, the float closes valve port (BJ which is always sealed below the water level. The upper section fills with steam, closing valve port [AJ. The trap is then completely sealed, preventing any steam leakage. 2

THE CHOICE IS TLV 's JX/JH-X/JH-B SERIES TO MAXIMIZE ALL OF THE REQUIREMENTS OF A PROCESS STEAM TRAP'S FUNCTION Functions Required of Traps Improved Heating Efficiency and Production Quality TUl's Free Float immediately adjusts the valve opening to perfectly match the amount of entering condensate. Condensate is continuously discharged, so no condensate backs up into equipment allowing process temperature to be maintained. The Optimal Air Vent for Any Application The JX and JH series offer a variety of air vents and venting devices to offer an optimized solution for any application. From rapid air venting to extremely high-pressure applications, TUI offers an air vent to fit even the most demanding needs. Integral Automatic Air Vent The JX and JH-X series steam traps operate stress-free and their X-element type automatic air vents provide for rapid removal of air and non-condensible gases at start-up and during normal operation. The JH-8 series features a bimetal type automatic air vent for durable high temperature service and rapid start-up. JX, JH-X Series Optional Venting Devices JH-8 Series Bi metal Other JH series steam traps can be optionally equipped with automatic LEX air venting capability. For Rotating Can service, a lock release valve (needle valve) or drilled air vent is available on many JX and JH-X steam traps.* J3X, JSX JX, JH-X Series JH Series <Common Features> Built-in Strainer These steam traps also feature an integral screen with large surface area to extend trouble-free operation. lnline Repairable JX, JH-X and JH-8 series steam traps are equipped with a removable cover to provide ease of inspection or maintenance without disturbing the piping. Lock Release Valve Drilled Vent Needle Valve External LEX *contact TUI for available models 3

JX Series Low-to-Med. Temperature Smal I-to-Large HVAC Application: Heat Exchanger JH-X Series Low-to-High TemJ:>erature Small-to-Large Heater Application: Heater Battery Cast iron, ductile cast iron, or stainless steel traps for low-to-medium pressure. J3S-X, JSS-X and J6S-X have stainless steel bodies, and 3-point seating design which ensures a steam-tight seal. Automatic X-element air vent for fast start-up and venting air at close-tosteam temperature. Externally removable orifice for inline inspection and repair. Internal float cover shields and protects float from water hammer. Reusable cover gaskets on J3X, JSX, J3S-X, JSS-X, J6S-X and J7X save maintenance costs. No. Description/Material Body/Cast Iron, Ductile Cast Iron, or Stainless Steel (?) Cover/Cast Iron, Ductile Cast Iron, or Stainless Steel (:?) Float/Stainless Steel (?) Screen/Stainless Steel GD CJ_) X-element/Stainless Steel Air Vent Seat/Stainless Steel Cast steel or stainless steel traps for low-to-high pressure. Automatic X-element air vent for fast start-up and venting air at close-to-steam temperature. On most models, 3-point seating design ensures a steam-tight seal. Externally removable orifice for inline inspection and repair. Internal float cover shields and protects float from water hammer. JH3S-X No. Description/Material Body/Cast Steel or Stainless Steel (?) Cover/Forged Carbon Steel or Stainless Steel (:?) Float/Stainless Steel (?) Screen/Stainless Steel GD X-element/Stainless Steel JHSRL-X Model J3X J3S-X** J5X JSS-X** J6S-X** J7X J7.2X J7.5X J8X JH3S-X** JHSSL-X** JHSRL-X** JH7RL-X** JHZ2R-X JHZSR-X JH7.5R X E** JHBR-X Connection* s F S,F s F S,F s S,F F F F S,W,F S,W S,W,F S,W,F F F F F Max. Allowable PMA (psig) 300 250 300 300 250 300 300 250 250 250 250 450 600 600 600 650 650 710 650 Max. Allowable Temperature TMA ('F) 428 428 428 428 428 428 428 428 428 428 428 662 800 800 800 800 800 800 800 * S = screwed, W = socket weld, F = flanged ** 3-point seating type 4

