Architecting a Distributed FactoryTalk View SE Application

Similar documents
Technical Publications. FactoryTalk Alarms and Events System Configuration Guide

FactoryTalk Alarms and Events. System Configuration Guide

INTEGRATED PRODUCTION & PERFORMANCE SUITE. Alarms and Events SYSTEM CONFIGURATION GUIDE

VTScadaLIGHT for Small Water & Wastewater Systems

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

PcVue Solutions. PcVue Solutions

Compact Product Suite Compact HMI 6.0 Overview ABB

T32 - FactoryTalk Network Manager Software

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

BMS Specification. Lonix Ltd.

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

Introduction. Introduction

Patriot Systems Limited

Platform Services BACnet Alarm Management

Experion LX Direct Station Specification

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Insert Photo Here Bos Howard Johns Manville

Patriot Systems Limited

GMS GRAPHICAL MANAGEMENT SYSTEM

Pro-Watch Facility Manager

Process Control Systems Engineering

Station Planning Guide

For Complete Fire and Gas Solutions

Using ANM Mobile CHAPTER

Process Measurement & Control. Experion HS. A New Level in Operational Excellence

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Ademco Vista Alarm Panel

Reference Manual. Common Alarm Block (P_Alarm) Version 3.1

Protect your investment with Safety Manager

GasGard 100 Control System

Network Hardware and wiring (quiz)...

Complexity made simple

Before you install ProSeries Express Edition software for network use

L automazione al servizio della manutenzione

Dynamic Solutions. Endless Possibilities. Steve Padasack, Finch Paper LLC Rick Van Fleet, Honeywell

P2000 and Metasys System Integration

Imtech Marine Free Technics. Type-approved, user-centered yacht automation

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

IntesisBox BACnet/IP Server - Notifier ID3000 series

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

ASCO PowerQuest Power Monitoring and Control Systems

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION

Fike Safety y Technology Ltd

Samsung SDS BMS Ver.2.0. Technical Specification

Architectural and Engineering Specification for a Security Management System. StarNet 2

D-Link Central Management System

Smart Wireless Sensor

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

Avigilon Control Center 5 System Integration Guide

Yokogawa DX Ethernet Driver Help Kepware Technologies

ThermoControl 0 C - 10 C - 20 C - 30 C

Planning Checklist for new IGSS projects

2013 Honeywell Users Group Americas. Joe Bastone. Experion PKS Slick Tricks

Daily Offsite; 30 days of backup available; Offsite Annual backup maintained for 5 years

UD-VMS510i. Surveillance Management Center

Niagara4 Technical Certification Program Student Guide DAY 1 DAY 2

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Product Brief for Alarm Analytics V9.3 October 2013

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Fully redundant and customizable alarm, monitoring & Control system

Home center Interface Server. Technical sheet

DeltaV Connect Solution for Honeywell Systems

VAC PLC. System Description

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Safety Instrumented Fire & Gas Systems

System Description AutroMaster V Presentation System

Facility Commander Wnx

Alarm Coordination Connected Components Building Block. Quick Start

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Unitronics Demo Case Guide

Smart Wireless Sensor

MobiCall-Client PC Safety at work

AC2000 Security Hub Security and Event Management System

C&I SYSTEM DIAGNOSTICS WITH SELF MONITORING AND REPORTING TECHNOLOGY (SMART)

Desigo CC Building Automation and Fire Safety FAQs

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

USER S GUIDE. AXIS Cross Line Detection

IndigoVision Alarm Panel. User Guide

Thailand Technology Summit 2016

BIS - Overview and basic package

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

Yokogawa DX Ethernet Driver PTC Inc. All Rights Reserved.

Benefits of Having a VNC Server in a Car Head-Unit

Integrated security management platform for Windows. Seamless. Effective. Efficient.

MultiSite Manager. Setup Guide

Compact HMI Overview

DEVELOPMENT OF THE TANGO ALARM SYSTEM

Introduction to Modular Programming. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Security Escort Central Console Software SE2000 Series

WorkstationST* Alarm Viewer

Avigilon Control Center System Integration Guide

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

TPS Virtualization and Future Virtual Developments Paul Hodge, Honeywell

Transcription:

Architecting a Distributed FactoryTalk View SE Application October 5 th, 2017 Kendall Connection Live PUBLIC PUBLIC - 5058-CO900H Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

Agenda Introduction System Overview Architecting Exercise Supporting Hardware & Software Labs PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

