Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Similar documents
Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

Engineering Plan Views

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

RLNIE with INNOVATOR II

RLT with INNOVATOR Doors

RMN with INNOVATOR Doors Technical Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

LifeLine Premier RLNIE

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

PWEE Technical Data Sheet

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FG-L Technical Data Sheet

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _F NSF Certified June 2010

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

Nosing Heater. Return Grill Heater

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

RL with INNOVATOR Doors

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

LWU Technical Data Sheet

RFLNS, RFMNS & RFLTM Freedom Line

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

RFLN & RFMN Freedom Line

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

Reach-in Merchandisers

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

NFW, NCW, NFWG, NCWG, NFWE, NCWE

MD Medium Temperature Self Contained Open Vertical Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

Installation & Service Manual

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Installation & Service Manual

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

Medium Temperature Bulk Produce and Bakery Merchandisers

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

MD Medium Temperature Self Contained Open Vertical Merchandisers

BCH Medium Temperature Merchandisers

Installation & Service Manual

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

Self-Contained MERCHANDISERS. February

Installation & Service Manual

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

EcoVision Door Manual

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

F-6 Multi-deck Frozen Food Wall Merchandisers

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

CU0415, CU0715 and CU0920 Service Parts

Installation & Service Manual

Self-Contained MERCHANDISERS. October

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

SERIES NAV S Display Merchandisers

Ultra Low Front Rear Load Medium Temperature

Installation and Operation Manual

LTH Low Temperature Merchandisers

N5FGA, N5NGA, N5FGNA, N5NGNA

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

KR Electrical Defrost Unit Coolers (PN E108318_E)

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

Transcription:

Freedom Line RFLN with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready M G N F J or INNOVATOR III Doors P/N 0537768_J NSF Certified May 18 A Warning: Terminal block NOT for case-to-case wire connection! L K E I D C B H We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # (Qty) Description Wiring Item # Fan Assemblies, and Thermostats A. 12W Standard Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator 0461805 Fan Blade Relays B. 0344662 Defrost Limit Thermostat (2) C. 0342599 Fan Control Relay (3) (8V) Electrical Defrost (KG Only) Heaters D. Electric Defrost Heaters Front (8V) (4) 30518 (1) 1 Door Models 30372 (1) 2 Door Models 30373 (1) 3 Door Models 30374 (1) 4 Door Models 30375 (1) 5 Door Models Electric Defrost Heaters Rear (8V) (5) 30519 (1) 1 Door Models 30376 (1) 2 Door Models 30377 (1) 3 Door Models 30378 (1) 4 Door Models 30379 (1) 5 Door Models E. Drain Pan Heater Electric (1V) (6) 0489708 (1) 1 Door Models 0387036 (1) 2 Door Models 0387037 (1) 3 Door Models 0387038 (1) 4 Door Models 0387039 (1) 5 Door Models Item Part # Description Wiring Item # Control Panel F. 3007825 Dixell XR75 Control (7) G. 0334802 Dixell Discharge Air Sensor (8) H. 0334802 Dixell Defrost Sensor (9) Refrigeration I. 0516897 Condensate Pump (10) J. 0538255 Condensate Pan with Heater (11) (Evapoway) K. 0460992 TEV 2 Door Models 0460993 TEV 3-4-5 Door Models LED Fixtures and Power Supply L. 0499399 Power Supply (12) M. Door Lamp, LED BU.4440877 4100K Center (13) BU.4440878 4100K End (14) N. Facade Lamp, LED BU.4441411 2900K 29.5 In. Length () BU.4441412 2900K 30.5 In. Length () Refer to Innovator Reach-In Glass Door Installation and Service manual, P/N 0425683, for Innovator, and Innovator II door and frame replacement parts. Note: Revision J: Added 1 door information. Other changes marked with a bar, circle or underline. Datasheet - Freedom Line RFLN 18 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0537769

