Fired Heater Flooding

Similar documents
Process Burner Flames: Good, Bad & Ugly

HYDROCARBONENGINEERING June June 2015

Burners Flares Incinerators Vapor Combustion

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

SULPHUR RECOVERY UNIT

Amec Foster Wheeler- Fired Heater Division

Eclipse Self-Check UV Scanner

DIRECTIVE NO: D-B

The key element for your process

Feed Interruption Three separate incidents within Marathon petroleum. p Garyville 2005, 05 Coker Unit - Feed interruption/furnace tripped caused by wa

OPERATING AND MAINTENANCE MANUAL

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Diocese of Cleveland Facilities Services Corporation

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

defence Prior to 1947 in the USA, process vent streams The last line of

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

WHAT TO DO IF YOU SMELL GAS

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

THE WORLD S FIRST FLAMELESS CRUDE HEATER

The World s First Flameless Crude Heater

User s Information Manual

DETECTING FLAME INSTABILITY AND/OR LOSS OF FLAME IN FIRED HEATERS USING ADVANCED PRESSURE DIAGNOSTICS

user s information manual

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Committee on NFPA 85

Fall Boiler Start-up, Fuel System Tips to keep you Safe

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Evacuation Fire Safety Program

Document code: 1 (10) Issuing date: Status:

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Manhattan Fire Protection District

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

Overview of Gas Range Types

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

USER'S INFORMATION MANUAL

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

S. P. THERMAL SYSTEMS INC.

USER'S MANUAL PGE Single Package Rooftop

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

AE R4 July 2015 Guide for the Use of R-290 Refrigerant in Copeland Refrigeration Compressors

An Oven Explosion Lessons Learned on PSM Concepts (or PSM: It s not just for breakfast anymore )

Eclipse 90 UV Scanner Model A Version 1

INDITHERM. Low temperature gas burners

Natural Gas & Propane Burners

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Fuel-Fired Vertical Tubeless Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

Good Ideas For Propane Safety

Coker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX

Cleaver-Brooks Webinars

Considerations for INDUSTRIAL COMBUSTION

Fuel and Energy Research Forum

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Specifications of V-Line burners

Corporate. Management. Line. Management. Plant. Manager HSSE. Maintenance Manager. (Plant. Operations Manager. Process Safety) Plant.

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

Guideline for Fire Safety Plan

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

PACKAGED COMMERCIAL WATERTUBE BOILERS

Power Flame Incorporated

THE SIGNIFICANCE OF RELIABLE PRESSURE CONTROL IN OILFIELD BURNER SYSTEMS

Propane Flame Projector Safety instructions and operating manual

Low pressure boiler* inspection and maintenance

COMBUSTION & FIRED HEATER OPTIMIZATION AN ANALYTICAL APPROACH TO IMPROVING SAFE & EFFICIENT OPERATIONS

Instructions for High Altitude Installations Above 4500 FT.

REFRIGERATED RECIRCULATORY COOLER

SECTION P3 LINE HEATER

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Installation and Testing of Inverted Bucket Steam Traps Manual

INSTALLATION, OPERATION & MAINTENANCE AVANTCO SERIES 177AG OWNER S MANUAL

Fire-Water Bowls Model 100

GRAND EFFECTS Fire-Water Bowls Model 100

ATMOX MAXX System THE Complete Moisture Control System for Crawlspaces. User s Guide

Safety & Installation Instructions

DOMESTIC WATER HEATER OIL FIRED

USER S INFORMATION MANUAL

Compliance Guidance for non-technical managers

Figure 10 or Figure 6

Incident Summary (Reference # )

INSTALLATION AND MANINTENANCE INSTRUCTIONS

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Packaged Gas/Electric

Cast Iron Commercial Hot Water Or Steam Boiler

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

HFID Heated Total Hydrocarbon Analyzer Module

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

RAMBLER PARK FIRE SAFETY INFORMATION

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Corn Flame Energy Corn Stove Model 3000

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

Transcription:

Fired Heater Flooding Chuck Baukal Doug Basquez Mike Pappe Director, JZ Institute Energy Coordinator End User Sales & Service 918.234.2854 316.321.8387 661.588.5095 charles.baukal@johnzink.com douglas.basquez@hollyfrontier.com mike.pappe@johnzink.com Bill Johnson Bill Weimer John McGuire Aftermarket Support End User Sales & Service End User Sales & Service 918.234.5742 985.288.5551 713.443.1078 bill.johnson@johnzink.com william.weimer@johnzink.com john.mcguire@johnzink.com Page 1

