These instructions must be left with the user.

Similar documents
MIRA SELECT THERMOSTATIC MIXER INSTALLATION & USER GUIDE. These instructions must be left with the user. 1. Please call us on (UK Only)

These instructions must be left with the user.

Mira Select Flex Thermostatic Mixer

Thermostatic Bar Valve

Mira Reflex Thermostatic Bar Valve

These instructions must be left with the user.

These instructions must be left with the user.

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Thermostatic Bar Valve THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Express Thermo Shower Mixer Set With Handset THE QUALIFICATIONS INSTALLATION INSTRUCTIONS

Mira Realm Thermostatic Mixer

These instructions must be left with the user.

These instructions must be left with the user.

THE QUALIFICATIONS INSTALLATION INSTRUCTIONS NEW SQUARE EXPOSED THERMOSTATIC SHOWER VALVE CHR

These instructions must be left with the user.

THERMOSTATIC SHOWER VALVE

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

These instructions must be left with the user.

Mira Atom ERD Thermostatic Bar Valve

These instructions must be left with the user.

These instructions must be left with the user.

Installation, Operating and Maintenance Guide

These instructions must be left with the user.

These instructions are to be left with the user

Mira Minilite Exposed Mira Minilite EV Mira Moto EV

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Installation, Operating and Maintenance Guide

Telo Shower Mixing Valve TL10016CP

Safetherm PRODUCT MANUAL

Thermostatic Bar Valves

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Plus Bath Shower Mixing Valve CP and PL30020CP

Deluge Shower Mixing Valve 10045CP

Inta City Concealed Shower Mixing Valve CT80010CP

Puro Mini Dual Control Shower Mixer PU90010CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Concealed Shower Mixing Valve

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Mio Concealed Shower Mixing Valve MI40010CP

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Thermostatic bar mixer valve with adjustable head Installation guide

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Dual Control Concealed & Exposed Thermostatic Shower Valve

Avensys Avensys FIN EST SLO RUS UAE

Inta City Shower Mixing Valve CT20010CP

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

Deluge Concealed Shower Mixing Valve DL40010CP

Self-help Temperature Adjustment

Kiko Bath Shower Mixing Valve KK90015CP

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Mira Atom ERD With Moxie

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Kiko Concealed Shower Mixing Valve KK80010CP

Mimosa dual control mixer shower Installation and operating instructions

Dart Eco concentric thermostatic mixer shower

Sema thermostatic bar mixer Installation and operating instructions

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Ambassador. Installation guide & user instructions. Please ensure that this document is handed to the user after installation is completed

Artisan Thermostatic Bath Filler

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Thames thermostatic bar mixer with diverter Installation and operating instructions

Thermostatic mixing valve VADO-PRO-100P

Leona thermostatic bar mixer shower pole Installation and operating instructions

RAMOR Shower Tower Thermostatic mixer Installation and Operating Instructions

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

THAMES. Dual Control. Installation and Operating Instructions. Thermostatic built-in mixer shower

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Dove Eco thermostatic bar mixer shower

MIDAS. Installation instructions 110/220

CROMO manual mixer shower

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Varsity Concealed Shower System

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

AIRE NENE TYNE EXE. Installation and Operating Instructions. bar mixer showers thermostatic. bar mixer shower pressure compensating

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Delphi dual control thermostatic mixer shower Installation and operating instructions

Leona thermostatic bar mixer shower pole Installation and operating instructions

TRIPLE CONTROL THERMOSTATIC SHOWER VALVE

Installation Instructions and User Guide

HART concentric mixer shower

Mira Sport Max with Airboost

ECO EDEN Concentric Thermostatic Mixer Shower

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Oltis thermostatic bar mixer

Transcription:

MIRA SELECT THERMOSTATIC MIXER Installation and User Guide These instructions must be left with the user. 1

CONTENTS Introduction...3 Patents and Design Registration...3 Safety : Warnings...4 Pack Contents...5 Dimensions...7 Specifications...8 Installation Requirements...10 Installation...12 General...12 Installation Methods...13 Exposed Thermostatic Mixer...14 1. Rear Entry Supplies (rising or falling concealed pipework)... 14 2. Rising or Falling Supplies...16 Built-in Thermostatic Mixer...18 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting off Front Face of Wall) 18 2. Solid Wall or Stud Partition (Using Rear Fixing Points on the Thermostatic Mixer)...22 3. Laminated Panel (Using Securing Brackets - Mounting on Rear Face of Wall).24 Control Assembly (Built-in Model)...27 Reversed Inlet Supplies...28 Commissioning...30 Operation...31 Fault Diagnosis...32 Maintenance...33 Type 2 Valves...37 Spare Parts...38 Customer Service...Back Page 2

INTRODUCTION Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Select Thermostatic Mixer is a thermostatic Shower Control with separate flow and temperature controls. The Thermostatic Mixer incorporates a wax capsule temperature sensing unit, which provides an almost immediate response to changes of temperature of the incoming water supplies to maintain the selected showering temperature. An adjustable temperature stop is provided which limits the maximum temperature to a safe level. Inlet Filters are fitted to protect the thermostatic cartridge. Mira Select Exposed: Thermostatic Mixer for connection to rising, falling or rear entry pipework. Mira Select Built-in: Thermostatic Mixer for connection to concealed pipework. Includes Right Angle Connector (RAC) for connecting concealed pipework to exposed shower fittings. This product has been certified as a Type 2 valve under the BUILDCERT TMV2 scheme. This product also complies with the water supply (water fittings) regulations 1999. Optimum performance of the Mira Select is achieved when used together with the Mira Select Shower Fittings. Patents and Design Registration Design Registration: 000578463-0004, 000578463-0005, 00578463-0006. Patents: GB: 2 291 693, 2 392 225, 2 421 297. Patent Applications: GB: 0512457.3. Euro: 1 672 257, 03254070.0. If you experience any diffi culty with the installation or operation of your new Thermostatic Mixer, please refer to Fault Diagnosis, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide. 3

