UCS UCS/M UCS/H UCS900

Similar documents
SIGMA PRISMA LOW BODY CONCEALED

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

FAN COIL UNITS LASER / LOW BODY / CONCEALED

PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS

Blower-YEFB-020-3R-1maxVel

YFCN Fan Coil Unit centrifugal fan

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

QTS SELECTION TECHNICAL BOOKLET

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Conditioning your ambient, maximising your comfort.

Fan Coil Range HYDRONIC TERMINALS

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Conditioning your ambient, maximising your comfort.

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

COMFORT HYDRONIC TERMINALS

a-life Hydronic terminals Fan-coil for professional applications, with cabinet or built-in version 1,50-7,50 kw <<< BACK INDEX

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

CASSETTE UNIT. Comfort Circle

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

technical data Fan coil unit FWB small duct unit

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

System architecture. Air treatment Index

MORE VALUE TO YOUR WELL-BEING

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

SIMPLICITY FULL MODULARITY?

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

Flexible & Innovative. Cooling Solutions

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

A NEW BEGINNING IN FAN COIL HISTORY

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

Elegance and design for your residential comfort

UniTrane Ductable Units D-line and B-Line

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Energy-efficient heat source provides comfort in large rooms

DC Inverter Smart VRF Products(R410A)

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

SIMPLICITY OR FULL MODULARITY?

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

LOW STATIC HYDRONIC DUCTED UNIT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

kw. technicalcatalogue

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

KPSW CONSOLE TERMINAL UNIT

next evo cw next evo cw rcgroupairconditioning

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

INDUSTRIAL AIR CURTAIN. IndAC 2

Fan coil units with centrifugal fan. Fan coils with inverter BRUSHLESS motor. Fan coil units with centrifugal fan. Units for air conditioning system

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Galletti Hydronic indoor units

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

TopVent Design Handbook

AQUASNAP JUNIOR 30RHV

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

PRODUCT GUIDE

Transcription:

EN UCS UCS/M UCS/H UCS900

EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous modulation of the air flow, constantly related to the concrete need of energy in the room. EST technology is composed by a brushless motor combined to a dedicated electronic device (inverter), managed by specific regulators developed by EURAPO. In comparison to the traditional units equipped with asynchronous three-speed-motors, the fan coil and cassette units with brushless motors can obtain a considerable energy saving, by reducing the power consumption up to 70%. 80% W Speed 1 EST 70% 60% Speed 2 50% Speed 3 40% 30% Speed 5 Speed 6 Speed 4 20% 10% 0% m 3 /h m 3 /h Speed 6 Speed 5 Speed 4 Speed 3 Speed 2 Speed 1 Asynchronous fan coil absorption (W) Energy saving with EST fancoil EST fancoil absorption (W) Thanks to the step-less modulation of the fan speeds it is possible to accurately regulate the air volume in a very precise way, in strict relation to the real need of air conditioning in the room. Oscillations in the temperature and relative humidity are reduced at lowest level: a guarantee for the highest comfort in the room. The possibility to reach very low air volumes makes the units extremely quiet at the lowest motor revolutions. EST technology is designed in particular for offices, hospitals, nursing homes and hotels. It is available for the EURAPO range of fan coil units, cassette units and ducted units. The EST technology consists of a brushless motor combined to a dedicated electronic device (inverter), managed by specific regulators. The controller uses a modulating signal with 0-10Vdc tension in order to regulate the fan speed. The brushless electric motor is composed by a rotor having permanent magnets, whose magnetic fields interact with the ones produced by the stator winding. The transfer of current is no longer by mechanical commutation (sliding contacts) but by an electronic commutation system: an electronic controller (inverter) powers the motor s stator and generates rotating magnetic fields, that determine the rotor s speed.

