Movement Detector GJD 300

Similar documents
D-Tect 2 GJD300 Quad PIR Movement Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Installation Manual Premier Elite Orbit QD/DT INS483-2

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

DI601AM Outdoor PIR/AM Detector Installation Sheet

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Intrusion Outdoor Protection Perimeter

Description. Optex Incorporated

LUX Hardwired - Installation Notes

Emerald 3000 MK3 GJD010 Lighting Controller

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

English. Series. Installation and Use Manual

PRODUCT GUIDE Electronic Perimeter Detection & High Performance LED Illumination

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

English. Italiano. Português. Françias. Español

Active Infrared Multi Beam Sensors

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Advanced DIGITAL Wired PIR Motion Detector

LPCMPIRM65 & LPCMPIRDSI65

DYGIZONE GJD910 Lighting Controller & Enunciator

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Active Infrared Multi Beam Sensors. R Series

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Sensors. Supplied by: User Interfaces. Networked Controls Product Catalogue

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

"Pegaso" wireless alarm system

HX-80NRAM. High Mount Outdoor Detector

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Hardwired Alarm Accessories

Long-Range Barrier Sensors

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Extended Range DUAL TEC Motion Sensor

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

LS800S Intruder Alarm System. Engineering Manual

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Ceiling PIR HS presence detector. Product Guide. Overview. Features

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

DUAL OPTIC. Installation manual

Wireless security products

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

AT A GLANCE. Product D-TECT2/3/40/50 D-TECTX MKII 30/40/50. Dygi-TECT D-TECT LZR. Elite. Opal RFX. Opal/Mini-Opal D-LITE. Dygizone/Emerald/Sapphire

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

FR-A180 FR-A360. Occupancy detector. Use

Infrared Wall Mount Occupancy Sensor

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

INDEX. Installation recommendation

2G & 3G GSM Wireless Beam Alarm

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Twin Photobeam Detectors Manual

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Infrared Ceiling Mount Sensor

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Installation and Operation Manual

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

DS160/161 Request To Exit PIR sensors Installation Instructions

Reflective Optical Beam Smoke Detector User Guide

P E R I M E T E R m i n i c a t a l o g u e

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Installation Instructions

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Masthead Repeater Installation Handbook

WARNING FIRE DOOR CLOSING

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Transcription:

Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before the detector signals an alarm. This high precision very reliable presence detector has been designed for use within CCTV installations. Programmable parameters include three normally open or normally closed configurations for the two CCTV volt free output relays, as well as a changeover timer, a pulse count feature and a choice of detection ranges from 8 to 30 metres. In addition there are two switched negative outputs. The 'A' output gives a single 400ms trigger every time the detector activates and is generally used in conjunction with the GJD lighting controllers to give 24-hour visual and audible alarm indication. The 'S' output is a photocell-controlled signal giving a fixed 60-second trigger on activation. Additionally independent front and rear tamper circuits are combined to provide a volt free tamper alarm contact. The flexibility of the various outputs and timers allows the to be used in multiple situations without the need for any further customised equipment. The integral dual axis tilt sensor allows 180 of pan and 90 tilt. This increases the speed of the outdoor installation and provides incredibly accurate aiming of the detection pattern. The electronics module is acrylic coated for additional component stability. It is encased in a vandal-resistant high impact zinc alloy housing with a UV stabilised translucent front cover ensuring the sensor is impervious to and unaffected by weather conditions. Additionally the combination of precision electronics, digital white light filter and double shielding eliminates false alarms from the sun and other visible light sources. The design gives a neat and professional appearance with no visible indication of the orientation of the detector head, and totally hides the wiring. 1

D-TECT QUICK INSTALLATION GUIDE Apply supply voltage to the unit, the blue led flashes 3 times The detector takes approximately 2-3 minutes to settle The walk test led is factory set to OFF. Pressing the programme button once will enable the walk test led for 5 minutes. THE FRONT COVER MUST BE FITTED WHEN WALK TESTING FACTORY SETTINGS ARE:- 1 RANGE 20 METRES 2 PULSE COUNT 1 3 LED OFF 4 CCTV1 N/C CCTV2 N/O 5 CONTACT TIMER 5 SECONDS The A and S connections are for use with GJD lighting controllers 2

Stage 1 Mounting the unit Optional for Tamper Cup Cable Holes fig. 1 Template - During installation the electronics must be protected against water, as trapped moisture can affect or damage the unit. 1) Using the template provided drill the wall to accept the two fixing screws, the cable entry and the tamper cup (if used). See fig. 1 and 2. Note: We recommend using the tamper cup on uneven wall surfaces. 2) Remove the cover assembly by loosening the locking screw using the allen key provided. The cover hinges from the top and lifts out of the location slot. See fig. 3. fig. 3 fig. 2 3