Important Notice The information contained in these materials is for informational purposes only and is provided AS IS, without warranties of any kind. Your use of the information contained herein is at your sole risk. We expressly disclaim any express or implied representations, warranties or guaranties, including without limitation, the implied warranties of merchantability and fitness for a particular purpose. We will have absolutely no liability (whether direct, indirect or consequential) in connection with these materials (and/or the information contained therein) including without limitation, any liability for damage to person or property. We also reserve the right to make subsequent changes to the materials without prior notice. For purposes of this notification, We includes John Zink Company LLC and its affiliates and their respective employees, partners, principles, agents and representatives, and any third-party providers or sources of information or data. johnzinkhamworthy.com/trademarks 2017 John Zink Company, LLC Page 2

Outline Definition Causes Indication Response Examples Prevention Page 3

API 535: Burners for Fired Heaters in General Refinery Services (May 2014) 14.2 Flooding Flooding (substoichiometric operation) is a term used to indicate operation with insufficient combustion air, resulting in unburned fuel or combustibles in the firebox and/or flue gas. As the furnace is typically on automatic coil outlet temperature control, the lack of combustion within the firebox allows the outlet temperature to reduce and the control system calls for more fuel exacerbating the situation. The cycle, if unabated can eventually lead to burner flameout. Before this point the unburned hydrocarbons can result in afterburning. Page 4

Heater Flooding Incident Outside operators: Sent to check flames Saw low CO reading Smelled gas Saw heater huffing & puffing Saw deflagration blow open heater wall Issues: CO analyzer not in service due to maintenance (not in turnover report to next shift) Low O2 alarm incorrectly set too low Heater ran out of air Reduced heater temps = call for more fuel which flooded heater Page 5 5

API 535 (cont d) 14.2 Flooding (cont d) Flooding on a natural draft heaters is generally accompanied by erratic firebox pressures or panting at the furnace air inlets. With too much fuel and too little air, combustion ceases, pressure is reduced in the firebox allowing more air to enter, as combustion develops, pressure increases in the firebox excluding the air once more. It is the small differential pressures across the natural draft burners that make this situation prevail. It is less prevalent with forced draft systems where cross limiting air fuel ratio control can prevent this situation. Pressure drop across the burners and combustion air system dampens the effect of the increases/decreases in combustion inducted pressure changes. Page 6

Unstable Heater 0-0.3 +0.3 Draft 0 3 %O2 Page 7

Refractory Damage When heater becomes flooded, firebox may shudder, huff, or woof repeatedly. This eventually can cause damage to refractory & heater tubes. Page 8

Simple Definition of Fired Heater Flooding Too much fuel in the heater Page 9

Fired Heater Flooding Flooding is a condition in which several or all of the burners alternately flameout & reignite Bogging is fuel rich operation of the heater to a point where all burner flames are out Page 10

Good Operation Stack temp. Bridgewall temp. 500 of Burners & heater working as designed * Pilots & BMS not shown 1550 of Oil in Excess O2 -.1 H2O 3% XS O2 0.0 CO Arch draft Tube temp. 815 of Oil out 18 psig Fuel pressure Page 11

Flooded Heater & After Burning High stack temperature High tube metal temperature High fuel pressure Low O2 850 of 1850 of Oil in +.5 H2O 0% XS O2 5000 CO 1115 of Oil out 28 psig Page 12

Outline Definition Causes Indication Response Examples Prevention Page 13

API 535 (cont d) 14.2 Flooding (cont d) Other possible causes of flooding may include: Fuel compositions beyond the recommended limits of the burner Low draft leading to insufficient air entering the burners API 556 discusses methods of addressing unburned combustibles within the fuel fired heater protective system. Page 14

Possible Causes #1 Mechanical Issues Stack damper positive draft in firebox Burner registers set too low for firing rate Fans failure or set too low for firing rate Instrumentation failure/not calibrated (e.g., O2, CO, draft, fuel flow) Fuel control valve fails to respond Plugged/fouled gas tips Burner flame outs Tube failure Page 15

Possible Causes #2 Fuel Changes Sudden loss of H2 in fuel Switching to natural gas Sudden addition of heavies (e.g., C3s, C4s) Liquid fuel carryover Page 16

Possible Causes #3 Operational Failures Dampers not adjusted to allow change in operation Burners ramped up too fast Heater operated to draft limit Sudden process feed changes in volume, temperature, or composition Notification that analyzers, dampers, valves are in manual, or being worked on Page 17

Outline Definition Causes Indication Response Examples Prevention Page 18

Indication of Possible Flooding Hazy firebox After adjustment Page 19

Fuel Rich vs. Clean Firebox Heater flooded, fuel rich firebox Clear firebox, burners adjusted Page 20

Fuel Rich vs. Clean Firebox Flooded heater, hazy firebox Heater after adjustment Page 21

Fuel Rich Firebox Note this tube has fallen & is in front of tube below Page 22

Fuel Rich vs. Clean Firebox Long tailing cloudy flames, haze visible in the firebox Clear firebox, no haze Page 23

