DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

Similar documents
BOC FS125 The Fire Extinguishing Solution

DuPont ISCEON 9 Series Refrigerants

HFC-227ea FIRE SUPPRESSION SYSTEM

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

How can I protect invaluable assets and the environment from the effects of a fire?

FIRE SUPPRESSION SYSTEM

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Fire suppression systems for server rooms and data centres

Safe, Effective, Environment-friendly

Retrofit Guidelines for DuPont ISCEON M029 (R-422D) Refrigerant

GX-20/FM-200 Fire Extinguishing System

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Refrigerants. Refrigerants with the Future in Mind

MINIMAX FIRE PRODUCTS WHITE PAPER THE COST-BENEFIT ADVANTAGES OF REPLACING HALON WITH 725 PSI MX 1230 CLEAN AGENT FIRE SUPPRESSION SYSTEMS

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Superior by Design The Kidde ADS TM FM-200 System

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

Solkane High Performance Refrigerants

How can you minimize consequential damages in case of a fire?

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

An Overview of Extinguishing Systems for Computer Equipment

Welcome to Argonite fire protection from Ginge-Kerr

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

3M Novec Fire Protection Fluid

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

R-404A Alternative with Low Compressor Discharge Temperature

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

MONTREAL PROTOCOL ON SUBSTANCES THAT DEPLETE THE OZONE LAYER UNEP HALONS TECHNICAL OPTIONS COMMITTEE. Technical Note #1 Revision 3

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

Suppression of Class C Fires

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Adequate protection of enclosed facilities

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Rick Seidel Fike Corporation Regional Sales Manager

Creating a safer world!

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION

Suva refrigerants. Suva 134a (HFC-134a) for Mobile Air Conditioning. Technical Information. Introduction. Transition to HFC-134a

ODS & SGG Alternatives for the Fire Protection Industry 2018

Fire Extinguishing Agents for Protection of Occupied Spaces in Military Ground Vehicles

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Water Mist Fire Suppression

SAPPHIRE. Gaseous Fire Suppression Systems. Delivering 3M Novec 1230 Fire Protection Fluid

R-407A R-448A R-449A

CO2 COCO GAS FLOODING SYSTEM

Silane Coupling Agents. Combination of Organic and Inorganic Materials

Fire Protection in the Mining Industry. Garry Kwok Board Member

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

New Refrigerants Designation and Safety Classifications

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Hospitals and Major Medical Centers

Sinorix Silent Extinguishing Technology protecting the quiet way

Connected: Global protection, all together

investment in R&D, the commitment to - name.

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

WILDLIFE AND ASSET PROTECTION PRODUCTS

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

What extinguishes fires without pressure peaks?

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

This application note describes the introductory procedure of Renesas Peripheral Driver Library for RX families. 1. Overview... 2

SO SMART, YOU WILL CALL IT INTELLIGENT

Passive cooling of telecommunication outdoor cabinets for mobile base station

FPA Australia submission to the review of the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 and associated legislation.

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP

CERTIFICATE OF FIRE APPROVAL

STAT X - SPECIAL HAZARD FIRE PROTECTION

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

SB/ESB SERIES THERMAL PROTECTORS

MISSION CRITICAL FIRE PROTECTION

MADE IN ITALY. thermowatt.com. the heart of electric appliances

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

ISO INTERNATIONAL STANDARD

Limitorque FR Shells Removable Intumescent Fireproof Coatings

that sense s of ecurity

RZ/A1H Group APPLICATION NOTE. Renesas Starter Kit Web Engine Demonstration for e 2 studio. Introduction. Target Device. Development environment

Materials. Powering Ideas.

US PRODUCT GUIDE. Products that perform...by people who care

PACKAGED REFRIGERATION EQUIPMENT

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Chapter 2. Alternatives to HCFCs and their Characteristics

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

CONTENTS. bawa-speci, Ver Maintenance. 1. INTRODUCTION: 1.1 bawa-speci Version 01

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

GLUE Fire resistant adhesive for FIREPRO fire protection systems

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

This application note indicates the example of power supply circuit used Simple DC/DC for RZ/A series.