Serving Customers For 110+YRS 50,000+ FACTORYTALK VIEW SE SYSTEMS OVER 1Million PANELVIEW TERMINALS SOLD 80+ COUNTRIES LOCALIZED LANGUAGE SUPPORT Award Winning Product Official HMI of Control Engineering Engineers Choice Award Winner Control Design Readers Choice Award 24/7/365 worldwide support 8,000+ System Integrators @ROKAutomation #HMI #SCADA #ModernHMI Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 3

Introduction Architecting a Distributed FactoryTalk View SE Application @ROKAutomation #HMI #SCADA #ModernHMI Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

Operations Engineering Maintenance Plant IT FactoryTalk View Building a better View PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

What is SE? FactoryTalk View Site Edition (SE) meeting the demands of multiple stakeholders including engineering, maintenance, operations, and production Information Technology (IT). PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 6

FactoryTalk View Site Edition Station Distributed FactoryTalk Directory FactoryTalk View SE FactoryTalk Alarms and Events RSLinx Enterprise FactoryTalk View Studio provides a common development tool for Station and Distributed Applications Scalable from a single station to a centralized distributed architecture PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 7

Machine Edition (ME) vs. Site Edition (SE)? What s the difference???? PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 8

ME vs SE Feature RSView32 FactoryTalk View SE Distributed FactoryTalk View SE Station FactoryTalk View ME Latest Technology X X X Operating Systems Vista/2008/2003 Vista/2008/2003 Vista/2008/2003 Vista/2008/2003/XP /XP/2000 /XP/2000 /XP/2000 /2000/CE 1 Embedded Platforms PanelView Plus VersaView CE Windows Domain Security X X X X ActiveX X X X Platform considerations PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 9

ME vs SE Feature RSView32 FactoryTalk View SE Distributed FactoryTalk View SE Station OPC Client/ Client Client FactoryTalk -side VBA Only X Network Scope (Directory) Local Scope (Directory) Client-side VBA X X Network Requirement IIS FactoryTalk View ME Client For PanelView Plus see 39444 - PanelView Plus and remote OPC server Local Scope (Directory) PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 10

ME vs SE Feature RSView32 FactoryTalk View FactoryTalk View SE Distributed SE Station Supervisory level: Supervisory level: Primary application single-station or single-station or Supervisory level: single-server, single-server, single-station multiple-client multiple-client Tag-based HMI X X X X FactoryTalk View ME Machine level: single-station Direct referencing X X X Max number of servers / clients Web clients 1 / 20 10 / 50 X FactoryTalk Viewpoint FactoryTalk Viewpoint FactoryTalk Viewpoint (5.10) PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 11

ME vs SE Feature Thin clients (Terminal Services) Multi-user development Remote configuration at runtime Redundancy - Data Redundancy - HMI RSView32 X Through 3rd-party RDP software X ADS FactoryTalk View SE Distributed X X X X X FactoryTalk View SE Station Through 3rd-party RDP software FactoryTalk View ME VNC server or Terminal Client Through 3rd-party RDP software PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 12

ME vs SE Feature Animation (Visibility, color, fill, horizontal and vertical position, width, height, rotation, horizontal and vertical slider, ) Alarming RSView32 FactoryTalk View SE Distributed FactoryTalk View SE Station FactoryTalk View ME and touch and touch and touch no touch Tag-based: digital & analog; definable alarm severities, alarm log Tag-based: digital & analog; definable alarm severities, alarm log. As of v5.0, FactoryTalk Alarms and Events are also available Tag-based: digital & analog; definable alarm severities, alarm log State-based (from controller); alarm log PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 13

ME vs SE FactoryTalk View FactoryTalk View FactoryTalk Feature RSView32 SE Distributed SE Station View ME 20+ data log 20+ data log models; 20+ data log models; 1 data log model; up models; each with each with up to each with up to to 100 tags; 300,000 Data Logging up to 10,000 tags; 10,000 tags; log to 10,000 tags; log to records max; export log to ODBC or ODBC or proprietary ODBC or dbf db to dbf proprietary db db Trending TrendX & native TrendX TrendX TrendX (subset) Security Security assigned to tags, graphic displays, macros, commands, OLE objects; local or Windows security Security assigned to tags, graphic displays, macros, commands, OLE objects; Windows security Security assigned to tags, graphic displays, macros, commands, OLE objects; Windows security Display-based; local or Windows security PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 14