JH-B Series Low-to-High Small-to-Large Med.-to-High Temperature Heater Application: Heater Batteries Cast steel or stainless steel traps for low-to-high pressure. Automatic bimetal air vent for fast start-up. On most models, 3-point seating design ensures a steam-tight seal. Externally removable orifice for inline inspection and repair. Internal float cover shields and protects float from water hammer. JH7RL-B JH Series High High Tern erature Small-to-Large Dowtherm Application: Reactor for Dowtherm No. Description/Material Body/Cast Steel or Stainless Steel (?) Cover/Forged Carbon Steel or Stainless Steel 0) Float/Stainless Steel (?) Screen/Stainless Steel GD Bimetal Plate/- The JH7 RH-W is designed for high-pressure/high-temperature applications. The JH series can be specially fitted with a cover connection (such as for Downtherm applications) or an external air vent. A socket weld connection on the cover is available. Equipped with the same features as the JH-B series other than air venting. Cover Connection JHSRL-8 JH7RH-W (opbonal) fdowntherm is a trademark of Dow Chemical Co. J -W No. Description/Material (1) Body/Cast Steel (2) Cover/Forged Carbon Steel (3) Float/Stainless Steel (5) Screen/Stainless Steel JH7RH-W (opbonal) Model JH35-B** JHSSL-B** Connection* S,W,F S,W Max. Allowable PMA (psig) 450 650 Max. Allowable Temperature TMA ('F) 662 800 * S = screwed, W = socket weld, F = flanged ** 3-point seating type JHSSH-B** JHSRL-B** JHSRH-B** JH7RL-B** JH7RM-B** JH7RH-B** w S,W,F w W,F S,W,F w 925 650 I I 50 650 925 1740 800 800 800 800 800 800 5 JH7.2R-B JH7.SR-B JH7.SR &E* 1 JHBR-B JH7RH-W* F w w F w 650 650 710 650 1740 800 800 800 800 986

FS-SS-SH Series <Common Features> 3-point Seating These designs include "threepoint" seating of the float for seal-tight shutoff with no steam loss even under low condensate flow condition. Automatic Air Vent Integral bimetaf thermostatic air vent offers quick start-up and high resistance to water hammer. lnline Repairable Removable cover (except F53/5, and 553/5) to provide ease of inspection or maintenance without disturbing the piping. 3-point Seating FS Series TemJ:>erature Small Drip!Tracer Application: Jacketed Tracer Stainless steel trap with 2-boft universal connector facilitates installation and replacement. Universal flange permits correct installation in vertical and horizontal piping. All-welded maintenance-free trap body. FS3 ~---0, Model Connection* Max. Allowable PMA (psig) Max. Allowable Temperature TMA f F) * S = screwed, W = socket weld, F = flanged No. Description/Material Trap Body/Stainless Steel (?) Connector Body/Cast Stainless Steel 0) Float/Stainless Steel FS3 S,W,F FS5 S,W,F 345 450 752 752 6 No. Description/Material (?) Screen/Stainless Steel GD CJ_) Air Vent Strip/Bi metal Flange/Forged Carbon Steel FS5H S,W,F 650 800

SS Series Temperature Small Drip!Tracer Application: Tracer All stainless steel traps for medium pressure. SS 1 N/V* with removable cover for inspection and maintenance. SS3N/V*, SSSN/V*, SSSNH/VH* with all-welded SS3V maintenance-free body. Recommended for superheat. *"N" for horizontal installation, "V" for vertical installation SS1N SH Series High Superheat Small to Drip!Turbine Application: Main (Drip) No. Description/Material Body/Stainless Steel (?) Cover/Stainless Steel (:?) Valve Seat/- (4) Screen/Stainless Steel (?) Air Vent Strip/Bi metal GD Insulation Cover (optional, not shown) Cast steel traps for high pressure. Steam-tight, even under low condensate flow conditions. SH series traps offer horizontal installation, SHSVL offers vertical installation. Recommended for superheat. SS3N 0 SHSVL No. Description/Material Body/Cast Steel (?) Cover/Cast Steel or Forged Carbon Steel (:?) Float/Stainless Steel (?) Screen/Stainless Steel GD Air Vent Strip/Bi metal Connection* Model Max. Allowable PMA (psig) Max. Allowable Temperature TMA f F) SS I NUVL s 300 428 * S =screwed, W =socket weld, F = flanged ** SS3V: S only SSJNHNH SS3NN SS5NN SSSNHNH SH5VL s S, F** s S,W S,W 300 345 650 650 925 662 752 800 800 800 7 SH5NL SH5NH SH6NL SH6NH W,F W,F W,F w 925 I I 50 925 1500 800 800 800 800