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Transcription:

DuPont FE-25 FIRE EXTINGUISHANT Preferred Replacement for Existing Systems and the Choice for New Applications

FE-25 is particularly well-suited for sensitive appliactions, such as clean rooms

Protecting What Matters Most There is no question that DuPont FE-25 is the preferred clean agent replacement for construction and new applications. DuPont is committed to working with its partners in the marketplace to develop solutions that add value to the fire protection industry, improve the safety and quality of life for people around the world, and provide you with peace of mind. Our goal in fire protection, like that of our customers, is to protect people and valuable assets it s what matters most. The loss of data and archives can be devastating to a business. FE-25 protects your information and keeps the data flowing.

A Tradition in Safety DuPont is proud to continue its tradition of safety with FE-25 as the preferred replacement for existing systems, new construction or new applications. With FE-25, DuPont is the only supplier capable of providing a full range of non-ozone-depleting fire extinguishants for both new and existing systems on a global basis. Through the miracles of science, DuPont continues to reinforce its commitment to safety, environmental stewardship, and technology leadership. FE-25 offers the easiest, most cost-effective option to retrofit existing systems. FE-25 requires minimal system modifications, minimizes downtime, reduces costs of conversion, is approved for use in occupied areas, has a hold time superior to alternative agents, and protects what matters most. Collateral damage from water or dry chemicals can be as devastating as fire and smoke. FE-25 protects high-value assets such as sensitive computer equipment and vital data. Why FE-25? DuPont FE-25 has excellent physical properties such as flow characteristics and vapor pressure. The pressure traces, vaporization, and spray patterns for FE-25 nearly duplicate that of Halon 1301. FE-25 has a low boiling point, and can be used and/or stored at sub-freezing temperatures. The low boiling point also leads to rapid dispersion throughout an enclosure. The improved flow of FE-25 versus other potential alternatives allows for remote cylinder storage DuPont FE-25 is HFC-125, pentafluoroethane.

Safe for People The EPA, NFPA and ISO have accepted and incorporated the use of a physiologically based pharmacokinetic (PBPK) model to determine allowable human exposure limits for halocarbon agents. The PBPK model provides a more accurate assessment of the length of time that a person can be exposed to a chemical. In essence, the PBPK methodology raised the allowable concentration for FE-25 in occupied spaces from 10.0% to 11.5%. The typical design concentration for FE-25 is 8.0%, within the prescribed limits. The PBPK model brings scientific analysis to a process that was previously incomplete to determine safe human exposure requirements. While a reliance on animal testing techniques and associated findings still exists, it is recognized that people may vary in their level of sensitivity to these types of agents. The PBPK process requires that a statistical method is run to identify safe exposure levels and egress times for humans with the highest levels of sensitivity. This process requires that highly sensitive humans are used for setting safe exposure levels. Scientific adaptation of cardiac testing from animals to humans (factoring in the most sensitive human levels to set limits) makes the PBPK model a safer mechanism to establish appropriate human exposure levels. DuPont FE-25 protects people. It is suitable for use in normally occupied spaces for Class A fire hazards. Safe for Assets DuPont FE-25 is electrically non-conductive, non-corrosive, free of residue, has zero ozone-depletion potential (ODP) and is an environmentally preferred alternative. As a clean agent, FE-25 mixes thoroughly in air and does not leave behind any residue, which would cause damage or pose a post-fire clean-up problem. This means no collateral damage and minimal business interruption. DuPont FE-25 is intended to protect people, high value assets, and the continuity of business. In total flooding applications, FE-25 is well-suited for enclosures such as a ship s engine room to prevent a disaster at sea.

