Owner s Manual. 5 year parts limited warranty. See inside for details

Similar documents
Owner s manual. Free 5 year guarantee Register your guarantee at

Owner s manual. Free 5 year guarantee Register your guarantee at

HAZEL OWNER S MANUAL INSTALLATION GUIDE WARRANTY

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

O w n e r s M a n u a l

OWNER S GUIDE. Electrolux Precision. Steam

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Owner s Guide. Thank you for purchasing your new Eureka vacuum! Important instructions.

O w n e r s M a n u a l

WASH FILTER REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. click. click. click. months

WASH FILTER REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. Wash filter with cold water at least every month.

OWNE R S MA N UA L. Made in USA. September 2015

20 INCH ELECTRIC GRIDDLE

EclipseDryer Guide. Effective 10/09

20 High Velocity Fan with 135 Tilt Head

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Wand Cleaning Adjusting the Suction Power for Tool Cleaning Cleaning Tools... 11

(The chances are you re never going to read me) Owner s Manual.

60In. Ceiling Fan. Owner s Manual

Ui REFRIGERATOR SPEC SHEET

User s Manual & Operating Instructions

Owner s Manual for the Cordless Backpack

microcut sheet capacity user manual 7.8 gal. basket commercial shredder GMC225Pi PLATINUM SERIES

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

REGISTER YOUR DYSON 2 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

2-in-1 Corded Stick Vacuum Cleaner

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

INSTALLATION & OPERATING INSTRUCTIONS

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

e Bath Fan with Light User s Guide

TRADITIONAL CONCEPT INSTRUCTION MANUAL WARRANTY CERTIFICATE

1month WASH FILTERS REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY A B. Wash filters with cold water at least every month.

e Bath Fan with Light User s Guide

aquamanta the experts in aquatic technology

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Operating Manual HD01

(The chances are you re never going to read me) Owner s Manual. Model S10E.

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

User Manual. 40 Tower Fan MODEL: WFTR40W

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

1.5 L Electric Kettle

3months WASH FILTER REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. click click 6. click

Ultra Lightweight Household & Commercial Vacuums

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

CLEANVIEW BAGGED. Vacuum USER GUIDE SERIES

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

READ AND SAVE THESE INSTRUCTIONS

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Register your purchase. Keep this inforrnation. For Electrolux service

POWERFORCE COMPACT USER GUIDE 2112 SERIES

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

breeze easytm model # F100-1W

PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE.

48 TAYLOR CEILING FAN

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

(The chances are you re never going to read me) Owner s Manual

RETRACTOR TOTAL SYSTEM VAC

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

R Series B & T2 Model

INSTALLATION AND OPERATING MANUAL

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

Contents. Getting Started. Operation. Maintenance and Care. Problem Solving Guide. Warranty 13

M Series Fan Filter Units

User Manual. Juice Extractor MODEL: WJE2BSLA

e Heater/Exhaust Fan/Light User s Guide

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

R10S, R10D, R10P & R10SAND. Owner s Manual

HANDHELD STEAM SCRUBBER S3401 OWNER S GUIDE

Owner s Manual LIMITED WARRANTY INFORMATION OBTAINING WARRANTY SERVICE FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS REGISTRATION

English. Your Model Number is: HD1500 IMPORTANT

THE LIBERTY CEILING FAN INSTALLATION INSTRUCTIONS

Outdoor Refrigerator USER S MANUAL

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

FLCH4R Garage and Utility Electric Heater

SUTTON 52 CEILING FAN

Here is what comes in your box:

20In. Oscillating Wall-Mount Fan. Owner s Manual

Description of the vacuum R30D, R30P & R30PET. Owner s Manual

OPERATING INSTRUCTIONS

EXPANDABLE 0.5W LED FRESHWATER LIGHT FIXTURES

A2Z Ozone, Inc. PRODUCT MANUAL

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Pet Hair Eraser CORDED HAND VACUUM

Bennett Collection. Installation Manual. Model: Matte Black Brushed Nickel Fan weight ±2 lbs: 23.8 lbs (10.8 kg)

READ AND SAVE THESE INSTRUCTIONS

REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY MAX

The Monaco Patio. Please read and save these instructions

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Introduction. Features. Benefits. Records

Owner s Manual. For the Fuller Brush PORTABLE CANISTER Vacuum. Model FB-GIM

THE BRISTOL CEILING FAN INSTALLATION INSTRUCTIONS

Bathroom Exhaust Fan

Transcription:

