PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

Similar documents
PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-107

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 099

PRILOGA K AKREDITACUSKI LISTINI Annex to the accreditation certificate

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP- 018

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-004

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-047

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-032

SEZNAM AKREDITIRANIH METOD V PRESKUSNEM LABORATORIJU IRMA (LP-008) / LIST OF ACCREDITED METHODS IN TESTING LABORATORY IRMA (LP-008)

Metode preskušanja cementa - 1. del: Določanje trdnosti Methods of testing cement - Part 1: Determination of strength

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

Seznam akreditiranih metod Laboratorij za cemente, malte in keramiko

LME OPREMA I AKREDITIRANE METODE ISPITIVNJA

Glenside Environmental Services Ltd

Seznam akreditiranih metod. Laboratorij za toplotno zaščito in akustiko

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Test procedure/ method identification IP 100 (ISO 9096, ČSN EN )

INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

This document is a preview generated by EVS

OBSEG METOD S FLEKSIBILNIM OBSEGOM AKREDITACIJE. Oddelek za kemijske analize živil, vod in drugih vzorcev okolja, Gosposvetska ulica 12, 4000 Kranj

gas monitoring system

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

portable gas analyser

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ACTIVITIES OF THE MEASURING GROUP

Certificate: _01 / 2 February 2015

Gas Samplers. Compact, user-friendly devices for physically correct gas volume measurements in accordance with the VDI guidelines

P R O D U C T D ATA S H E E T

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Građevinski laboratorij d.o.o. Borongajska cesta 84, HR Zagreb Laboratorij Sesvete Slatinska 7, HR Sesvete

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Laboratorija za ispitivanje građevinskih materijala MMLab d.o.o. Kotor Lasta Grbaljska bb, Kotor

INTERNATIONAL STANDARD

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

Review Fire Test Report

GUIDELINES FOR DESCRIBING THE ACCREDITATION SCOPES OF TESTING LABORATORIES

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

P R O D U C T D ATA S H E E T

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

IMO Resolution MSC 61(67): Annex 1: Part 2

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

P R O D U C T D ATA S H E E T

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Rol van ISSeP als sectoraal operator

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Complete Gas Analysis

Monitores Personales. Personal Monitor

3M Oldham OLCT 100. Description. Fixed Gas Detector

GAS DETECTOR ST400EC PART.NO

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

d. Portable water heaters used exclusively for underwater diving operations.

This document is a preview generated by EVS


Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

CONFIRMATION of Product Conformity (QAL1)

An Introduction to the IECEx System and IECEx Scheme Certification Processes IECEx Secretariat January 2018

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

PREDICTING GASEOUS AIR CLEANER PERFORMANCE IN THE FIELD

This document is a preview generated by EVS

GAS DETECTION International Gas Detectors CH4 NO

HAA je potpisnica multilateralnog sporazuma s Europskom organizacijom za akreditaciju (EA) HAA is a signatory of the European co-operation for

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

PROPOSED October 15, 2013

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

AS/NZS :2008

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Ministerial Decree No. 14/2005 (VI. 28.) KvVM. on the rules concerning the screening surveys of remedial site investigations.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

COMMISSION REGULATION (EU) No /.. of XXX

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

APPLICATION DATA SHEET

COMMISSION REGULATION (EU) No /.. of

EL765. Fire Extinguishers [EL /2/ ]

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

This document is a preview generated by EVS

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

FAST RESPONSE TEMPERATURE SENSORS 42.11a

Fire fighting Questions

Iesf Report l't March 2010

GUIDELINE FOR THE APPLICATION OF SRPS CEN/TS WHEN GRANTING ACCREDITATION TO TESTING LABORATORIES

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Transcription:

