Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

Similar documents
Product Data BW9 WATER BOILER SERIES B

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

AFUE 95% Heating Input 50,000 to 200,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Boiler & Water Heater

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

GB Condensing Gas Boiler

G6RC Series TECHNICAL SPECIFICATIONS

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Commercial Tankless Rack System

Installation, Start-up, and Operating Instructions

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Residential/Commercial Gas Condensing Tankless Models

Commercial Tankless Rack System

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

13 GEP A L P - 1 A

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

Suggested Specifications Prestige Excellence 110

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Commercial Tankless Rack System

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Commercial Tankless Rack System

MERIT SERIES Downflow

GMS9/GCS9 SERIES 93% AFUE

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Cooling Capacity CFM in. w.c. (125 Pa)

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Residential & Commercial

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

WM97+ Wall Mount Boiler

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Wt. Lbs Model Number (BTUH) Hz

RGE 13 A T - 1 A

Ultra Boiler Series 1 & 2 Jacket Parts

Cooling Capacity CFM range

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

RG7D 1-Stage Heat Series

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

GB Condensing Gas Boiler

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

Residential Gas Tankless Water Heater

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Date: Project #: Engineer: Prepared By: Bid Date:

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

355MAV Sizes 040 thru 120 Series E

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Cooling Capacity CFM in. w.c. (125 Pa)

Raptor 320HB & 399HB Submittal Sheet

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Utica Boilers MAC Submittal

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TSTAT0101SC Recommended (order separately)

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

Cooling Capacity CFM in. w.c. (125 Pa)

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Peerless Boilers. Series MI. Residential Gas Boilers

TECHNICAL SPECIFICATIONS

Transcription:

Product Data Model BW9 Gas-Fired Condensing Water Boiler Series A best way to obtain plenty of clean combustion air. The induced draft fan draws in the outside combustion air, then takes the cooler flue gases from the heat exchanger and provides a positive removal of the flue gases from the building through inexpensive and readily available PVC and CPVC pipes. FEATURES MODEL BW9 Series A The BW9 is a gas fired direct vent condensing hot water boiler with cast aluminum heat exchanger sections. A revolutionary cast aluminum heat exchanger means better heat transfer and thermal storage than similarly sized cast iron boiler, which results in higher efficiency. The heating system water absorbs large amounts of heat from the cast aluminum heat exchanger, cooling the flue gases and causing condensation. Sealed combustion, premix gas burner, and low flame temperature means drastically reduced CO and NOx emissions, which contribute to a cleaner and healthier environment. The BW9, unlike normal residential atmospheric and induced draft boilers, takes its combustion air directly from the outdoors (sealed combustion) and does not compete with building occupants for fresh air. Sealed combustion (also know as direct vent ) is the safest and Range of Capacities Seven sizes ranging from 50,000 through 200,000 Btuh input. Completely Packaged Each boiler is completely assembled, including all controls (except room thermostat and circulator pump). All necessary wiring is factory installed. The boiler is ready for gas piping, room thermostat, and electrical power connections as shipped. Circulator is shipped pre-wired with 6 ft bx conduit for easy installation for supply side pumping. Venting This boiler is direct vented with PVC and CPVC pipe. See the Installation Instructions for common venting requirements. Aluminum Sections These sections speed heat transfer to the boiler water. With faster thermal response, greater comfort and economy are achieved. Pre-Mix Burner Provides quiet operation and improved combustion efficiency. Controls Integrated Boiler control provides safe, dependable operation of burners. Factory-installed safety components provide maximum safety against overheating, pressure buildup. A factory installed low water cut-off is standard on the BW9-125 through 200 sizes and is available as a field installed accessory on the BW9-50 through 100 sizes. Sections Tested Each section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers. Propane Convertible With factory approved accessory conversion kit. Warranty The aluminum sections are covered by a limited 15-year warranty on the entire assembly. All other parts are covered by a 5-year limited warranty. As an ENERGY STAR Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency. ama Copyright 2005 Carrier Corporation Form BW9A-2PD

