BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Similar documents
RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

BESB Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

RS Chimney Fan for Solid Fuel Applications

RSIB Power Venter

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

RS Chimney Fan for Gas & Oil Applications

RSV Chimney Fan USA CAN. Start Up and Configuration. ... Chapter 5. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

RS chimney fan for gas and oil applications

RS Chimney Fan for Gas & Oil Applications

ENERVEX RSV CHIMNEY FAN

IPVB EC inline power venter

ENERVEX IPVB INLINE POWER VENTER

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

ENERVEX GSV GREASE FAN

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

GSV 9-16 Grease Fan for Solid Fuel Applications. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

MFD Mechanical Fireplace Damper

GSV Grease Fan

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

ENERVEX GSV GREASE FAN

ENERVEX MFD MECHANICAL FIREPLACE DAMPER

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

EW 40 Wireless Fan Control

ENERVEX ADC100 DRAFT CONTROL

ADC150 Automatic Draft Control

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

ENERVEX VHX VORTEX HEAT RECOVERY CENTER

EBC 12 Modulating Fan Control

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Installation Instructions Part No , Part No Part No

Installation, Operation, and Maintenance Manual

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

MEC 18 Mechanical Exhaust Control

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Mighty Venter Power Vent System

WAILEA OWNER S MANUAL

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Use, Care, and Installation Guide

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

MIST MAX MODEL MM800. Important: Installation and Operation Manual

e Bath Fan with Light User s Guide

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Cooktop Chimney Ventilation Hoods

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

e Heater/Exhaust Fan/Light User s Guide

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

UNDER CABINET RANGE HOOD

e Bath Fan with Light User s Guide

Integrated Ventilation System

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Installation Instructions Remote Blowers

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

MODEL CDB8 INSTALLATION INSTRUCTIONS

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

INSTALLATION INSTRUCTIONS

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

READ AND SAVE THESE INSTRUCTIONS

USER S INFORMATION MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

M Series Fan Filter Units

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Duct and Rough Service Carbon Monoxide Sensor

Installation Instructions Exhaust Fan With Light

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

SAFETY AND INSTALLATION MANUAL MODEL 8100

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

Transcription:

Installation & Operating Manual BESF Box Ventilator USA CAN Product Information... Chapter 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration... Chapter 5 Maintenance and Troubleshooting... Chapter 6 Job Name: Installer: Installation Date: EXHAUSTO Inc. 1200 Northmeadow Pkwy. Suite 180 Roswell, GA 30076 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@exhausto.com us.exhausto.com

1. Product Information 2. Specifications 3. Mechanical Installation 4. Electrical Installaion 5. Startup & Configuration 1.1 Function... 3 1.2 Components... 3 1.3 Shipping... 4 2.1 Dimensions & Capacities... 5 3.1 Positioning... 6 3.2 Floor or Roof Mounting... 6 3.3 Ceiling Mounting... 7 3.4 Connection to Duct... 7 4.1 General... 8 4.2 Wiring Diagram... 8 5.1 System Testing... 9 5.2 Adjusting the Fan Speed... 9 5.3 Adjusting the Proven Draft Switch... 9 6. Maintenance & Troubleshooting 6.1 Cleaning Intervals... 10 6.2 Cleaning... 10 6.3 Troubleshooting...11 Symbol Legend: The following terms are used throughout this manual to bring attention to the presence of potential hazards or to important information concerning the product. Danger: Indicates an imminent hazardous situation which, if not avoided, will result in death, serious injury or substantial property damage. Caution: Indicates an imminent hazardous situation which, if not avoided, may result in personal injury or property damage. TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed on the front of the manual. 2. Before servicing or cleaning the unit, switch off at service panel and lock service panel to prevent power from being switched on accidentally. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with applicable codes and standards. 4. Follow the appliance manufacturer s guidelines and safety standards such as those published by the National Fire Protection Associations (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. 5. This unit must be grounded. How to use this manual This installation manual does not contain any system design documentation. System design documentation is available from any authorized EXHAUSTO representative. Accessories, fans and variable frequency drives are not covered by this manual. Please refer to these component s individual manuals. 2