Engineering Plan Views Reach-In 2, 3, 4 & 5 Door Freedom Line Standard Narrow Footprint Plan View 2, 3, 4 & 5 Door Freedom Line RFLN - RFMN Plan View PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Dimensions shown as inches and (mm). 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or Flat Surface Maintain air circulation to reduce condensation. A C 11 (279) E 7 (8) Skid/ External Base Waste Outlet 48 (1219) 6 (2) Bottom Front Support Top Mount Electrical Box Approximate Location (508) 30 5 /8 (778) 39 3 /4 (1010) Electrical Splashguard Water Seal (see note **) Relay & Terminal Block Location 66 1 /4 (1683) 26 1 /2 (673) Front 5-Door Shown Door Swing Clearance 1 Dr 2 Dr 3 Dr 4 Dr 5 Dr General (A) Merchandiser Length 31 1 /2 (800) 62 (75) 92 1 /2 (2350) 122 7 /8 (3121) 3 3 /8 (3896) **NOTE: Each solid end adds approximately 2 3 /8 in (60 mm) to length of line up; each partition add approximately 2 3 /4 in (70 mm); case to case joints can add approximately 1 /8 in (3 mm) for gasket material. Maximum O/S dimension of merchandiser back to front *** 39 3 /4 (1010) 39 3 /4 (1010) 39 3 /4 (1010) 39 3 /4 (1010) 39 3 /4 (1010) *** Add 26 1 /2 in. (673 mm) for door swing. Back of merchandiser to rear of splashguard 35 7 /8 (911) 35 7 /8 (911) 35 7 /8 (911) 35 7 /8 (911) 35 7 /8 (911) Width of Skid rail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom Front Support 6 (2) 6 (2) 6 (2) 6 (2) 6 (2) Stub-up area between front support and splashguard 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) Electrical Service (dimensions are approximate) (B) RH end of merchandiser to center of Electrical Service Area 11 (279) 11 (279) 11 (279) 11 (279) 11 (279) Back O/S of merchandiser to center of Electrical Service Area (508) (508) (508) (508) (508) * NOTE: Electrical Field Wiring Connection Point is at top of merchandiser. Waste Outlet (C) Right end of merchandiser to center of waste outlet 3 /4 (400) 23 7 /8 (606) 54 1 /4 (1378) 46 1 /4 () 76 5 /8 (1946) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser. Refrigeration Outlet (D) RH end of merchandiser to center of refrigeration interface 5 3 /8 (136) 5 3 /8 (136) 5 3 /8 (136) 5 3 /8 (136) 5 3 /8 (136) Back O/S of merchandiser to center of refrigeration interface 49 5 /8 (1260) 49 5 /8 (1260) 49 5 /8 (1260) 49 5 /8 (1260) 49 5 /8 (1260) * NOTE: Refrigeration interface is at top of merchandiser. Outside bottom front supports from end of merchandiser 7 (8) 7 (8) 7 (8) 7 (8) 7 (8) Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610) 24 (610) Distance between Center and Outside supports will vary (E) Depth when disassembled for door entry 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) 2 of 8 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFLN with Innovator Doors

Freedom Line Narrow Footprint Reach-in Top-Mount-Refrigeration Ready 2, 3, 4 and 5 Door Models Standard Reach-in configuration consists of Innovator I doors, energy efficient fan motors, and EcoShine II LED vertical lighting. (508) to 21 (533) Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE energy efficiency standards. Provide adequate clearance for air circulation at rear to reduce condensation. Dimensions shown as inches and (mm). Note: An optional Louvered Facade Panel kit is available that will allow for the top spacing minimum clearance of 3 inches (76 mm). Ceiling 5 1 /2 (140) Minimum 2 1 /8 (54) 7 x 10 x 2 1 /2 Electrical Field Connections 37 (940) 36 1 /4 (924) in. Facade Shown Refrigeration Interface and Electrical Field Wiring Connection are at Top (508) Note: Facade is field-installed. Electrical connection box, external supports, door handle and front raceway may be removed to facilitate passage through door way. 4 in. (102 mm) Required Air Gap 2 5 /8 (67) 102 1 /2 (2603) to 103 1 /2 (2629) Installed Freedom Line RFLN REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. FF IC AHRI Rating* Discharge Air ( F) 5 12 2 Evaporator ( F) 11 19 7 Unit Sizing ( F) 14 22 10 *With door A/S controller Btu/hr/Door Innovator Parallel 955 1065 910 Conventional 970 1085 940 Innovator III Parallel 935 1035 Conventional 955 1055 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 82 1 /4 (89) 65 1 /2 (1663) Door 62 1 /2 (88) 82 3 /4 (2102) DEFROST DATA FF IC Frequency (hr) 24 24 Defrost Water (lb/dr/day) 1.2 1.2 (± % based on merchandiser configuration and product loading.) 67 (02) Frame 22 Shelf (559) Electric FF IC Temp Term ( F) 48 48 Failsafe (minutes) 45 45 23 5 /8 (600) Gas Offtime Not Available Not Recommended 6 1 /4 (9) 13 1 /8 (333) 4 3 /4 (121) 3 7 /8 (97) Fan Coil 30 5 /8 (778) 35 7 /8 (911) 39 3 /4 (1010) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. CONVENTIONAL CONTROLS Cut In Cut Out HPC (psig) 3 395 LPC (psig) 5 Working charge with recommended Condensing Unit installed: 1Dr 2.9 lb 46 oz 1.3 kg 2Dr 5.3 lb 85 oz 2.4 kg 3Dr 10.3 lb 165 oz 4.7 kg 4Dr 6.9 lb 110 oz 3.1 kg 5Dr 9.2 lb 147 oz 4.2 kg P/N 0537768_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 8

