STANCOR Oil-Minder Simplex & Duplex Pump and Control Systems

Similar documents
Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

TYPE POS Oil Shield Sump Pump

Elevator Sump Kits and Components

Elevator Sump Kits and Components

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

Barnes Oil Sensor Switch

PO Box 827 Hawley, MN (218) Fax (218)

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

RQE Series Temperature Controllers

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

S1L Series: Metal Bottom

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Unilift KP, AP, SU/SV, SE & EF

Plumbing Supply Products

Electric Submersible Pumps

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Reliable Long-Term Solutions For Your Toughest Pump

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Professional Plumbing brands you trust.

POULTRY MARKET CATALOG

DUPLEX CONDENSATE TANK SYSTEM

SECTION SANITARY SEWAGE PUMP STATIONS

SENTRA Series Water Unit

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Circulating Water Temperature Controller

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT

INSTANT-FLOW C-MICRO WATER HEATER

SECTION STEAM CONDENSATE PUMPS

FX5 Series Explosion-Proof Electric Air Heaters

Plumbing Supply Products

Electric Submersible Pumps

TIMER CONTROLLED DRAINS

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

INSTANT-FLOW C-MICRO WATER HEATER

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

We ve Got Panels Under Control.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

K4RH(X) Solids-Handling Pumps

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

MDVS Tag: DF-1, DF-2. Architect/Engineer: Contractor: EXHAUSTO Job File: Use. Sizes. Listings. Description. CSI Specifications.

SIMPLEX WEATHERPROOF CONTROL PANELS

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Centro-Matic Automated Lubrication Systems System Controls

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

product brochure Sump, Effluent and Sewage Controls

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Dräger PIR 7200 Toxic Gas Detection Transmitter

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

Mound System Pressure Distribution Worksheet

CONDENSATE MANAGEMENT SYSTEMS

Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Liebert CSU3000 Chiller

SECTION ROTARY-SCREW WATER CHILLERS

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

LC Series - Light Commercial Pump Station Installation and Operation Manual

Central Chillers TS Series

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

SECTION 1-1 SAFETY PRECAUTIONS DOUGH CONVEYOR CHAPTER 1: SAFETY

AlarmLine Addressable Linear Heat Detector

SUPER FLO TM GI-2000 OPERATION, INSTALLATION AND MAINTENANCE MANUAL VERSION /2007 FULLY AUTOMATED GREASE RECOVERY DEVICE (G.R.D.

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

SERIES WM-20(T) & WM-40(T)

AccuBrine automated brine maker Technical Specifications

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Explosion Protected Panelboards D2Z Series

Instructions for Baptistry Immersion System

MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

FEATURES. Other Fed-Flush Arrangements

Series 5000 Hydrazine Analyzer Model 60002

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

SECTION WASTEWATER PUMPING STATION DESCRIPTION

LQ AQ SQ. Air-cooled and water-cooled portable chillers

brands you trust. The Next Generation of SH Series Pumps BARNES SH SERIES PUMPS

Unimaster Dust Collectors

SECTION STEAM CONDENSATE PUMPS

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE

LQ AQ SQ. Air-cooled and water-cooled portable chillers

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

Transcription:

STANCOR Oil-Minder Simple & Duple Pump and Control Systems Solid State, NEMA 4 Oil-Minder Control Features SE50 Pump with Float & Oil-Minder Probe The Stancor Oil-Minder Control and Pump System allows water to be automatically pumped from elevator pits, transformer vaults, and industrial sumps without danger of ejecting potentially harmful oily substances into sewers, rivers and waterways. There is no need for a separate oil-water separator. The product is engineered for efficient and trouble free pumping, even under the most severe conditions. The Stancor Oil-Minder System is the overwhelming choice among design engineers and compliance authorities worldwide, and has a proven record for protecting valuable equipment and the environment. NEMA 4 weathertight corrosion resistant polycarbonate enclosures Stainless steel sensor probe with patented electronic technology that repels dirt contamination Single direct plug-in power source for operation of entire system Solid state components Alarms, lights, silence switch, and remote monitoring circuit for oil, high liquid, and high amperage conditions Solid state push to test switch conveniently performs all pump and control diagnostic tests Complete factory assembly and testing insures quality of entire pump and control system Patented - Pat. #4,715,785, #4,752,188, #6,203,281 and others pending Oil-Minder System can be combined with a variety of different pumps and valves Choice of: 115v or 220v (1 phase) OR 230v/460v/575v (3 phase) LED indicator lights for oil spill, power, high liquid level, overload, and pump run UL 508 and 778 approved ENTELA tested and approved as a system There Is Only One Oil-Minder System and Stancor Makes It Quality You Can Believe In