Model number nomenclature BW9AAN000075AAAA B W 9 A A N 000 075 A A AA B Boiler Variations AA Standard Type of System W Water Combustion/Ignition 9 90% Direct Vent /Sealed Combustion/HSI Series A Original Labeling A Common Unit G Canada Only (Oil) Model Code Electrical A 110 to 125 60 Hz Heating Size Btu Input (x 1000) Fuel N Natural Gas Cooling Boiler accessories BW9 DESCRIPTION Filltrol Package (Up to 75,000 BTUH) Filltrol Package (Up to 150,000 BTUH) Filltrol Package (Up to 300,000 BTUH) High Limit Control L6006C1034 Zoning Valve 3/4-in. Zoning Valve 1-in. Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-050) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-075) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-100) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-125) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-150) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-175) Gas Conversion Kit, Combination Natural to Propane and High Altitude Derate (BW9-200) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-050) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-075) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-100) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-125) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-150) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-175) Gas Conversion Kit, Combination Propane to Natural and High Altitude Derate (BW9-200) Concentric Vent Kit 2 inch Concentric Vent Kit 3 inch Low Water Cut-Off Kit (for BW9-50/75/100 only Factory Installed BW9-125 through 200) Note: Accessory High Limit Control is a strap-on aquastat used as an auxiliary limit or reverse acting circulator control. PART NO. KBAFP0101DNK KBAFP0201DNK KBAFP0301DNK KBAHL0101DNK KBAZV0101DNK KBAZV0201DNK KBANP1101DNK KBANP1201DNK KBANP1301DNK KBANP1401DNK KBANP1501DNK KBANP1601DNK KBANP1701DNK KBAPN1101DNK KBAPN1201DNK KBAPN1301DNK KBAPN1401DNK KBAPN1401DNK KBAPN1401DNK KBAPN1401DNK KGAVT0501CVT KGAVT0601CVT KBALW0101DNK 2

Dimensions Model BW9-50/75/100 ALTERNATE OPENING FOR GAS SUPPLY ALTERNATE SUPPLY & RETURN OPENINGS (1-1/4" NPT (31.75mm) CONNECTIONS PROVIDED INSIDE BOILER CABINET) BOILER WATER TEMPERATURE & PRESSURE GAUGE FRONT PANEL DOOR PULL 5" (127mm) VENT CONNECTION (2" CPVC) (50.8mm) ACCESS PANEL LEVELING FEET DRAIN CONDENSATE DRAIN FITTING (1/2" PVC) (12.7mm) GAS SUPPLY OPENING (1/2" NPT) (12.7mm) JUNCTION BOX FOR 120 V POWER, 120 V CIRCULATOR BEADS, AND 24 V THERMOSTAT LEADS VENT CONNECTION (2" CPVC) (50.8mm) OPENING FOR RELIEF VALVE DISCHARGE PIPE OPENING FOR AIR VENT AND EXPANSION TANK CONNECTION COMBUSTION AIR INTAKE FITTING (2" PVC) (50.8mm) ALTERNATE GAS SUPPLY OPENING ALTERNATE OPENING FOR VENT TEE ALTERNATE BOILER WATER SUPPLY AND RETURN (31.75mm) CONNECTIONS (1-1/4" NPT BOILER CABINET) PROVIDED INSIDE STANDARD BOILER WATER SUPPLY & RETURN OPENINGS (1-1/4" NPT (31.75mm) CONNECTIONS PROVIDED INSIDE BOILER CABINET) A99156 CLEARANCES (In.) UNIT COMBUSTIBLE ACCESSIBILITY/CLEANING SERVICING TOP 1 8 8 LEFT SIDE 1 24 24 RIGHT SIDE 8 BASE 1 FRONT 0 24 24 BACK 1 INTAKE/VENT PIPING 0 NEAR BOILER HOT WATER PIPIING 1 *Service clearance requirement 24 in. Physical data UNIT SIZE 050 075 100 Sections GAS CONTROLS 1 Gas Valve Honeywell Inlet Size In. 1/2 Ignition Hot Surface Ignition Burner Stainless/Titanium Alloy 1 Burner Orifice (No orifice sizes for 125, 150, 175, 200 No. 0.0615 #48 #44 CONTROLS Limit Control Range F 100-200 Pressure Relief Valve Setting Psig 30 Integrated Boiler Control UTEC factory installed CIRCULATOR Taco Model 007 Full Load Amps 2.0 AMPS/330 WATTS Flange Size FPT In. 1-1/4 3

