OPERATION & MAINTENANACE MANUAL

Similar documents
Instruction Manual. Pharma-X ESE02197-EN Original manual

Instruction Manual. Pharma-line ESE02198-EN Original manual

WFIS. Water For Injection Stills

PHARMACEUTICAL INDUSTRY CLEANING SYSTEMS

Chapter-8 Capacity Control of Refrigeration Systems

GMP compliant cleaning in the Pharmaceutical Industry. Andreas Trochsler 06. November 2012

VS LD series vertical steam sterilizers

FT900S FLIGHT-TYPE DISHWASHER

Design Benefits and Advantages:

Titanium Plate Heat Exchanger. Installation & Operating Manual

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Tetra Pak Pasteurizer D Efficient pasteurization for dairy applications

This series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.

Beverage Processing System

Daikin Water Cooling, Heating, and High Capacity Booster Coils

providing the perfect mix

FT900BD FLIGHT-TYPE DISHWASHER

High Capacity Instantaneous Steam Fired Water Heater

BASIL 6000 TUNNEL CAGE WASHER

FT900 FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

Water Piping and Pumps

1020 Industrial Drive, Orlinda, TN fax

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

CL64T INDUSTRIAL TOTE WASHER

Main Office: ft x 52 ft 6 Unit Portable

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

HAMO T-420 PHARMACEUTICAL GRADE WASHER SIEMENS PC CONTROL

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

The DWC-Series - Drum Washer / Crusher Unit

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Centrifugal and Positive Displacement Pumps for Hygienic Applications

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

Installation of Glass Lined Equipment

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Vapor thermocompressor. Stills

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

INSTALLATION & MAINTENANCE MANUAL CSXT INSTANTANEOUS STEAM WATER HEATER Copyright 2006 PVI Industries, LLC

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

user s manual VUBMG102

Nexus FS Filtration Installation Guide. September 19, 2011

NQ Series Portable Chillers

Sterilizer Model LS2020 Series Beta Star Life Science Products of R-V Industries

FREEZE DRYER SMH RANGE The production freeze dryers for Pharmaceutical and Biotechnology industries

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

Owner s Manual. Keep with machine for reference CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

Electro-Sentry. Users Manual

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

Model GW1020 Laboratory Glassware Washer General Specifications

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

PACKAGED AIR COOLED Product Data Catalog

Installation, Operation and Maintenance Instructions for PlantPac Steam Plate Heat Exchanger Package

CONTROL PANEL OPERATING MANUAL AIR-COOLED SCREW CHILLER MICROTECH III CONTROLLER D EOMAC00A10-12EN

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

"ER" Series Electric Humidifier

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations

C44A/C44AW DISHWASHER

MicroTech Series 200 Centrifugal Chiller

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

SPECIFICATIONS GIRTON TUNNEL WASHER MODEL CT

rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning ORIGINAL FILE

Air Cooled Scroll Chiller / Heat Pump

VISY-X. Technical Documentation. VISY-SoftView V 1.7 User Guide for VISY-Command GUI and VISY-View Touch. Edition: Version: 6 Art.

Altanium Temperature Controllers

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Brazed Plate Heat Exchanger Operations Manual

Clean-Out-of-Place (COP) Parts Washer

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Transmission Cooling System J Operation Manual. TRANSFLOW Transmission Cooling System Service Tool J

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

AccuBrine automated brine maker Technical Specifications

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

GIRTON TREE, TUB, AND CART WASHER MODEL 80-O

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Standard Features. Performance/Capacities

SPECIFICATIONS GIRTON PALLET WASHER MODEL CW10PS

GIRTON CABINET WASHER MODEL 794A

MEDICAL DEVICES SECTOR MANUAL FOR THE TECHNICIAN. Language: ENGLISH Cod: 9046 STEAM STERILIZER SERENA THE NEW GENERATION

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

OACS Outdoor Air-Cooled Central Chillers

PHoenix-M (Mini) PORTABLE LUBE AND HYDRAULICS OIL PURIFIER OWNER/OPERATIONS MANUAL

HWD-2110 Hot Water Dispenser

Spartan Peripheral Devices. TE 256S Thermostat Applications

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Installation, Operation & Maintenance Manual. Wash System

