AZTECA A LITRE STERILISER

Similar documents
FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

laboratory & sterilization technology

CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

NC SERIES. Horizontal Steam Sterilizers

Large Steam Sterilizers. CELITRON COMPACT SOLUTION FOR BIOHAZARD WASTE DISPOSAL Integrated Sterilizer and Shredder (ISS)

STEAM STERILIZER SERIE S1000 (RBE)

NC SERIES. Bench Top Steam Sterilizers

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

NC 100. Vertical Steam Sterilizer

Large Steam Sterilizers for Life Sciences

OT 300/430/570 STEAM STERILIZERS

OT SERIES. Bench Top Steam Sterilizers

TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series

OT 300/430/570/710/850 STEAM STERILIZERS

Tabletop 2340 EA-D Class S Autoclave 19 Litres

LABOKLAV. Autoclaves Made in Germany

STERIDENT, STERIMAT, STERIMAT PLUS

Professional sterilization systems

MST sterilizer overview

Podiaclave+ The PodiaClave+ is specifically designed for the clinic based podiatrists and chiropodists.

AUTOCLAVE STEAM STERILIZERS (BENCH TOP)

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Operations Manual. Part Number: For Research Use Only

CLINOCLAV steam sterilizer AH-21 L

Introducing the latest model in Prestige Medical s first-class range of Advance autoclaves - Advance Pro.

A WORLD OF QUALITY, SAFETY AND HYGIENE STERILCLAVE. 18 litres-bhd/b/s

PRE AND POST VACUUM CLASS B AUTOCLAVE

cgmp STEAM STERILIZERS

Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

EZPlus Fully Automatic Sterilizers

Steam sterilizer AHS-75-DRY

Washer disinfectors Small - Medium range

VS LD series vertical steam sterilizers

TABLE TOP - STEAM STERILIZER Dental & Hospital Application

requirements can be equipped with an additional product temperature control probe, and with a printer.

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

B+N 18/23L LED. Ritter CleanTec with LED Display BB 18 + BB 23. Sterilizable Products:

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Dental instrument Washer Disinfectors

Constant climate chambers

SST2200 & Stainless Steel Steam Sterilizers SST1700 &

DENTAL TABLE TOP STERILIZER SERIES S CLASS MODEL : MO-MOST-T24/45/80.

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

LTE Scientific Ltd. Touchclave-PL Porous Load Steam Sterilizer

WASHER DISINFECTORS ISO ISO ISO 9001

STERIPLUS TM MEDICAL WASTE TREATMENT AT SOURCE HAZARDOUS BIO-MEDICAL WASTE TREATMENT THROUGH SHREDDING & STEAM AUTOCLAVING INNOVATION MADE IN FRANCE

Stability Chambers & Rooms

Bluestone Industrial & Trading Limited

Setting The Standards For A Safer Future

PERFORM Operating Document

Constant climate chambers

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

WASHER DISINFECTORS ISO ISO ISO 9001

Operation and Maintenance Manual

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

Getinge Quadro Tabletop Sterilizer Product Specification

Getinge 8666/8668 Washer Disinfectors

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

Protection. in un unica autoclave E10

DEKO Washer-disinfector WASHROOM SYSTEMS

Constant climate chambers

Multi-Lab REFRIGERATORS Frigidere medicale

BIOMEDICAL REFRIGERATORS

: 1.5kw/AC220V.50Hz (AC110V 60Hz) : 340*200*30mm (3piece) 400*200*30mm (3 piece)

Midmark Sterilizers. Connect. Flow. Save.

STERITITE INSTRUCTIONS FOR USE

Ultrasonic From delicate microsurgery instruments to heavy duty sets

Constant climate chamber with humidity

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Stability Studies? Walk in Stability Chamber BUY RENT SERVICE. Thermolab is a one stop solution for all your stability requirements

PRODUCT CATALOG MEDICAL AUTOCLAVE.

