ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

Similar documents
ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Complete the table to show which size fuse, 3 A or 13 A, should be fitted to each of the appliances. Appliance Power Fuse

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Q1. Carefully read the following extract from a safety leaflet. Then answer the questions.

Electrical Management

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co.

Level 1 Physics, 2013

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

Electrisaver User and Installation Instructions

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Electrical safety tips

NZECP 12:1993 ISSN COVER PAGE

NAME:... HEATING EFFECT OF ELECTRIC CURRENT. Page 1

Mains Power Filter 970MF10 970MF20. Installation Instructions

Electrical Safety Tips. Help us keep you safe.

ELECTRIC FIRE PUMP CONTROLLER

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

UEE30811 Q-Tracker Work Tasks

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

RE-PR3-E-27 3-Phase Panel Mount 27kW

Page 1 of Relevant Provincial Jurisdictional legislation.

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Residual Current Devices

User Information Sheet 008 : 2010

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

INTERNATIONAL STANDARD

Course outline: 442 Capstone G105A UEENEEG105A - Verify compliance and functionality of low voltage general electrical installations

Level 1 Physics, 2016

SUBMERSIBLE WATER PUMPS

120 APPLIANCE MAINTENANCE

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Contractor Worksheet Underground Fires Major Hazard Standard

Consumer unit replacement in domestic and similar premises

Instruction Sheet 00 Variable Speed Delta T (00-VDT)

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Employee Safety Toolkit. Notes:

3KW ELECTRIC FAN HEATER

Residual Current Devices. Switching on to Safety

Training, Assessment, Consultants for Hazardous & Industrial Areas

DIRTY WATER SUBMERSIBLE PUMP

Electronic 7 Installation Instructions

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

DIRTY WATER SUBMERSIBLE PUMP KIT

Q1. The diagram shows the inside of a mains plug. Label the earth, live and neutral pins.

BS Outcomes 6

SPECIFICATION, INSTALLATION AND OPERATION MANUAL. Heat Lamp Assemblies. Models: W.HLA900, W.HLA1200 & W.HLA1500

INSTALLATION, OPERATION & MAINTENANCE MANUAL

NON-SUBMERSIBLE WATER PUMP

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

NZQA registered unit standard version 1 Page 1 of 5

Science 10-Electricity & Magnetism Activity 14 Chapter 5 Review

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

MANUFACTURER OF LT PANELS

2.8KW ELECTRIC FAN HEATER

1.7. Insulation fault evaluators EDS460/490 EDS461/491

>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.

DEVIL CERAMIC SPACE HEATERS

Trade of Electrician. Fixed Appliance and Socket Circuits COURSE NOTES

Australian/New Zealand Standard

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

PANTHER. Condensate removal pump Installation and operating guide

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Australian/New Zealand Standard

OPERATION & MAINTENANCE INSTRUCTIONS

National Electrical Code

NZECP 19: 1994 ISSN COVER PAGE

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Cambridge National Engineering. Mark Scheme for January Unit R113: Electronic principles

INSTALLATION AND USER MANUAL

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Portable Generator Safety Lloyd Shank, P.E. Director of Electric and Gas Utilities 4/12/2005

Welcome to Hager Presentation

AS/NZS 3190:2011 AS/NZS

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

Inverter Swimming Pool Heat Pump

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer,

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

SUBMERSIBLE DIRTY WATER PUMP

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Transcription:

Candidate Code No. EIN 11 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER THEORY EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY You have 10 minutes to read this paper but do not start writing until you are told to do so by the supervisor. Write your Candidate Code Number in the box provided above. Your name must NOT appear anywhere on this paper. Answer all questions. The pass mark for this examination is 60 marks. Use a pen for written answers. Do not use a pencil or a red pen. Drawing instruments and pencils may be used when diagrams are required. Marks are allocated on the basis of correctness. Do not use correcting fluid or correcting tape. For calculation questions all workings, including formulae, must be shown to gain full marks. Candidates are not permitted to use any Act, Regulation, Standard, Code of Practice, Handbook or other reference text in this examination. PLEASE HAND THIS PAPER TO THE SUPERVISOR BEFORE LEAVING THE ROOM.