Safe for the Environment FE-25 is an environmentally preferred alternative; it does not contain chlorine or bromine and therefore has zero ODP. FE-25 has relatively low global warming potential (GWP) compared with other commercially available agents. Combined with its low GWP, less FE-25 is required by weight than other alternatives, leading to a reduced environmental footprint. Overall environmental impact is also minimized by improved detection technology and extremely low discharge rates into the environment. Properties of DuPont FE-25 FE-25 is an environmentally preferred alternative for existing and new applications. With no chlorine or bromine, FE-25 is an ozone-friendly clean agent. Chemical Formula CF 3 -CHF 2 Chemical Name Pentafluoroethane ASHRAE Designation HFC-125 Molecular Weight 120.02 Boiling Point 48.3 C 55 F Liquid Density @ 25 C 1189.7 kg/m 3 @ 77 F 74.27 lb/ft 3 Vapor Pressure @ 25 C @ 77 F Ozone Depletion Potential Atmospheric Lifetime 1381.5 kpa 200.4 psia Zero 32.6 years Relative Volume Storage Requirements At Design Concentration Levels for Class A Hazards 25 20 15 10 5 *Other DuPont Clean Agent Fire Extinguishants FE-36 FE-36 is an advanced, zero ozone-depleting replacement for Halon 1211 in streaming applications. It can also be used as a replacement for Halon 1301 in modular supression systems. Portable fire extinguishers using FE-36 have been listed by Underwriters Laboratories for use on Class A, B and C fires and are proving to be the standard in-kind replacement for Halon 1211. FE-13 FE-13 is a clean, environmentally acceptable, people friendly replacement for Halon 1301 as a total flooding agent under all use conditions. It is particularly applicable where high concentrations are needed for improved safety margins, the protected spaces are large, or where temperatures are likely to go below 0 C (32 F). 0 Halon 1301 FE-25 HFC-227ea Inert Gas FE-227 FE-227 is a clean agent fire extinguishant replacement for Halon 1301 with zero ozone depleting potential. It is used in total flooding applications for the protection of people and high value assets, such as those found in computer rooms, telecommunication facilities, museums, and clean rooms. The EPA and National Fire Protection Association (NFPA) classified heptafluoropropane or HFC-227ea as acceptable for total flooding of normaly occupied spaces at controlled concentration and egress times.

DuPont FE-25 protecting our planet and paving the way to the future.

DuPont Fluoroproducts Chestnut Run Plaza 702-1274-E Wilmington, DE 19880-0702 Tel: 800-473-7790 Fax: 302 999-4727 From Asia Pacific: DuPont Malaysia Sdn Bhd 6th Floor, Bangunan Samudra 1, Jin Kontraktor U1/14, Hicom-Glenmarie Ind. Park, 40150, Saha Alam Selangor, Malasia Tel: 60-3-5567 2534 Fax: 60-3-5569 2994 DuPont China Co. Ltd. 15th Floor Shui On Plaza 333 Huai Hai Road (Central) Shanghai, 200021, China Tel: 86-21-63866366 Fax: 86-21-63866333 DuPont Taiwan Limited 13F, Hung Kuo Building 167 Tun Hwa North Road Taipei, Taiwan 105 ROC Tel: 866-2-25144488 Fax: 886-2-25457098 E.I. DuPont India Private Limited 7th Floor, Tower C, Cybergreens Sector 25A, DLF City Phase 3 Gurgaon, Haryana -122002 India Phone: +91-124-4091818 / 4095100 Mobile: +91-9810440816 Fax No: +91-124-2540890 / 891/889 DuPont Far East Inc. Phillipines 19/F GT Tower International 8615 Ayala Ave. Corner H.V.Dela Costa St. Makati City, Phillipines 1227 Tel: 011 63 2 818 9911 From Europe, Middle East or Africa DuPont de Nemours International S.A. 2, chemin du Pavillion CH-1218 Le Grand-Saconnex Geneva, Switzerland Tel: 41-22-717-5081 Fax: 41-22-717-6169 www.dupont.com/fire The information set forth herein is furnished free of charge and is based on technical data that DuPont believes to be reliable. It is intended for use by persons having technical skill, at their own discretion and risk. The handling precaution information contained herein is given with the understanding that those using it will satisfy themselves that their particular conditions of use present no health or safety hazards. Because conditions of product use are outside our control, we make no warranties, express or implied, and assume no liability in connection with any use of this information. As with any material, evaluation of any compound under end-use conditions prior to specification is essential. Nothing herein is to be taken as a license to operate under or a recommendation to infringe any patents. Copyright 2005 DuPont or its affiliates. All rights reserved. The DuPont Oval Logo, DuPont, The miracles of science, Teflon, Nomex, Unitherm, FE-227, FE-36, FE-13 and FE-25 are registered trademarks of DuPont or its affiliates. H-96115-2 10/10