Outline Definition Causes Indication Response Examples Prevention Page 24

General Response What to do: Reduce fuel flow rate until pulsing stops & flooding is corrected Page 25

If flames become unstable Page 26

Slowly cut back on the fuel Reduce fuel until heater stabilizes Page 27

General Response What not to do: Do not go to heater Do not adjust stack damper or burner air registers Do not shut down heater Page 28

Response Outside Operators DO NOT GO TO HEATER Evacuate any personnel in vicinity Do not open sight doors (added air could cause fire or explosion) Radio to control room to advise Page 29

Response Inside Operators Notify outside operators to stay clear of heater & to get any other personnel out of the area Slowly cut back on fuel until flooding is over (suitable excess O2 measured) If burners flame out, cut fuel to heater Page 30

Outline Definition Causes Indication Response Examples Prevention Page 31

Hydrotreater Incident #1 What Happened Heater tripped (flame scanner problems) Problems relighting Block valves manually bypassed (w/o using proper procedures) due to dropping heater temperatures Multiple relights attempted, purge steam permissive already satisfied so no purge on last attempt Heater detonated Page 32

Hydrotreater Incident #2 Analysis Original trip caused by false loss of flame due to pilot flames blocking sight of main flames Subsequent loss of flame shutdowns were real; heater box was rich in fuel gas & flame was snuffed out Results No mechanical damage No one injured Page 33

Hydrotreater Incident #3 During start up, bypass around heater fireman was open. Excess volume of fuel gas pushed heater outlet temperature well above target. Burners were cut off. When they were put back on, fuel gas (due to open bypass) rushed into heater & detonated. Page 34

Heater Incident Primary gas tips plugged, excess oxygen low, added air instead of reducing fuel, resulting in heater incident Vacuum heater s burner tips fouled even after steam-out: rock inside gas tip Page 35

Heater Incident Incident occurred on hot oil heater Significant damage sustained to heater side walls No injuries or loss of containment from process Root Cause: Unburned fuel accumulated in heater, most likely due to flooding or flameout of #6 burner Fuel accumulation was ignited during attempt to light a burner #8 Page 36

Heater Flooding Incident Heater started up after routine shutdown As burners brought on, not enough air available causing heater to huff Air registers opened providing air that ignited flooded heater Before After Page 37

Fired Heater Flooding Indications of flooding include: Low O2 (<0.5%) and/or high combustibles (>1000 ppm) are first indication of a potential firebox flooding situation Rapid drop in coil outlet temperatures and/or firebox bridgewall temperatures Drop in COT causes firing rate to increase due to closed loop control & worsens flooding condition of heater Loud rhythmic whoosh sound or vibration Pulsating / unsteady flames Local draft gauge swinging widely Hazy appearance in firebox or smoke from stack (during severe bogging) Page 38

Fired Heater Flooding Causes for fired heaters being prone to flooding include: Large swings in fired duty on a regular basis Significant variances in fuel heating value Air registers or stack damper are fixed or manually operated Heater is air limited Delayed O2 analyzer response times Heater has exhibited signs of severe flooding in the past Page 39

Fired Heater Flooding Response Do Immediately reduce fuel input Personnel should stay away from immediate fired heater area if flooding is suspected Don t Do not automatically trip heater in this situation Sudden removal of all fuel from a rich firebox may result in a flammable mixture that could auto-ignite Do not take any steps that may increase air into firebox, e.g. damper adjustments, opening observation doors, etc. Page 40

Outline Definition Causes Indication Response Examples Prevention Page 41

Flooding Prevention Adjust heater operation before major fuel changes Maintain instruments: O2, CO, draft, etc. Communicate with maintenance, especially about any instruments out of service/not working Include anti-bogging controls in heater control scheme Page 42

Flooding Prevention Consider: Adding red flashing light at heater during flooding incident or high CO Adding Burner Management Systems (BMS) to shut down heater during flame outs Adding alarms for: High fuel pressure Low combustion air flow / High combustibles Sudden drop in bridgewall temperatures Reviewing existing flooding procedures Page 43

Conclusions/Recommendations Heater flooding is a very serious condition that must be dealt with properly Procedures must be in place & followed Training is critical Equipment must be properly maintained Page 44

Chuck Baukal Doug Basquez Mike Pappe Director, JZ Institute 918.234.2854 Energy Coordinator 316.321.8387 End User Sales & Service 661.588.5095 charles.baukal@johnzink.com douglas.basquez@hollyfrontier.com mike.pappe@johnzink.com Bill Johnson Bill Weimer John McGuire Aftermarket Support 918.234.5742 End User Sales & Service 985.288.5551 End User Sales & Service 713.443.1078 bill.johnson@johnzink.com william.weimer@johnzink.com john.mcguire@johnzink.com Page 45