Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

Similar documents
SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

PAC International, Inc. RSIC-1 FS System 37" and Larger (200 lb max)

Sizes. Colors. Features

Crown Boiler Company

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

Knauf Direct Bonding and Metal Furring

Technical Manual for the Alarm Pull Station PH1

ALUMINUM. ELEVATED. CEDAR RENDITIONS DESIGN SERIES INSTALLATION INSTRUCTIONS

Furring Channel Resilient Mount - Direct Fixing. Ceiling Systems. intex.com.au / intex.co.nz. Intex

Submersible Supply Pump Packages

Soft Sheer Vertical. Installation and Care Guide

OPERATION MANUAL.

SMART DUCT SYSTEM. Caution: Do not tamper with the unit or its controls. Call a qualified service technician.

INSTALLATION INSTRUCTIONS

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

CODE SUMMARY REQUIREMENTS (NEW CONSTRUCTION/TENANT IMPROVEMENT (TI))

EasyWire Between Joists Installation Instructions

RIGHT-SIZED SYSTEM SMART DUCT SYSTEM

TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1" Thick Direct-Attach Wall and Ceiling Panels

AuthenticDECORATIVE METAL WALLS & CEILINGS

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz SERIES RV ROOF TOP AIR CONDITIONER/HEAT PUMP

HVAC Equipment Access Equipment Location

Fire Protection Systems FST 209. COURSE SYLLABUS Fire Protection Systems FST 209 [Semester] CRN 3 Credits

Tectum Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1-Inch Thick Direct-Attach Wall and Ceiling Panels

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

CUSTOM DRAPERY + CUSTOM WINDOW HARDWARE PROGRAMS

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

Smoke extraction duct of sheet steel

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

Heater Core Replacement

Emergency Response Plan

BUILDER S PRE-INSPECTION CHECKLIST

Concealed Ceiling Systems

A NEW WAVE OF IN-CEILING SPEAKERS

FLUSH MOUNT INSTALLATION MANUAL

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

Preventative Maintenance Tables

BUILDER S PRE-INSPECTION CHECKLIST

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

ESF 15: EMERGENCY PUBLIC INFORMATION

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

CEILING FAN OWNER S MANUAL

IdealFILM. Do-It-Yourself Installation Manual

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

INSTALLATIONGUIDE. HotSeam TM Overview ICE ROOF

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Non-RTD Hot Melt Hose Replacement

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Roof Mounting System. Installation Manual. Standard (XRS) and Light (XRL) Rails with Integrated Grounding *ETL Listed Per UL Edition v1.

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

RESPIRABLE CRYSTALLINE SILICA PARAGRAPHS (C) THROUGH (J)

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

Half Inch Round LED Rope Light

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

Developing a Healthcare Facility Fire Door Inspection Program

MAKAI WIDESPREAD FAUCET INSTALLATION

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

INSTALLATION AND SERVICE MANUAL REMOTE TYPE DISPLAY CASE

Safety Best Practices Manual

Field Start-Up Sheet Direct Fired Gas Equipment

Overview of Presentation. Airflow Control: Why. Air Barriers and Energy

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

INSTALLATION INSTRUCTIONS

N Grasses ORNAMENTALS. Grasses

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

IWTS Series IWTS-5 LCR & IWTS-10 LCR In-Wall Theater System Speakers. Instruction Manual

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Pellet Stove. Flex Pipe. Appliance Connector

INSTALLATION INSTRUCTIONS GT4011EE TWO POINT HOIST

OSHA Table 1

Snap Trim and Clips JANUARY, 2017 EC INDEX

ALABAMA. Downloaded

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

key-lock installation guide key-lock Concealed Suspended Ceiling Systems

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) Environmental and Occupational Health and Safety Manual

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES HEAT PUMP INSTRUCTIONS D INSTALLATION DE LA POMPE À CHALEUR SÉRIE 47000

Peninsula woodburning fireplace. Models (V)PN36-A

Specified Exposure Control Methods When Working With Materials Containing Crystalline Silica

EccoTone Acoustic Wood Panels Installation Manual

HEAD OFFICE, SECURITY DEPARTMENT

INSTALLATION and OPERATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Technical and Dimensional Data. Saf-T Vent SC Plus

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Transcription:

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing If you have questions during installation please contact Regupol at 717-675-2190 regupol-acoustics.com 800.537.8737 x119 1

Regupol SonusClip Sound Isolation Clip SonusClip & Furring Channel 1 5/8" Maximum Spacing: 48" o.c. Maximum Design Load: 36 lbs (16 kg) 3" SonusClip Dimensions: 3" tall (76mm) 1 1/4" wide (32mm) SonusClip with drywall furring channel 1 5/8" deep (41mm) 1" Drywall Furring Channel Minimum requirement: 25 gauge hemmed edge detail required on all 25 gauge furring channel Note: Drywall Furring Channel must be 25 gauge and hemmed Depth: 7/8" (22mm) Bottom Width: 2 9/16" to 2 11/16" nominal. (65mm to 68mm) Width Top: 1 1/4" (31mm) 1 5/8" Note: Splice drywall furring channel with 6" overlap in mid span between two SonusClips. Secure with 18 gauge wire or two 7/16" framing screws 7/8" 2 9/16" to 2 11/16" 2 1/2" coarse thread screw Fasteners of SonusClip to framing Wood framing #8 x 2 1/2" coarse thread screw *for ceilings installation use 3" long screws Minimum pull out and sheer of 120 lbs 1 5/8" fine thread screw Steel framing # 8, #10, #12 x 1 5/8" self tapping fine thread screw. Tighten fasteners until they snug up into the metal washer Note: SonusClips should not be overtightened. 2 acoustics@regupol.com Installation Instructions for Walls & Ceilings

