Conditioning Hoppers. Installation and Electrical Wiring Guide

Similar documents
HG Million Btu/Hr Gas-Fired Heater

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

SERVICE MANUAL STEAMROLLER LINT CONDITIONER (MODELS SR & SR )

MODEL MW200 MODEL MW600 AIR DRYER

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

DEMA 830 Laundry Master TM Installation Instructions

Always keep this manual in a safe readily accessible location. MODEL SERIAL SERVICE COMPANY TELEPHONE NUMBER

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

Cotton Humidification Systems. from Samuel Jackson, Incorporated. Copyright 2002 SAMUEL JACKSON, INCORPORATED. All rights reserved

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

DRI-AIR INDUSTRIES HOPPER BANK OPERATING MANUAL

3. What are the main parts in a compressed air generation? And list the flow path in order? 4. Draw the ISO symbol for an air compressor.

Flopurge TS. Operation Manual

Installation Manual CARBONATOR With Plain-Water Booster

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

ECO1ZN3P, ECO2ZN4P ECO

HU King Mesa Gas-Fired Humidaire Unit

Telecab Residential Elevator OWNER S MANUAL

DEMA 844 Laundry Master Laundry Chemical Dispensing

INSTRUCTIONS FOR TAL SERIES VACUUM HOPPER LOADER

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

Telecab17 Residential Elevator OWNER S MANUAL

ARM SERIES Switching Relays With Priority

Installation Instructions

Installation Instructions

Flostop TS D7E and A8E. Operation Manual

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Monitored Pneumatic Valves On Series Ported Manifold

Energy management function at adsorption dryer PDAD

Bulletin , March Electric Hot Gas Bypass Valves

Multilift Vertical Platform Lift OWNER S MANUAL

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

½ Monitored Pneumatic Valves On Series Ported Manifold

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Humidistat-Thermostat

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

CleanSpray System Operation

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with K-style cordsets.

Industrial Refrigeration Defrost Solutions TM Package. Brochure R-222

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Installation Instructions

MODEL Vertical-Lift, 60, DC Power Lift, Manual Tilt

Installation Instructions

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

EEMAX ProAdvantage Series 1

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

ME SERIES ELECTRICALLY OPERATED BOILERS INSTALLATION - OPERATION - MAINTENANCE MODELS

WIRING MODEL 20 Low Water Cut-Off and Pump Control MAXIMUM PRESSURE: 20 PSI INTERNAL WIRING BLUE WHITE UPPER PROBE (FEED OFF) FEED PROBE (FEED ON) ALL

1022 R/T Remote Monitor

STARBUCKS UC100 PROGATE

RPI Industries, Inc.

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Frosty Factory of America, Inc.

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

TC-720 RECYCLING BALER

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Model Number Structure

STEAMPRO. Steam Generator Troubleshooting and Service Guide

Operator s Manual for Morse Hydra-Lift Drum Karrier Model 400A

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Statement of Responsibilities

PLAY IT SAFE! OPERATION, MAINTENANCE AND INSTALLATION MANUAL FOR VERTICAL RECYCLER BALER INCLUDING THESE MODELS:

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

Once the sensors are mounted and connected to the EGI-RLC-MM, each sensor needs to be adjusted as follows:

Operator s Manual for Morse Vertical-Lift Drum Pourers

MANUAL BOOK Sensor faucet

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

FLAKER/DCM SEQUENCE OF OPERATION

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Typical Mount Height. Combustion Chamber

INSTALLATION MANUAL. Double Electric Wall Oven

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

AR861-2II AR822-II AR861-3II. ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

ICE/BEVERAGE DISPENSER

Operator s Manual. Linear Asphalt Compactor. Jesse D. Doyle Isaac L. Howard, PhD Mississippi State University. January 2010 CMRC M 10-1 Version 1


OPERATOR S MANUAL. For BURLY ATTACHMENTS

7.0 Applying Basic Electricity Principles to Service Propane Appliances Skill Evaluation Packet (Updated 11/2012)

92831 TEL: (714) FAX:

Expanded Backup Control Installation & Operator s Instruction Manual

Installation, Operation and Maintenance Manual for the Potable Water System Model: PWS-01 (380 VAC Suppy x 24 VDC Controls)

OG5000 Ozone Generator Model OG5000B-A. User Manual

Manual. Industrial Air Curtain Model IF. English. Version 1.1

Installation & Maintenance Instructions. Smart Guard Ultra ZERO AIR LOSS CONDENSATE DRAIN 02/09