Freedom Line RFLN Electrical Data 1Dr 2Dr 3Dr 4Dr 5Dr Number of Fans 12W 1 2 3 4 5 Amperes Merchandiser 1Dr 2Dr 3Dr 4Dr 5Dr 1Dr 2Dr 3Dr 4Dr 5Dr Energy Efficient Evaporator Fan 1V 50/60Hz Innovator 0.30 0.60 0.90 1. 1.50 18 36 54 72 90 Door Anti-sweat Heaters (on fan circuit) 1V 50/60Hz Innovator 0.76 1.50 2.30 3.00 3.80 91 182 273 364 455 1V 50/60Hz Innovator III 0.43 0.9 1.3 1.7 2.2 52 104 6 8 260 Frame Anti-sweat Heaters (on fan circuit) Hussmann recommends against frame heater cycling with Innovator doors or Innovator III doors to prevent door seals from freezing to the frames and tearing. 1V 50/60Hz Innovator 0.39 0.78 1.18 1.57 1.97 47 94 141 188 236 Watts Heated Condensate Pan 5.0 5.0 5.0 5.0 5.0 600 600 600 600 600 Condensate Pump 1.9 1.9 1.9 1.9 1.9 87 87 87 87 87 Defrost Drain Heaters (1V) 1.67 0.63 1.25 2.00 2.57 0 75 0 240 300 8V 1ø Electric Defrost 2.88 6.72 10.08 13.46 16.82 600 1400 2100 2800 3500 1V Circuit (Fans, anti-sweat heaters, drain pan heater, condensate pan heater, condensate pump, and standard EcoShine 2 LED s) With Innovator Doors (standard) 9.9 10.4 12.9.4.8 1044 11 1370 1637 1876 With Innovator III Doors 9.6 9.8 11.9 14.1 16.2 1005 1039 1253 1481 1681 Maximum Overcurrent Protection Device (MOPD) 8V Circuit 8V Circuit (Defrost heaters) 2.8 6.7 10.1 13.5 16.8 600 1400 2100 2800 3500 Maximum Overcurrent Protection Device (MOPD) Refer to condensing unit data sheet for additional condensing unit electrical requirements Standard Vertical LED ing 1Dr 2Dr 3Dr 4Dr 5Dr 1Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II - A (1V) 0.18 0.31 0.46 0.62 0.77 18.5 37.1 55.6 74.2 92.7 Notes: 1. Electrical input for the RFLN Freedom case requires two electrical connections at the top of the case: one 1V connection for the RFLN case components and one 8/230V connections for the defrost heater and condensing unit. Defrost heater and condensing unit circuits are non-concurrent loads. To determine the circuit size, use the larger of the two loads - do not add the two loads together. 2. Without heated condensate pan and pump, subtract 6.9 Amps A qualified electrician should perform all wiring in accordance with the NEC code and/or all local codes. Wire sizing must take into account the total distance from the electrical panel to the Freedom case. 4 of 8 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFLN with Innovator Doors