SAFETY : WARNINGS This Mira Select Thermostatic Mixer is precision engineered and should give continued safe and controlled performance, provided: 1. It is installed, commissioned, operated and maintained in accordance with the manufacturer s recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. Caution! 1. Read all instructions. 2. Retain this guide for later use. 3. Pass on this guide in the event of change of ownership of the installation site. 4. Follow all warnings, cautions and instructions contained in this guide. 5. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young, the elderly, the infi rm or anyone inexperienced in the correct operation of the controls. 6. When this product has reached the end of its serviceable life, it should be disposed of in a safe manner and in accordance with the current local authority recycling or waste disposal policy. 4

PACK CONTENTS Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. Exposed Select Thermostatic Mixer 1 x Mira Select Shower Control 2 x Concealing Plates 2 x Compression Nuts 1 x O Key 2 x Olives 1 x Flow Regulator, 12 L/Min 1 x Hexagon Key, 2.5 mm 2 x Screws, No 8 x 1 ¼ 2 x Wall Plugs Documentation 1 x Installation and User Guide 1 x Installation Template 5

Built-in Select Thermostatic Mixer 1 x Mira Select Shower Control (attached to the Building-in Shroud) 1 x Control Assembly 3 x Compression Nuts 3 x Olives 1 x O Key 1 x Hexagon Key, 2.5 mm 2 x Wall Plugs 1 x Flow Regulator, 12 L/Min 2 x Securing Brackets 2 x Screws, No 8 x 1 ¼ 2 x Bracket Screws 2 x Screws, 1 x Right Angle Connector M5 x 40 mm Assembly (RAC) Documentation 1 x Installation and User Guide 6

Exposed Select Thermostatic Mixer DIMENSIONS 134 149-154 Ø71 114 Ø56 35 Built-in Select Thermostatic Mixer 30 67-85 71 Ø183 Building-in Depth All dimensions are in mm. 7

Operating Parameters SPECIFICATIONS For Type 2 valves, the supply conditions specifi ed in section: Type 2 Valves - Application take precedence over the operating parameters which follow. Pressures Maximum Static Pressure: 10 bar. Maximum Maintained Pressure: 5 bar. Minimum Maintained Pressure (Gas Water Heater): 1.0 bar. Minimum Maintained Pressure (Gravity System): 0.1 bar. (0.1 bar = 1 metre head from the base of the cold tank to the outlet of the shower handset.) Note! For optimum performance the inlet pressures should be nominally equal and should not exceed 3:1, in favour of either supply, during fl ow. Temperatures Factory Preset Shower Blend Temperature: 43 C. Optimum Thermostatic Control Range: 35 C - 45 C. (Achieved with supplies of 15 C cold, 65 C hot and nominally equal pressures.) Maximum Hot Supply: 85 C. Recommended Hot Supply: 60 C - 65 C. Minimum differential between Hot Supply and set Blend Temperature: 10 C. Cold Water Range: 1 C - 20 C. Note! BS:6700 recommends that the temperature of stored hot water should never exceed 65 C. A temperature of 60 C is considered suffi cient to meet all normal requirements and will minimise the build up of scale in hard water areas. Connections Exposed Mixer: Inlets: 15 mm Compression, Hot - Left, Cold - Right. Outlet: ½ BSP Flat Face, Bottom - Outlet. Built-in Mixer: Inlets: 15 mm Compression, Hot - Left, Cold - Right. Outlet: 15 mm Compression, Top - Outlet. If reversed inlets are required refer to section: Reversed Inlet Supplies. Thermostatic Shut-down For safety, the thermostat will shut off the Hot Supply within 2 Seconds if the Cold Supply Fails. (Achieved only if the hot supply temperature is greater than 10 C above the set blend temperature.) 8

Flow Rates Typical Flow Rates on Low Pressure Systems (0.1 bar to 1 bar) - Mira Select with Mira Select Adjustable Fittings or Rigid Head: Supply Pressure (bar) Typical Flow Rates on High Pressure Systems (1 bar to 5 bar, with 12 Litre/Min. Flow Regulator fitted in shower control outlet) - Mira Select with Mira Select Adjustable Fittings or Rigid Head: Supply Pressure (bar) 9

Key to Symbols INSTALLATION REQUIREMENTS Float Valve Isolating Valve Thermostatic Mixer Overflow Indicator Pressure Reducing Valve Twin Impeller Pump Single Impeller Pump Tempering Valve Mini Expansion Vessel The Mira Select Thermostatic Mixer is compatible with the following systems: Gravity fed system The Shower Control MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressures. Gas heated system The Shower Control MUST be installed with a gas water heater or combination boiler of a fully modulating design. Note! We recommend the use of a 12 L/Min. Outlet Flow Regulator (supplied). However, it is possible following the installation of the Flow Regulator that the flow rate is reduced too much for the boiler to ignite. If this is the case remove the Flow Regulator. 10