Stage 1 Mounting the unit (Cont.) fig. 4 3) Feed standard 12 core alarm cable into the cable entry; bare the wires and connect to the removable terminal block as shown in fig. 7. Screw the unit to the wall ensuring that the tamper pin is correctly located and that the tamper microswitch is closed. See fig. 4 and 5. To aid installation, two spare tamper feet are provided. One is 1mm longer and the other is 2mm longer than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully pulling it from the pin. See fig. 2. 4) Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern. (Refer section titled "Multibeam Alignment & Masking") 5) When the detector has been aligned to suit the installation, replace the front cover and lock as shown. See fig. 6. fig. 6 fig. 5 4

Stage 2 Connecting the Unit NORMALLY CLOSED TAMPER CIRCUIT FRONT + REAR TAMPER CONNECTION 0V SUPPLY TO GJD LIGHTING CONTROLLER TO GJD LIGHTING CONTROLLER 12VDC SUPPLY - A S + ALARM OUTPUT 2 MULTIPLEXER, PTZ DOME, DVR, ETC. CCTV2 CCTV1 ALARM OUTPUT 1 MULTIPLEXER, PTZ DOME, DVR, ETC. fig. 7 fig. 7a Stage 3 Multibeam Alignment & Masking - The GJD multifunction lens fitted to the detector produces 7 long range beams and 7 medium to short range curtain beams. Movement across the beams produces the best response and range, whilst movement towards the detector will be less responsive. The unit detects the changes in heat and movement in the beam pattern, therefore items such as trees, shrubs, ponds, boiler flues and animals should be considered when positioning the detector. - The detector module is fitted with two sliding shutters to reduce the detection angle. An additional set of curtains is provided should the beam pattern need to be narrowed even further e.g. if the minimum detection angle of 10 degrees is required. The curtains are fitted to the pan and tilt module as indicated in fig. 8 below. Each section or the detector's lens gives a coverage pattern of approximately 10 degrees. See fig. 8. 1 2 3 4 fig. 8 5

Stage 3 Multibeam Alignment & Masking (Cont.) - When mounting higher than boundary fences rotate the module and mask off any beams, either vertically or horizontally, that fall outside the area being covered. Use portions of the self-adhesive clear mask supplied to the rear, smooth side, of the lens as shown in the diagrams on the next page. Always replace the lens the correct way up to ensure exact beam pattern coverage (the top of the Fresnel lens is marked - TOP). See fig. 9. MULTIBEAM - OPTIMUM HEIGHT: 3 METRES RANGE: MAXIMUM MODULE TILT: 0 DEGREE MULTIBEAM HEIGHT: RANGE: MODULE TILT: 6 METRES MAXIMUM 9 DEGREE PET IMMUNITY HEIGHT: RANGE: MODULE TILT: 1.5 METRES MAXIMUM -2 DEGREE MASK THIS SECTION OFF FOR PET ALLEY APPLICATIONS UP TO 30 METRES CURTAIN COVERAGE HEIGHT: 6 METRES RANGE: MAXIMUM MODULE TILT: 45 DEGREE MASK THIS SECTION OFF FOR CURTAIN COVERAGE APPLICATIONS 6 Beam Pattern set to maximum range - Masking top section of lens will reduce range to 20 metres Beam Pattern set to minimum range. Masking top section of lens will reduce range to 6 metres 6

Stage3 Multibeam Alignment & Masking (Cont.) fig. 9 Stage 4 Programming - The user can individually programme a number of configurable settings as illustrated in the programming chart. Factory settings are shown as shaded boxes. Changes to the existing settings can easily be made. To reset the factory settings simply remove power form the detector, press and hold the programme button (fig. 10) whilst temporarily applying power to the detector: either before installation, with a PP3 battery, or by applying 12 Volts to the unit on site. fig. 11 fig. 10 Programme Button Blue LED 7

Stage 4 Programming (Cont.) OPTIONS AUX 1 2 3 4 5 6 7 8 RANGE MTRS PULSE COUNT LED 'S' OUTPUT LUX LEVEL CONTACTS TIMER SECONDS PROGRAMMING CHART CCTV 1 CCTV 2 SETTING 1 2 3 4 5 6 7 8 8 1 OFF 2 N/O N/O 2 15 2 ON 5 N/C N/O PRESS 7 TIMES TO FLASH OUT YOUR SELECTED SETTINGS. 5 20 3 10 N/C N/C PRESS 8 TIMES TO RESET THE GJD FACTORY SETTINGS. 10 25 20 20 30 30 30 40 40 50 50 24HR 60 To change any of the settings: - 1) Press the programme button as shown in fig. 10 (or key fob button shown in fig. 11, 12) for the number of the Option to be changed i.e.once for range, twice for pulse count, three times for LED, four times for Lux, five times for contacts & six times for timer. 2) Wait four seconds until the blue LED indicator goes off. 3) The indicator will then flash out the existing setting. 4) To change the setting for that option, press the button the number of times required for the new setting. 5) The indicator blinks twice and the changes are stored. NOTE: When power is applied to the the user has a time slot of 5 minutes to start using the IR keyfob. The timer can be reset by either pushing the program button as shown in fig.10 or by removing and then reapplying power to the 8 ON/OFF fig. 12