1.1 Function Use Construction 1. Product Information EXHAUSTO Model BESF is a box ventilator that can be used for the movement of air in exhaust and air supply systems where no explosive gases are present. The ventilator cannot be used for transport of large particles. It is designed to provide a high capacity at a high static pressure. The ventilator can be installed indoors as well as outdoors. No special treatment or preparation is required for weather proofing. Suitable uses include, but are not limited to: comfort ventilation, residential kitchen ventilation, exhaust and air supply. The exhaust temperature must be above 10 F(-12 C) but should not exceed 175 F(80 C). The ambient temperature must be within -20 F(-30 C) and 105 F(40 C). The ventilator housing is made of galvanized steel and insulated with fiber insulation. The collars are fitted with silicone seals to assure a tight assembly. The motor is a direct drive, variable speed class B insulated type. It has permanently lubricated, sealed ball bearings and is maintenance free. Listings EXHAUSTO Model BESF is tested and listed to UL 705, Standard for Power Ventilators. The BESF can be used as a component in a MCAS, Modulating Combustion Air System. The listings of this system incorporates the BESF Box Ventilator. Do not use with explosive gases. Do not use for transport of large particles. 1.2 Components The box ventilator consists of the following components: a. Housing f. Locking hinge b. Access door g. Door handle c. Motor h. Support legs with vibration dampers (2) d. Centrifugal impeller i. Sheet metal screws (4) e. Ventilator housing k. Door switch (optional) Fig. 1 3

1.3 Shipping Protection The ventilator is protected by a corrugated box. Do not place other products or items on top of the box. After unpacking, the product must be handled in a way to prevent damaging the collars and the ventilator housing. Fig. 2 Never operate the power venter with the access door open! To open access door loosen screws on latch handles and raise handles. Never operate the ventilator with the access door open! To open access door loosen screws on latch handles and raise handles. Standard Packing The ventilator is shipped with motor installed on the access door. If other components are shipped, these will appear on the shipment packing list. 4

2. Specifications 2.1 Dimensions & Capacities Model BESF 146 BESF 160 BESF 180 Fan Type Centrifugal Impeller (F-Wheel) Motor Type TEFC Voltage V AC 1x120 Amperage Amps 1.2 2.9 5.8 Motor Output HP 0.1 0.2 0.5 kw 0.08 0.16 0.35 RPM 1600 Weight lbs 28 38 60 kg 13 17 27 Duct Connection E in 7 8 8 mm 177 200 200 Dimensions A in 13.60 14.57 16.15 mm 345 370 410 B in 11.62 12.60 13.98 mm 295 320 355 C in 7.88 9.26 9.26 mm 200 235 235 D in 4.33 5.52 7.68 mm 110 140 195 G in 13.78 15.75 15.75 mm 350 400 400 H in 6.50 7.10 7.88 mm 165 180 200 J in 7.88 8.27 9.26 mm 200 210 235 K in 4.33 5.12 5.12 mm 110 130 130 R in 13.60 14.57 16.15 mm 345 370 410 Capacity Chart P t (inw.c.) 2.0 1.8 1.6 1.4 1.2 BESF 180 1.0 BESF 160 0.8 BESF 146 0.6 0.4 0.2 0.0 0 250 500 750 1000 1250 Volume (cfm) 1500 5