Unvented mains pressure system The Shower Control can be installed with an unvented stored hot water cylinder. Note! We recommend the use of a 12 L/Min. Outlet Flow Regulator (supplied). Mains pressurised instantaneous hot water system (thermal store) The Shower Control can be installed with systems of this type that have balanced pressures. Note! We recommend the use of a 12 L/Min. Outlet Flow Regulator (supplied). Pumped system The Shower Control can be installed with an inlet pump (twin impeller). The pump must be installed on the floor next to the hot water cylinder. Note! We recommend the use of a 12 L/Min. Outlet Flow Regulator (supplied). 90 30-60 Air Separation 11

General INSTALLATION The installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. The installation must comply with the Water Supply Regulations 1999 (Water Fittings) or any particular regulations and practices as specified by the local water company or water undertakers. Note! Make sure that all site requirements correspond to the information given in section: Specifications. For further details on Type 2 valves refer to supply conditions in section: Type 2 Valves. 1. The Mixer must not be installed in an area where it may freeze. 2. For stud partitions, alternative fi xings may be required. 3. Isolating valves must be installed close to the Shower for ease of maintenance. 4. Pipework must be rigidly supported. Avoid any strain on the connections. 5. Pipework dead-legs should be kept to a minimum. 6. Supply pipework layout should be arranged to minimise the effect of any other outlet draw off upon the dynamic pressures at the Shower inlets, e.g. flushing toilet. This is particularly important for gravity fed installations. 7. Inlet and outlet threaded joint connections should be made with PTFE tape or liquid sealant. Do not use oil-based, non-setting joint compounds. 8. To eliminate pipe debris, it is essential that supply pipes are thoroughly fl ushed through before final connection. 9. Decide on a suitable position for the Mixer. The position of the Mixer and the Shower Fittings must provide a minimum gap of 25 mm between the spill-over level of the shower tray/bath and the handset. This is to prevent back-siphonage. For further information on the installation of the Shower Fittings, refer to the Shower Fittings Installation and User Guide. Note! Only use Shower Fittings recommended by the manufacturer or supplier. Hose Retaining Ring 25 mm Spill Over Level 12

Installation Methods Exposed Select Thermostatic Mixer The Exposed Select Mixer can be installed with rear, rising or falling supply inlets. The exposed model has inlet elbows which adjust between 149 mm - 154 mm. This feature assists the installation onto misaligned pipework. For rear entry supplies, refer to section: Exposed Thermostatic Mixer, 1. Rear Entry Supplies for further details. For rising or falling supplies, refer to section: Exposed Thermostatic Mixer, 2. Rising or Falling Supplies for further details. Rear Entry Supplies Rising or Falling Supplies Built-in Select Thermostatic Mixer The Built-in Select Mixer can be installed with rising or falling supply inlets (rising inlets are illustrated). The unit can be installed using the rear fi xing points, or by using the Securing Brackets (supplied) on the front surface of a solid wall or stud partition, or on the rear surface of a laminated panel. For an installation into a solid wall or stud partition using the Securing Brackets, refer to section: Built-in Thermostatic Mixer, 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting on Front Face of Wall) for further details. For an installation into a solid wall or stud partition using the rear fixing points, refer to section: Built-in Thermostatic Mixer, 2. Solid Wall or Stud Partition (Using Rear Fixing Points on Thermostatic Mixer) for further details. For an installation behind a laminated panel using the Securing Brackets, refer to section: Built-in Thermostatic Mixer, 3. Laminated Panel (Using Securing Brackets - Mounting on Rear Face of Wall) for further details. 13 Securing Brackets (mounting on front surface of wall) Mounting using rear fi xing points Securing Brackets (mounting on rear surface of wall)

Exposed Thermostatic Mixer 1. Rear Entry Supplies (rising or falling concealed pipework) 1.1 Use the Installation Template to mark the positions of the holes for the Backplate and the pipe centres. Note! Allow a minimum of 150 mm either side of the unit, to allow access to the hot and cold Inlet Filters for servicing. 150 mm 153 mm 150 mm Bend tabs inwards Use as a support for the spirit level Hot Supply Inlet (Ø15 mm) 153 mm 40 mm Shower Control Backplate Fixing Points (Ø6 mm) Make sure that supply pipes are thoroughly flushed through before connection to the shower control Cold Supply Inlet (Ø15 mm) Bend tabs inwards Use as a support for the spirit level 40 mm 1.2 For solid walls drill the holes for the Backplate with a 6 mm diameter drill and insert the Wall Plugs (supplied). For other types of wall structure alternative fixings may be required (not supplied). 1.3 Drill the holes for the supply pipes at 153 mm centres. 1.4 Create a recess in the wall to allow for the Concealing Plates, 32 mm diameter x 10 mm deep. Note! Depth must be sufficient to prevent the Concealing Plates fouling on the plumbing Elbows. 1.5 Fit the supply pipework (Hot - Left, Cold - Right). The pipework must project 13 mm from the finished wall surface at 153 mm centres (use the Installation Template as a guide). Note! If the connections are reversed, complete the installation then refer to section: Reversed Inlet Supplies before commissioning. 13 mm from finished wall surface Backplate Cold Ø32 mm x 10 mm depth for Concealing Plates 32 mm Elbow 10 mm minimum between elbow and finished wall surface Hot 153 mm Apply Silicone Sealant Concealing Plates 14