For applying the EST technology also to the ducted units, the inverter is provided with DIP SWITCHES that can be also set on site, during start-up of the unit. This high flexibility grants the proper configuration for every kind of installation, by personalization of the Dip Switches accordingly to the pressure drop in the system. Brushless motors develop much less heat than the traditional brushed motors and they have much lower mechanical resistance than the standard asynchronous ones. They offer several advantages, like as higher efficiency, longer lifetime, less need of maintenance. The absence of brushes eliminates also the main source of electromagnetic noise. By giving a 0-10Vdc signal to the inverter, an electronic regulator intervenes by simply managing the fan speed and the rotor s torque in a continuous way, adapting with extreme precision the air volume to the real and punctual requirements in the room. For managing all units equipped with brushless motors, EURAPO developed a new microprocessor control, available both built-in the unit (EDCL) and for remote installation on the wall (EDCR). Also the OMNIBUS digital system has been implemented in order to be combined to the EST technology: the new cards for fan coil units (OBV10) and for cassette units (OBU10) can be connected to the new OMNIBUS consoles, designed for managing fan coil and cassette units with brushless motors. The consoles are available for on-wall installation (ODC236), fitted in the fan coil unit or for built-in the wall installation, on 503 modules (ODC235 white colour and ODC245 black colour). OMNIBUS regulators give the possibility to fully control the fan speed (0-100%) and/or to manually select three fan steps (high, med and low speed): it is actually possible to set in every moment and very easily the three different levels of motor s rotation, in order to fulfil specific thermal or acoustical requirements. FEATURES 0-10Vdc control signal Low mechanical resistance and low overheating Wide range of fan speed regulation, especially at the lowest revolutions Continuous regulation of the fan speeds (0-100%) Possibility to manually set the desired three fan steps (by using OMNIBUS regulators) Available for Sphera, Sigma, Prisma, Low Body, Incasso fancoil units, UCS, UCS/M, UCS/H cassette units and CH/H, EBH and EDS ducted units ADVANTAGES Energy saving: electrical absorption reduced up to 70% Higher efficiency: possibility to adapt the air volume and the capacities accordingly to the real room loads Higher comfort: reduced oscillation of the temperature and relative humidity in the room Extremely quiet functioning of the unit, thanks to the operation at low revolutions Reduced wearing and higher reliability Longer expected lifetime of the motor

UCS UCS CASSETTE FANCOIL Cassette fancoil, for heating and cooling mode, 2 and 4 pipe systems, capacity from 1,30 kw to 4,79 kw. EURAPO has designed a Cassette fancoil called UCS, for 2 and 4 pipe systems, to satisfy all the requests of comfort and space optimization, above all in public environments, offices and shops. The UCS Cassette has been planned in accordance with quality standards that characterize the complete EURAPO production since years: the particular care to the functionality and technical reliability of all the components and the continuous research for new technological solutions, allowed to obtain optimum performances, paying also attention to the environmental welfare. Available in 6 models, the UCS overall dimensions allow an easy installation in modular false ceilings (600x600), while the hydraulic and electrical connections, located on the same side, facilitate the maintenance operations. The unit in basic configuration is equipped with a condensate pump, and it is pre-arranged for the connection to an additional air outlet duct and/or to an external air intake. The air intake/outlet grilles are designed in order to avoid that people are directly invested by the air flow (thanks to the Coanda effect), by reaching the maximum levels of comfort. The CASSETTE unit can be managed by the complete range of EURAPO regulators: from the standard electromechanical and microprocessor controls to the digital controls (OMNIBUS), compatible to BMS Systems.

UCS/M Cassette fancoil, for heating and cooling mode, for 2 and 4 pipe system, capacity from 1,30 kw to 4,79 kw. The UCS/M cassette unit is born as an aesthetical variation of the consolidated and appreciated Eurapo cassette units. The UCS/M is characterized by the micro-drilled air intake grill and its air diffusion frame entirely realized in painted metal sheet, perfectly adaptable to modular false ceilings. Similarly to the standard UCS models, the metallic grill has been designed to obtain the Coanda effect, that guarantees an uniform and pleasant air diffusion, by avoiding that people are directly invested by outgoing air flow. The UCS/M is not provided with air outlet flaps for the deviation of the air flow, therefore the air diffusion is homogeneous on all the four sides of the cassette. The micro-drilled air intake grill is perfectly integrated in the outer frame, which contains the air filter, easily accessible to make the cleaning operation extremely comfortable.