THERMAL SYSTEMS, INC. Installation and Operation Manual

Transcription:

Conditioning Hoppers Installation and Electrical Wiring Guide

PAGE -1 of 24 CONDITIONING HOPPER

We appreciate your business and hope you enjoy your Samuel Jackson Seed Cotton Conditioning Hopper This manual contains basic information on the installation of your Seed Cotton Conditioning Hopper. Additional information for the moist air pipe sizing, pipe routing, and fan requirements is usually supplied directly to the gin as each installation is unique. In the future when you require service, technical support, or parts please contact us by phone, fax, or the internet. Our engineers and service people are available to assist you in obtaining the best performance from your Samuel Jackson, Inc. products. Again, thanks for choosing a Samuel Jackson Seed Cotton Conditioning Hopper SAMUEL JACKSON, INCORPORATED MAIL: P.O. BOX 16587 LUBBOCK, TEXAS 79490 COURIER: 3900 UPLAND AVENUE LUBBOCK, TEXAS 79407 TELEPHONE 806-795-5218 OR 800-862-9966 TELEFAX 806-795-8240 E-Mail: engineering@samjackson.com Internet: www.samjackson.com Copyright 2004 SAMUEL JACKSON, INCORPORATED. All rights reserved. PAGE 0 of 24 CONDITIONING HOPPER

CLASSIC STYLE CONDITIONING HOPPER DIMENSIONS & PARTS Hoppers are custom made to fit into the space of the existing gin stand feeder hopper. The overall height, width and depth varies from installation to installation. A typical CLASSIC STYLE side double entry hopper is shown below. The following drawings are to be used for typical dimensions and views for Double Entry and Single Entry Hoppers. Consult factory for recommended layout for moist air piping. 14100 Humid Air Valve (One for single entry, two for double entry) Valve in open position. Note roll pin indicator position. Roll pin valve position indicator Valve in closed position. 13550 Inlet Transition 7 inch dia to 3 X 14, 12 inch overall length (One supplied for single entry, two for double entry) PAGE 1 of 24 CONDITIONING HOPPER

PAGE 2 of 24 CONDITIONING HOPPER

PAGE 3 of 24 CONDITIONING HOPPER

END ENTRY STYLE DOUBLE AIR ENTRY CONDITIONING HOPPER The End Entry Style Double Entry Conditioning Hopper is shown below. Humid air enters the valves located on the ends of the Hopper requiring only one manifold pipe to connect multiple hoppers. Consult factory for recommended layout of air piping. Hoppers are custom made to fit into the space of the existing gin stand feeder hopper. The overall height, width and depth varies from installation to installation. A drawing showing typical dimensions and the dimensions required for construction is shown on next page. 14100 Humid Air Valve with 13550 Transition PAGE 4 of 24 CONDITIONING HOPPER

PAGE 5 of 24 CONDITIONING HOPPER

PARTS FOR THE CONDITIONING HOPPERS A 13865 Plant Installation Package is included with the hopper order. It includes a 13850 or 20093 Valve Relay Panel, a 13860 Relief Plug and a 13855 Air Filter, Regulator, Lubricator Assembly. The 13850 Valve Relay Panel is used with all Samuel Jackson Humidaire Units except the HU-60-1260 oil-fired Humidaire Unit. Use the 20093 panel for the 1260 model. Refer to the section on electrical schematics for the wiring to match your model Humidaire Unit. 13850 Valve Relay Panel 20093 Valve Relay Panel (Note 5th relay required for use with the HU-60-1260 model Humidaire Unit) 13855 Air Filter, Regulator and Lubricator Assembly One Assembly supplies air to all hoppers in the system. Adjust regulator to about 80 psi pressure. PAGE 6 of 24 CONDITIONING HOPPER

INSTALLATION OF 13860 RELIEF PLUG ASSEMBLY The purpose of the Relief Plug is to allow a constant flow of air through the Humidaire Unit regardless of whether the hopper(s) are calling for air. The weights are adjusted on the plug so that no air is relieved when all hoppers are calling for air and all air is relieved when no hoppers are calling for air. On the following page is a drawing showing the typical installation of the 13860 Relief Plug. Consult the factory for more information on its installation or to the sheet metal installation drawings supplied with the piping. Removable stack weights PAGE 7 of 24 CONDITIONING HOPPER