ME vs SE Feature Runtime Language Switching Development Environment Additional Features RSView32 Available in version 7.30 or greater (available through VBA in older versions) RSView32 Works Test run; macros; parameter passing; derived tags; event detector FactoryTalk View SE Distributed FactoryTalk View SE Station FactoryTalk View ME X X X FactoryTalk View Studio Test run; macros; parameter passing; derived tags; event detector FactoryTalk View Studio Test run; macros; parameter passing; derived tags; event detector FactoryTalk View Studio Test run; macros; parameter passing PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 15

ME vs SE Feature Communications Pricing model RSView32 RSLinx Classic, KEP Enterprise, RSLinx Enterprise (must have RSOPC Gateway) Tag-based pricing; multiple levels FactoryTalk View SE Distributed RSLinx Classic; RSLinx Enterprise; KEP Enterprise Display-based pricing; multiple levels FactoryTalk View SE Station RSLinx Classic; RSLinx Enterprise; KEP Enterprise Display-based pricing; multiple levels FactoryTalk View ME RSLinx Classic (desktop only); RSLinx Enterprise (including Remote I/O); KEP Enterprise Display-based pricing; multiple levels for Desktop OS Included with PanelView Plus, VersaView CE PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 16

ME vs SE Feature Remote Messaging RSView32 Messenger FactoryTalk View SE Distributed FactoryTalk View SE Station FactoryTalk View ME Recipe RecipePro & Native Native Native RecipePlus SPC SPC RSLadder 5 / 500 X X X X Extensions X PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 17

A View for Every Manufacturing Scenario FactoryTalk View Machine Edition Panel HMI FactoryTalk View Site Edition Scalable PC Based HMI PanelView Plus and Compact Industrial and Non-Industrial Computers and Monitors FactoryTalk ViewPoint Web-Based HMI PUBLIC Copyright 2016 Rockwell Automation, Inc. All Rights Reserved. 18

Before We Begin Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 19

System Overview Architecting a Distributed FactoryTalk View SE Application Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 22

FactoryTalk View SE Components DHCP SE Client HMI Data DNS AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 24

FactoryTalk View SE Components DHCP DNS AD FactoryTalk Directory High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 25

FACTORYTALK DIRECTORY Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 26

Joining a FactoryTalk Directory Local Directory Network Directory Local Directory Network Directory Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 27

FactoryTalk Services Platform Common software license management for all FactoryTalk products Common address lookup of resources that are shared among FactoryTalk enabled products Common security authority for all FactoryTalk components in the system Common diagnostic messaging subsystem across all FactoryTalk products Activation Directory Security Diagnostics Comprehensive record of any changes made to the manufacturing system Audit Enterprise-wide access to real-time manufacturing data Live Data Enterprise-wide notification to real-time alarms and events that require action Alarms and Events Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 28

FactoryTalk View SE Components DHCP SE Client HMI Data DNS AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) No Activation One Directory for the entire application Directory is cached at every component OS High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 29

FactoryTalk Directory Installation Standalone FactoryTalk Directory Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 31

FactoryTalk Directory Internet Firewall Domain Controllers W2K8 O/S DNS/DHCP/WINS Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 32

CLIENTS Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 33

Thick Client Distributed System Traditional installation strategy Local installations and licensing of all products Each computer has full operating system install FactoryTalk Directory View Site Edition s Clients RSLinx s Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 34

Thin Client Distributed System Traditional or virtualized installation strategy Remote Desktop added with View Site Edition Client Installation Desktop computers can be replaced with thin client computers FactoryTalk Directory View Site Edition s Clients RSLinx s RDS with Client Install Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 35

Web Client or ViewPoint Clients Web client can be on any supported device FactoryTalk ViewPoint is an extension of View SE Clients FactoryTalk Directory View Site Edition s RSLinx s FactoryTalk ViewPoint Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 36

When to use a web client? Use FactoryTalk View Site Edition Client (thick or thin client) for: For onsite operators High availability and performance Rich application scope VBA custom code Use of ActiveX controls Full Trending capability Full Alarming capability Use FactoryTalk ViewPoint Client (web client) for: Casual operators, managers, mobile users Non-critical performance Limited application scope Graphics displays Browser navigation Remote monitoring of trends and alarms Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 37

FactoryTalk View SE Components Activation Required 50 SE Clients * And 50 ViewPoint Web Clients ** Workstation OS DHCP SE Client HMI Data DNS AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 38

FactoryTalk View SE Client Installation Site Edition Client Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 39

HMI Clients Internet Domain Controllers W2K8 O/S DNS/DHCP/WINS Firewall Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 40