UCS UCS/H CASSETTE FANCOIL Cassette fancoil without condensate pump, for heating and cooling mode, 2 and 4 pipe systems, capacity from 1,3 kw to 4,79 kw. UCS/H cassette unit has been designed to allow a natural condensate water discharge, for gravity; in this way, condensate pump is not necessary. UCS/H unit is particularly indicated when reduced maintenance operations are required, for safety or sanitary locations (banks, police stations, hospitals, sanitary environs), or if very low sound levels are tolerated. Similarly to the standard UCS models, the grill has been designed to obtain the Coanda effect, that guarantees an uniform and pleasant air diffusion, avoiding that people are directly invested by outgoing air flow. The absence of the condensate pump allows a greater silence, reduced electric consumptions and limited maintenance operations.

UCS900 Cassette fancoil 900x900 for heating and cooling mode, 2 and 4 pipe system, capacity from 3,90 kw to 10,15 kw. With an innovative, essential and clean design, which fits in every kind of environment, the UCS900 water cassette unit is the result of the stylist research to present an innovative product in terms of performance, low sound level, comfort and regulation flexibility. The aesthetics of this unit is accurate in every detail, planned in accordance with the EURAPO experience, appreciated by architects and designers from all over the world. The UCS900 water cassette unit can be used for heating and cooling applications; it has been designed to fit into modular or not modular false ceilings, in 2 and 4 pipe systems. The 900x900mm dimension of the cassette unit permits to satisfy the cooling demand of ambient having quite big volumes. The UCS900 units in basic configuration are equipped with a condensate pump and they are pre-arranged for the connection to an additional air outlet duct and/or to an external air intake, by using the specific collars, supplied as standard in a kit. The particular shape of the air outlet plenum is designed specifically in order to obtain the Coanda effect, a phenomenon for which the air outlet flow tends to adhere to the ceiling and falls down smoothly, without blowing directly towards people in the room: the optimal solution for an uniform and pleasant air diffusion. The UCS900 cassette unit can be managed by the complete range of EURAPO regulators: from the standard electro-mechanical and microprocessor controls to the digital controls, compatible to BMS Systems.

OMNIBUS Yet designing and producing air conditioning systems comprising selected, reliable components is not sufficient in itself to guarantee high standards of air-conditioned comfort, these also need to be integrated and harmonised with the intelligence controlling them. Only complete synergy between terminal unit performance and heat regulating devices can guarantee optimum results and meet the most modern requirements in comfort management simply and efficiently. OMNIBUS The EURAPO-OMNIBUS Digital System is designed to fully regulate the water terminal units (such as fan coil units, water cassette units, high pressure ducted fan coil units and radiant systems) for domestic use, residential buildings, public rooms. This controller permits to be easily programmed by the installing company and configured accordingly to each particular type of system. Elegant design Compatible with brushless and inverter technology LCD Display Flexible configuration Touch screen Service tool available Humidity sensor MODBUS RTU: free protocol Plug & Play connections ETHERNET (TCP/IP) compatibility Weekly, daily and monthly programs LONWORKS compatibility Scenarios configuration Different access levels to the Building Management System

OTOUCH is a control and supervision system developed by Eurapo Laboratories in order to manage residential comfort. This high tech solution is matched with an easy-to-use graphical interface which has been designed in cooperation with Udine University in order to guarantee an intuitive and simply comfort control. OTOUCH can functionally fully control air conditioning system devices (such as fan coils units) or radiant systems (such as hydraulic actuators or dehumidifiers) or even both at the same time, following an innovative idea of control philosophy. Its distinctive feature consists of being able to monitorize and control all functions of fan coils units toghether with the capability of interacting and integrating different HVAC system devices in the same control panel. OTOUCH can control: Cooling and heating units (chillers/boilers) HVAC system pumps Mixing valves (for radiant systems) Thermal zone valves Dehumidifiers Fan coil units