Question 1 (a) State ONE reason why the metal frame of a Class I electrical appliance is connected to a protective earthing conductor. (b) State TWO factors that determine the severity of electric shock upon the human body. (1) (2) (c) (i) State the maximum permitted rated residual current of an RCD installed for personal protection in a domestic electrical installation. (ii) State the maximum permitted rated residual current of an RCD installed for personal protection in a medical-electrical installation. 2

Question 1 continued (d) In the New Zealand MEN system the neutral is earthed at the star point of a transformer; on the distribution system; and at the main switchboard of an electrical installation. State TWO reasons why the neutral is earthed in the New Zealand MEN system. (1) (2) (e) (i) State TWO types of fault for which MCB protection is installed. (1) (2) (ii) Explain the term AC 80 as found on a HRC fuse cartridge. 3

Question 1 continued (f) State ONE reason why a run capacitor is fitted to a single-phase induction motor. (g) A 230V/240V electric heater is rated at 2 kw when operated at 230V. The heater incorporates one 26.45Ω element. Calculate the power output of the heater when supplied at 240V. (h) A worker is using a 230V, Class I electrical appliance with a portable residual current device (PRCD). The PRCD has operated. Explain why the worker does not sustain a severe electric shock. 4

Question 1 continued (i) Draw a power triangle that shows VAr, VA, W and a lagging phase angle (Φ). (j) (i) Which device provides the starting torque in a single-phase capacitorstart induction motor? (ii) How is the device stated in (j)(i) connected? 5

Question 2 (a) The figure below represents the metal frame of a 230V, Class I, portable electrical appliance. Draw and label the supply to the components in the appliance. Draw and label the following components within the metal frame: A fuse that protects the appliance. A single-pole switch that controls the appliance. Element 1 is 50Ω and is connected closest to the switch. Element 2 is 20Ω and Element 3 is 50 Ω. These elements are connected in parallel. This parallel group is connected in series with Element 1. (5 marks) Metal frame of the Class I Electrical Appliance 6

Question 2 continued (b) Calculate the power dissipated by the Class I portable electrical appliance when it is operating at 230V. (5 marks) 7

Question 3 Introduction A three-phase fixed-wired induction motor running an industrial refrigeration plant is protected by HRC fuses on a switchboard. The motor requires new bearings. The motor is controlled by a DOL starter and an adjacent lockable isolating switch. The isolating switch has a broken operating handle and cannot be used. You are required to: Remove the three-phase motor, by disconnecting the cable at the motor. Replace the isolating switch. Leave the site safe while the motor is being repaired. Use the information in the introduction to this question to answer parts 3(a), 3(b) and 3(c). (a) Describe how to isolate the motor and isolating switch. (4 marks) 8

Question 3 continued (b) The motor has been isolated, the isolator replaced and the motor disconnected. (i) State ONE method of ensuring that the isolation remains effective while the motor is being repaired. (ii) State TWO actions that must be taken to ensure that the work area is safe to be left unattended. (1) (2) 9

Question 3 continued (c) The motor has been repaired and is ready to be reconnected (i) State the TWO instrument tests that need to be carried out on the motor before it is reconnected. (1) (2) (ii) State what action a registered electrical installer needs to take to ensure that it is safe to reconnect the motor. 10

Question 4 (a) Draw and label a diagram of a MEN distribution system showing only the neutral and earthing arrangements between a delta-star-connected 11 kv/400 V supply transformer and a single-phase consumer switchboard (4 marks) 11

Question 4 continued (b) State TWO factors that determine the level of the prospective short-circuit current in an electrical installation. (1) (2) (c) The protective devices on the switchboard of an electrical installation are rated lower than the level of prospective short-circuit current of the installation. Describe TWO conditions that could occur in the installation when a high fault current occurs. (4 marks) (1) (2) 12

Question 5 (a) Two registered electrical installers are carrying out electrical repairs on the same refrigeration plant. (i) State ONE reason why each installer attaches their own danger tag to the point of isolation of the refrigeration plant. (ii) State THREE actions each installer must take when attaching their own danger tag to the isolation point of the refrigeration plant. (3 marks) (1) (2) (3) (b) Describe the circumstances where an out-of-service tag is used. 13