HMI SERVERS Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 41

HMI Graphic Displays Displays Objects Global Objects Parameter Files HMI Tags Alarms Legacy Data Logs Event Detectors Derived Tag Files Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 42

FactoryTalk View SE Components SE Client Activation Required Up to 10 s High Availability OS HMI Data DNS DHCP AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 43

When to Use Multiple HMI s Load balancing Large number of displays for single application. Large number of clients for single application. Logical or Physical areas Ability to take down one HMI server for maintenance without affecting entire system. Expansion Grow an application by adding a new line, duplicating existing HMI server. Security Creating multiple servers allows security configuration at an area level. Note: In production The maximum number of FactoryTalk View SE HMI servers that can be hosted on a single computer is 1. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 44

HMI Installation Site Edition Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 46

HMI s Internet Firewall Domain Controllers W2K8 O/S DNS/DHCP/WINS SE (1) HMI Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 47

DATA SERVERS Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 48

FactoryTalk Data Options **Preferred** Live Data for FactoryTalk View SE and other FactoryTalk applications (FactoryTalk Transaction Manager, FactoryTalk Historian, etc.) Optimized performance via TCP/IP, not DCOM Offline browsing of Logix based controller projects Preferred Data for ALL Rockwell Automation controllers Alias Topic Functionality Complex communication routing. Protocol changing (ex. Ethernet to DH+ ) Offline browsing of PLC/SLC RSLogix files Kepserver Enterprise and 3 rd Party OPC s Kepserver Enterprise is preferred for connecting to Non-AB controllers. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 49

Data s - Complex Paths Data EtherNet/IP ControlLogix ControlLogix DH+ ControlNet PLC SLC PLC SLC ControlLogix RSLinx Classic Required DH+ protocol = PCCC Ethernet protocol = CIP RSLinx Enterprise Supported ControlNet protocol = CIP Ethernet protocol = CIP Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 50

FactoryTalk View SE Components SE Client HMI No Activation** Up to 10 s High Availability OS Data DNS DHCP AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 51

RSLinx Enterprise Data FactoryTalk Live Data clients (FactoryTalk View, FactoryTalk Historian, FactoryTalk VantagePoint, FactoryTalk Transaction Manager) Data Network Data Network FactoryTalk Live Data servers (RSLinx Enterprise) Control Networks FactoryTalk Live Data servers (RSLinx Enterprise) Control Networks ControlLogix CompactLogix PLC-5 SLC 500 ControlLogix CompactLogix PLC-5 SLC 500 Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 52

RSLinx Enterprise Sizing Considerations Digital and Analog Instruction based Alarms Tag Types (Scalar, Array, UDT) Number of Controllers (Shortcuts) RSLinx Enterprise Resource Impact Tags defined within each controller (Namespace) FactoryTalk Live Data Clients Recommended Data s 3 2 1 10 Clients & 10 Controllers Example Configurations 20 Clients & 20 Controllers 30 Clients & 30 Controllers Assumes: 10K Numeric Tags / Ctrl and 1K Strings Tags / Controller; Each client requests 2K Numeric tags, 200 Stings, 500 Digital and 500 Analog Alarms. Number of Tags on Scan Number of Tag References by Clients Distribute the load across multiple RSLinx Enterprise Data s. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 53

Data s Internet Firewall Domain Controllers W2K8 O/S DNS/DHCP/WINS SE (1) HMI Data (1) RSLinx Enterprise Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 54

ALARM SERVERS Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 55

Alarming HMI/Legacy Alarms Alarm configuration and status are located in the HMI server. Uses legacy alarm objects (Banner, Summary.) A single update rate for all HMI alarms. Tag-Based Alarms Alarm configuration and status are located in the FactoryTalk Alarm server. Uses new alarm objects (Banner, Summary, etc.) Can use RSLinx Enterprise, Classic, or 3rd party OPC Preferred alarming method for legacy and 3rd party devices Logix Alarm Instructions Alarm configuration and status are located in the Logix 5000 device. Uses new alarm objects (Banner, Summary, etc.) Utilizes RSLinx Enterprise for alarm communications Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 56

FactoryTalk Alarms & Events Two Alarm Sources Alarm instructions available in the Logix family of controllers. The controller detects alarm conditions and triggers alarm events. The FactoryTalk Alarms and Events service captures all of the controller events and sends notification to connected clients. Information is displayed in the A&E Alarm Management components on the clients Logix Alarm Instructions Software-based alarm servers poll data tags for alarm conditions. The Alarm server detects alarm conditions and triggers alarm events The FactoryTalk Alarms and Events service captures all of the controller events and sends notification to connected clients Information is displayed in the A&E Alarm Management components on the clients Supports all controllers - PLC-5, SLC 500, or any third-party device through OPC-DA Tag-Based Alarms Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 57

