Emerald 3000 MK3 GJD010 Lighting Controller

Similar documents
DYGIZONE GJD910 Lighting Controller & Enunciator

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Movement Detector GJD 300

D-Tect 2 GJD300 Quad PIR Movement Detector

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Intelligent Security & Fire Ltd

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Conventional Fire Alarm System 2014 V1.2

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

HG Home Guardian Advanced Home Energy, Safety and Security Management

Alarm Tone Generator Model AG17

Intruder - Fire - Water Combined Alarm

STANDARD FEATURES SPECIFICATIONS

Conventional Leaflets

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Excel-EN Conventional Fire Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

WARNING FIRE DOOR CLOSING

User Operation Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LS800S Intruder Alarm System. Engineering Manual

5 Sounds and Indications

TECHNICAL DATA OBSOLETE

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Scantronic Leading the way in security

OPERATION AND INSTALLATION MANUAL

CORNELL Emergency Response Systems

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Intelligent Security & Fire Ltd

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Door Release Power Supply

SECURIT 700L PLUS ENGINEERING MANUAL

USER MANUAL CEF AP28 CONTROL PANEL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Conventional Smoke Detectors KFAPO

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Application, Installation, Operation & Maintenance Manual

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

FireNET Plus Wiring Instructions

LUX Hardwired - Installation Notes

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PRODUCT GUIDE Electronic Perimeter Detection & High Performance LED Illumination

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Power Supply Display Module PSDM. Installation and Operation Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating Instructions

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

FPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

TrueAlarm ES Analog Sensing

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Addressable and Conventional Fire Protection

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

AO Annunciator Module

AL800ULADA. NAC Power Extender. Installation Guide

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

D-TECT 2 IP. GJD230 IP Motion Detector

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Conventional Fire Detection

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

P1195 DUAL TOURNIQUET MONITOR

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Water Detection Controllers

C106 Coded Access Keypad

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

MODEL 5100 VOTING LOGIC MODULE

Transcription:

Emerald 3000 MK3 GJD010 Lighting Controller SPECIFICATION SUPPLY: 230 Vac 50Hz via ELCB/MCB - unit fused at 13A 12VDC@ 100mA: GJD Opal XL (6mA) or Elite Detectors (10mA) Optional external 12VDC piezo sounder up to 50mA The GJD Emerald is a dual area security lighting controller which enables external areas to be accurately monitored. It automatically switches up to 3000 Watts of resistive lighting at night for a pre-set period can be manually overridden when required. The controller incorporates an audible warning tone and features six detector indicators which illuminate when activated by detection day and night. LOAD: Each expansion unit switches two channels each up to 1500W of resistive load or 1000 Watts of inductive load. The inductive load may require a snubber (suppressor) to manage the lamp discharge current. INDICATION: Six 24 hour detector indicators which pulse during detection and are steady after detection for the duration of the light on timer setting. AUDIBLE: Internal warning tone which sounds on detection day and night, and is button selectable. It has a steady tone for zone one and pulsed tone for zone two. CONTROL: Controls up to 12 x GJD detectors. Switches two independent areas of lighting with manual override when required. OPTIONS: Ability to link both lighting areas together. Ability to have a time auxiliary output. Ability to active lighting when linked to an intruder alarm panel. DIMENSIONS: 146(W) x 86(H) x 56(D) mm 507gm Weight MOUNTING: Indoor use only. Mount in a clean dry location on a secure flat surface. TEMPERATURE: -10 to +55 Centigrade Self contained - Class 2 independently mounted control -1-

OPERATING INSTRUCTIONS When a detector is activated day or night the relevant detector indicator flickers and will remain on for the length of the timer setting. During darkness the lighting will be switched on automatically while the detector is receiving activation signals, and will automatically turn off after the pre-set timer period. ADJUSTMENT TO FACTORY SETTINGS: When connecting the unit to the electrical supply or when the supply is interrupted, the indicators will flash for one minute whilst the system settles. Pressing any button during this time will start normal operation. The Zone 1 and Zone 2 green indicator have to be selected for automatically controlled lighting on detection during darkness. Green indicator is on. This mode must be selected for automatic lighting during darkness. Indicator off. Lighting and tone are switch off for this zone. Green indicator flashing. A detector has activated the lighting. Manually selecting this yellow indicator will turn the lighting on. Turning the indicator off will return to automatic mode. Indicator off. Yellow indicator flashing. A detection has automatically activated the lighting. Red indicator on. Audible warning tone selected. Zone 1 and/or Zone 2 indicator to be selected to function. Indicator off Audible warning tone is switched off. Internal adjustments panel The factory settings are shown. AUX - Auxiliary Output (50mA maximum) OFF - Internal sounder and auxiliary output disabled STD -Internal sounds and auxiliary output active and will emit a warning tone on each detection when the tone button is selected. 10-30 Seconds - The auxiliary output time after last detection. The internal sounder is as the STD Light on time in minutes 1 to 24 minutes - The length of the time after last detection during darkness. The red detector indicators will stay on for this time after the last detection day and night. Pulse Count / Walk Test - Select the symbol to assist in location/alignment of the detector beams during daylight installations. When the detector beams are activated the external lights will stay on for a period of 6 seconds. 1,2 or 3 - Activated completing the walk test function, set the pulse count to the required level. The pulse count is the number of detector beams that have to be crossed to trigger the system. 1. will give fast response 2. gives better immunity with good response 3. gives highest immunity to false activation in poor environments but is less responsive. -2-

CAUTION: To be installed by qualified personnel only: 1. Link both lighting areas together ( except in walk test) connect LINK to -. 2. Remote triggering of lights for the timer period. Pulse Count 1 must be selected. 3. Activate zone lighting for alarm period when linked to an intruder alarm panel. All diodes: IN4148, IN4002 etc. -3-

EXCHANGING EMERALD 3000 WITH AND EMERALD MK3 If it becomes necessary to exchange an original Emerald 3000 (DX10) lighting controller with an Emerald MK3 lighting controller then the following connection changes need to be applied. 230 Volt A.C Connections Emerald 3000 (DX10) EMERALD MK3 LIVE LIVE LIGHT A LOAD 1 LIGHT B LOAD 2 NEUTRAL N 12 Volt D.C Connections S1 S2 S3 S4 S5 S6 AA AB - A1,A2, OR A3 ZONE1 A1, A2 OR A3 ZONE2 AUX -4-

Engineer Notes Technical: 01706 363990 Sales: 01706 363998 Fax: 01706 363991 Email: info@gjd.co.uk Unit 2, Birch Business Park, Whittle,Lane,Heywood,OL10 2SX