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

1.1 This section applies to air handling units for HVAC Systems.

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1

Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual

Series 1140 and 1141 Temperature Regulators

The Book of AERMEC NRL Sequence of Operation

Service Step by Step Trouble-Shooting Check-List

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

PRESSURE WASHING SYSTEM

Transcription:

OPERATION & MAINTENANACE MANUAL Client Name Vendor Name Capacity Document Name Document No. Bayer Hydropure Systems & Exergy LLC Point of Use Cooler 5 GPM Operation & Maintenance Manual HPS-PR247-O&M-001 Total No. of Pages 13 0 26-09-2014 First Submission Rev No. Issue Date Description Remarks

Issue Date 09/26/14 Page 2 of 13 TABLE OF CONTENTS 1.0 Safety and Design... 3 1.1 Safety Precautions... 3 1.2 Recycling Information... 3 1.3 Application... 3 1.4 Design... 4 2.0 Installation and Initial Start-Up... 5 2.1 Installation Recommendations... 5 2.2 The Pressure Drop Arrangement... 7 2.3 Initial Start-Up Procedure... 7 3.0 Operation... 8 3.1 Stand-By Mode... 8 3.2 Cooling Mode... 8 3.3 Use of HMI Touchscreen... 8 3.4 Shut Down..... 13 4.0 Maintenance... 13 4.1 Cleaning of the Service Side... 13 4.2 Steam-In-Place (SIP)... 13 4.3 Gaskets... 13 4.4 Spare Part List...... 13 The information contained in this manual is for reference only and is subject to changes, if any, without prior notice.

Issue Date 09/26/14 Page 3 of 13 1.0 Safety and Design 1.1 Safety Precaution Installation - Before initial start-up, always read the initial start-up and installation section (See chapter 2 Installation and Initial Start-Up) Operation - Before Operating the equipment always read the operation section thoroughly (See chapter 3 Operation) Transportation - Always ensure that the unit is rigidly secured during transportation 1.2 Recycling Information Packing - Packing material consist of wood, plastics, metal - Wood can be reused, recycled or used for energy recovery - Plastics should be recycled or burned at a licensed waste incineration plant - Metal should be sent for material recycling Maintenance - All metal parts should be sent for material recycling - All non-metal parts must be taken care of in agreement with local regulations Scrapping - At end of use, the equipment shall be recycled according to relevant, local regulations. Beside the equipment itself, any hazardous residues from the process liquid must be considered and dealt with in a proper manner. When in doubt, or in the absence of local regulations, please contact Hydropure / Exergy. 1.3 Application The POU Cooler is a compact point-of-use cooler for Water for Injection (WFI) or Purified Water (PW) systems. The POU Cooler is intended for points of use where water is drawn intermittently. The POU Cooler incorporates heat exchangers and is used in water systems in the Pharmaceutical industry, to cool WFI or Purified water from temperature of 65 Deg. C to 30 Deg. C at a maximum flow rate of 5 GPM. The module is easy to install, operate and maintain. Systems are self-contained, shipped fully tested, passivated and ready for installation.