Reg. št. 1 Ref. No. : 3151-0156/10-0006 Datum izdaje 1 /ssued on: 13. julij 2015 Zamenjuje izdajo z dne 1 Replaces Annex dated: 18. Junij 2014 spletni strani SA, www.slo-akreditacija.si Information on current accreditation status is available at the SA website, www.slo-akreditacija.si PRILOGA K AKREDITACIJSKI LISTINI Annex to the accreditation certificate LP-076 1 AKREDITIRANI ORGAN 1 Accredited body RACI d.o.o. Tehnološki park 24, 1000 Ljubljana Merilni laboratorij 2 STANDARD SIST EN ISO/IEC 17025:2005 3 OBSEG AKREDITACIJE 1 Scope of accreditation V okviru te akreditacijske listine Slovenska akreditacija priznava akreditiranemu organu usposobljenost za opravljanje naslednjih dejavnosti: 1 SA hereby acknowledges the accredited body as being competent for performing the fo/lowing activities: 3.1 Skrajšan opis obsega akreditacije 1 A short description of the scope Področja preskušanja glede na vrsto preskušanja 1 Testing field s with reference to the type of test: fizikalno preskušanje 1 physica/ testing vzorčenje 1 sampling kemija 1 chemistry 0805-3 1 Izdaja 6 Stran 1 od 6

4 SLOVENSKA Datum izdaje 1/ssued on 13. julij 2015 Področja preskušanja glede na vrsto preskušanca 1 Testing fields with reference to the type of test it em: okolje in vzorci iz okolja (viri emisij snovi) 1 environmnet and samples from the environmnet (sources of emissions of substances) 0805-31 * Izdaja 6 Stran 2 od 6

Datum izdaje 1 /ssued on 13. julij 2015 3.2 Podroben opis obsega akreditacija 1 Detai/ed scope of accreditation 3.2.1 Merilni laboratorij, Tehnološki park 24, Ljubljana Tabela 1 Table 1 Mesto izvajanja: na terenu 1 Site: fieldwork Področja preskušanja glede na vrsto preskušanja: fizikalno preskušanje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fie/ds with reference to the type of test item: environmnet and samples from the enironment (sources of emissions of substances) Št. nestandardne preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Tltle of standard or non- and eventua/ relations to other standards or methods preskuša nja (kjer je to Range of testing; Uncertalnty of the result of 1. SIST ISO 10396:1996 Emisije nepremičnih virov - Vzorčenje za plini avtomatično določanje plinskih koncentracij Stationary source emissions - Sampling for the automated determination of gas concentrations 2. SIST ISO 10780:1996 Emisije nepremičnih virov- Meritev hitrosti in (5-50) m/s plini volumenskega pretoka plinskih tokov v odvodnikih Stationary source emissions- Measurement of velocity and vo/ume flowrate of gas streams in ducts 3. SIST EN ISO 16911-1 :2014 Emisije nepremičnih virov - Ročno in v: (4-55) mis plini avtomatsko določevanje hitrosti (zastojna cev) gases in volumenskega pretoka v odvodnikih - 1. del: v: (0,5-60) m/s Ročna referenčna (krilni anemometer) metoda Stationary source emissions - Manual and automatic determination of velocity and vo/ume flow rate in ducts- Part 1: Manual reference method 4. SIST ISO 12039:2002 Emisije nepremičnih virov- Določevanje CO: (1-2500) ~tlil plini ogljikovega monoksida, ogljikovega dioksida in CO: (0,2- kisika - Delovne karakteristike in kalibracija 0,5/2,5/1 0/50) % avtomatskih merilnih sistemov C02: (0,2-10/50) % Stationary source emissions- Determination of 0 2: (1-10/1 000) ~tlil carbon monoxide, carbon dioxide and oxygen- 0 2: (0,01-1/1 OO) % Performance characteristics and calibration of automated measuring systems 5. SIST EN 15058:2006 Emisije nepremičnih virov- Referenčna metoda CO: (1-50/2500) ~-tlil plini določevanja ogljikovega monoksida z gases nedisperzivno infrardečo metodo Stationary source emissions- Reference method for determination of carbon monoxide in emission by means of the non-dispersive infrared method 6. SIST EN 14789:2005 Emisije nepremičnih virov - Določevanje 0 2: (0,02-2/100)% plini volumske koncentracije kisika (02)- Referenčna metoda- Paramagnetizem; vo/ume concentration of oxygen (02) - Reference method- Paramagnetism 0805-3 1 * Izdaja 6 Stran 3 od 6