Installation Instructions for Walls & Ceilings Wall Installation Instructions for one or two layers of 5/8" Gypsum Board I Layout SonusClip row spacing based upon framing (ie 16" or 24", see page 5). II Locate the first row of SonusClip/channel within 3" to 6" from the floor and within 3" to 6" from the ceiling. III IV V VI Use a chalk line to layout the remaining rows, making sure to not exceed 24". SonusClip shall have a maximum spacing of 48" o.c. (refer to layout drawings on page 5). Fasten the SonusClip to the stud / joist using the approved fasteners. Tighten fasteners until they snug up into the metal washer. It is important that the SonusClip are not over tightened. VII Install the drywall furring into the SonusClip. Start by placing the bottom edge of the channel into the SonusClip and squeezing inward to snap the channel into place. VIII Additional SonusClip are required on end walls (see drawings page 5). IX X XI If joining 2 pieces of furring channel, make sure they re in the middle of the stud cavity and overlap by 6". Use wire tie (18ga wire) or 2ea 7/16" steel framing screws. Before installation of gypsum wall board install 1/4" to 3/8" shims to hold the gypsum board off the floor. There be at least a 1/4" gap around the perimeter where the wall meets the ceiling. Secure the drywall to the furring channel using 1 5/8" drywall screws. Make sure the gypsum board is screwed to each furring channel before removing the shims. XII If installing additional layers of gypsum board, repeat steps X XII Note: offset the seams / joints between layers of gypsum board for increased acoustical performance. XIII Caulk around all perimeter edges using a smoke-sound sealant. XIV After caulking has set, tape and mud as usual. General information Minimum allowable thickness for steel studs is 20 gauge (0.030-0.037 ) (0.8-0.9mm) Furring channel must be fully supported, do not cantilever the channel more than 6 away from SonusClip Drywall Furring Channel must be 25 gauge and hemmed SonusClips are not designed to carry heavy wall mounted weights such as cabinets or bookshelves regupol-acoustics.com 800.537.8737 x119 3

Regupol SonusClip Sound Isolation Clip Ceiling Installation Instructions for one or two layers of 5/8 Gypsum Board I II III IV V VI Layout SonusClip row spacing based upon framing (ie 16" or 24", see page 5). Locate the first row of SonusClip/channel within 6" of wall. Use a chalk line to layout the remaining rows, making sure to not exceed 24". SonusClip shall have a maximum of 48" o.c. (refer to layout drawings on page 5). Fasten the SonusClip to the joist using the approved fasteners (3" screws are recommended). Tighten fasteners until they snug up into the metal washer. SonusClip must not be overtightened. VII Install the drywall furring into the SonusClip. Start by placing the bottom edge of the channel into the SonusClip and squeezing inward to snap the channel into place. VIII Furring channel must be fully supported additional clips may be required at end walls. Additional clips & channel will be required around HVAC openings. IX X XI If joining 2 pieces of furring channel, make sure they re in the middle of the cavity and overlap by 6". Use wire tie (18ga wire) or 2ea 7/16" steel framing screws. Gypsum board must have a 1/4" gap around the perimeter edges where ceiling meets the walls. If installing acoustic batt insulation. check the UL design as it may require closer furring channel spacing. XII Secure the drywall to the furring channel using 1 5/8" drywall screws. Make sure the gypsum board is completely screwed to each furring channel. XIII If installing additional layers of gypsum board, repeat steps X XII. Note: offset the seams / joints between layers of gypsum board to improve acoustical performance. XIV Caulk around all perimeter edges using a smoke-sound sealant. XV After caulking has set, tape and mud as usual. 4 acoustics@regupol.com Installation Instructions for Walls & Ceilings

Installation Instructions for Walls & Ceilings Wall & Ceiling Layout Guide for Wood or Steel Framing Framing 24" o.c. SonusClip at 24" x 48" o.c. 1 or 2 layers of 5/8" Gypsum Board 3" to 6" Furring Channel 24" Regupol SonusClip 24" x 48" o.c. Wood or Steel Framing at 24" o.c. 3" to 6" 48" 24" Framing 16" o.c. SonusClip at 24" x 48" o.c. 1 or 2 layers of 5/8" Gypsum Board 3" to 6" Furring Channel 24" Regupol SonusClip 24" x 48" o.c. Wood or Steel Framing at 16" o.c. 3" to 6" 48" 16" regupol-acoustics.com 800.537.8737 x119 5

Regupol SonusClip Sound Isolation Clip Product Accessories Screw and Metal Washer (by others) Regupol 3D Isolation Washer, 1/4" (rubber only) 1/2" Diameter Hole Regupol Sill Isolation Pad, 6mm 3D Isolation Washer Sill Isolation Pad Sonus Underlayment SonusClip DE90 information at: regupol-acoustics.com Download or request additional information about the Regupol family of Sound Control, or Vibration Isolation products at Regupol-Acoustics.com 2018 REGUPOL AMERICA LLC 11 RITTER WAY LEBANON, PA 17042 Regupol is a registered trademark of BSW Technology on your wavelength is a registered trademarks of Regupol America REGUPOL AMERICA SONUSCLIP US RAAP-2018.03.0013