Issue Date 09/26/14 Page 4 of 13 Tube Side Shell Side Fluid WFI Water Chilled Water Flow Rate 5 GPM 8.6 GPM Operating Temp. In / Out 65 deg C / 30 deg C 42 deg f / approx. 88 deg f Connection Butt weld Surface Finish Wetted surfaces 0.5 µm Ra (20 µim Ra) Weight of Module Panel -02 = 145 kgs and Panel-01 = 37 kgs 1.4 Design The POU Cooler incorporates Exergy shell and tube heat exchangers to provide the optimal thermal efficiency. The double tubesheet construction eliminates the risk of any contamination between the cooling media and the WFI/PW. It is completely drainable on the product side to eliminate product holdup. The POU Cooler is built as a plug-and-play module for easy installation. It is delivered complete with insulation, valves, PLC and HMI (Human Machine Interface.). A throttle valve arrangement for installation on the WFI/PW main loop may be supplied as optional. The POU Cooler is fully drainable on the product side with no dead legs. All product wetted surfaces have a surface finish less than 0.5 Ra µm (20 Ra µin). The POU system can be operated in AUTO MODE or MANUAL MODE. While in MANUAL MODE, all automatic valves can be operated individually. AUTO MODE has two operating modes: Stand-By Mode The POU system can be regarded as a sub-loop of the main loop. To maintain sanitization while the system is not in use, hot water from the main loop enters and flows continuously through the point of use cooler (Panel-2 and Panel-1) and back to the main loop. The manual diaphragm valve (DV-02) on the main header provides a pressure drop across the header to divert the required amount of flow through the POU system.. Cooling Mode When selected, chilled water flow begins, and the heat exchangers start to cool down. Within seconds, once the dispensing temperature is achieved, the dispensing valve will open providing temperature controlled WFI/PW at the outlet connection. It is also possible to withdraw hot WFI at the point of use in MANUAL MODE.

Issue Date 09/26/14 Page 5 of 13 2.0 Installation and Initial Start-Up 2.1 Installation Recommendations Do not install the heat exchanger under conditions that exceed the specified design conditions. On the POU module Panel-02 connect the hot water inlet (N6), hot water outlet (N7), chilled water inlet (N1), chilled water outlet (N2), instrument air inlet (01), electrical supply 120V inlet (04), 24V DC outlet (05), HMI out (06), instrument air out (02) to AZDV-03, and instrument air out (03) to AV-01. Recommended pressure of instrument air is 80 psi (6 bar). PANEL-02

Issue Date 09/26/14 Page 6 of 13 On the POU module Panel-01 connect the hot water inlet (N8) from Panel-02, hot water outlet (N9)(return to header) and connect 24VDC in (03), HMI interface connection (04) as well as instrument air supply in (01) for valve AZDV-03 and instrument air supply in (02) for valve AV-01; all coming from Panel-02. PANEL-01 - A counter-current flow through the heat exchangers gives the most efficient heat transfer, such that the incoming cooling water with low temperature, imparts maximum cooling effect to exiting WFI/PW. - If the POU System is installed at a low point, it can be used as a draining point of water system. - To ensure it is drainable, it is recommended to install the POU system in a vertical position. If installed in a horizontal position the POU module is no longer drainable. Important: The double use point POU cooler module is to be installed through the wall. The single use point POU cooler module is to be installed on the wall. The installation should be strong enough to bear the load of the POU cooler modules. Read the drawings and check the distance from the wall, to make sure that there is proper alignment with the main loop pipe of the WFI/PW system.

Issue Date 09/26/14 Page 7 of 13 2.2 The Pressure Drop Arrangement In standby mode, hot water from the main loop enters through Panel-02 and flows continuously through the POU cooler modules and returns from Panel-01 back to the main loop, due to the pressure drop created across the diaphragm valve DV-02, which is to be installed on the header across inlet and outlet connections of WFI /PW. The direction of flow should be as indicated by the arrows in the diagram below. Pressure Drop Arrangement 2.3 Initial Start-Up Procedure Upon initial start-up, with the system in MANUAL MODE, slowly start to circulate the chilled water only. Make sure that the entire cold side of the system is completely flooded. The WFI/PW should then be gradually introduced until the entire hot side of the system is completely flooded.

Issue Date 09/26/14 Page 8 of 13 3.0 Operation 3.1 Stand-By Mode When the heat exchanger is in stand-by mode the manual diaphragm valve DV-02 is slightly throttled, to create small Pressure drop in the WFI/PW main loop, across the inlet and outlet of the modules. Hot water from the main loop enters and flows continuously through both the modules, Panel-02 and Panel-01, and back to the main loop. The normally open recirculation valve AV-01 is open and normally closed chilled water inlet valve AV-02 is closed. The dispensing valves AZDV-01, AZDV-02 and AZDV-03 are in closed position. A sufficient flow is maintained in the POU System by means of throttling the diaphragm valve DV-02 and creating the pressure drop in the main loop, as long as the flow rate in the main loop is maintained. 3.2 Cooling Mode In cooling mode, the normally open recirculation valve AV-01 is closed and the normally closed chilled water inlet valve AV-02 is open. Cold WFI/PW can be drawn from any one of the dispensing valves AZDV -01, AZDV-02 & AZDV-03 by selecting the required user point from its respective HMI screen. Only one dispensing valve may be used at a time. Once selecting the cooling mode on the HMI screen, it will take a few seconds for the dispensed water to begin flowing. Hot water may be dispensed using the MANUAL MODE.