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Owner s Manual Page 1 5 year parts limited warranty See inside for details

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 2 1 Thank you for buying the. READ AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Dyson Airblade TM Excel Xlerator World DXA5 Bobrick Cub Why Dyson developed the Airblade TM hand dryer Paper towels have always been expensive, labor-intensive, and bad for the environment. Conventional hand dryers are more economical, but are notoriously frustrating to use. Finally, a hand dryer that works properly. The Dyson Airblade TM was engineered to be the fastest, most hygienic hand dryer available. It is also energy-efficient and cost-effective to run. Fastest dry The Airblade TM hand dryer dries hands differently. It uses a high velocity blade of air to literally wipe water from hands, leaving them completely dry in just 12 seconds. 12 seconds 22.5 seconds 27.5 seconds 48 seconds 0 5 10 15 20 25 30 35 40 45 50 Time (seconds) to perception dry (0.1 grams moisture) Excel Xlerator is the registered trademark of Excel Dryer, Inc. World DXA5 is the trademark of World Dryer Corporation Bobrick Cub is the trademark of Bobrick Washroom Equipment, Inc.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 3 Cost-effective Paper towels are very expensive to procure, stock, and dispose of. Conventional hand dryers consume large amounts of electricity. The Airblade TM hand dryer, with a combination of high reliability, low maintenance, and energy efficiency, offers considerable cost savings throughout its lifetime. It uses up to 80% less energy than conventional hand dryers, so running costs are considerably lower. When compared to paper towels, the Airblade TM hand dryer offers operating cost savings of nearly 98%. Dyson Airblade TM $26.03 Paper towels $1200 Operating costs based on 200 dries/day and 300 days/year. Paper towel costs based on $0.01/towel and 2 towels/dry. They do not include any labor and costs associated with dispensing and disposing of paper. Dyson Airblade TM costs are based on $0.09/kWh and 12 seconds dry time. Uses up to 80% less energy Conventional hand dryers rely on inefficient motor technology and high power heating elements to dry hands, often taking over 30 seconds and wasting energy. The Airblade TM hand dryer is powered by the energy efficient 1400w Dyson Digital Motor, has no heating element, and takes only 12 seconds to dry hands. As a result, the Airblade TM hand dryer uses up to 80% less energy per drying cycle. The most hygienic hand dryer The Dyson Airblade TM uses a HEPA filter to remove over 99.9% of bacteria from the air used to dry hands and has antimicrobial coatings integrated into its surfaces. Only the Airblade TM hand dryer does all this. How to use The Airblade TM hand dryer generates a high velocity blade of air that wipes hands dry. 1. Insert your hands and the Airblade TM hand dryer will start automatically. 2. Withdraw your hands slowly upwards through the air to dry hands thoroughly in 12 seconds. 2

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 4 Contents 3 4 Glossary of Terms Contents of Box 5 Installation Procedures Positioning 6 Removing the Fascia Cover 7 Mounting Bracket and Unit 8 Connecting to Electrical Supply Refitting Front Fascia & Access Panel 9 Final Inspection Cleaning and Maintenance Advice 10 Troubleshooting 11-13 Limited Warranty Information Contacting Dyson READ AND SAVE THESE INSTRUCTIONS Important Safety Information General note The instructions contained within the Owner s Manual must be read carefully before attempting to install the Airblade TM hand dryer. Read and retain for future reference. Failure to accurately follow the instructions may result in the incorrect operation of the Airblade TM hand dryer, damage to property and/or personal injury. Dyson will not be held liable for any damage to property or personal injury as a result of failure to comply with the instructions contained herein. Important Safety Information Read before proceeding further CAUTION: Risk of electric shock when opening aluminium case. Do not remove casing unless this unit is being serviced by a qualified service personnel. The internal components of the Airblade TM may result in electric shock to the user if the casing is removed and handled improperly. Please consult the Dyson Airblade TM Service Manual for proper servicing and care of unit. WARNING: To reduce the risk of fire or electric shock, do not expose the internal mechanism of this unit to rain or moisture. All electrical installation and repair work must be conducted and carried out in accordance with all federal, state and local codes and regulations. The Airblade TM hand dryer must be grounded. Disconnect power before installation or servicing. Dyson recommends the use of protective clothing, eyewear and materials as necessary. Check that the electrical supply will correspond with the rating on the rating plate located on the lower left side of the unit. Trouble free operation and safety can only be continued by using genuine Dyson spare parts. Do not use Airblade TM hand dryer for anything other than drying hands. WARNING This product may contain substances known to the state of California to cause cancer, birth defects and other reproductive harm. Wash hands after handling.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 5 Glossary of Terms Sensors x 4 Air slots Rating plate Access panel Air inlet Front fascia Dyson Digital Motor HEPA filter Contents of Box Information pack containing: Owner s Manual including warranty information Registration information and reply envelope Mounting Template Tamper proof service tool Mounting bracket To install the Airblade TM hand dryer you will need: Electric drill #2 Phillips screwdriver Level Tamper proof service tool (supplied with unit) (6)-Toggle or masonry bolts and appropriate fittings (Recommended minimum size of 1/4 ) Electrical requirements: 120 volt, 60 Hz, AC-only, 15 amp minimum fused electrical supply We recommend: A separate circuit A time delay fuse or circuit breaker Note:. Please contact a qualified electrician so that the installation conforms to all federal, state and local codes and regulations. If you have any questions on the installation please call our Dyson Helpline toll free at 1-888-DYSON-AB 4