1.6 Loosen the Grubscrew with the 2.5 mm Hexagon Key (supplied) and remove the Backplate from the unit. 1.7 Secure the Backplate to the wall using the Screws (supplied). 1.8 Fit the Concealing Plates. Note! Apply silicone sealant to the back face of the fl ange. Caution! It is essential at this point that the supply pipework is thoroughly flushed through before connection to the unit. Failure to do so may result in product malfunction. 1.9 Fit the Compression Nuts and Olives onto the pipework. 1.10 Align the unit with the pipework and fi t onto the Backplate. Minor misalignment of the pipework can be accommodated by the inlets, which are adjustable between 149 and 154 mm centres. 1.11 Tighten the Compression Nuts onto the Elbows with a suitable spanner. Caution! Take care not to damage the chrome surfaces. Cold Hot Grubscrew Flow Regulator (for high pressure systems) 1.12 Tighten the Grubscrew to secure the unit to the Backplate. 1.13 Fit the Shower Fittings. Refer to Shower Fittings Installation and User Guide for instructions. Note! For high pressure systems, a 12 litre/minute white Flow Regulator (supplied) can be fitted under the Hose Washer (refer to illustration). 1.14 Turn on the hot and cold water supplies and check for leaks. 1.15 Before using the Shower, refer to section: Commissioning for testing the unit is operating correctly. 15

2. Rising or Falling Supplies 2.1 Loosen the Grubscrew on each Elbow using the 2.5 mm Hexagon Key (supplied) and rotate the Elbow 90 as required. Retighten the Grubscrews. 2.2 Use the Installation Template to mark the positions of the fixing holes for the Backplate. Note! Allow a minimum of 150 mm either side of the unit to allow servicing of the hot and cold Inlet Filters. 150 mm 150 mm 153 mm Bend tabs inwards Use as a support for the spirit level Hot Supply Inlet 153 mm 40 mm Shower Control Backplate Fixing Points (Ø6 mm) Cold Supply Inlet Bend tabs inwards Use as a support for the spirit level 35 mm 35 mm (Ø15 mm) Make sure that supply pipes are thoroughly flushed through before connection to the shower control (Ø15 mm) 40 mm 35 mm 2.3 For solid walls, drill the holes for the Backplate with a 6 mm diameter drill and insert the Wall Plugs (supplied). For other types of wall structure, alternative fixings may be required (not supplied). 2.4 For both rising and falling supplies: Using the Installation Template as a guide, mark the pipe positions on the ceiling and set the centres 35 mm from the finished wall (refer to illustration). 153 mm Wall Plugs 16

2.5 Fit the supply pipework (Hot - Left, Cold - Right). Note! If the connections are reversed, complete the installation then refer to section: Reversed Inlet Supplies before commissioning. 2.6 Loosen the Grubscrew with the 2.5 mm Hexagon Key (supplied) and remove the Backplate from the Mixer. 2.7 Secure the Backplate to the wall using the Screws (supplied). Caution! It is essential at this point that the supply pipework is thoroughly flushed through before connection to the unit. Failure to do so may result in product malfunction. 2.8 Fit the Compression Nuts and Olives onto the pipework. 2.9 Align the unit with the pipework and fit onto the Backplate. Minor misalignment of the pipework can be accommodated by the inlets, which are adjustable between 149 and 154 mm centres. 2.10 Tighten the Compression Nuts onto the Mixer with a suitable Spanner. Caution! Take care not to damage the chrome surfaces. 2.11 Tighten the Grubscrew to secure the unit to the Backplate. 2.12 Fit the Shower Fittings. Refer to the Shower Fittings Installation and User Guide for further details. Note! For high pressure systems, a 12 litre/minute white Flow Regulator (supplied) can be fi tted under the Hose Washer (refer to illustration). 2.13 Turn on the hot and cold water supplies and check for leaks. 2.14 Before using the Shower, refer to section: Commissioning for testing the unit is operating correctly. 17 Flow Regulator (for high pressure systems) Grubscrew

Built-in Thermostatic Mixer 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting off Front Face of Wall) 1.1 Determine the route for the hot and cold supply pipework and for the outlet pipework. When connecting to the BIV Shower Fittings it is recommended that the outlet be positioned above and to one side of the unit. This is to prevent the Flexible Hose from obstructing the Shower Controls. 1.2 Remove the two Shroud Screws (retain for later use) and separate the unit from the Building-in Shroud. 1.3 Determine the position of the unit and draw around the Building-in Shroud. 1.4 Mark the routes for the hot and cold supply pipework at 108 mm centres (Hot - Left, Cold - Right). Falling supplies: For falling supplies loosen the Grubscrew on each Elbow using the 2.5 mm Hexagon Key (supplied). Remove the Elbows and install on opposite sides. Retighten the Grubscrews. Note! Make sure that the O Seals are correctly fitted and that the Filter Plugs are positioned to the front (i.e. hexagonal key hole facing forward). 1.5 Mark the route for the outlet pipework. Note! The Outlet Elbow should be sited above the unit and on the right or left, as site dictates. 1.6 Remove the plasterboard and/or brick work to a minimum depth of 62 mm. 18 Alternative Pipe Layouts Outlet Pipe BIV Thermostatic Mixer Hot Inlet 62 mm Min. Outlet Pipe BIR Outlet Pipe BIV Cold Inlet 6 mm Min. Finished Wall Finished Wall Surface Securing Bracket Shroud Screws (retain for later use) 24 mm Max. Finished Wall

