SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual

Similar documents
GTC15 Temperature Controller Operation Manual

QTC15 Temperature Controller Operation Manual

BTC15 Temperature Controller Operation Manual

QMF MAINFRAME Installation Manual

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

flexibility programmed settings.

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

SSV-DC user manual. Phason

TEMPERATURE CONTROLLER

TC515 and TC600 Installation Manual. a Winters company

SC Installation, Operation & Application Guide

RCS Residential Control Systems Inc.

Static Pressure Control

RC-2000 Thermostat Installation Instructions

Oakton TEMP 9500 Advanced Multiparameter Controller

Custom Products for Research. Kugelrohr Short Path Distillation

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

7-Day. Digital Thermostat. residential. & 2-cool

Mark 25 Ultrapure Water Conductivity Analyzer

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

General Purpose IO Technical Manual

Operating Instructions. Temperature and Humidity EC Control. Model 35YV93

DCC-2200 / DCC-2300 CLIMATE CONTROL MODULE for Vintage Air Gen II Modules

Beacon 800 Gas Monitor Operator s Manual

Series RMA Hot Runner Controller Operator s Guide

ACL TC 200 TEMPERATURE CONTROLLER

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Intelligent Electronic Enclosure Thermal Management Systems

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

5+2 Day. up to HEAT COOL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Pump-Down Controller MODEL 4052

MODEL AC-SCC-5 INSTALLATION, OPERATION & MAINTENANCE MANUAL

Protocol Station Remote Alarm

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual

CT500 Electronic Thermostat

Instruction Manual Model Backup Switch, 1 for 8

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

JDDT1 - Single Stage Digital Thermostat

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

CG Series Digital Temperature Controller OPERATIONS MANUAL

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

Chore-Tronics Load Cell Indicator

HEAT HEAT HEAT COOL COOL

Secondary Sensing System

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Ethernet General Purpose

User Manual DME Company

B-40/B-41 Modulating Temperature Controller

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

OWNER S MANUAL Venstar Inc. 08/07

Blade Series Heat Exchanger Operation and Installation

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

1 For All Programmable Digital Thermostat

Pump-Up Controller MODEL 4062

EasyTronic III MANUAL SERVICE

SKORPION Process Air Heater

MV2 SERIES Temperature Controller. Instruction Manual

CommStat 4 Controller

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Multiple Boilers Electro TS Series Application EB-C-STG5

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SC Installation, Operation & Application Guide

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

CA5000 Liquid CO 2 Freezer Backup System

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Single Station Remote Alarm

Application Manual Loop Water Controller

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Refrigerated air dryers

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Introduction... 1 System Overview... 1 System Diagram... 2

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

SC Installation, Operation & Application Guide

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

TEMPERATURE CONTROLLER (STANDARD MODEL)

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

eed quality electronic design USER s MANUAL

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Table of Contents SECTION PAGE

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

SC Installation, Operation & Application Guide

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Protégé Eclipse LED Keypad User Manual PRT-KLES

Inline Heater for Solvent or Gas. Installation and Operation Manual

Transcription:

SITC-15 Temperature Controller GITC-15 Temperature Controller Mainframe Operation Manual SITC Quick Reference:... GITC Quick Reference:... Basic Operation Procedures:. SITC Parameters:... GITC Parameters:... Contents: Pg. 2 Pg. 3 Pg. 4 Pg. 7 Pg. 8 Display Codes:... Pg. 11 Mainframe Installation:.. Pg. 12 Cable Pinout:... Pg. 15 MFCP Mainframe:... Pg. 16 1-3 Zone Mainframe... Pg. 17 PH: (407)855-2899 FAX: (407)855-2855 www.moldcontrol.com

SITC-15 Quick Reference Change set-point temp - or to desired set-point temp. Change mode - press until flashing LED is under desired mode, then Change parameters - press until desired perameter is found. Use or to adjust the parameter. when finished. Display Amps/Volts - press Set-Point Value Display Process Value Display When decimal is lit, manual percentage power is engaged When decimal is lit, voltage is displayed ± 3% When decimal is lit, temp. is displayed in Celsius When decimal is lit, amperage is displayed When decimal is lit, output power is on User Input Keypad Mode Indicator LEDs Up/down keys For adjustment of setpoint/ parameters Mode Select key Manual, Auto, Standby, and Boost Amps/Volt key View Current and voltage Parameter key Scroll through parameters Enter key Save changes Figure 1 SOFT - Soft Start MAN - Manual/Open loop AUTO - Auto/Closed loop STBY - Standby Mode BST - Boost Mode 2

