GAS DUCTED HEATER TB SERIES

Similar documents
Spectrolink Comfort Controller. Home Owner's Manual Heating. baby, outside. Come home to ECOST R

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller)

Important safety information

LAYOUT BRAEMAR ECOSTAR GAS SPACE HEATER AND WALL FURNACE OPERATING INSTRUCTIONS FOR MODELS SH18, SH25 AND WF25 HEATED AIR OUTLET HEATER CONTROL PANEL

Spectrolink Comfort Control. Home Owner's Manual Heating

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

Rapid Response Series (RR e & RR i) OPERATING MANUAL

Auto Drain Installation Instructions.

HOME OWNER S MANUAL DUCTED GAS HEATER. (with MagIQtouch Controller or Manual Thermostat)

Service Manual. Brivis StarPro SP4, SP5 & SP6

SHAMIC SHEETMETAL (AUST.) PTY. LTD.

Auto Drain Installation Instructions.

Rinnai. Rinnai GAS SPACE HEATERS. Convector 417 Unflued Room Heater CUSTOMER S OPERATING INFORMATION AND INSTALLATION INSTRUCTIONS

OWNERS INSTRUCTION MANUAL FOR FIXED INSTALLATION COMMERCIAL AND RESIDENTIAL EVAPORATIVE AIR CONDITIONERS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

When you have a Bonaire ducted gas heater installed, you won t know it is winter until you look out the window Ducted Gas Heating Range

LANDSCAPE BALANCED FLUE SPACE HEATER

LANDSCAPE BALANCED FLUE SPACE HEATER

omega C L I M A T E S Y S T E M S Simply the best!

GAS COOKTOPS INSTALLATION INSTRUCTIONS. Model numbers ICBCG15 ICBCG304 ICBCG365

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Ducted Gas Heating. The effective way to heat your whole home

Technical Manual MAY 2008 Edition

Area Heater AH100 Series

User Manual. 600mm, 700mm & 900mm Gas Cooktops Model No. CF6GS, CF6GW, CF7GS, CF9GS

Brivis Inverter Icebox

Wok Cookers Instruction Manual

G34M Bulletin #69/ August 2003

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Exhaust Duct Design Page 1 of (C)

Operation & Installation Manual

Ducted Gas Heating. The effective way to heat your whole home

OWNER S MANUAL. CPL Evaporative Cooler. (English) (CPL) ILL1456-A

Packaged Gas/Electric

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

Operation & Installation Manual

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Manual. Monaco. Gas Fires. Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

New Zealand Sales Hotline: Sales Fax:

Pizza Oven with Stand

Energysaver Space Heaters Models: RHFE-309FT & RHFE-559FT Operation and Installation Manual

MODELS: RDV3610ETR, RDV3611ETR

THE INSTRUCTIONS IN THIS MANUAL APPLY TO MASPORT BOSTON (Flued) AND CALGARY (Flueless) GAS FIRES.

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

CERT 7795 Fully certified to AS2658:2008. Part No. COMP825 OWNERS MANUAL

Australian Indoor Flue Installation Instructions Vertical Termination Flue Kits for Universal H-Series (Forced-Draft) Heaters

OWNER S MANUAL. SACC Series Add-On Cooling Unit. (English) (SACC)

Gas Range Static Oven

RPA. Installation. Operation. Service INDUSTRIAL EVAPORATIVE AIR CONDITIONERS. January 09

VULCAN GAS RANGES RG-6 OPEN BURNER

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Owners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

INSTALLATION GUIDE NZ AU D

Outdoor Tabletop Heater TTH20 Series

Brivis Compact Classic Ducted Gas Heater

HEATING. Owner s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE. Bonus offer when you register your product online brivis.com.au.

OWNER S MANUAL. Evaporative Cooler. Original English Instructions. (English) (LCB, CPL, CPS, BM)

THE INSTRUCTIONS IN THIS MANUAL APPLY TO KENT GAS FIRES. CONTENTS:-

Heat your whole home in just 10 minutes!

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

INSTALLATION & OPERATING MANUAL

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Gas Range Static Oven

Brivis Service Manual BX3 Buffalo Gas Ducted Heater

Brivis Classic Ducted Gas Heater

WITH OMRON E5CC CONTROL

Hurlcon Gas Fired Hot Water Boiler H120 & H150 S & B Models

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Setting the Timer...

Brivis Classic Ducted Gas Heater

Safety / Kit Components 1

Patio Heater Model No. GM and GM

4111 Cab Parking Heater Affects: Related:

MPS OWNERS MANUAL. To all new customers buying a Brivis product for the first time, welcome!

OPERATING INSTRUCTIONS

CONTENTS. Welcome to Think Letter page 3. General Information page 4-5. Warning and Safety Instructions page 5-6. Instructions for Use pages 7 10

RHEEM CONTINUOUS FLOW GAS HOT WATER YEAR WARRANTY ENERGY L/MIN GAS HOT WATER THAT NEVER RUNS OUT. factor COMES ON STEADY, HOT AND STRONG INSTALL A

INSTALLATION INSTRUCTIONS

OWNER S MANUAL. Evaporative Cooler. (English) (EXH, EZH) ILL239-D ILL1140-A FAN SPEED REMOTE CONTROL ECONOMY

Using the. Ducted Gas Central Heating Dual Cycle Refrigerated Air Conditioning Ducted Evaporative Air Conditioning. with your.