Description of Stancor Simple Oil-Minder Systems The Stancor Simple Oil-Minder System is available in two primary configurations, as follows: The Multi-Option Oil-Minder System is designed for easy, fool-proof installation. All pump and control cables are factory wired into a wall mountable junction bo. Between the junction bo and the main Oil-Minder control panel is a multi-pin quick connect cable. This single cord, 8-pin system allows the electrical cable between the junction bo and control panel to be run through conduit and interconnected up to 250 feet long, using a single push and turn motion. There is no need for field wiring. Electrical installation costs are reduced by approimately 75% and all connections are secure and water-tight. The Junior Oil-Minder System is a good choice where the main control is located in the same area as the pump pit, or where the main control will be located remotely and conventional hard wiring is used between a junction bo and the main control. Comparative features of each model are as follows: Feature included in standard package O/M O/M 2 Solid state NEMA 4 control panel Separate LED indicator lights on NEMA 4 control for A) oil alert, B) high water, C) high motor amps, D) power to system, and E) pump activation Self cleaning, hermetically sealed stainless steel oil detection probe (patented technology) Float switches for pump activation and high water alert Separate oil and water monitoring relays for alert conditions at remote locations High decibel, water tight horn and silence switch for alert conditions Direct plug-in activation of entire pump and control system from the main control panel (6 cord and molded plug included) Factory hard wiring of pump, oil probe, and floats into NEMA 4 junction bo Factory hard wiring of pump, oil probe, and floats directly into main NEMA 4 control panel Junction bo with female 8-pin cable receptacle and disconnect 25 8-pin Quick Connect cable (epandable to 250 with interconnecting etension cables) Female 8-pin cable receptacle installed in the NEMA 4 control panel Push to Test switch on panel for all pump and control diagnostic functions

Stancor Simple Oil-Minder Controls Oil-Minder Junior Standard Pump Selection Chart 16 ft. cables Head - Ft. General & Electrical Specifications (Special voltages and pump models available upon request) Model H.P. Voltage RPM Rated Discharge Ma Ma Full-Load Size Head Flow Amps Ft. GPM SE50 0.5 115/230 3600 8/4 2 37 74 460 SE40 0.4 115 3600 5 2 22 64 Flow - U.S. Gal./Min. 3

Additional Pump Selections ASME A 17.1 Section 2.2.2.5 (2007) requires that, for each building elevator, the elevator sump pump shall be capable of pumping at least 3,000 gallons per hour. Therefore, after considering vertical lift and pipe friction losses, a larger pump selection may be necessary for certain projects. No matter what the pump capacity requirement may be, Stancor has an Oil-Minder System that will do the job. Please refer to the chart below for additional commonly specified pump selections. Stancor manufactures pumps up to 75 HP, details of which can be found at www.stancorpumps.com. Specifications Output Discharge Rated Cable Pump & HP Voltage Amps In. Ma. Ma. Length System Model Head (ft) Capacity (ft) SE-40 O/M 4/10 115 5 2 22 64 GPM 16 SE-50 O/M 1/2 115/220/460 8/4/2 2 37 74 GPM 16 SE-100 O/M 1 115/220/460 14/7/3.5 2 50 100 GPM 33 SE-100HH O/M 1 115/220/460 16/8/4.5 2 80 80 GPM 33 SE-200 O/M 2 220/230/460 21/10/5.5 2 (3 ) 62 172 GPM 33 SV-300 O/M 3 230/460 9/5.2 3 (4 ) 70 210 GPM 33 SV-500 O/M 5 230/460 15/8.6 3 (4 ) 80 280 GPM 33 SV-750 O/M 7.5 230/460 22.5/12.8 3 (4 ) 90 330 GPM 33 1. Guiderail systems are available for all Stancor pumps 2. Elbow with female threaded connection provided, standard 3. 208V available as special order 4. Models up to 7 amps are available with 8-pin quick connect cable and standard on all O/M Multi-Option Systems TOTAL HEAD - FT Series SE Performance Curves 70 60 50 40 30 20 10 0 SE-50 SE-40 SE-100 SE-200 20 40 60 80 100 120 140 160 FLOW - U.S. GPM TOTAL HEAD - FT Series SV Performance Curves 100 90 80 70 60 50 40 30 20 10 0 SV-500 SV-300 SV-750 20 100 150 200 250 300 FLOW - U.S. GPM Stancor, Inc. 515 Fan Hill Road Monroe, CT 06468 Phone 203-268-7513 Fa 203-268-7958 www.stancorpumps.com