GITC-15 Quick Reference Global power on/off - press Global setpoint - set desired setpoint, then press Global mode - press Global parameters - Set-Point Value Display Process Value Display When decimal is lit, manual percentage power is engaged When decimal is lit, output power is on When decimal is lit, voltage is displayed ± 3% When decimal is lit, K type T/C is selected When decimal is lit, amperage is displayed When decimal is lit, temp. is displayed in Celsius User Input Keypad Global key See Global Functions (Pg. 4) Enter/Start key Save changes or press once to exit Halt, or twice to start Halt key Halts the controller (inhibits output) Figure 2 3

Basic Operation Procedures The SITC-15 and GITC-15 temperature controllers are ready to run from factory settings. Global Functions for GITC only: GLOBAL FUNCTIONS allow individual controller parameters or modes to be sent to the system or groups of controllers. Group setup is confi gurable in parameter (GITC P01). Up to 4 groups can be set. GLOBAL POWER ON/OFF: power on or off all controllers from any controller. Key sequence: *GLBL*, *POWER*, then *ENTER/START* Note*: If a controller is manually powered off, the function is disabled until powered back on manually. GLOBAL SETPOINT/PARAMETERS: Adjust setpoint or parameters on a single unit, and send the settings to all controllers. Key sequence: *GLBL*, *PMTR*, then *ENTER/START* GLOBAL MODE CHANGE: Change the mode on a single unit, then change mode system wide or within a group. (e.g. STANDBY or BOOST) Key sequence: *GLBL*, *MODE*, then *ENTER/START* GLOBAL CURRENT/VOLTAGE VIEW: View current and voltage on all controllers in the system. Key sequence: *GLBL*, *AMPS/VOLT*, then *ENTER/START* Note*: If changes need to be made to individual controllers, just apply changes and press *ENTER*. Basic Operation: Turn power on by pressing the *POWER* button. SOFT START mode: The controller will start in SOFT START mode if the process value is below 212 F or 100 C. After the SOFT START duration time (parameter (SITC - P16); (GITC - P20), the controller will go into AUTO mode (factory default). Note*: MODE changes cannot be made during SOFT START mode unless the lock is disabled in parameter (SITC - P17); (GITC - P21). SETPOINT CHANGE: To change the setpoint value, use the *UP* and *DOWN* keys to select the desired temperature then press *ENTER*. The minimum and maximum values for temperature and setpoint are 32-999 Fahrenheit (5-650 Celsius). 4

Mode: There are 4 running modes available: manual (open loop), automatic (closed loop), standby (idle), and boost. A solid lit LED indicates the mode the controller is in. To change mode: Press the *MODE SELECT* key until the blinking LED is over the desired mode, then press the *ENTER* key. A solid lit LED will indicate the current running mode. Note*: To exit the mode function with no changes, press the *MODE SELECT* then the *UP* or *DOWN* key. Siren will momentarily sound when status changes occur (GITC only) (e.g. when BOOST is enabled). ENTER MUST BE PRESSED AFTER ANY ADJUSTMENT (SUCH AS SETPOINT, PARAMETER, OR MODE) IS MADE TO STORE NEW INFORMATION. Standby and Boost: The controller has two confi gurations for standby and boost modes: auto or manual. Standby: AUTO-STANDBY - controller goes to the preset standby set-point temperature set in parameter (SITC - P15); (GITC - P19). MANUAL-STANDBY - controller goes to the preset % power set in parameter (SITC - P14); (GITC - P18). The controller will remain in STANDBY mode until it is manually changed to another mode, or by pressing *MODE SELECT* then *UP* or *DOWN*. Boost: AUTO-BOOST - controller goes to the preset BOOST set-point temperature set in parameter (SITC - P12); (GITC - P16). MANUAL-BOOST - controller goes to the preset % power set in parameter (SITC - P13); (GITC - P17). Controller will remain in BOOST mode until preset time has elapsed, set in parameter (SITC - P11); (GITC - P15). 5

