ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Similar documents
PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

A study of Transient Performance of A Cascade Heat Pump System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Using Evaporative Cooling Methods for Improving Performance of an Air-cooled Condenser

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Reduction Of Energy Consumption in Airconditioning Systems employing direct evaporative pre-cooling of Condenser air

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

AIRFLOW STUDY OF A SPILT-TYPE OUTDOOR UNIT SUBJECTED TO NEAR WALL EFFECT USING COMPUTATIONAL FLUID DYNAMIC (CFD) SIMULATION

Low GWP Refrigerants for Air Conditioning Applications

Performance investigation of Air-conditioning system using ejector as expansion device

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Purdue e-pubs. Purdue University

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Performance Improvement of Air Conditioning System using Applications of Evaporative Cooling: A Review Paper

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Modified Air Cooler with Split Cooling Unit

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Design and Development of Combined Direct and Indirect Evaporative Cooling System

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Performance Optimization of the Evaporative Condenser Design

Application Engineering

Transcritical CO2 Bottle Cooler Development

Oxyvap Evaporative Cooling Applications

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

AN EXPERIMENTAL INVESTIGATION INTO THE EFFECT OF THERMOSTAT SETTINGS ON THE ENERGY CONSUMPTION OF HOUSEHOLD REFRIGERATORS

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

THERMAL ANALYSIS OF CAR AIR COOLER

Enhancement of COP in Vapour Compression Refrigeration System

Mathematical Simulation of Longan Fruit Drying

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

Review of flow-through design in thermoacoustic refrigeration

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Global Journal of Engineering Science and Research Management

Experimental Evaluation of a Gas Engine Driven Heat Pump Incorporated with Heat Recovery Subsystems for Water Heating Applications

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Research on Waste Heat Recovery System for Residential Gas Engine-Driven Heat Pump

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Transcription:

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS Chainarong Chaktranond *, and Peachrakha Doungsong Department of Mechanical Engineering, Faculty of Engineering, Thammasat University Khlong Luang, Pathum Thani, Thailand Tel: -5-3-9 ext. 3, Fax: -5-3-9 ext. 35, E-mail: cchainar@engr.tu.ac.th Abstract This paper presents an experimental investigation of the use of various indirect evaporative cooling types to reduce energy consumption in a domestic split-type air conditioner. The condensing unit is retrofitted with a corrugated media pad type evaporative cooler, water sprayers, a water source and a pump. The power consumption and refrigeration capacity obtained from various cooling types are monitored and compared. The results show that the electrical consumption and coefficient of performance (COP R ) significantly depend on the ambient conditions. Due to effects of condensing pressure, when the ambient temperature rises, the electrical consumption becomes higher, while the COP R becomes lower. Utilizing the indirect

evaporative cooling system decreases the temperature of air entering the condensing unit, and then it makes the system performance enhance considerably. Among the investigated cases, the maximum energy saving occurs when the water spray works together with cellulose cooling pad. With the evaporative cooling systems, COP R is improved by around -%, and electrical consumption is approximately reduced by -5%. Keywords: Indirect evaporative cooling, Split-type air conditioner, Energy saving.. INTRODUCTION With impact of energy crisis and global warming, many researches have paid much attention on strategies for saving energy. In the tropical climate countries such Thailand, more than 5% of total electrical consumption in residential and commercial buildings comes from air conditioning systems. Due to simplicity and flexibility, the conventional split-type air conditioner is widely used in small and medium size buildings, e.g. residences, offices, and schools. Condensers used in this air conditioner are mainly air-cooled. In addition, their performances depend on the heat transfer between coils and the ambient airflow. Chow et al. () reported that if the on-coil temperature of a condensing unit were raised by O C, the coefficient of performance (COP R ) of the air conditioner would drop by around 3%. In addition, if this temperature remained above 5 O C for an extended period, the air conditioner would trip because of the excessive condenser working pressure. Effect of hot air recirculation on condensing temperature was studied by Avara and Daneshgar (). It was found from their numerical results that the distance between