Logix Alarm Instructions Reduction in network traffic through publishing technology Improved time stamp accuracy No alarm information loss in the event of HMI outage No HMI tag duplication required, alarm instruction or tags directly A single, consistent shared alarm generation and response mechanism On the fly changes to alarming tags are automatically updated in HMI Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 58

Logix Alarm Instructions with v20 Controllers with revision 20 or earlier - System performance and tested limits Specification Controller specifications Value Tested number of subscribers (RSLinx Enterprise s) per controller 3 Controller memory used for buffering by each subscriber 100k Typical number of alarm state transitions per subscriber 1000 Recommended maximum number of alarms per controller 2000 Approximate controller memory used for each alarm Supported languages for alarm messages 1k (digital), 2.2k (analog)* All languages supported by FactoryTalk View SE Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 59

Logix Alarm Instructions with v24 Controllers with revision 24 - System performance and tested limits Specification Controller specifications Value Tested number of subscribers (RSLinx Enterprise s) per controller 3 Typical number of alarm state transitions per subscriber 1000 Recommended maximum number of alarms per controller 3000 Approximate controller memory used for each alarm Supported languages for alarm messages 1k (digital), 2.5k (analog)* All languages supported by FactoryTalk View SE Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 60

FactoryTalk View SE Components SE Client HMI Data DNS DHCP AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) No Activation Up to 10 s High Availability OS Max 10,000 alarms per server (100,000 total) High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 61

Alarms and Events Installation Standalone RSLinx Enterprise Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 62

Installation Details Standalone RSLinx Enterprise components installed by default; FactoryTalk Service Platform FactoryTalk Activation Manager FactoryTalk Alarms and Events RSLinx Enterprise RSLinx Classic Required Optional; Included by default Optional; Not included by default Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 63

Alarm s Internet Firewall Domain Controllers W2K8 O/S DNS/DHCP/WINS SE (1) HMI Data (1) RSLinx Enterprise Alarm (1) A&E Tag-based Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 64

FactoryTalk View Studio ENTERPRISE Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 65

FactoryTalk View SE Components DHCP SE Client HMI Data DNS AD Studio Enterprise Alarm FactoryTalk Directory ViewPoint (Optional) Activation Required Multi-user development Up to 5 simultaneous development stations Workstation OS High Availability Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 66

Studio Enterprise Installation Studio Enterprise Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 67

View Studio Enterprise Internet Firewall Domain Controllers W2K8 O/S DNS/DHCP/WINS Application (1) HMI (1) Data s RSLinx Enterprise w/alarms and Events (1) Tag-based Alarm Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Engineering Workstation RSLogix 5/500/5000 RSLinx Classic View Studio Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 68

Sample Redundant System Internet Firewall Domain Controllers For the Cel Sys Domain W2K8 O/S DNS/DHCP/WINS Primary (1) HMI (1) Data s RSLinx Enterprise w/alarms and Events (1) Tag-based Alarm Redundant Pair Secondary (1) HMI (1) Data s RSLinx Enterprise w/alarms and Events (1) Tag-based Alarm Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications FactoryTalk Directory FTD FactoryTalk Activation 5 Clients FactoryTalk View SE Clients Managed Ethernet Switch for Control System Network (CSN) HMI/Ctrl Communications ControlLogix ControlLogix ControlLogix ControlLogix PLC-5 PLC-5 SLC SLC Flex Flex Engineering Workstation RSLogix 5/500/5000 RSLinx Classic View Studio Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 69

High Availability Considerations Only one host should be designated as the Primary with the responsibility of the Primary HMI and Primary Data servers. Redundancy is not a mechanism for load balancing. Good Bad #1 #2 #1 #2 HMI Primary HMI Secondary HMI Primary HMI Secondary Data Primary Data Secondary Data Secondary Data Primary Redundant Pair Redundant Pair Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 70

Architecting Exercise Architecting a Distributed FactoryTalk View SE Application Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 71

Design a Distributed Application Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 72