Parameter Changes: 1. Press the *PMTR* key until the desired parameter is reached. (List of parameters is available on (SITC - Pg. 7) (GITC - Pg. 8). 2. Press the *UP* or *DOWN* key to change the options for the selected parameter. 3. When complete, press the *ENTER* key to store to memory. (Changes can be made to all parameters before pressing *ENTER*). To exit at any time, press the *ENTER* key. Error Reset: Upon detection of TOH, TSH, or HIA, the controller must be powered off, then on, to clear the error once the issue has been corrected. Refer to Pg. 9 for error codes. Special Functions (GITC ONLY): Even Temperature Rise: controllers will follow the slowest rising temperature in the system. Even temperature rise is an active procedure, so fl uctuation will occur during rise. Thermocouple Slaving at Startup: At startup, in the event of a thermocouple break, the controller will slave from a controller in the same group. Live-Swap: In the event of a controller change-out, the new controller will automatically inherit the parameters and settings of the previous controller. External Alarm Output: Relay for external alarm or light. Pinout on page: 14 Remote Standby Input: Switch input for system standby. Pinout on page: 14 6

SITC Parameters # Parameters Defaults P01 Auto Power On - (YES or NO) YES P02 Control Type - Power Control Type Phase or Burst PH mode (PH or BT) P03 Over Current Limit - (1-21) Amps 16 P04 Celsius or Fahrenheit ( C or F) F P05 Thermocouple Type - (J or K) J P06 Over-temp. Alarm Limit - (8-30 Fahrenheit), (6-30 17 Celsius) P07 Under-temp. Alarm Limit - (5-30 Fahrenheit), (5-30 17 Celsius) P08 T/C Pinched - (1-250) seconds or (000 = disabled) 60 P09 Open TRIAC, Heater - (1-240) seconds or (000 = 30 disabled) P10 APO Enable - (YES or NO) YES P11 Boost Time Setting - (5-999) seconds 30 P12 Boost Temperature - (5-250 Fahrenheit), (5-75 120 Celsius) P13 Manual Boost Power - (5-100%) 25% P14 Manual Standby Power - (5-100%) 10% P15 Standby Temperature - (50-350 Fahrenheit), (50-250 175 Celsius) P16 Soft Start Time - (0-20) minutes 5 P17 Soft Start Lock - (YES or NO) YES P18 Audible Alarm - (YES or NO) YES P19 Keypad Lock - (YES or NO) NO P20 Frequency (Hertz) DISPLAY ONLY P21 Tune Stabilization - (50-100) 60 7

GITC Parameters # Parameters Defaults P01 Group - (1-4) 1 P02 TRIAC Shorted Time (0-20) 10 P03 Even Temperature Rise - (YES or NO) YES P04 Thermocouple Slaving - (YES or NO) YES P05 Auto Power On - (YES or NO) YES P06 Control Type - Power Control Type Phase or Burst PH mode (PH or BT) P07 Over Current Limit - (1-21) Amps 16 P08 Celsius or Fahrenheit ( C or F) F P09 Thermocouple Type - (J or K) J P10 Over-temp. Alarm Limit - (8-30 Fahrenheit), (6-30 17 Celsius) P11 Under-temp. Alarm Limit - (5-30 Fahrenheit), (5 30-17 Celsius) P12 T/C Pinched - (1-250) seconds or (000 = disabled) 60 P13 Open TRIAC, Heater - (1-240) seconds or (000 = 30 disabled) P14 APO Enable - (YES or NO) YES P15 Boost Time Setting - (5-999) seconds 30 P16 Boost Temp. - (5-250 Fahrenheit), (5-120 75 Celsius) P17 Manual Boost Power - (5-100%) 25 P18 Manual Standby Power - (5-100%) 10 P19 Standby Temp. - (50-350 Fahrenheit), (50-175 250 Celsius) P20 Soft Start Time - (0-20) minutes 5 P21 Soft Start Lock - (YES or NO) YES P22 Audible Alarm - (YES or NO) YES P23 Siren Enable LOCAL (per module) - (YES or NO) YES P24 Siren Enable GLOBAL - (YES or NO) YES P25 Address - DISPLAY ONLY P26 Tune Stabilization - (50-100) 60 P27 Keypad Lock - (YES or NO) NO 8

