APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

Similar documents
SECTION EXTERIOR LIGHTING

Comtran Cable. Hub-LINK Cables for Transit Applications

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

ASSOCIATIONS AND REFERENCE STANDARDS

5. Identification products.

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Capital Projects Group

SECTION ELECTRICAL GENERAL PROVISIONS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Electrical Safety Program.

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

Flexible Power Cable DLO

4.13 Security and System Safety

I. INTRODUCTION Codes, Rules, Laws, & Requirements

PARKLET PROPOSAL PACKAGE & PROCESS

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Listing of Government Agencies, Codes and Industry Associations

PART 1 GENERAL 1.01 SUMMARY

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SECTION ELECTRICAL SYSTEMS COMMISSIONING

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

BSR/ASHRAE Addendum b to ANSI/ASHRAE Standard FORWORD

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

Are You Prepared? The impending impact of Code on Servicing Security Systems

Electrical Grounding For Oil and Gas Applications

PART 1 GENERAL 1.01 SUMMARY

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

. SECTION CONTROL-VOLTAGE ELECTRICAL POWER CABLES

Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

ANSI NFSI B101.0 Walkway Auditing Standard. Brent Johnson Traction Auditing LLC

GRADE CROSSING SIGNAL SYSTEM SAFETY REGULATIONS

4.11 SECURITY AND SYSTEM SAFETY

NFPA Changes

FAQs - Codes and Listings

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

Interpreting the National Electrical Code. By Tim Kuhlman, PE, RCDD

CHAPTER 6 [CE] REFERENCED STANDARDS

Special Provision No. 683S28 December 2017

ITU-T L.63. Safety practice for outdoor installations

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Public Comment No. 1-NFPA [ Section No ]

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Aashto Maintenance Manual For Roadways And Bridges Full Online

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Element Z General Design Requirements Owner Standards and Other Requirements

Fire Prevention Plan

SECTION GENERATOR PARALLELING CONTROLS

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

Nfpa 13 Automatic Sprinkler Systems Handbook 2010 Edition Pdf

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

HIGH-RISE RETROFIT ORDINANCES - NO and NO

DEPARTMENT OF DEFENSE HANDBOOK COVERED STORAGE 1. THE FOLLOWING PAGES OF MIL-HDBK-1032/2 HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

Fire Prevention Plan

City of San Ramon. Zoning Ordinance. Adopted: October 27, Latest Revisions Effective: March 28, 2018

CHAPTER 20 SERVICE EQUIPMENT

SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Battery Design Considerations

SECTION (15530) - REFRIGERANT PIPING

Pilz Safety Lockout System (PSLS)

42 USC NB: This unofficial compilation of the U.S. Code is current as of Jan. 4, 2012 (see

Electrical Safety Requirements

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Harmonizing Electrical Installation Requirements

BUILDING 751-CEH-OFFICE RENOVATION- OVERALL ROOM DATA SHEET

SECTION COMMUNICATIONS HORIZONTAL CABLING

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

SECTION COMMERCIAL-KITCHEN HOODS

NEC 2017 Changes and Their Effect Upon the ICT Industry

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

This regulation outlines procedures to be followed for fire drills and all school event decorations.

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Figure Breathing respirator Figure Rubber gloves and apron Figure Communications perceptions...

Single Room Occupancy Hotel Safety & Stabilization Task Force

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Surviving the Survivable Cable Crunch

FIRE SERVICE FEATURES

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Standard for tests for flammability of plastic materials for parts in devices and appliances

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

Introduction Consultant shall incorporate the material in the DSS into the project specifications.

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

(a) Flame shall not spread to the outer extremities of the sample on the 8 ft 12 ft (2440 mm 3660 mm) wall. Flashover shall not occur.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

TRANSLUCENT FIRE RATED SYSTEMS

Transcription:

REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS All improvements of the facilities within the jurisdiction of the PCJPB shall be in strict conformance with government codes, regulations, laws, and standards where applicable, including but not limited to the codes, regulations, laws, and ordinances stated in sections and subsections below. 1.1 Federal 1.2 State 1.1.1 Codes of Federal Regulations (CFR) Title 49, Transportation: a. Part 37 Appendix A Standard for Accessible Transportation Facilities, ADA Accessibility Guidelines for Buildings and Facilities b. Part 192 Transportation of Natural and Other Gas by Pipeline c. Part 195 Transportation of Hazardous Liquids by Pipeline d. Part 213 Track Safety Standards for Class 5 Track e. Part 214 Railroad Workplace Safety f. Part 234 Grade Crossing Signal System Safety g. Part 235 Instructions Governing Applications for Approval of a Discontinuance or Material Modification of a Signal System or Relief From the Requirements of Part 236 h. Part 236 Rules, Standards, and Instructions Governing the Installation, Inspection, Maintenance, and Repair of Signal and Train Control Systems, Devices, and Appliances 1.1.2 Manual of Uniform Traffic Control Devices (MUTCD) a. California Department of Transportation (Caltrans) 1. Caltrans Highway Design Manual 2. Caltrans Standard Specifications 3. Caltrans Standard Plans 4. Bridge Design Specifications 1.2.1 California Public Utility Commission - CPUC General Orders: a. CPUC GO No. 26 Clearances b. CPUC GO No. 33 Interlocking Plants SEPTEMBER 30, 2011 C-1