Stage 4 Programming (Cont.) Any alterations made to the volatile memory. settings are stored in the detector's non EXAMPLE To change the LED Setting from OFF to ON. 1) Press the programme button three times and release the button. 2) Wait until the indicator goes off. 3) The indicator will now flash once. 4) Press the programme button twice and release the button. 5) The indicator flashes twice showing that the option has been stored and the detector returns to normal operation. Stage 5 Walk Test - The range of the detector increases without the front protective cover. Therefore the front cover must be fitted to establish the correct beam pattern alignment and when testing the outputs. Use the programme table on page 7 to adjust the range as necessary and pan and tilt the lens module over the field of view to obtain the correct coverage area. - When the 'program' button is pressed momentarily the blue indicator lights and pulse count '1' is automatically selected. The unit can then be aligned. The blue indicator will light on the every time a detection takes place. This test mode will automatically cancel five minutes after last detection. Alternatively, remove the power and then re-apply. - If automatic lighting is required to illuminate the area during recording, the connects directly into any of the GJD lighting controllers for simultaneous recording and automatic lighting at dusk. The signals from the detector also provide an audible and visual indication of detection activity 24 hours a day. As the GJD lighting controllers also have a pulse count option, this must be set to '1' on the controller when using the for event recording. 9

Stage 6 OPTION Definitions PULSE COUNT - This is the number of times the unit has to detect on both of its sensors before signalling an output. LED MONITOR LED Off - LED disabled LED On - LED signals a detection LUX SETTING - This is the approximate level that the ambient light must reach before the 'S' output will become active when there is an activation. The 'S' output switches negative for 60 seconds when there is a detection and the light level is below the programmed setting. The 'S' output is an open collector type rated at a maximum of 25 ma. CCTV1 & CCTV2 OUTPUTS - These are magnetically immune volt free relay contacts used to trigger alarm inputs on connected equipment. They can be set to be both normally open, one normally closed and one normally open or both normally closed. TIMER - The timer setting adjusts the time that the relays change state after activation. The contacts are rated at a maximum of 24V AC/DC @ 50 ma. ACCESSORIES GJD is able to supply the following accessories to aid installations: GJD303 GJD304 GJD305 Infra Red key fob programmer Conduit cable entry adaptor ring Pole mount clamp 10

Detection Area Coverage Adjustment Fresnel Lens Customised Optics Outputs No.1 No.2 No.3 No.4 Power input Current Pulse Count Temp. Compensation Control Walk Test Operating Temp. Housing Protection Rating Dimensions Weight Mounting Height Cable < 200m Cable < 500m Technical Specification Programmable between 8 & 30 metres. 10-70 degrees detection angle, 30 m x 30 m coverage max. 180 degree pan + 90 degree tilt Area reduction mask (if required). 28 zones for each Pyro pair, which can be masked with the curtain sliders and special masking tape (supplied). Double silicon shielded quad element eliminates 50,000 lux of white light Silent solid state magnetically immune. CCTV1 CCTV2 Output 'A' Output 'S' 9 to 15 VDC. 9mA (12V nominal). 1-3. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor, selectable N/O & N/C. Adjustable timer options: 2 to 60 seconds. Volt free relay signal contact 24VAC/DC @ 50mA with an integral 25R series resistor, selectable N/O & N/C. Adjustable timer options: 2 to 60 seconds. Open collector negative switching - 25mA max. Alarm period 400ms. Digital sensitivity adjustment. Open collector negative switching - 25mA max. Alarm period: detection + 60 seconds Adjustable: Dusk (2 Lux) to 24 hour. Digital microprocessor - non volatile memory. Output test mode with LED indication. -20 to + 55 Centigrade Conformally coated electronics for increased stability. High impact zinc alloy. IP 55. 145 x 120 x 115 mm. 750grams NET, 880grams GROSS. Variable up to 6 metres - optimum height 3 metres. Uitlising all five outputs (incl. tamper) - 12 core 7/0.2mm. Utilising all five outputs (incl. tamper) - 12 core 16/0.2mm. CE Mark GJD reserve the right to amend specifications without prior notice. GJD Manufacturing Limited Unit 2, Birch Industrial Estate, Whittle Lane, Heywood, OL10 2SX, UK Tel: Sales +44 (0) 1706 363998 Technical: +44 (0) 1706 363990 Fax: +44 (0) 1706 363991 E-mail: info@gjd.co.uk Web: www.gjd.co.uk 12