VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Similar documents
Lamp Supply (Recommended)

VQ600 Series Combustible Gas Sensing Head

VQ500 Series Combustible Gas Detector Elements

IR25 Dual Gas Series Datasheet

IR15 Dual Gas Series Datasheet

IR1 Single Gas Series Datasheet

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

MICROpeL 75 Combustible Gas Sensor Part Number: PM

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

SERIES 47K GAS SENSOR

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

THE BELGIAN PIONEER IN GAS DETECTION

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

IRceL CH4 Methane (CH 4

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Certificate of Compliance

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Integrated IR Datasheet

IECEx Certificate of Conform ity

Dräger Polytron SE Ex Fixed Gas Detector

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Certificate of Compliance

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Technical data sheet TDS0060

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Flame 2100 Flame Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Technical data sheet TDS0034

Dräger Polytron Pulsar 2 Open Path Gas Detector

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

ULTIMA X5000. MSAX5000.com

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

The MiCS-4514 is a compact MOS sensor with two fully independent sensing elements on one package.

S5000 Gas Monitor. GMS5000.com

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Flame 2500 Flame Detection

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

The MiCS-5524 is a compact MOS sensor.

Dräger X-am 5000 Multi-Gas Detection

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

ALTAIR 5X Multigas Detector Product Specification

MODEL: O ELECTROCHEMICAL O2 DETECTOR (Used with ST1400 O2 Sensor) Part Number: MAN Rev. 0

For the Safety of Your

Danfoss gas detection unit Type GD Heavy Duty

SEC 5000 IREvolution Gas Detector

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

M7100 Pressure Transducer

Flameproof Manual Call Points Series MCP

Dräger Polytron 5720 IR Toxic Gas Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Zareba Sensepoint Pro

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger PEX 3000 Flammable Gas Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Dräger X-am 7000 Multi-Gas Detection

Model D12-IR. Digital Gas Transmitter...

Guide for hazardous areas

ATM Lighting sp. z o.o

RK-05 Combustible Gas Transmitter Operator s Manual

Dräger X-am 5000 Multi-Gas Detection

THE BELGIAN PIONEER IN GAS DETECTION

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Operation and Maintenance Manual

P R O D U C T D ATA S H E E T

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Transmitters/Sensors. OLCT Series

P R O D U C T D ATA S H E E T

RK Multi Point Detector Operator s Manual

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

IRmax & IREX accessories

Transcription:

SGX Europe Sp. z o.o. VQ600 Datasheet Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) The VQ600 Series is designed to detect and monitor various gases in the range 0 to 100% LEL for combustible gases and 0 to 100% volume in thermal conductivity mode when using the SGX range of pellistor gas sensors. The VQ600 Series is designed for use as an integral part of a fixed gas detection system. The head comprises a stainless steel flameproof enclosure constructed with an integral stainless steel sinter which allows the safe entry of the atmosphere being tested. There are three types of mounting thread available to allow easy fixing to the junction box of the fixed system and the facility to attach accessories to the sensor via an external M46 thread. FEATURES Designed for fixed gas detection systems For detection of the following: o Combustible gases (Catalytic Sensors) o Light gases (e.g. hydrogen and helium). (Thermal Conductivity Sensors) LEL and % Volume Monitoring Diffused gas sampling via sinter Three thread options available Operational in varying temperature, pressure and humidity Fast response Rugged stainless steel construction No moving parts Resistance to corrosion Low maintenance Accessories available for field applications ATEX certified CSA certified (Canada and US) The head must be mounted so that the cable is protected. This is normally achieved by mounting it into a port in a suitable junction box. Although SGX generally recommends that pellistors should be run with a constant voltage supply to the bridge, it is possible to use a constant current supply provided that the voltage across the bridge in clean air remains within the recommended limits. It is essential that the head be efficiently earthed (grounded). This may be achieved by mounting it either into an earthed metal junction box, or into a non-metallic junction box fitted with an earth continuity plate used in accordance with the box manufacturer's instructions. There are no internal connections to the sensing head body. TECHNICAL SPECIFICATION Mechanical Dimensions See Outline on Page 4 Body material Stainless Steel Weight 435g OPERATION The pellistor used in the head should be operated in the manner recommended in the appropriate data sheet. In general it is recommended that the detector and compensator be run in a Wheatstone Bridge circuit so that a difference signal may be obtained. A suitable circuit is shown in Fig. 1. In use, the bridge supply voltage should not be allowed to vary by more than the specified +0.1 V, or the output in clean air may change in sympathy. Environmental Ambient temperature range for operation (ATEX): for operation (CSA): storage: Operational pressure range Humidity range for operation and storage Detected Electrical DC supply to detectors Typical power -20 C to +60 C -20 C to +65 C -20 C to +60 C 700kPa to 1300kPa 0 to 100% RH (Non-condensing) Combustible, Light See Configurations Table on Page 2 Refer to Pellistor Datasheet Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also reserves the right to change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of sale in respect of infringement of third party patents arising from the use of SGX products in accordance with information contained herein. In case of modification of the product, SGX disclaims all liability. SGX Europe sp.z o.o. REGON: 362332227 DS-0240, Issue 1, 16-May-2016, Page 1