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 6 Installation Procedures 5 WARNING: Before beginning any installation work you must confirm the following: Make sure that the electrical supply has been disconnected or switched off before attempting installation to avoid the risk of electrical shock or electrocution. Ensure no pipe work (gas, water, air) or electrical cables, wires or ductwork are located directly behind the drilling area. It is recommended that at least two of the six mounting anchors for the unit be fastened into a wall stud or support. Positioning Position the mounting template provided on the wall where the Airblade TM hand dryer is to be situated. Recommended heights are shown in Fig 1 but height may need to be adjusted for each individual installation. Fig 1 Adult: 39 Men s adult 36 Women s adult Child/Wheelchair user: 32 Electrical supply connection Floor 29½ 2 Mark the 6 mounting holes for mounting the unit, and the 7th for the electrical entrance. Ensure that the electrical cable is of sufficient length to make the necessary connection to the backplate and that the wires are an additional 24 in length to reach the terminal block.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 7 Installation Procedures Removing the Fascia Cover WARNING: Metal casing may have sharp edges. Use caution in removing all screws as not to strip them. Place the Airblade TM hand dryer face up on a dry and clean work surface to protect the product and the property from damage. Remove the (5) tamper proof screws from the unit in the sequence illustrated in Figs 2 4 with the provided tamper proof service tool. Fig 2 - Remove the tamper proof screw from location A at the bottom left side Access panel and remove. Fig 3 Remove the tamper proof screw on the bottom left and bottom right sides as illustrated at B and C. Fig 4 Remove the (2) tamper proof screws from the inner section of the fascia panel at location D and E. Fig 5 Grab the fascia panel near the bottom and lift upward, tilting the panel up until it unclips from the lip. Fig 2 Fig 4 Fig 5 D 2 1 A E Fig 3 C B 6

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 8 Installation Procedures Mounting Bracket and Unit 7 Ensure that marks are level and in the correct location, then drill holes for the mounting bracket. Securely fasten the mounting bracket to the wall. Hang the unit on the secured mounting plate according to Fig 6 and then fasten the unit to the wall through the 4 holes in the lower section of the unit illustrated in Fig 7. Drill the four remaining holes that will be used to anchor the Airblade TM hand dryer to the wall as highlighted in Fig 7. Fig 6 Fig 7 Front View Lower section of unit with facia cover removed

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 9 Installation Procedures Connecting to the Electrical Supply CAUTION: Risk of electric shock when opening aluminium case. Do not remove casing unless this unit is being serviced by a qualified service personnel. The internal components of the Airblade TM may result in electric shock to the user if the casing is removed and handled improperly. Please consult the Dyson Airblade TM Service Manual for proper servicing and care of unit. WARNING: To reduce the risk of fire or electric shock, do not expose the internal mechanism of this unit to rain or moisture. Fig 8 View from Back Electrical supply connection Make sure that all connections are made in accordance with federal, state and local codes and regulations. Make sure that the incoming cable and/or connectors are secured to the back plate in the location illustrated in Fig 8. Once secured, ensure that there is enough wire to reach the terminal block. Secure the Live, Neutral and Ground wires into the proper terminal block locations. Re-establish power to the unit and test for proper voltage. Refitting Front Fascia Panel & Access Panel Attach the front fascia panel back on by latching the top clip first onto the unit and then pivoting the fascia cover downward until flush. Install the bottom left and right tamper proof screws back into the machine using the supplied tool. Install the (2) tamper proof screws back into the inner section of the fascia panel. Re-install the Access panel and (1) tamper proof screw. 8