3. Mechanical Installation 3.1 Positioning The ventilator can be installed in many different positions. However, it should always be possible to open the access door at least 80 degrees, and the locking bolts should always be accessible. Acceptable ventilator positions are shown below in Fig. 3. Note that the ventilator motor can never point straight down as this could cause condensation build-up around the shaft, which can shorten the product life.! Never install the power ventilator so the motor points down. This will shorten the life. Fig. 3 3.2 Floor or Roof Mounting To minimize the transfer of noise and vibration the ventilator should be placed on a surface that is level, stable and vibration-free. The ventilator does not need to be secured by any means. See Fig. 4 on page 7.Once the installation location has been selected the support legs must be installed. For the standard position bolt holes are pre-drilled so the legs should just be aligned and secured with the enclosed sheet metal screws. For all other positions, the legs should be placed in a proper position and holes should be drilled prior to securing the legs to the ventilator by means of the enclosed sheet metal screws. When placing the ventilator, make sure the access door can open approximately 80. See Fig. 5. Fig. 4 Fig. 5 6

3.3 Ceiling Mounting The box ventilator can be mounted with plumber s strap or threaded rod with nuts and washers, or it can be placed on support legs (included). As Fig. 6 illustrates, the ventilator can be placed in virtually any position or direction, except with the motor pointing down. When placing the venter on the support legs (1), the vibration dampers (4) should be used and secured by nuts (2). The support legs are attached to the bottom of the venter using the enclosed sheet metal screws (3). In this configuration the venter is typically placed on a shelf hung from a wall. If hanging the venter from the ceiling, threaded rods should be used. Attach the support legs (1) to the bottom of the fan and secure with the sheet metal screws (3). Do not use the vibration dampers. Instead use the holes on the top of the legs for the threaded rods and secure these with the nuts (5). Fig. 6 3.4 Connection to Duct In order to achieve optimal perfomance and energy consumption, the duct must be installed as shown in Fig. 7 and the distances observed. If transfer of vibrations is a major concern special vibration dampening connectors (FLF) should be installed. These are available from EXHAUSTO. If a duct is not connected, a safety screen (accessory), as shown in Fig. 8, must be installed. Make sure the sizing of the ventilator takes the resulting static pressure loss into account. Fig. 7 Fig. 8 D FLF 3 x D 3 x D D FLF 7

4.1 General 4. Electrical Installation Danger: Turn off electrical power before servicing. Contact with live electric components can cause shock or death. All electrical wiring must be in accordance with requirements of authority having jurisdiction or, in absence of such requirements, with National Electrical Code NFPA 70 latest edition. If an external electrical source is utilized, system must be electrically grounded in accordance with requirements of the authority having jurisdiction or, in the absence of such requirements, with the National Electrical Code NFPA 70 latest edition. The ventilators have a split capacitor motor with infinitely variable speed. The fan speed control supplied is rated 1x120V/60 Hz and 5 Amps. It has an adjustable low voltage set point of min. 65 V +/- 5 V. Notice: If any of the original wire supplied with the system must be replaced, use similar wire of the same temperature rating. Otherwise, insulation may melt or degrade, exposing bare wire. 4.2 Wiring Diagram - BESF 146-180 Ventilator and motor specifications can be found on page 5. The ventilator can be equipped with a variable speed motor. Fig. 9 shows a typical wiring diagram for a BESF utilizing a Fan Speed Control. Fig. 9 24 VAC PROVEN DRAFT SWITCH ORANGE FAN MOTOR RED WHITE BLACK GREEN COM TR HOT TH 24V GAS VALVE 120/1/60 N WEATHERPROOF BOX L All wiring must be in flexible or rigid metal conduit FAN SPEED CONTROL NOTES: 1 THE DISCONNECT MEANS AND CIRCUIT PROTECTION ARE TO BE PROVIDED BY THE INSTALLER OF THIS DEVICE LEGEND: 24 VAC 120 VAC 8