FITOCLIMA 600 & 1200 PHARMA

Washer disinfectors Small - Medium range

ULTRA.GUARD ultra low temperature freezer

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Kronos Class B Sterilizer

FORMALDEHYDE LOW TEMPERATURE STERILIZER Hospital & Laboratory Application

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Constant climate chamber with ICH-compliant illumination

Air Compressor Network compressed air (standard) R Compressor (built-in the equipment) R Compressor (separately)

STERILIZER STEAM - GLOBO 6412 INNOVATING TRADITION

Washer disinfectors. ML Series. Small and Medium range. Washer disinfectors for clinics & sub sterilization departments

laboratory & sterilization technology

BS En 285:2006+a2:2009 Description: Sterilization.

Refrigerators. Upright Blood Bank. i.series Horizon Series

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

Model KBF 240 Constant climate chambers with large temperature / humidity range

LTE Scientific Ltd. Touchclave-R. The dynamic new range of cylindrical-section autoclaves from LTE Scientific

OPERATION & MAINTENANCE MANUAL

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

SMALL STERILIZER SERIES 26 x 26 MODEL

MADE IN ITALY SERVICE INNOVATION QUALITY RELIABILITY

VS L range Laboratory Steam Sterilizers

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 KD 200/400/700 OVENS EV 018 VACUUM OVEN E V K D S E R I E S F N S E R I E S

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

Transcription:

Product Description Azteca A-6615 is a fully automatic high-speed pre & post vacuum steam sterilizer. This model is an electrically heated sterilizer, which operates with saturated steam as a sterilizing agent, and has a temperature range of up to 137ºC (279ºF) and pressure up to 2.3 bars (34 psi). The autoclave is classified as Class IIb according to MDD 93/42/EEC. The autoclave is designed as a Large Steam Sterilizer in accordance with EN285 and as Class I in accordance with EN60601-1, continuously operated, ordinary equipment without applied parts and without signal input-output parts. The device is not intended for use in the presence of flammable mixtures. The sterilizer includes the following features: Large capacity sterilization chamber Vacuum pump for evacuation of the chamber Fully automatic door locking system Water reservoirs for process and used water retention Water pump for water circulation Condenser and collector for condensation and collection of water Temperature sensors and a pressure transducer to monitor both vacuum and pressurized states Control valves operating at programmed intervals Application The unit is designed to cover a large field of applications for hospitals, CSSDs, laboratories, pharmaceutical and biotechnological industries. Dimensions Inner Chamber dimensions W x H x D: Chamber volume, net.: External W x H x D: Configuration and Options 700 x 700 x 1500 mm 740 Litres (10 STU) 1116 x 1950 x 1770 mm Model Heating Doors Azteca A-6615 Electric, 400V, AC Single or Double Available Accessories Impact Printer RS 232 Communication port SD Card & Reader HMI PC Software IQ, PQ, OQ SES 285 Sterilizer Evaluation System Reverse-Osmosis System Built-in Steam Generator Bio Shield Biohazard filter Side panels/cabinet Shelf rack Loading/Unloading cart ISO Baskets Water recycling system Silent Air compressor Languages The operator panel is set up with following standard languages (maximum 8 languages per sterilizer, more option available upon request): English Romanian Russian French Standards Azteca A-6615 complies with following standards and codes: CE 0473 Approved by the British Notified body Intertek AMTAC. EN 285:2006 Large Steam Sterilizers. Medical Device Directive (MDD) 93/42/EEC. EN 61010-1:01 Safety of electrical equipment General Requirements. EN 61010-2-040:05 Safety requirements for electrical equipment for measurement, control and laboratory use. EN 61326 (Directive 89/336/EE) (EMC) Emission compatibility. EN 61000-6-2; EN 61000-6-4 Electromagnetic compatibility (EMC)-Generic standards- Emission and Immunity for industrial environments. Pressure Equipment Directives (PED) 97/23/EC Essential safety requirements. ISO 17665-1:2006 Sterilization of health care products Moist heat Part : Requirements for the development, validation and routine control of a sterilization process for medical devices. Quality Management System Standards: ISO 9001: 2008 Quality Management Systems- Requirements. ISO 13485:2003 Quality systems - Medical devices - Particular requirements for the application of ISO 9001. EN ISO 14971 Risk Management for Medical device. AUSTRALIA Ph: 1300 009 663 Fax: 1300 099 300 Email: info@zonemedical.com.au 7/22 Mavis Court, Yatala, Qld, 4207 www.zonemedical.com.au NEW ZEALAND Ph: 0800 009 663 Fax: 0800 109 663 Email: info@zonemedical.co.nz PO Box 322 Dannevirke NZ 4942 www.zonemedical.co.nz