Parameter Description SITC-15 GITC-15 Description P01 Group - Set controller for specified group 1-4. P02 TRIAC Shorted Time - Time, in seconds, the controller will take to detect a TRIAC Shorted error. P03 Even Temperature Rise - Controllers follow slowest rising temperature in the system. P04 Thermocouple Slaving at Startup - At startup, in the even of a thermocouple break and controllers are below 140 F, the controller will slave from a controller in the same group. P01 P05 Auto Power On - After a power outage, controller will automatically power up upon the return of power if enabled. P02 P06 Control Type - Power output type (PH or BT) PH - half cycle phase mode BT - burst cycle mode P03 P07 Over Current Limit Detection - Maximum amperage controller will allow for load (Over Current Condition (HIA)). Recommended for user to adjust to heater current +10% for better protection. P04 P08 Select degrees Celsius ( C) or Fahrenheit ( F). P05 P09 T/C Type - Select thermocouple types J or K. P06 P10 Over-temp. Alarm Limit - Alarm when process temperature is over setpoint value as set in parameter. P07 P11 Under-temp. Alarm Limit - Alarm when process temp. is under the setpoint value as set in parameter. P08 P12 T/C Pinched - Time, in seconds, that the controller will take to detect a pinched or shorted thermocouple. (There is current, no rise in temperature). P09 P13 Open TRIAC/Heater - Time, in seconds, that the controller will take to detect an open TRIAC, open heater, or open wire. (No current and no rise in temperature). P10 P14 APO Enable - In the event of a T/C break and the controller is at set point, the controller uses the last average output power (APO) to maintain temperature. (Automatic Bumpless Transfer). T/C must be repaired as soon as possible. P11 P15 Boost Time Setting - Time, in seconds, desired for boost mode. 9

Parameter Description (c) SITC-15 GITC-15 Description P12 P16 Auto Mode Boost Temp. - Boost temperature over setpoint. (Boost temp. + setpoint) P13 P17 Manual Mode Boost Power - Manual percentage power output during boost mode for a set time (P15). P14 P18 Manual Mode Standby Power - Manual percentage power output during standby mode. P15 P19 Auto Mode Standby temp. - Standby/idle setpoint value. P16 P20 Soft-Start Time - Time duration, in minutes, that the controller is in Soft-Start. (Bake Out) P17 P21 Soft-Start Lock - Prevents users from changing mode while in soft-start. P18 P22 Audible Alarm Enable/Disable - controller audible alarm. P23 Local Siren Enable/Disable - siren alarm for the individual controller. P24 Global Siren Enable/Disable - siren alarm global. P25 Zone Address - Controller zone location in mainframe (Display only). P20 Frequency - AC line frequency (Display only). P21 P26 Tuning Stabilization - Adjustment for heaters with lagging thermocouple or low mass (quick heat dissipation heaters). If there is fluctuation of temperature, adjust higher (recommended maximum of 75). P19 P27 Keypad Lock - YES: Disables all keys, except for the *PMTR* key, to prevent unwanted changes. NO: All keys enabled. 10

Display Codes Display Codes: Displayed on PRT (process temperature display) Display Code Description Explaination Hi High Temperature Process temp. over setpoint value. Lo Low Temperature Process temp. under setpoint value. OTC Open Thermocouple Thermocouple is open or break. RTC Reverse Thermocouple Thermocouple wire reversed. PTC Pinched Thermocouple Thermocouple has been shorted/ pinched. TOH Open TRIAC/Heater TRIAC, heater is open. TSH HIA APO TRIAC/Heater Shorted Over Current Detection Average Power Output TRIAC or heater shorted. (100% power output) Load has exceeded the amperage set in parameters. Thermocouple is open and APO is currently running. GLO Global Function Global key has been pressed. (GITC only) NOTE: Power off controller before removing or inserting into mainframe J7 3 2 1 JUMPER Figure 3 Pin 1 & 2 - For newer style mainframes with anti-arcing protection. Pin 2 & 3 - For older style mainframes without anti-arcing protection. Anti-Arcing Protection: Jumper J7 is to prevent damage to the contact points of the controller when removed from the mainframe while power is still on. J7 is set to pins 1 & 2 by factory default. If the controller is placed in an older mainframe without anti-arcing protection, place jumper on pins 2 & 3. If jumper is placed incorrectly, a TOH error may occur (NO POWER OUPUT). 11