walls (L), where a condensing unit was installed, affected the on-coil temperature. If L was less than.5 m, the air flow should be parallel to the walls. In addition, if L =.5 m, optimal distance of condenser from the supporting wall (D) was 35 cm. Selecting a greater D led to more hot air circulation and consequently increased the on-coil temperature. Hu and Huang (5) improved the system performance of a water-cooled air conditioner by utilizing the cellulose pad, which was in cellulose bound cardboard structure. Instead of plastic packing in a cooling tower, this cellulose pad depressed the effect of surface tension on the plastic surface. This caused the contact area between air and water to be increased, resulting in enhancement of heat transfer. To improve the COP R and save energy in refrigeration and air conditioning systems, Vrachopoulos et al. (7) developed an incorporated evaporative condenser, which was installed with a cooling water sprinkle network in the front. In this method, water was directly sprayed into air-stream. The results showed that COP R was improved up to % and energy saving was up to 5%. However, since the air filled with water droplets was directly induced to the condensing unit, corrosion problem possibly occurred on equipment. In order to reduce the condensing temperature in a window-type air conditioner, Hajidavallo (7) installed two cooling pads in both sides of the air conditioner and injected water on them. With the cooling pads, the water droplets, which were exchanged the heat with hot-air flow, were trapped and dropped to the bottom. Hajidavallo (7) reported that with evaporative cooling pad, the energy consumption decreased by about %, and the COP R increased by about 55%. In this study, the energy saving in a domestic split-type air conditioner is performed by retrofitting condensing unit with various types of indirect evaporative cooling system. Air-stream entering condensing unit is cooled down at two positions, i.e. in the front of and within cellulose

corrugated pad. Moreover, injecting water into the air is divided into two types: water curtain and water spray. Comparison on system performances obtained from each case is reported in this study.. EXPERIMENTAL STUDY AND INSTRUMENTATION From the name plate given by manufacturer, cooling capacity of the split-type air conditioner is 3,5.9 Btu/hr (. kw), and condenser fan is 7 W (full load amp =.79 / volts). The condensing coil is rectangular in shape and is placed outside the building. Distance between condensing unit and wall is.3 m. The ambient air is drawn into the condensing unit from two sides, and the hot air is exhausted in the horizontal direction. The evaporative cooling pad unit of.5 m thick is placed in the front of condensing unit. As shown in Fig., the unit consists of cellulose pad, water pipe networks, which are located above and in front of cellulose pad (at position A, and B), a pan at the bottom, and a small water pump of W to pump water with the maximum flow rate of.7 m 3 /min. In the cases using water curtain, water pipe at position B is bored with. m in diameter and spacing between bores is. m. While in the cases using water spray, the pipe network is replaced with spray bars at positions B and C. Along the spray bars are bored and installed with sprayers, where spacing between them is.5 m. Spray heads are installed normal to the direction of air-stream entering the condensing unit. Distance between the cooling pad unit and condensing unit is.5 m.

3 A B Air flow C Fig. Schematic diagram of evaporative cooling system. A power meter (CHAUVIN ARNOUX SERIES C.A.3) is used to monitor the total power consumption including compressor, evaporator fan and condenser fan. TESTO is used for measuring temperature and humidity of outdoor conditions (position,, and 3 shown in Fig.) and indoor conditions (upstream and downstream of the evaporative coil). Average flow rate of air-stream entering the condensing unit is,7.7 cfm (.9 m/s). Indoor air condition is controlled with thermostat at 5 O C, and airflow rate exiting from evaporator is. cfm (.93 m/s). Testing conditions are divided into cases shown in Table. Table Testing conditions Case Condition Without cooling system With cellulose cooling pad 3 With water curtain With water curtain and cellulose cooling 5 With water spray With water spray and cellulose cooling

3. RESULTS AND DISCUSSIONS To compare the system performance improved, the air conditioning system is first monitored without the evaporative cooling pad unit at condensing unit. In all experiments, air properties and total electric power consumption are measured and recorded for hours. 3. Total power consumption The results from Fig. show that in the afternoon, the power consumption is higher than the other periods. Particularly, the maximum power consumption occurs in the period of 3. - 7.. This shows that outdoor temperature has much affected the power consumption of air conditioner. In fact, when temperature of air conditioning room reaches a set point, then electrical machines in condensing unit will stop running. Therefore, discontinuity shown in the Fig. is the effect of the cycling machines (starting and stopping the fan motor and compressor). By comparing with case, it seems that the frequency of the cycling machines in the air conditioner retrofitted with evaporative cooling system is more often. This indicates that decreasing temperature of air entering condensing unit also influences the refrigeration capacity in evaporator. The average power saving values in case, case 3, case, case 5, and case approximately are 3., 7., 9.7,, and 5%, respectively.

Power consumption [kw] 3.5.5.5 Case Power consumption [kw] 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 3.5.5.5 Case 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 9: 3 Power consumption [kw] 3.5.5.5 Case Power consumption [kw] 3.5.5.5 Case 5 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 9: 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 9: 3 Power consumption [kw].5.5.5 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 9: Case 3 Case Power consumption [kw].5.5.5 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: 9: Fig. Total power consumption of air conditioner in various cases. 3. System performance In this study, coefficient of performance in refrigeration (COP R ) is defined as the ratio of refrigeration capacity to total power consumption measured by power meter. In addition,