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 10 Final Inspection Inspection Advice 9 Ensure that machine turns on when hands are placed inside the Airblade TM hand dryer. Please register your product information with us. You may send in the completed registration card in the provided pre-paid envelope. Call our Dyson Helpline toll free at 1-888-DYSON-AB Visit us on the web at www.dysonairblade.com Cleaning and Maintenance Advice Cleaning Advice Surfaces Make sure that all surfaces of the Airblade TM hand dryer are cleaned regularly with a soft cloth and non-abrasive, noncaustic cleaning fluid. Maintenance Advice Air Inlet Regularly check at the base of the Airblade TM hand dryer to ensure that it is free from dust and debris. If the air inlet gets dirty simply remove dust or debris with a dry cloth or vacuum.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 11 Troubleshooting Important: Turn off power before troubleshooting Note: Please try and have model & serial number available before making call. The model/serial plate is located on the left, lower side corner of the unit. Problem Action If Problem Persists The Airblade TM hand dryer fails to start. Check to make sure the unit is connected to correct power supply, and that it is turned on. Call Dyson Helpline at 1-888-DYSON-AB The Airblade TM hand dryer is turning on and off erratically. Check sensor lenses are clean. Call Dyson Helpline at 1-888-DYSON-AB The Airblade TM hand dryer sometimes cuts out when in use, but resumes operation after a period of time. Check the air inlet at the base is clean and free of dust. If the air inlet is dusty, simply remove dust with dry cloth or vacuum cleaner. Call Dyson Helpline at 1-888-DYSON-AB Air is coming out of the front or back of unit. Check for and remove any obstructions. Call Dyson Helpline at 1-888-DYSON-AB This product is protected by the following Intellectual Property Rights Patent/Patent Application Nos: GB 0515750.8 GB 0600872.6 GB 0600537.5 GB 0600868.4 GB 0602465.7 GB 0600534.2 GB 0600869.2 GB 0515749.0 GB 0600879.1 GB 0515741.7 GB 0515754.0 GB 0600536.7 GB 0515744.1 GB 0600881.7 GB 0515739.1 GB 0600880.9 GB 0515752.4 GB 0602075.4 Equivalent patents, registered designs and applications exist in other countries NSF Protocol 335 Hygienic Commercial Hand Dryers 10

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 12 Limited Warranty Information Limited 5 Year Parts Warranty 11 5 year parts limited warranty Additional 1st year labor limited warranty Dedicated Dyson helpline Nationwide field service coverage The full terms and conditions of the Dyson limited warranties are described on the following pages. Thank you for choosing to buy a Dyson. If you have a question about the Dyson Airblade hand dryer, please call Dyson Helpline at 1-888-DYSON-AB with your serial number and purchase information. Your serial number can be found on the serial plate, located at the lower left side of the unit. Most of the time problems can be handled over the phone by our trained technical support staff. If service is required (which may include replacing a defective part), our staff will coordinate and discuss options to have your machine serviced by Dyson or its authorized agent. If your machine is covered under warranty, and the repair is covered, Dyson will provide replacement parts at no cost to the unit owner (which can be installed by Dyson or its authorized agents for additional costs at prevailing rates) for a period of 5 years from date of purchase (or date of delivery, whichever is later). In addition, during the 1st year, this warranty provides at no extra cost to unit owner all the labor necessary to ensure that your Dyson Airblade hand dryer is in proper operating condition. All repair work pursuant to this warranty must be carried out by Dyson or its authorized agents. Repairs or replacement of your Dyson Airblade machine under any Dyson warranty will not extend the period of any warranties herein. The product owner is responsible for securing access to the product. Any parts replaced or removed by Dyson or its authorized agents during the first year will become the property of Dyson.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 13 Limited Warranty Information Please register you product with us. There are 3 ways to do this. You may fill out and send in the completed pre-paid registration card Call our Dyson Helpline toll free at 1-888-DYSON-AB Visit us on the web at www.dysonairblade.com This will confirm ownership of your Dyson Airblade hand dryer in the event of an insurance loss and enable us to contact you if necessary. Example of rating plate Your serial number can be found on the rating plate. Note your serial number for future reference: 5 Year Parts Limited Warranty All factory parts of your Dyson Airblade hand dryer are warranted against original defects, material and workmanship when used in accordance with the Owner s Manual for a period of 5 years. The 5 year parts limited warranty commences on the date of purchase (or on the date of delivery, whichever is later). The 5 year parts limited warranty will expire on the fifth anniversary of its commencement. The unit owner must provide proof of purchase before any replacement parts will be provided for repair pursuant to this warranty. Without this proof of warranty, the owner is liable to pay for any parts on the product by Dyson or its authorized agents at the prevailing rate. All functional factory replacement parts can be installed by Dyson or its authorized agents for additional costs at the prevailing rates. Additional 1st Year Labor Limited Warranty This warranty commences on the date of purchase (or on the date of delivery, whichever is later). The 1 year labor limited warranty will expire on the 1st anniversary of its commencement. In addition, during the 1st year, this warranty provides at no extra cost to unit owner all the labor necessary to ensure that your Dyson Airblade hand dryer is in proper operating condition. All repair work pursuant to this warranty must be carried out by Dyson or its authorized agents. Any labor charges involved with defective replacement parts after the 1st year labor limited warranty expires are the sole responsibility of the product owner. 12