Float Series J10,JH15 -to-high -to-high Temperature Extra Large Extra Large Heater Application: Large Re-Boiler Float Dynamic Principle: When a large quantity of condensate flows into the trap, the float rises immediately, opening the orifice wide. Condensate passes through the pilot orifice at a high velocity into the control chamber, where the pressure increases rapidly due to flashing condensate. The rapid expansion causes a force to be exerted on the piston, opening the large orifice instantly. As condensate discharges through the main orifice at high velocity, condensate in the equipment is induced into the trap for rapid discharge. JH15 JL Series Low-to- Temperature Extra Large Extra Large Heater Application: Large Re-Boiler No. Description/Material (1) Body/Cast Iron (J1 O) or Cast Steel (JH 15) (2) Cover/Cast Iron (J10) or Carbon Steel (JH15) (3) Float/Stainless Steel (4) Valve Seat/- (5) Air Vent/Stainless Steel Extremely durable, inline repairable cast iron or cast steel float trap for low-to-medium pressure. Automatic X-element air vent for fast start-up. Large double-seated valve with heat treat hardened working surfaces. Excellent resistance to water hammer. lnline inlet and outlet. JL14-X J10 No. Description/Material Body/Cast Iron (JL9X, JL 14-X) or Cast Steel (JLH9X, JLH14-X) (?) Cover/Cast Iron (JL9X, JL 14-X) or Cast Steel (JLH9X, JLH14-X) (:?) Float/Stainless Steel (4) Lever Unit/Stainless Steel (?) Trap Unit/Stainless Steel G;D X-element Air Vent/Stainless Steel Model JJO JHJ 5 JL9X JLH9X JLI 4-X JLHI 4-X Connection* F F S,F S,W,F S,F S,W,F Max. Allowable PMA (psig) 250 710 250 450 250 450 Max. Allowable Temperature TMA ( F) 428 800 428 752 428 752 * S = screwed, W = socket weld, F = flanged 8

election Guide Model Operating Maximum Maximum Operating Operating Air Body Range Temp Capacity Venting Material (psig) ( F) TMO (lb/h) JX ~ Vacuum Automatic Series -300 428 47,520 X-element Application Cast Iron, Heat Exchangers Ductile Iron Tank Heaters or Coils, Dryers Stainless Unit Heaters Steel Equipment Cast Steel or 464 40,000 Series -450 X-element Stainless Steel JH-X ~ Vacuum Automatic Cast Steel or ~ Series Bimetal Stainless JH-8 ~ Series -1,740 JH.w Series ~ 1.5-650 au;<kll'ap. I.5-1,500 800 14,950 Vacuum Automatic Steel Cast Steel Optional or 986 970 Automatic Low Alloy LEX Cast Steel FS,~ Automatic Stainless 800 1,510 Bimetal Steel Heat Exchangers Tank Heaters Coils, Dryers Unit Heaters Equipment Steam Mains Turbines Tracer Lines Heaters Heat Exchangers Steam Mains Small to Equipment Steam Mains Turbines Tracer Lines SS ~ c] Automatic Stainless Steam Mains 1.5-650 800 1,510 Series Bimetal Steel Tracer Lines SH Series ll!j I.5-1,500 800 2,1 JO Automatic Bimetal Cast Steel Superheated or High- Steam Mains Equipment Cast Iron Large Capacity J10 ~w Manual (JIO) Equipment JH15 7-650 800 366,470 - JL Vacuum Automatic Air Vent Cast Steel Heat Exchangers (JHI SJ Heaters Cast Iron (JL 9X/JLI 4-XJ Series -450 464 133,560 Cast Steel X-element (JLH9X/ JLHI 4-XJ Large Capacity Equipment Heat Exchangers Heaters The highest figures listed may not apply to all traps within each series. Full product details (sizes, pressures, capacities and materials) are included in the individual specification data sheets (SDS). Local regulations may restrict the use of these products to below the conditions quoted. Contact TUI directly or your local representative for further information. Special TUI Free Float traps available for: Biotechnology Applications Dowtherm Soot Blowing Gas and Air Applications I ~CAUTION I DO NOT DISASSEMBLE OR REMOVE THIS PRODUCT WHILE IT JS UNDER PRESSURE. Allow internal pressure of this product to equal atmospheric pressure and its surface to cool to room temperature before disassembling or removing. Failure to do so could cause burns or other injury. READ INSTRUCTION MANUAL CAREFULLY TUl CORPORATION 13901 South Lakes Drive, Charlotte, NC 28273-6790 Tel: [1]-704-597-9070 Fax: [1]-704-583-1610 E-mail: tlv@tlvengineering.com For Technical Service 1-800 "TLV TRAP" (0} Internet World Wide Web Manufacturer ISO 9001 /ISO 14001 TLv. @ co.. LID. KakDgawa, Japan ii appnmld IJj UllA Lld. td 9l 11111/14llDI URL http://www.tlv.com Pamphlet A2000 Rev. 2/201 4 Specifications subject to change without notice.