refrigeration capacity is computed in terms of energy transfer from air to refrigerant, and it can be written as where ( ) Refrigeration capacity = m& h h (), a ra sa m& a is mass flow rate of air exiting from the supply air grille, h ra and hsa are enthalpy of supply and return air, respectively. The average system performances are shown in Fig. 3 in which ambient air conditions are presented by temperature ( O C) and relative humidity (% RH). The results show that temperature affects the system performances more than relative humidity. When ambient air temperature becomes lower, the system obtains higher COP R. Due to outdoor air effect, COP R during night time is higher than that during day time. As the day progressed, the ambient temperature increases which results in lower performance due to increased condenser pressure head. In other words, higher condenser pressure results in an increase of power consumption by the compressor. On the other hand, the performance of the system increases when the ambient air temperature drops. By using curve fitting, it is found that electrical power consumption increases by around % when temperature is raised by O C. With indirect evaporative cooling system, ambient air transfers heat to water. This makes temperature of air entering condensing unit lower, then heat transfer between refrigerant flowing through condensing unit and the entering air more increases. Consequently, COP R of the system is improved.

9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case kw COPR Ambient temp x %RH x 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case kw COPR Ambient temp x % RH x 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case kw COPR Ambient temp x % RH x 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case 5 kw COPR Ambient temp x % RH x 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case 3 kw COPR Ambient temp x % RH x 9: : 3: 5: 7: 9: : 3: : 3: 5: 7: Case kw COPR Ambient temp x % RH x Fig. 3 System performance in various cases. 3.3 Comparison on power consumption The outdoor and indoor air conditions are shown in Table. With indirect evaporative cooling systems, temperature of air entering condenser can approximately reduce by 3 O C in maximum, and relative humidity is 5% in maximum. Moreover, the indirect evaporative cooling influences

power consumption and refrigerating effect (Δh in room) of air conditioning system, resulting in improvement of COP R. Table. Outdoor and indoor air conditions Ambient After passing After passing Case Condition T condition RH cooling device T RH condensing unit T 3 RH 3 kw Δh in room COP R [C] [%] [C] [%] [C] [%] Without water cooling system 3. 3.9 3. 3.9 3...3..35 With cooling pad 9.79 7.3 7.59.5 3. 5..5.73.3 3 With water curtain 3..7 3. 7. 3.99 5.3.5 3.5.9 With water curtain and cooling pad 3. 7.3.97.5 3. 59.5.7..77 5 With water spray 3.33 7.73 9.3. 35. 59.5...7 With water spray and cooling pad 3. 9.79 7. 5.3 3. 5.37.3 5.5. Figure shows the comparison on average power consumption per ton of refrigeration among various cases. Air conditioner with water spray and cooling pad (case ) provides the minimum value of kw/ton. This is because air-stream entering the condensing unit has more contact with cooling water. Hence, heat can much transfers from refrigerant to air-stream, and then condenser pressure head is lower. By comparing the case without the cooling water system (case ), it is found that the electrical power saving values in case to are around, 7.7, 9.,., and 5.3%, and system performances are improved around., 5., 3.7, 3., and 9.5 %, respectively. Even though the evaporative cooling system reduces the power consumption, influence of corrosion due to high humidity on equipment should be considered.

case case case 3 case case 5 case kw/ton Tin cond x %RHin cond x Tout cond x %RHout cond x Fig. Comparison on power consumption among various cases.. CONCLUSIONS Improvement of system performance in a domestic split-type air conditioner with various types of indirect evaporative cooling systems is investigated in this study. Based on the experimental results, it reveals that ambient temperature has much influenced the power consumption of compressor and COP R. When temperature is raised by O C, electrical power consumption increases by around %. With evaporative cooling, the air entering condensing unit is cooled to a lower temperature. This causes the power consumption by compressor to decrease, and the refrigeration capacity to increase, resulting in enhancement of COP R. Due to high contact surface between water and air-stream, indirect evaporative cooling system using spray water and cellulose cooling pad together can decrease the power consumption around by 5%, and can increase COP R up to 5%.

ACKNOWLEDGEMENTS The authors would like to thank Department of Mechanical Engineering, Thammasat University for the financial support and measurement devices. REFERENCES Avara, A., and Daneshgar, E. Optimum placement of condensing units of split-type air conditioners by numerical simulation, Energy and Buildings ; : -7. Chow, T.T., Lin, Z., and Yang, X.Y., Placement of condensing units of split-type airconditioners at low-rise residences, Applied Thermal Engineering ; : 3-. Hajidavallo, E. Application of evaporative cooling on the condenser of window-air-conditioner, Applied Thermal Engineering 7; 7: 937-93. Hu, S.S., and Huang, B.J. Study of a high efficiency residential split water-cooled air conditioner, Applied Thermal Engineering 5; 5: 599-3. Vrachopoulos, M.G., Filios, A.E., Kotsiovelos, G.T., and Kravaritis, E.D. Incroporated evaporative condenser, Applied Thermal Engineering 5; 7: 3-.