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 14 Limited Warranty Information 13 The 5 year parts limited warranty and the additional 1st year labor limited warranty are subject to the following: What is not covered by the 5 year parts limited warranty or the 1 year labor limited warranty. Dyson B2B, Inc. shall not be liable for costs incurred as a result of: Machines purchased from an unauthorized dealer. Accidental damage, faults caused by negligent use or care, misuse, neglect, careless operation or handling of the machine which is not in line with the Dyson Airblade Owner s Manual. Use of parts not in accordance with the Owner s Manual of the Airblade hand dryer. Blockages, other than those caused by soap and water in normal use. In case of other types of blockages please refer to the Troubleshooting section of the Owner s Manual or call the Dyson Helpline for advice. External sources such as weather. Repairs or alterations carried out by unauthorized parties or agents. Faulty installation except where installed by Dyson B2B, Inc. or an authorized agent. Use of parts and/or accessories other than those produced, assembled, installed or recommended by Dyson B2B, Inc. or an authorized agent. If you have any doubts as to what is covered by your warranties, please call the Dyson Helpline at 1-888-DYSON-AB. Warranty Service Please fill out and return the Product Registration Form, or register on line at www.dysonairblade.com or call the Dyson Helpline at 1-888-DYSON-AB. Before any service can take place, the terms of both warranties require that you contact the Dyson Helpline with your serial number, and the date of purchase or delivery (which ever comes later). Please keep your purchase receipt or information in a safe place to ensure that you have this information available. All covered repair work will be carried out by Dyson B2B, Inc. or its authorized agents. Any replaced defective parts will become the property of Dyson B2B, Inc. during the first year. Service under the warranties (which may include replacing a defective part) will not extend the period of any warranty. If your machine is not functioning properly, please call the Dyson Helpline at 1-888-DYSON-AB. Most issues can be resolved over the telephone by our trained helpline and technical support staff. If this is not possible, Dyson B2B, Inc. will arrange for your Dyson Airblade to be repaired pursuant to the terms of the Dyson Airblade warranties. Other Limitations and Exclusions of Warranties Any implied warranties by the Dyson Airblade hand dryer, including but not limited to warranty of merchantability or warranty of fitness for a particular purpose, are limited to the duration of this warranty. This limitation is not allowed by some states and so this limitation may not apply to you. Your remedy for breach of the warranties are limited to the warranties described above. Dyson B2B, Inc. will not be liable for any consequential damages or incidental damages you may incur in connection with your purchase and use of your Dyson Airblade hand dryer. This limitation is not allowed by some states and so this limitation may not apply to you. These warranties give you specific legal rights. You may have other rights which may vary by state. These warranties are not transferable.

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 15

17728_AB02_OP_MAN_v2.qxd 30/5/07 16:42 Page 16 Contacting Dyson Dyson Helpline can be contacted by calling 1-888-DYSON-AB When calling the Dyson Helpline, please make sure you have the serial number and the purchase date of the Airblade TM hand dryer ready. The serial number can be found on the warranty registration information enclosed or the serial plate located on the lower left side of the unit. Limited Warranty Information The Airblade TM hand dryer is covered by a 5 year parts limited warranty and an additional 1st year labor limited warranty. See enclosed warranty registration information for details. You can register your warranty online at www.dysonairblade.com or by calling 1-888-DYSON-AB For further information about what is included in the Dyson 5 year parts limited warranty and an additional 1st year labor limited warranty, please visit www.dysonairblade.com PN.11760-02-03 JN.17728 30.05.07