Standard features Microprocessor controlled steam sterilizer -Using steam under pressure as the sterilizing agent for wrapped or unwrapped goods such as fabrics, surgical instruments, utensils, and other heat and moisture stable materials at temperatures from 121 C to 134 C. The A-6615 sterilizer is a pre-and post-vacuum sterilizer designed to cover a large field of applications for hospitals, laboratories, pharmaceutical and bio-technological industries. Within the health care services, sterilization of medical supplies is an essential issue in the battle against the advance of many infectious diseases. In order to improve the quality of sterile supply, international standards, which specify the requirements for the equipment, and procedures in the sterilization departments in health care facilities, have been developed. Design and Construction - The Azteca A-6615 sterilizer meets the highest standards requirements for quality, safety and operation. The sterilizer s framework, piping and housing are also made of stainless steel. The highly efficient, highquality Hanno-Tech insulation material releases no particles; thus, the Azteca A-6615 can be used under clean room conditions. Chamber - The vessel, with a double full jacketed square chamber, is made of corrosion-resistant sandblasted stainless steel 316 L, and is thus easy to clean. Stainless steel pressure vessels 316 L conforms to the Pressure Equipment Directive (PED). The inner shell, door(s) and jacket are designed for a maximum working pressure of 2.76 bar and full vacuum. Exterior Stainless steel cover with or without stainless steel side panels. Vacuum system Equipped with a Liquid ring vacuum pump, combined with a heat exchanger, and is a pre- and postvacuum sterilizer having the following features: - An air removal stage (pre-vacuum), before starting the sterilizing stage. - A post-sterilization drying phase, based on the combined operation of heat and vacuum with air inlet pulses. In order to improve the efficiency of the vacuum pump capability and speed a heat exchanger is installed on the outlet piping of the chamber. The advantages of the pre-vacuum sterilizer are as follows: - Removal of air pockets from packs and porous load and most kinds of hoses (rubber, plastic etc.) by vacuum at the first stage of the cycle. - Better steam penetration into the load; resulting in effective sterilization. - Better temperature uniformity. - Better drying of materials due to the vacuum achieved in the chamber at the end of the sterilization cycle. Safety Devices Numerous safety features including: a safety valve, thermostat, a temperature sensor, a water detection electrode in the steam generator, pressure sensors, a door locking device and software safety features. Alarms Depending on the state of the input and of the installed accessories, the controller is capable of providing an audio alarm, as well as displaying and/or printing several alarms, including: Door Unlock Temperature/Pressure Error Low/High Temperature Low/High Pressure Low Vacuum and more. Door locking mechanism The door system is automatic and the sterilizer is equipped with one or two vertical sliding doors, provided with a pneumatic locking mechanism, activated by an air- operated valve, and safety pin preventing the opening of the door when the chamber is pressurized. Water system The sterilizers are equipped with 2 Water Reservoirs: one for the drain water and liquid ring vacuum pump and one for the mineral free water for saturated steam. Energy saving mode - The Sterilizers are equipped with an Energy Saving Mode which is activated when the unit is not used after a certain period of time. This Mode reduces power consumption by approximately 12% to 30% and is thus environmental friendly. Control system / Touch screen panel A microprocessor based control system, state of the art Free scale technology, automatically controls all programs including the sterilization cycle. The system includes a 5.7 digital touchscreen graphic display (for double door units 2 displays), communication, self and remote diagnosis and PC connection for external documentation and printing. It ensures a reliable, safe and user-friendly operation. The displayed information is available for users in a variety of languages. During the sterilization cycle the control system measures, controls and shows in digital display: the time, chamber pressure and sterilization status. While the power is off, the non-volatile memory keeps the status of the Sterilizer, and the real-time clock, driven by its own back-up battery, keeps running the date and time. Operation Operating is simple: close the door, select the cycle on the Touch-Screen Panel, and press the Start Key. The cycle will run automatically. At the end of the cycle, by pressing the Open Door button on the Touch-Screen Panel, the door will automatically open.