c. CPUC GO No. 36 Abolition of Services d. CPUC GO No. 72 At-Grade Crossings e. CPUC GO No. 75 Protection of Crossings f. CPUC GO No. 88 Rules for Altering Public Grade Crossings g. CPUC GO No. 95 Rules Governing Overhead Electric Line Construction h. CPUC GO No. 112 Utility Construction i. CPUC GO No. 118 Walkways Maintenance and Construction j. CPUC GO No. 128 Rules for Underground Electric Construction 1.2.2 State of California Codes and Code of Regulations (CCR) a. Title 5, Division 1, Part 1, Chapter 5.5, The Elder California Pipeline Safety Act of 1981. b. Title 8, Industrial Relations 1. California Occupational Safety and Health Administration (Cal/OSHA) c. Title 24, Parts 1 to 10 and Part 12, California Building Standards Code (CBSC) d. California Disabled Accessibility Guidebook (CalDAG) 1.2.3 State Historic Preservation Office (SHPO) 2. 0 APPLICABLE ORDINANCES AND DESIGN CRITERIA 2.1 Cities and Counties a. City and County of San Francisco b. San Mateo County c. Cities in the San Mateo County d. Santa Clara County e. Cities in the Santa Clara County 3.0 APPLICABLE GUIDELINES AND INDUSTRY STANDARDS The design guidelines and criteria in this Criteria are based on the best industry practice. The following industry publications, standards, and design guidelines were used as references to develop this design criteria manual. a. American Association of State Highway and Transportation Officials (AASHTO) b. American Concrete Institute (ACI) c. American Institute of Steel Construction (AISC) d. American Iron and Steel Institute (AISI) e. American National Standards Institute (ANSI) SEPTEMBER 30, 2011 C-2

1. 455 Standard Test Procedure for Fiber Optic Fibers, Cables, Transducers and Other Fiber Optic Components 2. 568-B Commercial Building Telecommunications Cabling Standard 3. 569-B Commercial Building Standard for Telecommunications Pathways and Spaces October, 2004 4. 606-A Administration Standard for the Telecommunications Infrastructure of Commercial Buildings May, 2002 5. J-STD-607-A Commercial Building Grounding and Bonding Requirements for Telecommunications October, 2002 6. Z55.1 Gray Finishes for Industrial Apparatus and Equipment f. American Railway Engineering and Maintenance-of-Way Association (AREMA) 1. AREMA Communications and Signals Manual and Recommended Practices Part 1.5.10 Recommended Instructions for Painting and ` Protective Coatings 2. AREMA Manual for Railway Engineering 3. AREMA Portfolio of Trackwork Plans g. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE) h. American Society for Testing and Materials International (ASTM) 1. A48 Standard Specification for Gray Iron Castings 2. A153/A153M Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware 3. B3 Specification for Soft or Annealed Copper Wire i. American Welding Society (AWS) j. Americans with Disabilities Act Accessibility Guidelines (ADAAG) for Buildings and Facilities k. Building Industries Consulting Services International (BICSI) Telecommunications Distribution Methods Manual (TDMM) Edition 10, 2003 l. Crime Prevention Through Environmental Design (CPTED) m. Electronic Industry Alliance (EIA) 1. 310-D Cabinets, Racks, Panels, and Associated Equipment n. Illuminating Engineering Society of North America (IESNA) o. International Building Code (IBC) p. Institute of Electrical and Electronics Engineers, Inc. (IEEE) q. Insulated Cable Engineers Association, Inc. (ICEA) 1. S-84-608-2002 Filled Telecommunications Cable, Polyolefin, Insulated, Copper Conductor SEPTEMBER 30, 2011 C-3

r. Motorola R56 grounding standard s. National Electric Code (NEC) t. National Electrical Safety Code (NESC) u. National Electrical Manufacturers Association (NEMA) CALTRAIN DESIGN CRITERIA 1. WC5 Thermoplastic-Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy 2. WC7 Cross Linked Thermosetting Polyethylene Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy v. National Fire Protection Association (NFPA) 1. 70E Standard for Electrical Safety Requirements for Employee Work places 2. 71 Central Station Signaling Systems 3. 72 National Fire Alarm Code 4. 75 Protection of Electronic Computer Data Processing Equipment 5. 101 Life Safety Code 6. 130 Standard for Fixed Guideway and Passenger Rail System 7. 262 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces 8. 297 Guide on Principles and Practices for Communications Systems 9. 780 Standard for the Installation of Lightning Protection Systems w. Rural Utilities Services (RUS) 1. Specification for Filled Telephone Cable with Expanded Insulation (7 CFR 1755.890) 2. Specification for Acceptance Teats and Measurements of Telecommunications Plant (7 CFR 1755, Bulletin 1753F-201) x. Safety Code For Mechanical Refrigeration (SCFMR) y. Southern California Public Works Handbook (Green Book) z. Telecommunications Industry Associates/ Electronic Industry Alliance (TIA/EIA) aa. 1. TSB67 Transmission Performance Specifications for Field Testing of Unshielded Twisted Pair Cabling Systems 2. TSB72 Centralized Optical Cabling Guidelines 3. TSB75 Additional Horizontal Cabling Practices for Open Offices Underwriters Laboratories (UL) 1. 1581 Reference Standard for Electrical Wire, Cable, and Flexible Cords UL-969, Standard for Marking and Labeling Systems 2. 444 Communication Cables SEPTEMBER 30, 2011 C-4

bb. 3. 1690 Data Processing Cable Uniform Building Code (UBC) SEPTEMBER 30, 2011 C-5