1.7 Fit the Securing Brackets to the unit with the Bracket Screws. Important! Make sure that the correct holes are used, otherwise the Backplate cannot be fitted. Note! The Securing Brackets can be rotated for suitable fixing points. Countersunk Fixing Hole Rotate for Suitable Fixing Point Rear Fixing Point 1.8 Making sure that the unit is level, mark the positions for the countersunk fixing holes on the wall. 1.9 For solid walls, drill two 6 mm diameter holes for the Wall Plugs. Caution! Do not drill into pipes or electrical cables buried in the wall. 1.10 Fit the Wall Plugs provided and fi x the unit to the wall with the Screws provided. Note! For stud partition installations, alternative fi xings may be required (not supplied). Backplate securing hole Note! Securing Brackets shown in preferred position to allow the Compression Nuts to be tightened. Outlet Pipe to Fittings 1.11 Connect the hot and cold supply pipes and tighten the Compression Nuts. Caution! Make sure that the Olives are fitted and all pipework is fl ushed through before connecting to the unit. Screws Cold Supply Hot Supply 19

1.12 Connect the outlet pipework, leaving enough pipe to connect a 1/2 BSP female fitting (not supplied) to the Right Angle Connector (RAC) assembly. Backnut (not supplied) Finished Wall Surface 20 to 22 mm 20 to 22 mm 1.13 When the 1/2 BSP female fitting and brass nipple have been fitted to the outlet pipework, temporarily seal off the open end with an appropriate fitting (not supplied) and turn on the water supplies to check for leaks. 1.14 Attach the Building-in Shroud to the unit using the two Shroud Screws removed earlier. Solid or Dry-lined wall Laminated Panel or Stud Partition wall 1.15 Using the Building-in Shroud as a guide, finish the wall, e.g. tiles. Caution! Make sure that the finished wall is within the maximum and minimum limits and to an even depth (no greater than 2 mm variation) or the control components will not fi t correctly. 1.16 Remove the two Shroud Screws (retain for later use) and remove the Building-in Shroud. Minimum Finished Wall Surface Maximum Finished Wall Surface Finished Wall Min Max F9802 1.17 Fit the Concealing Plate and Control Assembly. Refer to section: Control Assembly for further details. 20

1.18 Apply liquid sealant or PTFE tape to the exposed end of the Brass Nipple. Screw the Mounting Bush on until the Wallplate is loosely clamped against the wall. Then rotate the Wallplate and position as shown to align the arrow and release slot. Tighten the Mounting Bush with a 24 mm A/F spanner. Nipple Foam Seal Wallplate Mounting Bush Arrow 1.19 Push the Elbow fully into the Wallplate and rotate it clockwise. A "click" will indicate when it is locked. To unlock, use a small fl at blade screwdriver and insert it into the release slot on the underside. Then turn the Elbow anticlockwise until it is released from the Wallplate. 1.20 Locate the Shroud over the Elbow, then carefully push until it "clicks" into place securely. Wallplate Release Slot Wallplate Mounting Bush Elbow 1.21 Fit the Shower Fittings. Refer to the Shower Fittings Installation and User Guide for further details. Note! For high pressure systems, a 12 litre/minute white Flow Regulator (supplied) can be fi tted under the Hose Washer. To Lock Release Slot To Unlock RAC Shroud 21

2. Solid Wall or Stud Partition (Using Rear Fixing Points on the Thermostatic Mixer) 2.1 Refer to section: 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting off Front Face of Wall) and follow steps 1.1 to 1.4. Finished Wall Surface 2.2 Cut away the plasterboard and/or brick work to the required depth. Important! This depth X will depend on the finished wall thickness e.g. tiles or facia board. Refer to the table for this measurement. For stud partitions depth X refers to the distance from the rear mounting e.g. timber noggin, to the front of the wall (before tiling). Rear Fixing Depth X Finished Wall Thickness Finished Wall Thickness (e.g. tile and adhesive) Wall Cutout Depth X 4 mm 81-63 mm 6 mm 79-61 mm 8 mm 77-59 mm 10 mm 75-57 mm 12 mm 73-55 mm 14 mm 71-55 mm 16 mm 69-55 mm 18 mm 67-55 mm 20 mm 65-55 mm 22 mm 63-55 mm 24 mm 61-55 mm 22

2.3 Make sure that the unit is level, central in the hole and square to the finished wall surface. This is to make sure the chrome trim and control handles will fit correctly. Then mark the positions of the Fixing Screw holes on the wall. 2.4 For solid walls, drill two 6 mm holes for the Wall Plugs. Outlet Pipe to Fittings Screws 2.5 Insert the Wall Plugs (supplied) and attach the unit to the wall with the Screws provided. Note! For stud partition installations alternative fi xings may be required (not supplied) to fix the unit to the rear face of the wall cavity or to a timber noggin. 2.6 Refer to section: 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting off Front Face of Wall) and follow steps 1.10 to 1.21. Hot Supply Cold Supply 23

3. Laminated Panel (Using Securing Brackets - Mounting on Rear Face of Wall) Note! For laminated panels the unit must be positioned from the rear of the panel. Panel thickness must be between 4 and 12 mm. (If a thicker panel is used, it will be necessary to recess the Securing Brackets into the rear of the panel.) Important! Make sure that there is a minimum clearance of 64 mm behind the laminated panel to accommodate the unit. 3.1 Remove the two Shroud Screws (retain for later use) and separate the unit from the Building-in Shroud. 3.2 Mark the position of the unit using the Building-in Shroud as a guide. 3.3 Carefully cut out the laminated panel. Shroud Screws (retain for later use) 3.4 Fit the Securing Brackets to the unit. Important! The Securing Brackets must be fixed vertically, as illustrated. Important! Make sure that the correct holes are used, otherwise the Backplate cannot be fitted. 3.5 Position the unit on the front of the panel, make sure that it is level and central in the hole, then mark the position of the M5 fixing holes. Important! Make sure that the correct holes are used (refer to illustration). Note! Make sure that the Filter Plugs are positioned so that they can be removed for servicing. Backplate Securing Hole Backplate Securing Hole M5 Fixing Hole Filter Plug M5 Fixing Hole 24