PAGE 8 of 24 CONDITIONING HOPPER

HOOK-UP OF 14100 HUMID AIR VALVE A decal is located near the air solenoid valve to help identify the valve ports. Compressed air of 80 psi (5.5 bars) is sufficient to operate the valve. This air should come from the 13855 Filter, Regulator and Lubricator Assembly. The solenoid valve coil is always 110-120 volt, 50 or 60 HZ. Its power comes from the Humidaire Unit. Moist air butterfly valve is closed when coil is energized. EXHAUST EXH P B A AIR INLET 80 PSI (5.5 BAR) AIR VALVE & CYLINDER HOOKUP Air hook-up detail decal 14471 Air Cylinder 17185 Coil for valve 110V-50HZ, 120V-60HZ 13563 Solenoid Valve 14100 Humid Air Valve PAGE 9 of 24 CONDITIONING HOPPER

CONTROL LOGIC FOR HUMID AIR VALVES The butterfly valve in the 14100 Humid Air Valve should close the moist air flow off to the hopper when cotton is not flowing through the hopper. It is most common for the 240 VAC or 110 VAC signal to the Valve Relay Panel terminals 1,2, 3 and 4 (corresponding to each gin stand) to come from the gin stand breast in limit switch. Sometimes, the signal comes from the gin stand feeder feed works control. Terminal 9 is the common terminal for the signal input. A13850 or 20093 Relay Panel controls the action of the solenoid valves on the 14100 Humid Air Valves and the water pump run signal to the Humidaire Unit. If no hoppers are calling for cotton, the water pump run signal is off. As soon as one hopper calls for cotton, a water pump run signal is given. The solenoid valve coils on the 14100 Humid Air Valves are always 110-120 VAC. Their power comes from the Humidaire Unit. SJI Part No. 13146 Relays should be used for 120 VAC inputs. SJI Part No. 13864 Relays should be used for 240 VAC inputs. PAGE 10 of 24 CONDITIONING HOPPER

FOLLOWING IS ELECTRICAL WIRING SCHEMATIC FOR 13850 VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU-60-1455 GAS-FIRED HU-SOUTHWEST-1480 GAS-FIRED PAGE 11 of 24 CONDITIONING HOPPER

PAGE 12 of 24 CONDITIONING HOPPER

FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR 13850 VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU-60-1255 GAS-FIRED HU-60-1265 OIL-FIRED PAGE 13 of 24 CONDITIONING HOPPER

PAGE 14 of 24 CONDITIONING HOPPER

PAGE 15 of 24 CONDITIONING HOPPER

FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR 13850 VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU-60-1106C GAS-FIRED HU-60-1200 OIL-FIRED HU-60-1250 GAS-FIRED PAGE 16 of 24 CONDITIONING HOPPER

PAGE 17 of 24 CONDITIONING HOPPER

PAGE 18 of 24 CONDITIONING HOPPER

FOLLOWING ARE ELECTRICAL WIRING SCHEMATICS FOR 20093 VALVE RELAY PANEL FOR SINGLE AND DOUBLE ENTRY CONDITIONING HOPPERS USED WITH SAMUEL JACKSON HUMIDAIRE UNIT MODELS: HU-60-1260 OIL-FIRED PAGE 19 of 24 CONDITIONING HOPPER

PAGE 20 of 24 CONDITIONING HOPPER

PAGE 21 of 24 CONDITIONING HOPPER

PAGE 22 of 24 CONDITIONING HOPPER

IMPORTANT! The following notice affects your warranty. Electrical Controls and Your Safety Your new Sam Jackson product may be equipped with electrical controls, or designed to interact with controls on a related Sam Jackson product. In the event that local, state, federal or other specified safety compliance is required, we will consider modifications to meet the particular requirements. Implementation of alternative safety devices may incur additional charges. No warranty of compliance with a particular standard is made in the absence of specific reference to it in our quotation. If you modify, or permit others to modify, these controls without specific written permission from Sam Jackson, Inc. the warranty on your product will be void and there is a possibility of serious damage to machinery, damage to product, serious injury to personnel, or death. The modifier of the controls assumes all liability for these consequences. Samuel Jackson, Incorporated 3900 Upland Avenue Lubbock, Texas 79407 806-795-5218 PAGE 23 of 24 CONDITIONING HOPPER

This page intentionally blank