6. Start-up and Configuration 5.1 System Testing Before any adjustments are made to the system, follow these procedures: 1. Turn the fan ON and make sure that it is operating. Increase and decrease the speed of the fan by adjusting the fan speed control to make sure it is operating properly. 2. Turn the fan OFF and make sure the pressure switch opens, so the power to the circuit, it controls, is disconnected. Danger: Check other heating appliances (water heater, furnace, fireplace etc.) for proper operation while the ventilator is operating. Make sure no flue gases are spilling out as this can lead to carbon monoxide poisoning. 5.2 Adjusting the Fan Speed Start up all appliances. Use the fan speed control to set the speed of the ventilator so no back pressure is experienced anywhere in the system. Check the system for flue gas spillage. Mark this setting on the fan speed control cover. 5.3 Adjusting the Proven Draft Switch Setting Remove the snap-on cover from the conduit enclosure by loosening its retaining screw. Turn the slotted Adjustment Screw clockwise to raise the set point pressure and counter clockwise to lower the set point. Set the adjustment to its lowest position. With all appliances operating, reduce the speed of the fan to the set point, where the appliance(s) starts to spill flue gas. Increase the speed of the fan gradually to the point where there is no more spillage. Raise the switch s set point so it opens. Return the fan speed to the original setting marked on the cover. The system is now adjusted so the flue gas spillage will disconnect the heating appliance(s). The procedure described here may not cover all Proven Draft Switches, so please review the Installation Manual for the switch being used. 9

6. Maintenance & Troubleshooting 6.1 Cleaning Intervals The ventilator is designed for prolonged use. It must be inspected and cleaned at least every 12 months. The need for cleaning is dependent on the type of application and how the ventilator is operated. 6.2 Cleaning Deposits should be removed from the impellers and the bottom of the ventilator: 1. Turn the fan off at the repair switch. 2. When the blower wheel no longer rotates, open the access door. 3. Clean the inside housing and the wheel with water containing a detergent. 4. Dry all parts with a cloth. 5. Close and secure the access door. 6. Turn the fan on. Fig. 18 If necessary, the blower wheel can be removed. Prior to removal, mark the position on the shaft. The placement of the wheel is also shown on a label placed on the inside of the access door. Do not remove the balancing weights on the impellers. Vibration in the ventilator can be caused by a dirty impeller. No other maintenance is required. 10

6.3 Troubleshooting Problem Probable Cause What to do Fan is making too much noise. Fan is vibrating and making noise. Ducting is too small for the volume of the air. Ducts/Filters are dirty/clogged. Fan inlet or outlet is too close to the customer. Damaged during shipping or installation. Dirt build-up on blower wheel. Fan and air ducts not installed with vibration dampers. Resize ducts. Clean and inspect ducts and filters. Relocate duct or fan. See if blower wheel is damaged or if motor shaft is bent. Replace if damaged. Clean wheel. Install vibration dampers. Fan is not working Power is off. Switch on power to the fan. Fan is getting power, but will not run. Fan is overheating and cycling on and off. Capacitor is not wired correctly. Fan speed control is bad. Blower wheel is stuck due to dirt buildup. Fan speed control is set too low. Motor bearings have seized. (Refer to section 1.1 Use.) Motor capacitor has failed. (Refer to section 1.1 Use.) Dirt build-up on blower wheel. Motor capacitor has failed. (Refer to section 1.1 Use.) Motor windings or bearings are failing. (Refer to section 1.1 Use.) Rewire connection. Bypass fan speed control. If fan now operates at 100%, replace fan speed control. Clean blower wheel. Set fan speed control to highest setting until fan is up to speed. Then reduce speed. See that the fan is operating within its design parameters. Replace the motor. Please refer to Fig. 12 and insure that capacitor is connected correctly. Check amp draw with and without the capacitor being connected. If amp draw is the same, replace capacitor. Clean blower wheel. Please refer to note in section above. Check amp draw. If incorrect, replace blower motor. 11

3002443 05.05 BESF 146, BESF 160, BESF 180 EXHAUSTO Inc. 1200 Northmeadow Pkwy. Suite 180 Roswell, GA 30076 P: 770.587.3238 F: 770.587.4731 T: 800.255.2923 info@exhausto.com us.exhausto.com