3.6 Drill the two 5.5 mm holes for the fixing positions (countersink the holes at the front). 3.7 Secure the unit with the M5 x 40 mm screws as shown. 3.8 Fit the hot and cold supply pipes (hot - left, cold - right) and tighten the compression nuts. Caution! Make sure that the olives are fitted and all pipework is flushed through before connecting to the unit. Outlet Pipe to Fittings M5 x 40 mm Fixing Screws 3.9 Connect the outlet pipework, leaving enough pipe to connect a 1/2 BSP female fitting (not supplied) to the Right Angle Connector (RAC) assembly. 3.10 When the 1/2 BSP female fitting and brass nipple have been fitted to the outlet pipework, temporarily seal off the open end with an appropriate fitting (not supplied) and turn on the water supplies to check for leaks. 3.11 Fit the Shower Fittings. Refer to the Shower Fittings Installation and User Guide for further details. Note! For high pressure systems, a 12 litre/minute white Flow Regulator (supplied) can be fi tted under the Hose Washer. Backnut (not supplied) Hot Supply Cold Supply Finished Wall Surface 20 to 22 mm 3.12 Fit the Concealing Plate and Control Assembly. Refer to section: Control Assembly for further details. 25

3.13 Apply liquid sealant or PTFE tape to the exposed end of the Brass Nipple. Screw the Mounting Bush on until the Wallplate is loosely clamped against the wall. Then rotate the Wallplate and position as shown to align the arrow and release slot. Tighten the Mounting Bush with a 24 mm A/F spanner. Nipple Foam Seal Wallplate Mounting Bush Arrow 3.14 Push the Elbow fully into the Wallplate and rotate it clockwise. A "click" will indicate when it is locked. To unlock, use a small fl at blade screwdriver and insert it into the release slot on the underside. Then turn the Elbow anticlockwise until it is released from the Wallplate. 3.15 Locate the Shroud over the Elbow, then carefully push until it "clicks" into place securely. 3.16 Fit the Shower Fittings. Refer to the Shower Fittings Installation and User Guide for further details. Note! For high pressure systems, a 12 litre/minute white Flow Regulator (supplied) can be fi tted under the Hose Washer. Wallplate Release Slot Wallplate Mounting Bush Elbow To Lock Release Slot To Unlock RAC Shroud 26

Control Assembly (Built-in Model) Backplate 1. 2. Concealing Plate Flow Lever Bearing Temperature Control Carefully separate the control assembly as shown. Attach the Backplate using the two Shroud Screws removed previously. Tighten the screws until the foam seal is compressed against the fi nished wall. Do not overtighten. 3. 4. Locate the Concealing Plate onto the Backplate and push firmly until it snaps into place. Make sure the slot is at the bottom of the plate. Locate the Flow Lever and push fi rmly into place. Fit the Bearing onto the Flow Lever. Refer to section: Commissioning for final assembly. 27

REVERSED INLET SUPPLIES The Mira Select Thermostatic Mixer is supplied with inlet connections Hot - Left, Cold - Right and Bottom - Outlet as standard. If the hot and cold water supply pipes have been reversed during installation, the Thermostatic Cartridge must be removed and rotated 180. Exposed Model: 1. Isolate the hot and cold water supplies. Remove the Temperature Control Handle with the 2.5 mm Hexagon Key and remove the Flow Control Lever. 2. Remove the Bearing, which will unlock part A. 3. Rotate the white section of part A clockwise by 90 then pull forward to remove. Pull part B forward and remove to get access to the Thermostatic Cartridge. 4. Locate the O Key (supplied) onto the Cartridge Nut and turn anticlockwise. Unscrew fully and pull the Cartridge from the unit. 5. Rotate the Cartridge 180. 6. Make sure that the two Inlet Seals are fi tted and carefully push the Cartridge back into the unit, aligning the lugs into the slots. Note! Check that the Cartridge lug stamped H is aligned with the hot inlet supply. Important! Take care when fi tting the Cartridge. Damage to the Cartridge Inlet Seals may result in dripping from the Shower Head. 7. Tighten the Nut by turning the O Key clockwise. 8. Refi t the controls in reverse order. Make sure the shower operates correctly. Refer to section: Commissioning for further details. Built-in Model: 1. Isolate the hot and cold water supplies. Remove the Temperature Control Handle with the 2.5 mm Hexagon Key. Remove the Bearing and the Flow Control Lever. 2. Carefully unclip the Concealing Plate from the Backplate. Note! Use a suitable screwdriver in the cutout to assist separation. 3. Unscrew the two Shroud Screws and remove the Backplate. Pull red part B forward and remove to get access to the Thermostatic Cartridge. 4. Locate the O Key (supplied) onto the Cartridge Nut and turn anticlockwise. Unscrew fully and pull the Cartridge from the unit. 5. Rotate the Cartridge 180. 6. Make sure that the two Inlet Seals are fi tted and carefully push the Cartridge back into the unit, aligning the lugs into the slots. Note! Check that the Cartridge lug stamped H is aligned with the hot inlet supply. Important! Take care when fi tting the Cartridge. Damage to the Cartridge Inlet Seals may result in dripping from the Shower Head. 7. Tighten the Nut by turning the O Key clockwise. 8. Refi t the controls in reverse order. Make sure the shower operates correctly. Refer to section: Commissioning for further details. 28

