Benchtop Test Chambers Temperature and Humidity

Similar documents
Benchtop Test Chambers. Temperature and Humidity

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

The best test chambers...

The best test chambers...

Walk-in Test Chambers Panelized & Solid Construction

Temperature Cycling Chambers Global-N Series

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

Benchtop & Compact Test Chambers

Walk-in Test Chambers. Panelized & Solid Construction

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Z-Plus. Temperature/Humidity Chambers.

Z-Plus Series Temperature/Humidity


Compact design for personal use Ready to network with your computer.

VWR symphony CO 2 INCUBATORS

Faster Temperature (& Humidity) Chamber

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Compact Ultra Low Temperature Chamber

Remote Conditioners. RC-Series. ZPRC Series

Remote Conditioners. RC-Series. ZPRC Series

Environmental.

Z-Plus Temperature/Humidity Chambers

Thermal Shock Chamber TSE 11

Bench-Top Type Temperature (& Humidity) Chamber

Faster Temperature (& Humidity) Chamber

Stability & Shelf Life

Environmental Stress Chamber AR series

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Quality is more than a word

Altitude Chambers.

Environmental Chambers

halt & hass systems

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

NEW! TSX Series high-performance undercounter refrigerators

NEW! TSX Series high-performance undercounter refrigerators

Stability Chambers & Rooms

Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Industrial Freezers &

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

GENERAL DESCRIPTION. LRE.com 1. CHAMBER

Thermo Scientific Precision Ovens

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

TCC-34. Features: TISSUE CULTURE

Blanket and Solution Warming Cabinets

Controlled Environment Equipment Solutions for the Lab

Constant climate chamber with humidity

Reach-In. PLanT GROWTh. Reach-In

Environmental.

Constant climate chambers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Constant climate chambers

SPC-56 SHORT PLANT.

FORCED-AIR LABORATORY OVENS

Environmental Chambers Series: reach-in & benchtop capacities

Environmental simulation chamber for complex alternating climate profiles

Protection, safety, reliability. And more.

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Installation Operation Maintenance Manual Z-Series

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Methods of Desiccation

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Constant climate chambers

Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Laboratory & Pharmacy Refrigerators

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Auto Technology Company Cyclic Corrosion Test Chamber

TECUMSEH MALAYSIA SEMI HERMETIC CATALOGUE

Espec Chamber User Manual Hydgechalkoles Wordpress

TCR. Features: TISSUE CULTURE

Glassware washer STEELCO

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Technical Specification of High and Low Temperature Altitude Test Chamber

StableClimate Stability Chambers

Constant climate chambers

NEW INTELLIGENT AIR TECHNOLOGY

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Selecting an Environmental Test Chamber

Transcription:

Benchtop Test Chambers Temperature and Humidity

Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they can be configured to accommodate your specific requirements. Their narrow footprint saves valuable lab space. 2

Benchtop Features Models save valuable lab space ESPEC introduces our expanded Criterion Series. With a narrower footprint and increased performance, these test chambers provide an economical and space-saving solution for cramped labs needing to do a variety of temperature (and humidity) testing. All of the Criterion models have a 19.5 inch wide interior, which is 3.5 inches more than traditional benchtops, yet the exterior is 20% narrower. The four cubic foot models have the largest workspace found in a benchtop unit, while maintaining the smallest exterior footprint. For additional space savings, the refrigeration system ventilates out the top, and utility connections are on the sides, thus allowing installation directly against a wall. With the electrical system behind the hinged control panel, minimal space allowance is required on the sides, as well. Big chamber performance The extended temperature ranges of the Criterion series make testing at extreme conditions possible without buying a larger, stand-alone chamber. Units are available that go as cold as -70 C. The four cubic foot models also offer a choice of humidity control. With a range from 10 to 95%, you can maximize your testing options. A low humidity system can extend this range even farther. (See humidity chart on page 7 for details.) Size Comparison 1.5 cu. ft. 4 cu. ft. The Criterion series has two chamber sizes: 1.5 and 4 cubic feet. The interior width for both sizes is 19.5 inches. The exterior footprint for both sizes is the same, just 30" x 33.5". BTZ & BTX all models BTU-433 & BTL-433 ( C) -50 0 50 100 150 200 BTU-133 12" 11" Temperature Range Comparison 24" -70 180-35 180-20 180 15" The BTZ & BTX models have extended cold temperature ranges without requiring liquid nitrogen. The BTU & BTL still offer sub-freezing testing capability. Faster temperature changes The Criterion series can cycle temperatures at rates up to 5 C/minute without requiring liquid nitrogen. Significant test time can be saved, as well as creating added thermal stress on your samples. Performance Comparison 180 150 100 BTZ-175: 5 C/m BTZ-133: 3.5 C/m To demonstrate performance, ESPEC uses the international standard IEC 60068 3-5 measured at the supply air. Temperature cycles are run from hot to cold extremes, and the middle 80% of the transition is timed to determine performance. Your actual cycling results will vary depending on methodology, including the start and end temperatures, and the amount of samples loaded. 50 0-50 -70-100 0 30 60 90 120 150 180 min. The Criterion chambers respond quickly to setpoint changes. The BTZ-175 can save 30 minutes or more per cycle. 3