UCS UCS/M CASSETTE FANCOIL electric box condensate discharge electric box condensate discharge 2 pipes installation 1 Water inlet 3/4 F 2 Water outlet 3/4 F 4 pipes installation 1 Cooling water inlet 3/4 F 2 Cooling water outlet 3/4 F 2 pipes installation 1 Water inlet 3/4 F 2 Water outlet 3/4 F 4 pipes installation 1 Cooling water inlet 3/4 F 2 Cooling water outlet 3/4 F 3 Heating water inlet 1/2 F 3 Heating water inlet 1/2 F 4 Heating water outlet 1/2 F UCS 4 Heating water outlet 1/2 F UCS/M Dimensions (mm) and weights for UCS Dimensions (mm) and weights for UCS/M A 615 A 615 B 312 B 312 C 575 C 575 D 70 D 70 Kg 30 Kg 33

UCS/H UCS900 electric box electric box condensate discharge condensate discharge 2 pipes installation 1 Water inlet 3/4 F 2 Water outlet 3/4 F 4 pipes installation 1 Cooling water inlet 3/4 F 2 Cooling water outlet 3/4 F 3 Heating water inlet 1/2 F 4 Heating water outlet 1/2 F 2 pipes installation 1 Water inlet 3/4 F 2 Water outlet 3/4 F 4 pipes installation 1 Cooling water inlet 3/4 F 2 Cooling water outlet 3/4 F 3 Heating water inlet 1/2 F 4 Heating water outlet 1/2 F Dimensions (mm) and weights for UCS/H A 615 B 507 C 575 D 70 Kg 39 Dimensions (mm) and weights for UCS 900 A 985 B 360 C 820 D 75 Kg 45

UCS GENERAL FEATURES CASSETTE FANCOIL The main structure is made of galvanised steel, completely insulated inside with closed cell thermal insulation material. On three of the four sides, there are prearranged holes for the connection to an air supply duct. Furthermore, there is a prearranged hole for the connection to an external air intake. The relevant collars for an easy connection to the air duct are always supplied as standard. The finned heat exchangers are made of copper pipes and surface treated aluminium fins. The surface treatment on the fins permits to have a better condensing water discharge from the fins themselves and a perfect air passage through the heat exchanger, with reduced pressure drops and a high dehumidification and efficiency of the coil. 2 and 3 row coils are available (for UCS900 only 3 row coils). Water connections have diameter ¾ G female on the cooling coil and diameter ½ G female on the heating coil (4 pipe system). The fan deck, installed in central position, is composed by a centrifugal fan and plastic impeller. The electric panel (QEC00) consists of a galvanized metal box, which contains the terminal board for the electrical connections, the earth protection terminal, the autotransformer and the capacitor. The electric panel is located on the side of the unit, at the same side of the water connections. The air filter is composed by a metal frame on which a polypropylene fibre is fixed. It can be easily removed thanks to two textile tongues fixed on its frame. The filter is immediately accessible by removing the external air intake grill. The air intake grill is realized in heat-resistant ABS plastic material*, white colour, with a very discreet design, covering the air outlet flaps. This particular combination of air intake and air outlet grilles avoids having direct air flow against the people in the room. A perfect internal insulation with closed-cell insulating material guarantees not to have problems of water condensation on the grilles. The air outlet plenum is made by heat-resistant ABS plastic material* in white colour. It permits to distribute the air on the 4 sides of the unit. On each side of the cassette unit there are white flaps which can be totally closed on one or two (max.) sides of the unit, particularly used in case of an air discharge into an adjacent room. The air intake grill is fixed by pressing the pins on the four angles into the air supply plenum: this very easy operation of fixing and removing the grill facilitates all installation and maintenance operations. UCS EURAPO Cassette units (except UCS/H) are supplied with a built-in condensate pump having a no-return valve on the outlet. The pump is activated by a floating switch and a second switch is used for closing the cooling valve in case of too high water level in the condensate tray, due to some problems in the water evacuation system. * For UCS/M model, the micro-drilled intake grill and the diffusion frame are made in painted metal sheet.