Exposed Model Flow Control Lever Temperature Control Handle Bearing O Key B A Hub Cartridge Seal Built-in Model B Concealing Plate Backplate O Key Cartridge Seal 29

Maximum Temperature Setting COMMISSIONING Before using the shower, the maximum temperature level must be checked to make sure that it is safe. It has been preset to approximately 43 C at the factory, but due to variations in site conditions the maximum temperature may need adjustment. Note! Make sure that the hot water temperature is at least 55 C and that there is a sufficient supply. Turn on the shower to maximum fl ow and temperature (i.e. both controls fully anticlockwise) and allow the temperature to stabilise. If the temperature is too hot or too cold adjust as follows: 1. Using the 2.5 mm Hexagon Key provided, unscrew and remove the Temperature Control Handle 2. Insert the 2.5 mm Hexagon Key into the centre of the Green Hub and engage with the hidden Temperature Adjust Screw. 3. Turn the Hexagon Key until the required maximum showering temperature is obtained. Turn anticlockwise to increase or clockwise to decrease the temperature (¼ turn = approximately 1 C). 4. Once the desired maximum blend temperature has been achieved, turn off the shower. 5. Refit the Temperature Control Handle. 6. Check that the showering temperature is correct. If the correct temperature setting cannot be achieved, refer to section: Fault Diagnosis for possible cause and rectification. + - + - Temperature Handle 30

OPERATION Shower Control (Exposed and Built-in Controls) Note! The shower performance may be affected if other water appliances are operated whilst the shower is in use. OFF Turn the Flow Lever anticlockwise to the preset maximum fl ow ON Turn the Temperature Control Handle clockwise to decrease the temperature and anticlockwise to the preset maximum temperature Caution! Do not force the Temperature Control Handle. If the desired temperature cannot be achieved, refer to the section Commissioning for maximum temperature adjustment. 31

FAULT DIAGNOSIS Symptom 1. Only hot or cold water from the outlet. 2. Fluctuating or reduced fl ow rate. 3. No fl ow from the outlet. 4. Blend temperature drift. 5. Maximum blend temperature setting too hot or too cold. 6. Water leaking from the Showerhead. 7. Flow rate too low or too high. Cause / Rectification a. Inlets reversed (hot supply to cold supply). Refer to section: Reversed Inlet Supplies for further details. b. No hot water reaching the unit. c. Check the Filters for any blockage. d. Installation conditions outside operating parameters: refer to sections: Specifications and Commissioning for further details. a. Check the Showerhead, Hose and Filters for any blockage. b. Make sure the maintained inlet pressures are nominally equal and sufficient. Refer to section: Specifications for further details. c. Make sure the inlet temperature differentials are sufficient. Refer to section: Specifications for further details. d. Flow Regulator fi tted incorrectly. e. Airlock or partial blockage in pipework. a. Check the Showerhead, Hose and Filters for any blockage. b. Hot or cold supply failure. a. Refer to symptom 2 above. b. Signifi cant supply temperature fl uctuation. c. Signifi cant supply pressure fl uctuation. d. Faulty Thermostatic Cartridge. Renew. a. Indicates incorrect maximum temperature setting. Refer to section: Commissioning for further details. b. Refer to symptom 4 above. a. Normal for a short period after shut off. b. Check that the pressures are not in excess of the specifications for product. Refer to section Specifications for further details. c. Cartridge Inlet Seals damaged. Renew. d. Faulty Thermostatic Cartridge. Renew. a. (Low) Insuffi cient supply pressures. b. (High) Supply pressure too high. Install Flow Regulator. c. Refer to symptom 2 above. 32

MAINTENANCE General This product is precision engineered and should give continued safe and controlled performance provided that: 1. It is installed, commissioned, operated and maintained in accordance with the manufacturer s recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. The Mira Select Thermostatic Mixer is designed to require the minimum of maintenance in normal use. The only serviceable parts are the inlet fi lters which should be checked and cleaned every 12 months. Refer to section Maintenance, Filters for further details. If a malfunction occurs with the Thermostatic Cartridge, this will necessitate a complete cartridge replacement. Note! The cartridge contains no internally serviceable parts. If you require a Mira trained engineer or agent, then refer to section: Customer Service on the back of this guide. Lubricants Silicone based lubricants must only be used on the rubber seals. Warning! Oil based or other lubricant types may cause rapid deterioration of the seals. Cleaning The chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth. Warning! Many household cleaners contain abrasive or chemical substances and should not be used for cleaning plated or plastic fi ttings. Do not use descalents on this product. In-service Tests The primary method for determining the continued satisfactory performance of the mixing valve is the in-service test. Follow the procedure detailed in the fl ow diagram In-Service Test Procedure for further details. Frequency of In-Service Tests - Commercial (non-domestic installations) Check for correct blend setting every 6 months. Follow the procedure detailed in the fl ow diagram In-Service Test Procedure every 12 months. 33

