BS EN : 2001 & IEC :2000

Similar documents
NF X : Parts 1, 2, 3, 4 & 5

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS 476: Part 6: 1989+A1:2009

BS 476: Part 6: 1989+A1:2009

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO : 2010

BS EN ISO : 2010

BS EN ISO : 2010

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Review Fire Test Report

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

IMO Resolution MSC 61(67): Annex 1: Part 2

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 13 th October Test Sponsor: Tapco Europe Limited

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

The Fire Resistance Performance Of Timber Or Mineral Composite Based Insulated Doorsets When Fitted With D & E Architectural Hardware Spring Hinges

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

25 th November Title:

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

Fire Test Reports for Interpon D Powder Coatings

CERTIFICATE OF APPROVAL No CF 5236 EMVER PAINTS INDUSTRIES LLC

ASSESSMENT REVIEW. Review of Assessment Report WFRA C91415

Test Report: ICL/CR15/11/087

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

Test Report: ICL/H18/9039 Rev 1

Test Report No: ICL/H17/7967

CERTIFICATE OF APPROVAL No CF 5635 P3 SRL

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

CERTIFICATE OF APPROVAL No ME 5085

BCTC CARPET TECHNICAL CENTRE

Exova Warringtonfire - Expert Witness Directory 2018

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Report Number BTC 15450A

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

Classification of Fire Performance of Wall and Ceiling Lining Materials

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Abrasion Resistance of Fluoropolymer and polyester Coatings

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

Are Your Kitchen Hood Filters Compliant?

EU DECLARATION OF CONFORMITY (Doc) issued in accordance with the MARINE EQUIPMENT DIRECTIVE (MED) and EU/US MRA

GASTEC QA. Approval Requirements 136

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Fire resistance test on fire collars protecting a concrete slab penetrated by services

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

FTSG RESOLUTIONS. This document of FTSG resolutions was issued by the Company Secretary 20 July 2012.

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

Certificate No: EWS534

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

2 Examination of Cladding Panels (Laboratory)

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

Overhead Line Insulators

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

ISO INTERNATIONAL STANDARD

TEMPORARY IMMERSION AND DUST TEST REPORT

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

Glass fibre rovings - Non-metallic materials

Functional Safety: the Next Edition of IEC 61511

Centrum stavebního inženýrství a.s.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ENHANCED FIRE PERFORMANCE CABLE

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

CERTIFICATE OF APPROVAL No CF 136

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

INTERNATIONAL STANDARD

Transcription:

Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 60695-2-11: 2001 & IEC 60695-2-11:2000 Glow-wire flammability test for end-products A Report To: Document Reference: 308706 Date: 2 nd September 2011 Page 1 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429 This report in issued in accordance with our terms and conditions, a copy of which is available on request.

Executive Summary Objective To determine the glow wire flammability performance of the following product when tested in accordance with BS EN 60695-2-11:2001 & IEC 60695-2-11:2000 Generic Description Product reference Thickness Density Fibre glass reinforced polycarbonate heavy duty connector Heavy Duty Connector 31.91mm* 1.33g/cm³ Individual components used to manufacture composite: Polycarbonate PC Not stated Not stated Glass fibre GF20 Not stated Not stated *Determined by Exova Warringtonfire Please see page 6 of this test report for the full description of the product tested Test Sponsor Test Results:, 759-3 Chengbei Industrial Zone, Chaoyuan Road, Tongan District, Xiamen, China The following results were recorded when the results were assessed against the requirements detailed in NF F 16-101 and STM-S-001: Ignition did occur at a temperature of 850 C. Ignition did not persist at 850 C. Date of Test 14 th July 2011 Signatories Responsible Officer T. Mort * Senior Technical Officer Authorised S. Deeming * Senior Technical Officer * For and on behalf of Exova Warringtonfire. Report Issued: 2 nd September 2011 This version of the report has been produced from a.pdf format electronic file that has been provided by Exova Warringtonfire to the sponsor of the report and must only be reproduced in full. Extracts or abridgements of reports must not be published without permission of Exova Warringtonfire Document No.: 308706 Page No.: 2 of 9

CONTENTS PAGE NO. EXECUTIVE SUMMARY... 2 SIGNATORIES... 2 TEST DETAILS... 4 DESCRIPTION OF TEST SPECIMENS... 6 TEST RESULTS... 7 REVISION HISTORY... 9 Document No.: 308706 Page No.: 3 of 9

Test Details Purpose of test Scope of test To determine the performance of a material when it is subjected to the conditions of the test specified in BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000, Fire Hazard Testing Part 2-11: Glowing / Hot-Wire Based Test Methods Glow-Wire Flammability Test Methods For End-Products utilising the test procedure specified in Clause 8 of BS EN 60695-2-10: 2001 and Clause 10 of BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000. BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000 specifies the details of a glow wire test when applied to end products for fire hazard testing. For the purpose of this standard, end product means electro technical equipment its sub-assemblies and components. If possible, the specimen should be a complete end-product. If the test cannot be made on the complete end-product, it is acceptable to: A) Cut a piece containing the part under examination from it, or B) Cut an aperture in the complete end-product to allow access of the glowwire, or C) Remove the part under examination in its entirety and test it separately. The test is carried out to ensure that under defined conditions, the glow-wire does not cause ignition of parts, and that a part, if ignited, has a limited duration of burning without spreading fire by flames or by burning or glowing particles falling from the test specimen. If the test specimen emits flames during the application of the glow-wire, the fire hazard created my necessitate further tests using other ignition sources such as the needle-flame applied to those parts which are reached by the emitted flames. This test shall not be used for small parts for which reference may need to be made to other test methods, for example, the needle flame test in IEC 60695-2- 2. Fire test study group/egolf Instruction to test Certain aspects of some fire test specifications are open to different interpretations. The Fire Test Study Group and EGOLF have identified a number of such areas and has agreed Resolutions which define common agreement of interpretations between fire test laboratories which are members of the Groups. Where such Resolutions are applicable to this test they have been followed. The test was conducted on the 14 th July 2011 at the request of Xiamen Wain Electrical, the sponsor of the test. Document No.: 308706 Page No.: 4 of 9