Printer The unit supplied with an integrated impact printer. Each cycle can be documented by the printer which records the preset and actual parameters of the cycle: the selected cycle, cycle parameters, date, time, temperature, pressure, errors, etc. The last 60 cycles data is automatically stored in memory, and can be re-printed. Options and Accessories Data collection Sterilization cycles data can be collected online trough standard RS232 connection, enables connecting the computer and the Sterilizer using the PC Software (optional). Sterilization cycles data can be also collected online on a SD Card through an optional SD Card Slot. Collected data can be downloaded into a computer equipped with proprietary PC Software. 2 Gigabyte SD card collects up to 40 years logging data, including: the selected cycle, start time, cycle stages, temperature / pressure, end time, cycle status (pass / fail), etc. An optional Ethernet Connection enables controlling, monitoring and connecting your Azteca A-6615 sterilizer with no need of additional software. Monitoring and Documentation Software (HMI Software) Powerful PC Windows based software is available for monitoring, logging control and service. Sterilizer Evaluation System (SES 285) A totally independent monitoring and documenting system, the SUPERVISOR, compares the parameters recorded by the basic automated sterilization process control system with the parameters recorded by its own completely independent sensor system. The SUPERVISOR performs a cross checking of the timing/stages/cycles of the sterilization according to the limits and tolerances defined in EN285, and sends it to the user alarms in case the parameters are not accepted. The SUPERVISOR is connected to a printer which registers all parameters and provides documentary proof of the sterilization processes. Bio Shield The bio-shield is used as a seal to prevent any cross contamination passing from the dirty side to the clean side of the room. The bio-shield is assembled only in a 2 doors autoclave. A metal flange is welded around the autoclave s jacket, to completely separate between sides. Biohazard filter This option is used to verify that no unsterilized materials will be taken out of the sterilizer. In order to implement this verification, the sterilizer is equipped with a special bio-hazard door safety system and other biohazard features: a bio-hazard filter and a water sensor electrode. Condense is collected in the chamber and removed to the drain, after being sterilized. In case a cycle fails, there is a risk of contaminant and bio-hazard, therefore opening the door is not allowed. In order to open the door, water shall be removed from the chamber by pressing the FLUSH key. Side panels / cabinet The Azteca A-6615 sterilizer can be purchased as a standalone unit with stainless steel side panels. Shelf rack Stainless steel shelf rack with 2 shelves. Loading/Unloading cart Stainless steel loading / unloading cart is available. For double door unit two carts are suggested. ISO Baskets Stainless steel wire baskets are available upon request (size: 300*300*600 mm). Water recycling system The water saving system is supplied to reduce the amount of water used during the sterilization (pre vacuum, sterilization, exhaust and drying) cycle. Silent Air Compressor - An electrically operated air compressor can be provided if there is a lack of available compressed air. The air is used to operate the unit s valves and power door. Reverse Osmosis (water softener) A Reverse Osmosis system shall be used to improve the quality of the water used to generate steam in the electric steam generator. The use of mineral-free water will contribute to better performance and longer life of the autoclave s chamber. The water purification system uses a high quality booster pump which can provide 6.8 bar water pressure to pass through the membrane even under low water pressure area. The booster pump prevents damage, prolongs the life of the membrane and improves solids +99% of all organics +99% of all bacteria. Steam generator The Azteca A-6615 sterilizer can be equipped with a built-in 63 kw steam generator, when central steam source is not available. The steam generator is made of stainless steel 316 L. The large capacity of the heaters enables steam to always be ready for operation, and thus contributes to a very fast cycle.