Start Measure and record supply temperatures and pressures, making sure that they are within the valve specifi cation. Measure and record blend temperature (Tb) and fl ow rate. Has fl ow rate fallen signifi cantly or fallen below minimum fl ow specifi cation? No Yes Check and clean checkvalves, strainers and outlets. Measure and record blend temperature (Tb) and fl ow rate. Yes Has fl ow rate improved? No Carry out a Performance Check. Refer to the Commissioning Procedure. Has blend temperature changed by more than 2 C from previous recorded value (Tb)? No Yes Refer to Fault Diagnosis Carry out the Commissioning Procedure. Finish Note! All measurements and results should be recorded in the Log Book. Flow diagram In-service Test Procedure 34

Inlet Filters The Inlet Filters should be checked and cleaned as necessary every 12 months. Note! The Inlet Filters must not be removed except for cleaning. If the unit is operated without the Inlet Filters fitted, the warranty on the product will be void. Exposed Models 1. Isolate the hot and cold water supplies and operate the Flow Control Lever to drain any residual water. 2. Carefully remove the Filter Caps and unscrew the Filter Plugs with the O Key (supplied) or a 12 mm hexagonal wrench. Remove the Filters. 3. Clean the Filters under a jet of water to remove any lodged particles. 4. Refit the Filters and tighten the Filter Plugs. Note! Make sure that the O seal is fi tted correctly and undamaged. 5. Turn on the hot and cold water supplies and check for leaks. 6. Refit the Filter Caps. Filter Cap Filter Plug O Seal Filter 35

Built-in Models 1. Isolate the hot and cold water supplies and operate the Flow Control Lever to drain any residual water. 2. Loosen the Grubscrew to remove the Temperature Control Handle. Then remove the Flow Control Lever. 3. Carefully unclip the Concealing Plate from the Backplate. Note! Use a suitable screwdriver in the cutout to assist separation. 4. Unscrew the two Shroud Screws and remove the Backplate from the Mixer. 5. Unscrew the Filter Plugs with the O Key (supplied) or a 12 mm hexagonal wrench and remove the Filters. Note! Use pliers to remove the filters carefully. 6. Clean both fi lters under a jet of water to remove any lodged particles. 7. Refit the Filters and tighten the Filter Caps. Note! Make sure that the seal is fitted correctly and undamaged. 8. Turn on the hot and cold water supplies and check for leaks. 9. Refer to section: Control Assembly (Builtin Models) and follow the instructions to replace the Concealing Plate and Handles. 36

TYPE 2 VALVES Application The approved designations for Type 2 valves are as follows: Model Mira Select Designation Code HP-S / LP-S The permitted application details are: Designation HP-S Operating Pressure Range High Pressure Application Shower Mixed Water Temperature C 41 C maximum LP-S Low Pressure Shower 41 C maximum Mixed water temperature at discharge point. In order to achieve the safe water temperatures expected of a Type 2 valve, it is essential that the unit is used only for the applications covered by its approved designations, with the appropriate water supply pressures and temperatures. It must be commissioned, maintained and serviced in accordance with the recommendations contained in this guide. Refer to section Maintenance, In-Service Tests for the in-service test frequency that must be used as a minimum guide in Type 2 installations. Supply Conditions For applications where a Type 2 valve is required, the supply conditions must comply with the values in the table below. Note that both hot and cold supply pressures must lie within the same pressure range. Supply Conditions Maximum Static Pressure - bar Maintained Pressure, Hot and Cold - bar Hot Supply Temperature - o C Cold Supply Temperature - o C High Pressure HP 10 1 to 5 55 to 65 < 25 Low Pressure LP 10 0.2 to 1 55 to 65 25 Caution! The mixed water temperature at the terminal fitting should never exceed 46 C. Units operating outside these conditions cannot be guaranteed to operate as Type 2 valves. 37

Exposed Select Thermostatic Mixer SPARE PARTS 090.95 Pipe concealing plate (x 2) 1062476 Backplate 1062477 Filter Pack (x 2) 1062478 Elbow Connector Pack 1062479 Outlet Connector Pack 1592.080 Handle Pack 1592.081 Handle Adaptor Pack 1592.082 Elbow Assembly 1592.083 Adjustable Inlet 1592.084 Filter Cap (x 2) 1592.085 Seal Pack (identified A ) 1595.036 Temperature Hub Assembly 1595.039 Cartridge Assembly 1595.067 Screw Pack (identified B ) 1595.231 O Key 090.95 (2 off) 1062478 B 1592.083 A 1062477 (2 off) 1592.084 (2 off) 1062476 B A 1595.039 1592.082 1062479 A A 1592.080 1595.036 B 1592.081 1595.231 B 38

Built-in Select Thermostatic Mixer 411.22 RAC Mounting Pack 411.66 Brass Nipple 413.57 RAC Shroud-chrome 1592.086 Flow Lever Adaptor Pack 1592.087 Concealing Plate Assembly 1592.088 Handle Pack 1592.231 O Key 1595.036 Temperature Hub Assembly 1595.039 Cartridge Assembly 1595.046 Seal Pack (identified A ) 1595.066 Filter Pack (x 2) 1595.067 Screw Pack (identified B ) 1595.070 Component Pack 1595.149 Outlet Connector Pack 1595.150 Elbow Assembly A 1595.149 B A 1592.150 1595.066 (2 off) A 411.22 411.66 413.57 1595.039 1595.086 1592.087 1595.036 B 1595.231 1592.070 B 1592.088 39

CUSTOMER SERVICE 1066764-W2-B (1592) (B92F, B92G) Kohler Mira Limited, February 2007 40