Mainframe Installation INSTALLATION AND SERVICE SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY! LOCATION: The proper location is important for dependable service. The control systems should be located so as to allow free air movement into and out of the mainframe. Consideration should be given to allow the least exposure to heat, dust/dirt, moisture, and corrosive vapors. The front of the system must be readily accessible for set up and adjustment purposes. It is recommended that a service disconnect switch be installed. This will provide a convenient means to completely disconnect all power from the temperature control system. CONNECTING INPUT POWER: 1. Remove the input power access panel, located on the right side of the mainframe by removing the 8 phillips head screws. (Fig 4a) 2. Select input cable size and confi guration based on load requirements and local electrical codes. Feed the cable through the cable clamp of the panel. (Fig 4b) 4. Strip wires and insert into the terminal block and tighten screws securely. (Fig 4a) 5. Replace the access panel. 6. Take up excess slack in the cable and secure with the strain relief clamp. 7. Route the AC input cable to a branch circuit (service) disconnect switch and connect to the fused side of the switch. Be sure the ground lead is attached to a proper earth ground. 8. Insert appropriate fuses for the main service fuse box. 12

Mainframe Input Power Diagram TERMINAL BLOCK Figure 4a Figure 4b Note: Domestic: L1, L2, L3 + ground Export: L1, L2, L3 + Neu + ground Single Phase: L1 + Neu + ground 13

Mainframe Interconnection to Mold Terminal Box Figure 5 See page 13 for pinout See page 13 for pinout 14

Figure 6a Power Connector Pinout Pin Zone Pin Zone Pin Zone A1 Zone 1 C1 Zone 8 A2 B2 Zone 5 C2 A3 Zone 2 B3 C3 Zone 9 A4 B4 Zone 6 C4 A5 Zone 3 B5 C5 Zone 10 A6 B6 Zone 7 C6 A7 Zone 4 B7 C7 Zone 11 A8 B8 C8 A9 Zone 12 C9 Zone 12 Figure 6b T/C Connector Pinout + WHITE 5 ZONE - RED 8 ZONE + WHITE - RED 12 ZONE + WHITE - RED ZONE 12 11 10 9 8 7 6 5 4 3 2 1 15

MFCP Mainframe (GITC ONLY) MFCP mainframes come with communication and interface board with siren, which enables global functions, grouping, thermocouple slaving, even temperature rise, and Live Swap features. External alarm relay, and remote standby interface connector is located on the right side above the power input panel. Figures 7, a, and b below shows connector and external wiring circuits needed for these functions. Alarm/Relay Output & Remote Standby Input Connector Pin # Function 1 Remote Standby Input 2 3 Alarm/Relay Output 4 Figure 7 Standby Input Pin 1 Input Signal Relay or switch (customer s source) Figure 7a To mainframe connector (Figure 7) Pin 2 Alarm/Relay Output Light or secondary alarm Match to source voltage Pin 3 External Voltage Source (Up to 240VAC 5A) To mainframe connector (Figure 7) Figure 7b Pin 4 16

1 & 2 Zone Mainframe Power and Thermocouple Connector Figure 8 Pin # Function 1 Power Output 2 T/C + 3 T/C - 4 Power Output 5 GND 3 Zone Mainframe Power and Thermocouple Connector Pin # Function Pin# 1 Zone 1 Power Out 9 2 Zone 2 Power Out 10 3 Zone 3 Power Out 11 4 NC 12 5 NC 13 6 Zone 1 T/C Input 14 7 Zone 2 T/C Input 15 8 Zone 3 T/C Input 16 Figure 9 Note: 1, 2, and 3 zone mainframes are wired for single phase 240VAC operation. 17

Warranty This product is guaranteed to be free from defects in materials and workmanship for a period of two years from the date of delivery. If the unit should malfunction, it must be returned to the factory for evaluation. Upon examination, if the unit is found to be defective, at our option, it will be repaired or replaced at no cost to the customer. Warranty does not cover: contact points, fuses, or triacs. Warranty is null and void when: Signs of abuse or tampering are found, incorrect fuse type is used, application of High Voltage rated over the system s required specifications, or application of High Voltage to thermocouple inputs. MCS accepts no responsibility or liablity for the APPLICATION by the customer of temperature controllers. This liability is assumed by the customer. Upon inspection, if the returned product does not meet our warranty requirements, customer may be subject to a reasonable service charge. There are no warranties, expressed or implied, for temperature controllers except as stated herein. In no event shall MCS be liable for consequential, incidental, or special damages beyond our control. The buyer s sole remedy for any breach of this agreement shall not exceed the purchase price paid by the buyer to MCS. Manufactured by: Mold Control Systems, Inc. 10501 S. Orange Ave. STE #108 Orlando, FL 32824 PH: 407-855-2899 FAX: 407-855-2855 2013 Mold Control Systems, Inc. All rights reserved.