Issue Date 09/26/14 Page 9 of 13 3.3 Use of HMI Touchscreen After switching the power on, all HMI screens will display the Main screen as below. In order to access the user point, the user has to login with an appropriate user name and password, by pressing the login (key) icon on the HMI screen. The user name and passwords (common for all 3 HMI screens) are below: USER NAME PASSWORDS operator 1234 supervisor 12345 manager 55555 Press the enter arrow on the screen after entering the username user name and password.

Issue Date 09/26/14 Page 10 of 13 After successful login the user is required to press the home icon on the screen. The screen will then display as below. Then the user can then select AUTO MODE or MANUAL MODE. The normal mode of operation is AUTO MODE. MANUAL MODE is used for maintenance or for individual manual operation of each valve. Pressing the MAIN button on screen will return the menu to home screen. Pressing the ALARM button on screen will open the ALARM screen showing ALARM history. The screen will display as below.

Issue Date 09/26/14 Page 11 of 13 Pressing AUTO MODE will display the screen shown below. The POU cooler will be in Stand-by Mode. The hot WFI/PW water will enter the Panel-02 and exit through Panel-01, back to the main header. All user points and the chilled water inlet valve will be closed. To dispense cooled WFI/PW, the user will press the red button icon on the screen, next to the dispense valve controlled by that HMI (ADZV01, 02 or 03). Pressing the button again closes the dispense valve and returns the system to Stand-by Mode. If the dispense valve button is pressed while another use point is being used, an alert message will appear on the screen and water will not be dispensed.

Issue Date 09/26/14 Page 12 of 13 Pressing MANUAL MODE will display the screen shown below. In this mode, the user can change the open/closed state of each automatic valve by pressing the red button icon to dispense hot WFI/PW. next to the valve on the system diagram. This mode can also be used For setting the required parameters, the user has to press the SET PARA button on AUTO MODE screen. The screen will display as below. For description of parameters, please refer the interlock list.

Issue Date 09/26/14 Page 13 of 13 3.4 Shut Down If the system is to be completely shut down for a long period of time: Drain all fluids from the product water side of heat exchanger. Water must be drained from tubes where there is a possibility of freezing. It is preferable to flush and fill the chilled water side with plain water or RO permeate water. 4.0 Maintenance 4.1 Cleaning of the Service (Cooling Medium) Side Provide convenient means for frequently cleaning of the heat exchanger as suggested below: 1. Circulate chloride free cleaning solution through the service side at good velocity to remove sludge or other soft deposits. 2. Some soft deposits may be removed by circulating hot fresh water through the service side. 4.2 Steam-In-Place (SIP) The POU system shall be in manual mode during a steam-in-place process, with the drain point, all user points (AZDV01,02 & 03), and the header return valve (AV-01) open. The chilled water valve (AV-02) shall be closed. Steam traps must be installed at the user points and drain point. To avoid pressure build up above design conditions, it is very important that the service side (cooling medium side) is equipped with suitable safety valves or burst discs. When the SIP operation is completed, remove condensate from the lowest drain points of the system. Make sure the product side is drained properly. Close the user points and drain point and allow the system to cool. 4.3 Gaskets It is recommended that when a heat exchanger is disconnected, it should be reconnected using new gaskets. 4.4 Spare Part List Gaskets for 0.75 Tri Clamp Diaphragm for Manual Block Valve Diaphragm for Auto Diaphragm Valve Diaphragm for Auto Zero Dead leg valves Actuator for Auto Diaphragm Valves Actuator for Zero Dead Leg Valves Solenoid Coils for Auto Valves