CONFIGURATIONS Base Sensor Pellistor (See Note 1) Operating Voltage (V) (See Note 3) Typical Current (ma) Thread Code (See Table Below) 1 2 3 601 VQ1B 2.0 300 Catalytic Yes Yes Yes 603 VQ3B 2.5 330 Catalytic Yes Yes 605M VQ5MB 2.0 175 Thermal Conductivity Yes Gas s Light 606M VQ6MB 2.0 300 Thermal Conductivity Yes Yes Light 621T VQ21TB 2.0 300 Catalytic Yes Yes Yes 621TS VQ21TSB 2.0 300 Catalytic Yes 622T VQ22TB 2.0 175 Catalytic Yes Yes Yes 623 VQ23TB 2.5 335 Catalytic Yes Yes 625 VQ25B 2.0 300 Catalytic Yes Yes Yes Most Flammable (Not including Methane) 631M VQ31MB 3.5 90 Thermal Conductivity Yes Yes Yes Light 635M VQ35MB 4.2 55 Thermal Conductivity Yes Yes Yes Light 641TS VQ41TSB 2.0 100 Catalytic Yes Note 1: Refer to the datasheet for each Pellistor for more information. Note 2: If the desired Thread is listed as please contact SGX. Note 3: Thermal Conductivity sensors can be operated at voltages different to stated above depending upon target gas type. THREAD CODES The sensing head is supplied with one of three different mounting threads at the user's choice (see outline on Page 4). Thread code Thread Dimension X (mm) 1 Metric 20 x 1.5 mm 16.00 2 ANP (Taper) ½" - 14 NPT 19.85 3 ANP (Taper) ¾" - 14 NPT 20.16 Taper threads are manufactured in accordance with ANSI/ASME B1.20.1. Yes Most Flammable (Not including Methane) OPERATING CIRCUIT R 1 = R 3 = 500 to 5000, R 2 R 1 /5 R 2 provides zero adjustment and may be omitted if not required. SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 2

CERTIFICATION ATEX CSA Certificate / File: BAS 01ATEX2110X 2589678 Standards: Product Marking: EN 60079-0:2012 IEC 60079-1:2014 Ed.7 II 2G Ex db IIC T5 Gb CSA C22.2 No.30 (M1986) CSA C22.2 No.142 (M1987) FM 3600 (Nov 1998) FM 3615 (Feb 2006) Class I Groups B,C&D Certified Manufacturing Locations: Certificate Address: SGX Europe Sp. z o.o., SGX Europe Sp. z o.o., INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS (Ref : EU ATEX Directive 2014/34/EU) 1. The head is classified as flameproof equipment and is marked: BAS01ATEX2110X II 2G Ex db IIC T5 Gb T amb = -20 C to +60 C 2W/5V MAX The head should only be used within the limits imposed by this certification and by these conditions of use. 2. The head may be used in a hazardous area without further mechanical protection. However, the cable requires mechanical protection and must be terminated in a suitable enclosure. 3. The head must be efficiently earthed (grounded). This may be achieved by mounting it into an appropriate earthed metal junction box or into a non-metallic junction box fitted with an earth continuity plate used in accordance with the box manufacturer's instructions. There are no internal connections to the sensing head body. 4. In the event that the head becomes embedded in a junction box by over-tightening or corrosion, it may be released by the use of a spanner or wrench on the two flat surfaces on the sides of the body. 5. There are no user serviceable parts inside the body of the sensing head, and no attempt should be made to open the body for any purpose. The unit is non-repairable. 6. The head has not been assessed as a safety device (EHSR 1.5). 7. When installed in outdoor locations where rain or spray could interfere with the safe working of the head, or in indoor locations where water jets, sprays, or hoses are used routinely for cleaning purposes, the head should be fitted with the Weather Cap that is available as an accessory. 8. The end-user/installer should be aware that the certification of the head relies in its construction on the use of the following materials, which are suitable for most common applications: Enclosure... Stainless Steel Sinter... Stainless Steel Bushing... Epoxy resin In accordance with the Note in EN60079-0:2006 Clause 6.1, the end-user/installer shall inform the manufacturer of any adverse conditions that the head may encounter. This is to ensure that the head is not subject to conditions that may cause degradation of these materials. SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 3

OUTLINE (All dimensions in millimetres; dimensions without limits are nominal) Terminal Connections Lead Colour Element Blue Detector Red Compensator Yellow Common ACCESSORIES (All dimensions in millimetres) Three accessories are available to complement the VQ600 Series gas detection head. Flow Cap DAS546633AA Weather Cap DAS546632AA The Flow Cap allows the VQ600 to be used in applications where it is to be aspirated permanently with a pumped or pressurised sample. The cap is made of 316 stainless steel and can be used in a variety of applications involving pumped sampling analysis or detection systems. The Weather Cap protects the VQ600 from water when used in external locations, where rain or spray could interfere with the safe working of the head, or in internal locations where water jets, sprays or hoses are used routinely for cleaning purposes, etc. The cap is made of 316 stainless steel and has been tested to IP64 for effectiveness, and also to ensure that it does not significantly affect the VQ600's performance. SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 4

Quick Calibration Hood DPP546618DA ORDERING INFORMATION (VQ600) VQbase/n BASE SENSOR TYPE Refer to Configurations Table on Page 2 THREAD CODE Refer to Thread Codes Table on Page 2 Examples VQ621T/1 VQ600 series head fitted with VQ21TB pellistor and supplied with 20 x 1.5 mm metric thread cap. VQ603/2 VQ600 series head fitted with VQ3B pellistor and supplied with ½" - 14 NPT American National Pipe Taper thread. The Quick Calibration Hood is constructed from polypropylene, and provides a convenient means of supplying test gases to the VQ600 in the field, for calibration and checking purposes. The assembly push-fits into the central gas access recess of the head, and is designed to accommodate 6 mm ID or ¼" flexible tubing. SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0240, Issue 1, 16-May-2016, Page 5