Benchtop Features Space-saving design An innovative new layout of system components helps make Criterion chambers have the smallest footprint. Keeping the refrigeration compressors and blower fan to the back of the chamber also reduces noise to the room. Test Area Useful safety features To protect from the risk of overheating, there are three levels of protection: 1. Settable within the programmer 2. An independent settable monitor 3. A thermal fuse In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber. If the chamber is shut down, the interlocked device will also be shut down. Highly reliable operation The Criterion platform has been reengineered from the ground-up to be consistent, reliable, and easy to maintain. ESPEC stands behind the chambers with a comprehensive one-year parts and on-site labor warranty. The chamber's fan continuously circulates conditioned air from the test area to the plenum (to the right of the test area), where the heaters, cooling coil, and humidity inlet are located. (BTX-475 model shown). Quality cabinet construction ESPEC is meticulous about making a chamber that is more than just functional. Stainless steel exterior and interior Rounded corners for easy cleaning Durable thermoformed plastic door and control panel Full thermal break around doorframe and door Rotating door latch is easy and secure Dual-layer insulation of fiberglass and expanded foam for thermal integrity One 2" (50mm) diameter cable port on the left, with an impervious, flexible silicone plug Easy lift-off service panels Floor drain and drip-tray under the doorframe A nonmetallic thermal break around the door and doorframe stops transfer of heat/ cold to the exterior. (BTZ-133 shown with optional shelf and window.) 4

Instrumentation Watlow F4 controller The Watlow F4 is a popular, easy to use, programmer/controller for test chambers. It stores up to 40 different test profiles (total 256 steps). Programming step-types available are: ramp, soak, jump/repeat, auto-start, and end. The F4 includes RS-232C serial interface and software. Optional remote access via Ethernet is possible, as well as software upgrades for full datalogging capability. One event relay with external output terminal is included for activating other equipment during operation. Options Cabinet Options Humidity Options Roll-around cart with storage cabinet (suitable for chart recorder placement) Cable ports: 2", 4", or 6" diameter (50, 100, or 150mm). One 2" port is standard on the left wall. Adjustable stainless-steel shelving Heated viewing window, 6"x6" (150x150mm) with interior light Operational Options Liquid nitrogen (LN ) injection 2 boost for faster cooling Solid-state humidity sensor in place of wet-bulb External water supply tank with recirculating capability Water filter (de-ionizing type) Extended low humidity range to 5% (see chart, page 7) Instrumentation Options RS-485 interface (in place of RS-232C) WatView software upgrade for full data-logging capability Ethernet access for F4 Cart Paperless recorder Cable port Window Window Emergency stop 'mushroom' button Yokogawa paperless recorders with optional Ethernet Overcool protector (overheat is standard) Honeywell circular-chart recorders Yokogawa strip-chart recorders Emergency stop button Control sensor output for customer use ESPEC humidity system expertise Controlling humidity in a small environmental chamber can be especially challenging. ESPEC's expertise in humidity control brings intelligent design that is carefully integrated into the BTL-433 & BTX-475. The humidity subsystems are designed for reliability, convenience, and performance: An external steam generator allows expanded range and is easy to maintain. A separate de-humidification coil improves low humidity control and range. The wet-bulb humidity sensor is an accurate primary measurement method. It is economical, easy to maintain, and reliable because it has no risk of failure due to over-saturation. Direct water supply connection is standard, with options for water filtering and external tank. Humidity tank removes for easy cleaning 5