Cycle descriptions Azteca A-6615 offers 7 different cycles: 5 sterilization cycles, and 2 test cycles. Additional cycles are available upon request. The two available test programs are the Vacuum Test for checking the integrity of the chamber and piping system and the Bowie & Dick test which checks the efficiency of the sterilization process. t1 = Conditioning t2 = Sterilization stage t3 = Exhaust and dry stage 4 - Prion 134 C /18 min, 20 min dry Sterilizing wrapped instruments. Sterilization time: 18 minutes. Dry Time: 20 minutes. Average cycle time: 55 minutes. 6 Porous 121 C /20 min, 20 min dry Sterilizing of heat sensitive materials and textiles. Load weight <7.5 kg/1stu. With drying stage. Sterilization temperature: 121ºC, 0 C +3 C. Sterilization time: 20 minutes. Dry Time: 20 minutes. Average cycle time: 55 minutes. 1 - Flash 134 C /3 min (Warm Up). Sterilizing unwrapped instruments. Load weight <10 kg/1stu. Without drying stage. Sterilization time: 3 minutes. Average cycle time: 20 minutes. 2 - Unwrapped 134 C /3 min, 2 min dry (Dynamic sterilizer chamber pressure). Sterilizing unwrapped instruments. Sterilization time: 3 minutes. Dry Time: 2 minutes. Vacuum pulses: 4 Average cycle time: 21 minutes. 3 - Wrapped 134 C /3.5 min, 15 min dry Sterilizing wrapped instruments. Sterilization time: 3.5 minutes. Dry Time: 15 minutes. Average cycle time: 35 minutes. 8 Bowie and Dick Test 134 C /3.5 min, 1 min dry (Hollow load A) This is a test program, with fixed sterilization parameters of 134 C and 3.5 min., drying time of 1 min., which cannot be modified by the operator. Sterilization time: 3.5 minutes. Dry Time: 1 minute. Average cycle time: 21 minutes. 9 Leak Test (Vacuum test) The vacuum pump is activated until the pressure reaches a level of at least 15 kpa, all the valves and pump shut down. The following 5 min. is for the stabilization condition of the chamber. From now on along the next 10 min. the allowable decrease of pressure is 0.13 kpa / min. (or 1.3 kpa for 10 min.)

Technical Data Azteca A-6615 Cycle type (according to EN 285) External dimensions W x H x D Chamber volume, net. Chamber shape, type Inner Chamber Dimensions, W x H x D Approximate Weight Approximate Shipping weight Shipping dimensions W x H x D Mineral free water reservoir volume Average water consumption during the cycle Max. Water temp. at the reservoirs Max. Working pressure Min. Working pressure Jacket Peak sound level Max electric power without steam generator Max electric power with steam generator B 1116 x 1950 x 1770 mm (43.9 x 76.8 x 69.7 inch) 740 Litres. (195.5 gal) (10 STU) Square 316L, welded, sandblasted 700 x 700 x 1500 mm (27.6 x 27.6 x 59.1 inch) 1200 kg (2645.5 lb) 1400 kg (3086.5 lb) 1370 x 2210 x 1900 mm (53.9 x 87.0 x 74.8 inch) 8,5 Litres (2.25 gal) 225 Litres (59.4 gal) (depends on load and selected cycle) 65ºC (149ºF) 2.76 bar (40 psi) -0.9 bar (-13.5 psi) Double full jacket < 70 db Voltage fluctuation ±10% Operation Controls Display Integrated printer Connection to PC Maximum recommended solid load Maximum recommended textile load 2 kw, 3 phase, 400V 3 x 16A, 50/60 Hz 65 kw, 3 phase, 400V, 50/60 Hz Electronic with microprocessor Digital LCD Color Display, Resistive Touch Screen Yes -(Standard) Standard RS232, USB connection for service technicians and Ethernet connection as an option 10 kg (22.0 lb) / 1STU 7.5 kg (16.5 lb) / 1STU Number of Cycles Cycle type (stated load types) Sterilization temperatures Special / Test Cycles Air removal Drying system Suggested Cycle time (minutes) Stand-by Appearance of Face Automatic water filling Automatic water draining Door locking device 7 cycles - 5 sterilization cycles and 2 test cycles Wrapped or non-wrapped, solid, hollow load products Type A and porous products. 134-121 C Bowie & Dick test and Vacuum test Fractionated vacuum Vacuum Total time: Flash134-(20 min) unwrapped +hollow134 (21 min), prion, porous 134 (55 min), wrapped 134-(35 min) Yes Stainless Steel Standard Standard Fully automatic, pneumatic door locking device with safety pin AUSTRALIA Ph: 1300 009 663 Fax: 1300 099 300 Email: info@zonemedical.com.au 7/22 Mavis Court, Yatala, Qld, 4207 www.zonemedical.com.au NEW ZEALAND Ph: 0800 009 663 Fax: 0800 109 663 Email: info@zonemedical.co.nz PO Box 322 Dannevirke NZ 4942 www.zonemedical.co.nz