Datum izdaje 1/ssued on 13. julij 2015 Mesto izvajanja: na terenu 1 Site: fieldwork Področja preskušanja glede na vrsto preskušanja: fizikalno preskušanje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the type of test item: environmnet and samples from the enironment (sources of emissions of substances) Št. nestandardne preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Title of standard or non- and eventual relations to other standards or methods preskušanja (kjer je to Range of testing; Uncertainty of the result of 7. SIST ISO 10849:1996 Emisije nepremičnih virov - Ugotavljanje masne NO: (4-200/2000) ~tl/l plini koncentracije dušikovih oksidov- Delovne gases karakteristike avtomatskih merilnih sistemov the mass concentration of nitrogen oxides- Performance characteristics of automated measuring systems 8. SIST EN 14792:2006 Emisije nepremičnih virov- Določanje masne NOx: (4-200/2000) ~tlil plini koncentracijse dušikovih oksidov (NOx) - Referenčna metoda: kemiluminiscenca Stacionary source emissions - Determination of the mass concentration of nitrogen oxides- Reference method: chemi/uminisscence 9. SIST ISO 7935:1996 Emisije nepremičnih virov - Ugotavljanje masne SOz: (2-100/1000) 11L/L plini koncentracije žveplovega dioksida - Delovne karakteristike avtomatskih merilnih metod the mass concentration of su/fur dioxide- Performance characteristics of au toma ted measuring methods 10. SIST EN 12619:2013 Emisije nepremičnih virov - Določevanje masnih TOC: (0,1-1/1000) plini koncentracij celotnega organskega ogljika v mg/m 3 gases plinasti fazi - Kontinuirana metoda plamenske ionizacijske detekcije the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method 11. DP02, 2009 Meritev koncentracije plinov - kontinuirno CH4: (0,4-20/100)% plini interna metoda Measurement of gas concentrations - gases in-house method continuous (na osnovi SIST ISO 12039: Emisije nepremičnih virov- Določevanje ogljikovega monoksida, ogljikovega dioksida in kisika- Delovne karakteristike in kalibracija avtomatskih merilnih sistemov based on S/ST ISO 12039 carbon monoxide, carbon dioxide and oxygen- Performance characteristics and calibration of automated measuring systems) 12. DP06, 2009 Meritev perifernih parametrov T: (243-873) K plini interna metoda Measurement of peripheral parameters (-3o- 600) c in-house method p: (800-1200) hpa 13. SIST EN 14790:2005 Emisije nepremičnih virov - Določevanje vodne vlaga: plini pare v odvodnikih (29-250) g/m 3 gases the water vapour in ducts 0805-31 * Izdaja 6 Stran 4 od 6