ACCESSORIES KREL Electric heater Stainless steel 1,5 kw or 3 kw (UCS900) electric heater supplied with 2 safety thermostats, one with automatic resetting and the other one with manual resetting and a power relay card (QEC20). When the electric heater is installed, the cassette unit is internally insulated with heat resistant insulating material. Valves and shut-off valves 3 way factory fitted valves, 230V or 24V, ON/OFF or modulating type. Shut-off valves and relevant hydraulic kit together with the auxiliary condensate drain pan are supplied loose. GAM Bigger grill Grills with bigger frame dimensions (680x680 mm). When it is necessary to cover a bigger opening on the false-ceiling. EXTRA RAL Special painting colour of the grill, available in all RAL range. CONTROLS CMR00 Remote room temperature thermostat, suitable for the selection of the main functions of the unit: type of ventilation, fan speed selection, Summer/Winter switch and room temperature control. EDCR Remote microprocessor control, for on wall installation, designed for water terminal units equipped with Brushless motors (EST Inverter Technology). It permits to control the type of ventilation, the fan speeds, Summer/Winter switch and room temperature thermostat. ONU11 OC514 Omnibus card + Infrared receiver Infrared receiver built-in the suction grill. It is possible to regulate the Cassette unit through the remote control (OIR30). OIR30 Infrared remote control LCD display for the visualisation of the main working parameters. Buttons for setting the main working parameters (Fan speed, Fan mode, Setpoint, etc.). OC736 Analogue Plus Console Elegant and simple console for the setting of the temperature set point, the functioning of the fancoil unit, the S/W changeover and the speed selection. Compatible with the Supervision System. OC236 Console Display An elegant device that permits to set all working parameters (set point, speed, status, etc.). It can also be used as diagnosis instrument, thanks to the parameters visualisation and modification. Compatible with the Supervision System.

TECHNICAL DATA UCS, UCS/M, UCS/H TECHNICAL DATA (max speed - EST) 2 pipes 4 pipes CASSETTE FANCOIL Cooling Air temperature 27 C d.b., 19 C w.b. Water temperature 7/12 C Heating 2 pipes Air temperature 20 C Inlet water temperature 50 C Heating Air temperature 20 C Water temperature 70/60 C Further data 221 232 421 432 Total cooling capacity [kw] 2,75 4,96 1,96 4,01 Sensible cooling capacity [kw] 2,12 3,73 1,76 3,35 Water flow [l/h] 472 851 336 688 Pressure drop [kpa] 9,80 21,20 8,80 28,00 Heating capacity [kw] 3,55 5,74 Water flow [l/h] Values as Cooling, accordingly to the EUROVENT Standards and UNI ENV 1397 Norm Pressure drop [kpa] 8,50 19,10 Heating capacity [kw] 6,04 9,61 2,21 3,96 Water flow [[l/h] 531 844 194 348 Pressure drop [kpa] 10,20 18,20 7,20 27,00 Air flow [m 3 /h] 702 840 702 840 Sound power level [db(a)] 57 60 57 60 Sound pressure level [db(a)] (1) 47 51 47 51 Power input [W] (2) 40 63 40 63 Absorbed current [A] (2) 0,37 0,55 0,37 0,55 Water content [l] 1,34 2,12 1,34 2,12 (0,3) (3) (0,3) (3) TECHNICAL DATA (max speed - asynchronous) 2 pipes 4 pipes Cooling Air temperature 27 C b.s., 19 C w.b. Water temperature 7/12 C Heating 2 pipes Air temperature 20 C Inlet water temperature 50 C Heating Air temperature 20 C Water temperature 70/60 C Further data 221 231 232 421 431 432 Total cooling capacity [kw] 2,52 3,57 4,79 1,60 2,93 3,86 Sensible cooling capacity [kw] 1,94 2,80 3,57 1,50 2,39 3,26 Water flow [l/h] 432 613 822 275 503 662 Pressure drop[kpa] 8,10 10,40 20,10 14,30 16,60 26,10 Heating capacity [kw] 3,28 4,17 5,50 Water flow [l/h] Valori uguali a Raffreddamento, come da specifiche EUROVENT e norme UNI ENV 1397 Pressure drop [kpa] 6,80 8,10 18,20 Heating capacity [kw] 5,83 7,14 9,44 2,63 3,13 3,83 Water flow [[l/h] 512 627 829 231 275 336 Pressure drop [kpa] 8,90 8,10 17,80 10,20 16,90 25,50 Air flow [m 3 /h] 565 565 770 565 565 770 Sound power level [db(a)] 51 51 59 54 53 61 Sound pressure level [db(a)] (1) 41 41 49 44 43 51 Power input [W] (2) 53 52 90 53 52 79 Absorbed current [A] (2) 0,25 0,24 0,43 0,25 0,24 0,38 Water content [l] 1,34 2,12 2,12 1,34 2,12 2,12 (0,3) (3) (0,3) (3) (0,3) (3) (1) Sound pressure level in a 100 m 3 room, 1.5 m distance and reverberating time of 0.3 s. (2) Electrical supply: 230-1-50 [V-ph-Hz]. (3) Additional row. Eurapo take part in EUROVENT certification program. Above mentioned models are in the FC section of the website. For conditions different from standard ones, please use the selection software or contact EURAPO staff. The printed data could be modified without any notice.