Question 5 continued (c) State the TWO reasons why the prove test prove method of voltage testing for isolation is used. (1) (2) (d) You are doing a polarity test at the supply side of a three-phase main switch to see if the switchboard is isolated. Between which terminals would you test to clearly establish that isolation (or otherwise) has taken place. (e) An electrical installer intends to isolate a faulty permanently-connected three-phase electric motor, but has withdrawn the wrong HRC fuses for that motor on the factory switchboard. State ONE dangerous condition that could occur because the electrical installer withdrew the wrong HRC fuses other than the faulty motor remaining live. 14

Question 6 (a) The figure below represents the components of the power circuit of a DOL forward and reverse starter. On the figure draw the conductors so the motor can be operated in the forward and reverse directions. Overload protection for the motor must operate in either direction. (5 marks) L1 L2 L3 Forward Reverse V U W M 15

Question 6 continued (b) A 400V, three-phase induction motor is controlled by a DOL starter. When started, the motor draws 90A and produces 200% full-load torque. (i) Calculate the starting current if the same motor is started with a star/delta starter. (ii) Calculate the percentage (%) of starting torque if the same motor is started with an auto-transformer starter with an 80% tap. (c) Explain the term ramp time as it relates to an a.c. variable speed controller. 16

Question 7 (a) Draw and label a circuit diagram of a single-phase, 230V RCD used for personal protection. Include the Class I electrical equipment as the load. The RCD must include all the components necessary to allow the RCD to be deemed electrically safe. (4 marks) Class I electrical equipment 17

Question 7 continued (b) A Residual Current Circuit Breaker (RCCB) is installed for the protection in a single-phase final subcircuit. State the ONE reason why is it necessary to have additional electrical protection in that circuit? (c) Explain why Portable Residual Current Devices (PRCDs) used in New Zealand are voltage dependent. (d) State the reason why Type AC RCDs are prohibited from being used in New Zealand. 18

Question 7 continued (e) The phase and neutral on the supply side of a single phase RCD have been transposed. Would the RCD operate if it detected an earth leakage fault on the circuit that the RCD protects? State a reason to support your answer. (f) Would an RCD operate if there was a short between neutral and earth on the final subcircuit that the RCD protects? State a reason to support your answer. 19

Question 8 (a) The figure below is a delta-connected heater supplied from a 400V, threephase supply. R2 R3 RI Each element has a resistance of 20 Ω (i) Use the information in the introduction to calculate the reading on the ammeter when the heater is fully operational. (4 marks) 20

Question 8 continued (ii) Use the information in the introduction to calculate the reading on the ammeter if Fuse F3 was removed and the heater was switched on. (4 marks) (iii) State the minimum size HRC fuses that would be used to protect the heater. (b) A heater is rated at 2 kw when operating at 230V. (i) What effect will a voltage drop of 5% have on the resistance of the heater elements? (½ mark) (ii) By how much will the power dissipated by the heater change if the voltage drops 5%. (½ mark) 21

Question 9 (a) State what is meant by the term testing as it applies to electrical work. (b) You are using a clip-on (clamp) ammeter to measure the current drawn by a live electrical appliance. (i) State where on the appliance the clip-on (clamp) ammeter should be used. (ii) State the reason why the clip-on (clamp) ammeter is not clamped around the flexible cord of the appliance. 22

Question 9 continued (c) State ONE reason why an ohmmeter is not used to carry out an insulation resistance test on a 230V final subcircuit. (d) A multi-function test instrument is being used to measure voltage and current values of a live 230V electrical appliance. State THREE precautions relating to the test instrument that will ensure personal safety. Note: 1. All the necessary safety equipment (overalls, rubber mats etc.) is available. 2. Set procedures are available. 3. All conductive items (e.g., rings) have been removed. (3 marks) (1) (2) (3) 23

Question 9 continued (e) You are using a voltmeter to measure the voltage on an electrical appliance. If the appliance switch was closed, what would be the main effect of connecting the voltmeter in series with the switch? 24

For Candidate s Use For Examiner s Use Only Questions Answered Marks 1 In the box, write the number of EXTRA sheets you have used. Write NIL if you have not used any 2 3 4 5 6 7 8 9 TOTAL 25