Datum izdaje 1/ssued on 13. julij 2015 Mesto izvajanja: na terenu 1 Site: fieldwork Področja preskušanja glede na vrsto preskušanja: fizikalno preskušanje; vzorčenje; kemija 1 Testing fields with reference to the type of test: physical testing; sampling; chemistry Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the type of test item: environmnet and samples from the enironment (sources of emissions of substances) št. nestandardne preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Title of standard or non- and eventual relations to other standards or methods preskušanja (kjer je to Range oflesting; Uncertalnty of the result of 14. DP09, 2009 Določevanje prostorninskih deležev plinov v CH4: (0,5-1 OO) % plini interna metoda deponijskem plinu in bioplinu C02: (0,5-1 OO) % gases in-house method Determination of vo/ume fractions of gases in 02: (1,0-25)% /andfi/1 gas and biogas (na osnovi SIST ISO 12039: Emisije nepremičnih virov- Določevanje ogljikovega monoksida, ogljikovega dioksida in kisika - Delovne karakteristike in kalibracija avtomatskih merilnih sistemov ln Environment agency: Performance Standards for Portable Systems for Emission Monitoring based on S/ST /SO 12039: carbon monoxide, carbon dioxide and oxygen- Performance characteristics and calibration of automated measuring systems and Environment agency: Performance Standards for Portable Systems for Emission Monitoring) H2S: (4-200) 11LIL H2: (20-1 000) 11LIL 15. S IST EN 1911 :2011 Emisije nepremičnih virov - Določevanje masne plini samo vzorčenje koncentracije plinastih kloridov, izraženih kot gases HCI -Standardna referenčna metoda; Stationary source emissions- Determination of mass concentration of gaseous chlorides ex pressed as HC/- Standard reference method; 16. ISO 15713:2006 Stationary source emissions- Sampling and plini samo vzorčenje determination of gaseous fluoride conte nt; 17. VDI 3496, Blati 1 (1982) Messen gasformiger Emissionen - Bestimmung plini samo vzorčenje der durch Absorption in Schwefelsaure erfassbaren basischen Stickstoffverbindungen; 18. SIST EN 14791 :2005 Emisije nepremičnih virov- Določevanje masne plini samo vzorčenje koncentracije žveplovega dioksida- Referenčna metoda; Stationary source emissions- Determination of mass concentration of sulphur dioxide- Reference method; 19. VDI 3862, Blati 2 (2000) Messen gasformiger Emissionen - Messen plini samo vzorčenje aliphatischer und aromatischer Aldehyde und gases Ketone nach dem DNPH-Verfahren - Gaswaschflaschen-Methode; Gaseous emission measurement - Measurement of aliphatic and aromatic aldeydes and ke tone s by DNPH method - lmpinger method OB05-31 * Izdaja 6 Stran 5 od 6

Datum izdaje 1 lssued on 13. julij 2015 Tabela 1 Table 2 Mesto izvajanja: v laboratoriju in na terenu 1 Site: in the laboratory and fieldwork Področja preskušanja glede na vrsto preskušanja: fizikalno preskuša nje; vzorčenje 1 Testing fields with reference to the type of test: physical testing; sampling Področja preskušanja glede na vrsto preskušanca: okolje in vzorci iz okolja (viri emisij snovi) 1 Testing fields with reference to the type of test item: environment and samp/es from the environment (sources of emissions of substances) Št. nestandardne preskusne metode in morebitne navezave na druge standarde ali metode No. Reference to standard or non- Tltle of standard or non- and eventual relations to other standards or methods preskušanja (kjer je to Range of testing; Uncertalnty of the result of 20. SIST EN 13284-1 :2002 Emisije nepremi č nih virov- Določevanje (0, 1-1000) mg/m3 plini majhnih masnih koncentracij prahu - 1. del: gases Ročna gravimetrijska metoda; in/ and low range mass concentration of du st- Part 1: Manual gravimetric method SIST ISO 9096:2003 Emisije nepremičnih virov - Ročno določanje masne koncentracije trdnih delcev; Stationary source emissions - Manual determination of mass concentration of particu/ate matter 21. VDI 2066, Blatt 10 (2004) Messung der Emissionen von PM1o und PMz,s PM10: (1-20) mg/m 3 plini an GefOhrten Quellen nach dem PMz,s: (1-20) mg/m 3 gases lmpaktionsverfahren 22. DP10, 2009 I zračun masnih pretokov in emitiranih količin plini interna metoda snovi, izmerjenih z metodami pod točkami 2-12, in-house method 14-21 Opombe 1 Notes: V vseh točkah podrobnega obsega akreditacije, pri katerih v rubriki " preskušanja" ni navedenih podatkov, veljajo določila posameznih standardov oziroma nestandardnih preskusnih metod, ki se na to nanašajo. ln all columns of the scope of accreditation where the cel/s under "Range of measurement, testing; Uncertainty of the result of testing" are empty, the provisions of the re/evani standards or non-s shou/d apply. V točkah podrobnega obsega akreditacije, pri katerih sta v rubriki "Oznaka standarda" navedeni dve ali več oznak standardov, se sklic nanaša na v celoti identične standarde. ln those columns of the scope of accreditation where the cel/s under "Reference" specify two or more codes of standards, the complete citation to identical standards should apply. Direktor 1 Director d ~~ // -~./'"" 0805-3 1 * Izdaja 6 Stran 6 od 6