SPECIFICATIONS - 1.5 c u. ft. models Model BTZ-133 BTZ-175 BTZ-175E BTU-133 Temperature Range -70 to 180 C (-100 to 354 F) -35 to 180 C (-31 to 354 F) Change Rate (per IEC 60068 3-5) 3.5 C/m heat-up 3.5 C/m cool-down 5 C/m heat-up 5 C/m cool-down 2 C/m heat-up 2 C/m cool-down Temperature Fluctuation ± 0.5 C per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C) per IEC 60068 3-6 Live Load Capacity 200 W to -40 C 300 W to -40 C 200 W to 0 C Interior Volume 1.5 cu. ft (42 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 11" x 12" (500 x 280 x 300 mm) 30" x 33.5" x 34" (760 x 850 x 865 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x2 (cascade) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 100 cu. ft./min. (2.8 m3/min.) Site Requirements Power 120V 1ph 60Hz 16A max. 208/230V 1ph 60Hz 12A max. 230V 1ph 50Hz 12A max. 120V 1ph 60Hz 16A max. Weight 300 lbs. (136 kg) 350 lbs. (159 kg) 300 lbs. (136 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 2000 BTU/Hr 3000 BTU/Hr 2000 BTU/Hr Gravity Drain Room Temperature 3/8" NPT Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualification (see page 3). 180 150 BTZ-133: 3.5 C/m BTZ-175(E): 5 C/m BTU-133: 2 C/m 100 50 0-35 -50-70 -100 0 60 120 180 240 300 350 min. 1.5 cu. ft. (this page) 4 cu. ft. (next page) Accessories included with each chamber: RS-232 configurator software by Watlow Cable port plug Power cable with plug (115V is NEMA 5-20, 208/230V is NEMA 6-20) Box of wet-bulb wicks (BTL/BTX) Operations & programmer manual, parts list & schematics on CD. 6

SPECIFICATIONS - 4 c u. ft. models Model BTL-433 BTX-475 BTZ-475 BTU-433 Temperature Range -20 to 180 C (-4 to 354 F) -70 to 180 C (-100 to 354 F) -20 to 180 C (-4 to 354 F) Change Rate (per IEC 60068 3-5) 1.5 C/m heat-up 1.5 C/m cool-down 2.75 C/m heat-up 2.5 C/m cool-down 1.5 C/m heat-up 1.5 C/m cool-down Temperature Fluctuation ± 0.5 C, per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C), per IEC 60068 3-6 Live Load Capacity 190 W to 0 C 300 W to -40 C 190 W to 0 C Humidity Range 10 to 95% RH, per chart below - Humidity Fluctuation ±5% RH per IEC 60068 3-5 except measured in supply air - Interior Volume 4 cu. ft (110 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 15" x 23.6" (500 x 380 x 600 mm) 30" x 33.5" x 47" (760 x 850 x 1150 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x1 (single-stage) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 200 cu. ft./min. (5.6 m3/min.) Site Requirements Power 120V 1ph 60Hz, 16A max. 208/230V 1ph 60Hz 12A max. 120V 1ph 60Hz, 16A max. Weight 350 lbs. (160 kg) 550 lbs. (250 kg) 350 lbs. (160 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 2000 BTU/Hr 3000 BTU/Hr 2000 BTU/Hr Gravity Drain 3/8 NPT Humidity Water Supply Supply: 3/8 NPT, 30-50 psig Typical usage: 0.5 gallons/day Purity required: 0.2 μs/cm to 10 μs/cm - Room Temperature Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualification (see page 3). 180 150 100 50 0-20 -50-70 -100 BTL / BTU-433: 1.5 C/m BTX / BTZ-475: 2.5 C/m 0 60 120 180 240 300 350 %RH Controlled humidity range for BTL-433 & BTX-475 models (without live load). Optional low humidity range shown in red. 95 80 60 40 20 20 40 60 80 85 7

: http://www.espec.com/ 4141 Central Parkway, Hudsonville, MI 49426, U.S.A. Tel:1-616- 896-6100 Fax :1-616 - 896-6150 ESPEC EUROPE GmbH Dachauer Strasse 11, D-80335, Munchen, Germany Tel :49-89-1893-9630 Fax :49-89-1893-96379 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO.,LTD. F5,ShenHua Financial Building,NO 1 NingBo Road, Huangpu District Shanghai,200002,P.R.China Tel :86-21- 51036677 Fax :86-21- 63372237 ESPEC (MALAYSIA) SDN. BHD. No.10-1, Jalan Dagang SB 4/2, Taman Sungai Besi Indah Off Jalan Sungai Besi, 43300 Seri Kembangan Selangor Darul Ehsan Malaysia Tel :60-3-8945-1377 Fax :60-3-8945-1287 http://www.espec.co.jp/english 3-5-6,Tenjinbashi,Kita-ku,Osaka 530-8550,Japan Tel :81-6 - 6358-4741 Fax :81-6 - 6358-5500 DANGER Not for use with specimens which are explosive or flammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or an explosion. BTL-BTZ CRITERION July. 2010