Dimensions Model BW9-125/150/175/200 OPENING FOR RELIEF VALVE DISCHARGE PIPE OPENING FOR AIR VENT AND EXPANSION TANK CONNECTION JUNCTION BOX FOR 120V. POWER & 24 V THERMOSTAT LEADS STANDARD SUPPLY & RETURN OPENINGS 1 1/4 NPT CONNECTIONS PROVIDED INSIDE BOILER CABINET. VENT CONNECTION (2 CPVC) COMBUSTION AIR INTAKE FITTING (2 PVC) TOP 32 5/16 20 1/8 GAS SUPPLY OPENING (1/2 NPT) 40 1/4 25 1/4 4 7/16 6 1/4 LEFT SIDE VENT TEE (2 CPVC) FRONT RIGHT SIDE BACK CONDENSATE DRAIN FITTING (1/2 PVC) LEVELING FEET A04049 CLEARANCES (In.) UNIT COMBUSTIBLE ACCESSIBILITY/CLEANING SERVICING TOP 1 8 8 LEFT SIDE 1 24 24 RIGHT SIDE 8 BASE 1 FRONT 0 24 24 BACK 1 INTAKE/VENT PIPING 0 NEAR BOILER HOT WATER PIPIING 1 *Service clearance requirement 24 in. Physical data UNIT SIZE 125 150 175 200 Sections 1 GAS CONTROLS Gas Valve Honeywell Inlet Size In. 1/2 Ignition Hot Surface Ignition Burner Stainless/Titanium Alloy 1 Burner Orifice (No orifice sizes for 125, 150, 175, 200 No. None, Venturi CONTROLS Limit Control Range F 100-200 Pressure Relief Valve Setting Psig 30 Integrated Boiler Control UTEC factory installed CIRCULATOR Taco Model 007 Full Load Amps 2.0 AMPS/330 WATTS Flange Size FPT In. 1-1/4 4

Circulator curve 12 1 WATER FLOW M 3 /H 2 3 4 5 10 TOTAL HEAD FEET 8 6 4 3 2 1 TOTAL HEAD METERS 2 0 4 8 12 16 20 24 WATER FLOW GPM WATER BOILER CIRCULATOR CURVE Electrical data ALL MODELS Voltage Hertz Phase 115 60 1 Minimum Branch Circuit Wire Size (AWG) 14 Maximum Fuse Size or CKT BKR (Amps) 15 Control Circuit Power Available 40va@ 24v Time-delay type is recommended Performance data* UNIT GAS TYPE MAX INPUT (BTUH) RATINGS HEATING CAPACITY* Btuh AFUE % NET RATING BOILER WATER CAPACITY (GALLONS) BW9AAN050 Natural 50,000 45,000 90 39,000 2.6 256 BW9AAN075 Natural 75,000 68,000 90 59,000 2.6 256 BW9AAN100 Natural 100,000 90,000 90 78,000 2.6 256 BW9AAN125 Natural 125,000 113,000 90 98,000 3.0 284 BW9AAN150 Natural 150,000 134,000 90 117,000 3.0 284 BW9AAN175 Natural 175,000 158,000 90 137,000 3.0 284 APPROX SHIP. WT (Lb) BW9AAN200 Natural 200,000 180,000 90 157,000 3.0 284 * Gas input ratings are for elevations up to 2000 ft. In the USA, for elevations above 2000 ft., reduce input per the charts supplied in the high altitude derate kits. In Canada, boilers may be used at high altitidue by using a certified field conversion kit. Btuh 5

6

7

Carrier Corporation Indianapolis, IN 46231 5-05 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Page 8 Printed in U.S.A. PC 101 Form/Catalog No. BW9A-2PD Tab 6a 8a Replaces: BS1A-7PD