Provision of test specimens The specimens were supplied by the sponsor of the test. Exova Warringtonfire was not involved in any selection or sampling procedure. Conditioning specimens Face to test of The specimens were received on the 20 th June 2011. Prior to the test, the specimens were conditioned for a minimum period of 24 hours in an atmosphere having a temperature between 15 C and 35 C and a relative humidity of between 45% and 75%. The glow wire was applied to 3 different points of the specimen (see below). Positions of glow wire application points Document No.: 308706 Page No.: 5 of 9

Description of Test Specimens The description of the specimens given below has been prepared from information provided by the sponsor of the test. All values quoted are nominal, unless tolerances are given. General description Fibre glass reinforced polycarbonate heavy duty connectors Product reference Heavy Duty Connector Name of manufacturer Colour reference Grey Overall size 65mm x 44.4mm x 31.91mm (determined by Exova Warringtonfire) Overall weight of connector 42.46g (determined by Exova Warringtonfire) Overall density 1.36g/cm 3 (stated by sponsor) 1.33g/cm 3 (determined by Exova Warringtonfire) Generic type Polycarbonate Product reference PC Name of manufacturer See Note 1 below Polycarbonate Trade name of flame retardant Non-Halogen Flame Retardant Generic type of flame Non-halogen flame retardant retardant See Note 1 below Amount of flame retardant 0.5 to 5% Type Fibrous glass Glass fibre Product reference CAS Number - 65997-17-3 Name of manufacturer See Note 1 below Resin to glass ratio (by weight) Percentage glass reinforcement (by weight) 20% Brief description of manufacturing process Design mould Injection moulding Deburring Semi-finished products (PC body) Note 1. The sponsor of the test was unable to provide this, or further information, as their supplier is unwilling to provide this information. Document No.: 308706 Page No.: 6 of 9

Test Results The test results relate only to the behaviour of the specimens of the product under the particular conditions of test; they are not intended to the sole criterion for assessing the potential smoke hazard of the product in use. The test results relate only to the specimens of the product in the form in which they were tested. Small differences in the composition or thickness of the product may significantly affect the performance during the test and may therefore invalidate the test results. Care should be taken to ensure that any product which is supplied or used is fully represented by the specimens which were tested. The test was performed in accordance with the requirements of BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000, Fire Hazard Testing Part 2-11: Glowing / Hot-Wire Based Test Methods Glow-Wire Flammability Test Methods For End-Products utilising the test procedures specified in Clause 8 of BS EN 60695-2-10: 2001 and Clause 10 of BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000 and this report should be read in conjunction with those Standards. In accordance with the standard, wrapping tissue was placed 200mm below the point of glow-wire application. A total of three specimens was tested at 850 C and the following observations were recorded: Where: t i = The duration from the beginning of tip application up to the time at which the specimen or the layer placed below it ignites. t e = The duration from the beginning of tip application up to the time when flames extinguish during or after the period of application. t a = The duration of tip application Temperature 850ºC 850ºC 850ºC Duration of Glow Wire Application t a (secs) 30 30 30 Time to Ignition - t i (secs) N/A 26 17 Time to Extinguishment - t e (secs) N/A 31 30 Duration of flaming after removal of the Glow- Wire (secs) N/A 1 0 Duration of flaming (t e t i ) (secs) N/A 5 13 Max Height of Flaming (mm) N/A 5 10 Ignition of Tissue Paper No No No Document No.: 308706 Page No.: 7 of 9

Evaluation of Test Results BS EN 60695-2-11: 2001 / IEC 60695-2 11: 2000 specifies that, unless otherwise specified in any relevant technical specification, the specimen is considered to have satisfactorily withstood the glow-wire test if one of the following two situations applies: A) if flames or glowing of the test specimen extinguish within 30 s after removal of the glow wire, i.e. t e t a + 30s; and B) when the specified layer of wrapping tissue is used there shall be no ignition of the wrapping tissue. In this case the sponsor stated that the test was being performed to determine the performance of the product against the technical specifications referenced NFF 16-101 and STM-S-001. When the results obtained during this investigation are assessed against the aforementioned specifications, the following conclusions can be made: Ignition did occur at a temperature of 850 C. Flame did not persist following removal of glow-wire at a temperature of 850 C. Validity The specification and interpretation of fire test methods are the subject of ongoing development and refinement. Changes in associated legislation may also occur. For these reasons it is recommended that the relevance of test reports over five years old should be considered by the user. The laboratory that issued the report will be able to offer, on behalf of the legal owner, a review of the procedures adopted for a particular test to ensure that they are consistent with current practices, and if required may endorse the test report. This report may only be reproduced in full. Extracts or abridgements shall not be published without permission of Exova Warringtonfire. Document No.: 308706 Page No.: 8 of 9

Revision History Issue No : Revised By: Reason for Revision: Issue Date: Approved By: Issue No : Revised By: Reason for Revision: Issue Date: Approved By: Document No.: 308706 Page No.: 9 of 9