Ø 1000 * 588 mm 50 kg

Similar documents
Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Duct Cable GYTS-144B1.3

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

HELKAMA. Optical Fibre Cables

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Fiber Optic Distribution Cables (6-144 Fibers)

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

SPECIAL ELECTRICAL AND OPTICAL CABLES

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Fibre Optic Cable. Catalogue.

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Special Provision No. 683S28 December 2017

industry solutions: military

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Fibre Specification Standards

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

High Performance LSZH Fire Resistant Cable

DNVGL-CP-0402 Edition February 2016

Fibre optic media options and trends

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

Flame Retardant Overall Screened Instrumentation Cables (multicore)

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Catalogue Telecommunication Cables INTRODUCCIÓN

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Catalogue Power Cables

FIRE RESISTANT CABLES

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Main features of the JETnet system

Connectors for Optic Fibre Cable

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Fibre (TIA) Field Test Specification

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Tratos Railway Cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

fire resistant cables

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

WG Buried Fibre Cable Long Perimeter Detection System

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Installation Considerations for Pipelines

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

PRODUCT CATALOGUE Norröna

Caledonian Flame Retardant Coaxial Cables

Fiber Optic Patch Cord and Pigtails

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

ENHANCED FIRE PERFORMANCE CABLE

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

The Quality Connection. BETAflam Fire Resistant Safety Cables

Comtran Cable. Hub-LINK Cables for Transit Applications

CATEGORY 6A FTP RJ45 SOLUTION

Caledonian Fire resistant Coaxial Cables

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Introduction.

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Agencavi Srl has been specializing in the distribution of special cables and accessories for industrial automation since 1983.

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Telecommunication Cables

Detection of Solvents using a Distributed Fibre Optic Sensor

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

Dome Fiber Optic Closure SC-221

SECTION COMMUNICATIONS PATCH CORDS, STATION CORDS AND CROSS CONNECT WIRE

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

COMPACT FLAME CONTROLLER CFC 1000

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Firecel Safety Cables

THE TRUE FIRE SURVIVAL CABLE

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

INSTALLATION AND USER MANUAL

Fujikura-70S Single Fibre Fusion Splicer

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Cable technology for highest safety requirements

A measured step forward

Transcription:

GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 16 24 62.5/125-OM1 GUCN104 GUCN106 GUCN108 GUCN112 GUCN116 GUCN124 -OM2 BW /1200 GUCN204 GUCN206 GUCN208 GUCN212 GUCN216 GUCN224 -OM3 GUCN304 GUCN306 GUCN308 GUCN312 GUCN316 GUCN324 -OM2e GUCN404 GUCN406 GUCN408 GUCN412 GUCN416 GUCN424 -OM2 BW 500/500 GUCN504 GUCN506 GUCN508 GUCN512 GUCN516 GUCN524 -OM4 GUCN604 GUCN606 GUCN608 GUCN612 GUCN616 GUCN624 9/125 ITU G.655 GUCN704 GUCN706 GUCN708 GUCN712 GUCN716 GUCN724 9/125 ITU G.652D GUCN804 GUCN806 GUCN808 GUCN812 GUCN816 GUCN824 Std. plywood reel (non-returnable) Std. delivery length Ø 1000 * 588 mm 50 kg 2100 ± 100m Applications For outdoor and indoor use in structured (data) wiring systems such as (campus backbone). For outdoor and indoor use in networks for telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches. Suitable for direct burial. Features & Benefits A simple cable construction and consequently more cost-effective up to 24 fibres then multi-tube cables. High mechanical and full rodent protection provided by corrugated steel tape (CST) armour. Predicted lifetime > 30 years.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Primary coated optical fibres: Ø 250 ± 15 um. 2. Central tube, jelly filled (non-dripping and silicon-free) with up to 24 fibres. Individually colour coded optical fibres: 1 12: red natural yellow blue green violet brown black orange - turquoise pink and white. 13 24: red natural yellow blue green violet brown grey orange turquoise pink and white with rings. 3. Water swellable E-glass yarns as strength members and for the longitudinal watertightness. 4. Corrugated Steel Tape Armouring (CST): longitudinally applied steel tape (0.155 mm). 5. Black UV resistant FRNC/LSNH outer jacket. Identification: BELDEN OFC cable type number x fibre type + date-, meter- and P/N marking. Mechanical Data No. of fibres Max. 24 Ø Central tube (mm) 3.3 Ø nom./max. (mm) 9.0/9.3 Energy of flame (kj/m) 1045 Weight (kg/km) 103 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode- Field /Cladding Diameter (um) Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off 8 9/125 G.652D 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre- Type Mode-Field Diameter (um) Attenuati on average/ max. (db/km) Bandwidth (MHzkm) Ethernet Performance (m) 1 GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Transport/storage Installation Operation Pulling tension according to IEC 60794-1-2-E1 Long term Short term Bending radii for fibres and tubes Installation/operation Watertightness according to IEC 60794-1-2-F5 Crush resistance according to IEC 60794-1-2-E3 Armoured Central Loose Tube Cable Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6 Flame retardancy according to IEC 60332-3-22 (EN 50266-2-2) IEC 61034 (EN 50268-2) Circuit Integrity according to IEC 60331-25 (E120) EN 50200-30 to + 70 C -5 to + 50 C -30 to + 70 C 800 N 1 N >25 mm Yes 30 KN/m 10 x ø 20 x ø Halogen-free according to IEC 60754-2 (EN 50267-2-2) Corrosivity ph 3.5 - µs/cm 100 Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for outdoor use only. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. 02 Add Circuit Integrity 21/02/12 SN Date: 23/11/2010 Page 1 of 1 Part Number: Orig.: SN Review: GUCN 5