Product Data Recommended Usable Cube 1 (Cu Ft/Dr) AHRI Total Display Area 2 (Sq Ft/Dr) Shelf Area 3 (Sq Ft/Dr) Freedom Line RFLN 22.80 ft 3 /Dr (0.65 m 3 /Dr) 13.04 ft 2 /Dr (1.21 m 2 /Dr) 28.50 ft 2 /Dr (2.65 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 10 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. ESTIMATED SHIPPING WEIGHT 4 1 Dr 2 Dr 3 Dr 4 Dr 5 Dr Solid End (each) Standard Freedom Line Merchandiser (18-Inch Facade, no Arch) lb (kg) 6 (80) 1085 (492) 1357 (616) 1828 (829) 2230 (1012) 74 (34) 4 Actual weights will vary according to optional kits included. P/N 0537768_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 8

Freedom Line RFLN CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = P = Purple 2P = Purple (2 Bands) DB = Dark BK = LB = BR = Brown Y = Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY.) CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit overcurrent protection is larger than the individual merchandiser's defrost circuit load, then additional supplemental overcurrent protection may be required per NEC Articles 210 and 240. Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. 8 V 8 V 1 2 3 FANS 1 V 14 REAR DEFROST FRONT DEFROST FAN RELAY F NC COM F NO FAN RELAY COIL F 8 7 6 FANS DASH CONTROLLER 16 LINE NEUTRAL 9 5 4 3 DEFROST LIMIT O.O.R. 1 ROD HEATER (DRAIN) 6 4 5 FANS NEUTRAL 26 25 24 3024448_C 13 HEATER DASH CONTROLLER FRAME A.S. 22 NEUTRAL DASH CONTROLLER DOOR A.S. 12 21 (1 V) (NEUTRAL) SWITCH L FIELD WI DEFROST TERMINATION THERMOSTAT C.O.R. THE HEAVY LINES DRAWN INSIDE THE TERMINAL BLOCKS REPRESENT PERMANENT INTERNAL JUMPERS. 1 2 3 4 5 6 7 8 10 11 12 13 14 16 21 22 24 25 26 DEFROST HEATERS (8V) DEFROST HEATERS (8V) FANS & A/S (1V) (1V) (NEUTRAL) FANS, & A.S (NEUTRAL) THE HEAVY LINES DRAWN OUTSIDE THE TERMINAL BLOCKS REPRESENT REMOVABLE EXTERNAL JUMPERS. Electric Defrost Sequence - 1. Power from the defrost relay energizes Defrost Heaters and 8V Evaporator Fan Relay Coil (5). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. When Defrost Termination Thermostat ends defrost period, the defrost relay opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off and fans are on. 6 of 8 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFLN with Innovator Doors

CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = P = Purple 2P = Purple (2 Bands) DB = Dark BK = BL = BR = Brown Y = Yellow OR = Orange W = Freedom Line RFLN THESE ARE MARKER COLORS (WIRE MAY VARY). ELECTRIC BOX ON TOP OF CASE 26 23 22 21 14 L1 L2 8 V 1 PHASE 60 HZ INPUT GROUND D/A TEMPERATURE SENSOR DEFROST TERMINATE SENSOR 9 8 24 23 22 21 19 18 16 XR75CX 7 8 7 6 5 4 3 2 1 BROWN BLUE COMPRESSOR RELAY DEFROST RELAY 13 12 11 10 DISCONNECT SWITCH FIELD INSTALLED CONDENSING UNIT L1 L2 GFCI OUTLET 1V 1 V NEUTRAL 11 CONDENSATE PAN HEATER CONNECT TO LEADS PROVIDED ON TOP OF CASE 1 4 12 14 DEFROST HEATERS 8 V DOOR FANS A/S & A/S 1 V 1 V C 1 V N 26 FANS & A/S N CONDENSATE WATER PUMP 10 3007294_C RACEWAY Dixell Wiring Diagram Reach-in P/N 0537768_J HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 8

Freedom Line RFLN Standard Vertical ing Hussmann EcoShine LED Fixtures 16 16 1 Door LED Wiring Diagram 2 Door LED Wiring Diagram 16 16 3 Door LED Wiring Diagram 16 16 16 4 Door LED Wiring Diagram 16 16 16 16 5 Door LED Wiring Diagram WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled numbers = Parts List Item Numbers R= Y = Yellow G = Green BL = BK = W + = 1V Power = 1V Neutral = Field Ground = Case Ground 8 of 8 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFLN with Innovator Doors