TECHNICAL DATA UCS900 TECHNICAL DATA (max speed - EST) 2 pipes 4 pipes Cooling Air temperature 27 C b.s., 19 C w.b. Water temperature 7/12 C Heating 2 pipes Air temperature 20 C Inlet water temperature 50 C Heating Air temperature 20 C Water temperature 70/60 C Further data 922 942 Total cooling capacity[kw] 10,37 9,40 Sensible cooling capacity [kw] 7,59 7,10 Water flow [l/h] 1779 1613 Pressure drop [kpa] 26,10 33,00 Heating capacity[kw] 12,82 Water flow [l/h] Values as Cooling, accordingly to the EUROVENT Standards and UNI ENV 1397 Norm Pressure drop [kpa] 24,20 Heating capacity [kw] 21,61 8,65 Water flow [ [l/h] 1898 760 Pressure drop [kpa] 26,00 39,40 Air flow [m 3 /h] 1550 1550 Sound power level [db(a)] 60 60 Sound pressure level [db(a)] (1) 50 50 Power input [W] (2) 119 119 Absorbed current [A] (2) 0,94 0,94 Water content [l] 4,22 4,26 (0,6) (3) TECHNICAL DATA (max speed - asynchronous) 2 pipes 4 pipes Cooling Air temperature 27 C b.s., 19 C w.b. Water temperature 7/12 C Heating 2 pipes Air temperature 20 C Inlet water temperature 50 C Heating Air temperature 20 C Water temperature 70/60 C Further data 921 922 941 942 Total cooling capacity [kw] 8,76 10,15 7,62 9,20 Sensible cooling capacity [kw] 6,81 7,80 6,11 7,62 Water flow [l/h] 1507 1853 1460 1781 Pressure drop [kpa] 18,0 26,0 23,2 32,0 Heating capacity [kw] 10,43 11,74 Water flow [l/h] Values as Cooling, accordingly to the EUROVENT Standards and UNI ENV 1397 Norm Pressure drop [kpa] 19,3 22,0 Heating capacity [kw] 18,40 23,16 7,53 8,86 Water flow [[l/h] 1608 2025 658 774 Pressure drop [kpa] 16,1 24,3 19,0 40,9 Air flow [m 3 /h] 1270 1670 1270 1670 Sound power level [db(a)] 54 61 54 63 Sound pressure level [db(a)] (1) 45 52 45 53 Power input [W] (2) 130 164 130 164 Absorbed current [A] (2) 0,59 0,72 0,59 0,72 Water content [l] 4,22 4,22 4,26 4,26 (0,6) (3) (0,6) (3) (1) Sound pressure level in a 100 m 3 room, 1.5 m distance and reverberating time of 0.3 s. (2) Electrical supply: 230-1-50 [V-ph-Hz]. (3) Additional row. Eurapo take part in EUROVENT certification program. Above mentioned models are in the FC section of the website. For conditions different from standard ones, please use the selection software or contact EURAPO staff. The printed data could be modified without any notice.

Eurapo Srl Via A. Malignani, 12 33170 Pordenone - Italy T +39 0434 572552 F +39 0434 28667 info@eurapo.it www.eurapo.it www.eurovent-certification.com www.certiflash.com 6DC0202 - EN1400