Design a FactoryTalk View SE System Design a FactoryTalk View SE Network Distributed application for a customer with the following criteria. The plant is divided into 2 areas. The first consists of Small Production Line 1 and Production Line 2. This area of the plant runs from 8 AM to 5 PM and power is turned off outside these hours to conserve energy. There is a need for 140 screens and about 5000 alarms. Customer is requesting redundancy for their alarms only in this area. The second is made up of Production Line 3. This area runs 24/7. In this area, there is a need for 240 screens and 10,000 alarms. Customer is requesting full redundancy (HMI, Alarms, and Data s) for this area. There is a need for 1 Engineering Workstation, 10 Read/Write thick clients The customer has provided 5 servers, 1 Engineering Workstation and 10 operator workstations. Some displays have to be made available to the plant manager laptop without installing any Rockwell Software on it. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 73

Design Exercise Engineering Workstation Control Room with 10 Clients View Studio Enterprise RSLogix 5000 / Studio 5000 RSLogix 5 RSLinx 10 View SE Clients Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 74

Design Exercise (Solution 1: Preferred) FTD Located in Area2 that runs 24x7 ViewPoint Area2 Primary HMI (250) Alarm Data Area2 Secondary HMI (250) Alarm Data Area1 Primary HMI (250) Alarm Data Area1 Secondary Alarm Data Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 75

Design Exercise (Solution 2) FTD Located in Area2 that runs 24x7 ViewPoint Area 2 Primary HMI (Unlimited) Alarm Data Area 2 Secondary HMI (Unlimited) Alarm Data Area 1 Primary Alarm Data Area 1 Secondary Alarm Data Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 76

Design Exercise (Solution 3) FTD Located in Area2 that runs 24x7 ViewPoint Area2 Primary HMI (Unlimited) Alarm Data Area2 Secondary HMI (Unlimited) Alarm Data Area1 Primary HMI (Unlimited) Alarm Data Area1 Secondary Alarm Data Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 77

Where to find additional information Visit the Rockwell Software web site (FactoryTalk View SE in this case) http://www.rockwellautomation.com/rockwellsoftware/products/factorytalk -view-se.page? Product Demo / Videos Customer Stories Product Profiles User Guides Ordering Information System Requirements Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 78

Supporting Hardware & Software Architecting a Distributed FactoryTalk View SE Application Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 79

Related Products Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 80

Stratus Fault-Tolerant s Fully redundant hardware Plug-and-play Operational simplicity No failover time No data loss Hot-swappable components Single System - Single License 24/7/365 support service Typical configurations cost $18,000 to $60,000 Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 81

VersaView 5000 VersaView 5100 Monitors VersaView 5200 Thin Clients Integrated display panel thin clients and non-display thin clients VersaView 5400 PCs Integrated display panel PCs and non-display PCs Innovative open architecture and modern design! Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 82

ThinManager Securely Delivers Content ASSIGN AND DELIVER CONTENT IN THREE WAYS Devices Thin/Zero Clients Mobile Devices PCs Windows Based VNC Content Types HMI MES CMMS ERP Web Content IP/USB Cameras Terminal Shadow PanelView Plus The Connected Enterprise securely manages application delivery to devices, users and locations. Users Individuals User Groups Locations Facility Lines/Areas Assets/Devices Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 83

Manage Every Device, User & Location Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 84

Faceplate/Add-on Instruction Sets Preconfigured View ME/SE Status, Control, and Diagnostic Displays Logix I/O Control Devices Networks Application Faceplates Providing Premier Integration with Rockwell Automation Architecture & Devices Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 85

PlantPAx Library of Process Objects The PlantPAx Library of Process Objects is a predefined library of controller code (AOIs), display elements (global objects), and faceplates All together, they allow you to quickly assemble large applications with proven strategies, rich functionality, and known performance Find more information on Rockwell Automation Knowledgebase - Answer ID 62628 Step 1: Add and configure Add On Instruction (AOI) in control program Step 2: Drop Pre-defined Global Object onto display and assign to an AOI instance Step 3: Access faceplate from Global Object at runtime for control and maintenance operations. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 86

PLANT-WIDE Control and Optimization SCALABLE and Modular SECURE Open and Information-enabled FLEXIBLE Delivery and Support Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 87 87

DCS functionality PlantPAx System capabilities Characterized Control and I/O Process Safety Engineering & Configuration Asset Management Process Optimization Batch Management Secured Environments Operations Productivity Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 88

Virtual Image Templates Batch Management Asset Management Engineering Workstation Operator Workstation Process Automation System s Information Information Information REDUCE engineering time and validation costs EXTEND system lifecycle ENHANCED availability options through virtualization EASE lifecycle management Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 89

Thank you Architecting a Distributed FactoryTalk View SE Application Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 90