Wall Mounted Radiant Gas Heater

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

USER MANUAL GHR16S, GHR16W, GHR17S, GHR17W, GHR765S, GHR775S, GHR95S, GHR95W, GHR795S GAS COOKTOPS

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS

Elegance. SMT-700 User manual. Ver

Airflow. Add a little Sunshine to your bathroom

Split System Air Conditioning

Gas Continuous Flow Hot Water System User Manual

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

KADO LUX LED EXHAUST FAN 200

Outdoor Radiant Gas Heater

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Natural gas safety tips. Help us keep you safe

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Owner s Information Manual

OPERATING INSTRUCTIONS

Transcription:

GAS DUCTED HEATER TB SERIES Home Owners Guide APRIL 2002

N837 FROM YOUR LOCAL GAS SUPPLIER XXX MJ/m 3 PER YEAR Part No... 9601055 INTRODUCTION Congratulations on choosing a Braemar Gas Ducted Heating Unit. Your Braemar Heater is built from the highest quality materials and is engineered to provide many years of trouble free performance. Please take a moment to read these instructions. Delivery The customer or installer, upon delivery of the heater should ensure that the model number and gas type is as requested. A data label on the end of the heater details both the model number and gas type. Please check the heater and report any freight damage. Features 1. Heat exchanger - 10 year warranty 2. Fully automatic electronic ignition 3. Approved by the Australian Gas Association 4. Extra Air Models - TBX GAS DUCTED HEATER TB / TE / TX SERIES TE Gas Ducted Heater GENERAL Alternative Flue Location AIR OUT Gas in Combustion Air Intake Louvres Side Panel Splits along this line to give LH and RH operation. Mains In & T/Stat Standard 100mm Flue Outlet AIR IN TE Gas Ducted Heater PRODUCTION LABEL AGA MAKERS WARRANTY BADGE L ighting I nstructions 1. Set Room Thermostat to Below Temperature. 2. Turn GasTap and Power ON. 3. Set Room Thermostat to aboveroomtemperature. 4. TheHeater is nowin Automatic Mode. After about 30 secondsthe Room Fan will comeon. 5. Set the RoomThermostat to the desired Comfort Level. SPECIFICATIONS Gas Rate MJ ( nom ) 65 90 120 Gas Pressure Nat. kpa.87.87.87 LPG kpa 2.75 2.75 2.75 Injector Size - Nat - mm 2.20 2.20 2.20 -LPG- mm 1.30 1.30 1.30 Airflow @100 Pa L/sec 420 540 790 Nominal Temp Rise - oc 30 30 30 Operating Voltage 240 240 240 Fan Motor Size - Watts 315 315 315 Max Current - Amps 3.0 3.0 6.0 Manufactured by Seeley International 77 North St Albury NSW 2640 Warranty & Service 1 300 650644 Technical Support 1 300650399 Electrical Approval to AS 3100 AGA APPROVAL No. 5904! DO NOT Operate this appliance before reading the DO NOT Place articles on or against this appliance DO NOT Store chemicals, flammable materials or spray DO NOT Operate with panels, covers or guards removed instruction booklet aerosols near this appliance. from this appliance. FOR I NSTALLATIONINDOORSONLY TO BE I NSTALLED BY AN AUTHORISED PE RSON ONLY GA S ENERGY RA TING USE THIS LABELTOCOMPARE DIFFERENT MODEL CENTRAL HEATERS COM PARATIV E EN ERGY CON SUM PTION THIS BRAEMARTB65, TB90, TB120 USED WHENTESTEDTOAUSTRALIANGASCODEAG106 ACTUAL ENERGYUSEDWILL DEPENDONWHEREYOULIVE ANDHOWTHE APPLIANCEISUSED APPLIANCE RUNNING COST INFORMATION IS AVAILABLE Heater Data Label ill0001tb Designed and manufactured in Australia to exacting standards. 1

TURNING THE HEATER ON FOR THE FIRST TIME Simply follow the steps below. 1. Ensure the gas tap at the heater is turned on. 2. Turn the Thermostat to the ON Position. Refer to the instruction sheet in the thermostat package. 3. Set the Thermostat to above the room temperature. 4. The heater is now in automatic mode. The combustion fan will start. After 15 seconds the sparker will commence to spark. As soon as the heater lights the sparker will stop. ( it will normally take only 1 or 2 sparks for the heater to light ) After a short period of time, the room fan will commence to blow warm air through the vents. 5. Set the room thermostat to the desired temperature. When desired room temperature is reached the gas and combustion fan will turn off. The room fan will continue to run ( about 2 minutes ) to extract all the heat from the heat exchanger. MAINTENANCE SCHEDULE Periodic maintenance of the heater will ensure a long and satisfactory service life with the heater operating at optimum performance. Maintenance should be performed on a yearly basis by an Authorised person trained in the service of the Braemar Heaters. If heater does not operate satisfactorily refer to the trouble shooting chart at the rear of this book or contact your Braemar Dealer. 2

TROUBLE SHOOTING If you have difficulty operating your Heater check the trouble shooting guide before calling for service HEAT Should be ON but the heater is not working. Turn the thermostat to the off position, wait 5 seconds set the thermostat temperature to above room temperature. The heater should now operate. Heater is not operating effectively. Check that there are enough outlets opened for the fan speed selected. Is the return air filter blocked? We recommend cleaning every fortnight. Not enough Heating. Is the thermostat located in the correct area according to the Installation Instructions. Increase the SET temperature. Heater runs when not programmed - Electronic thermostats. Check the time AM or PM. Sleep or away programmed temperature is too high: lower. FOR SERVICE CALL : 1 300 650 644 3

IMPORTANT Record the Serial No. and Model No. of the heater here. Model No: Serial No: Date of Installation: / / Installer: SERVICE Before calling for service have you: 1. Checked through the trouble shooting guide. 2. Noted the Serial No. & Model No. of the heater. ( if they are not recorded above, the numbers are located on the side of the heater. ) 3. Spoken to your Braemar Dealer / Installer. FOR SERVICE CALL : 1 300 650 644

SERVICE: 1300 650 644 For all your Braemar warranty and service needs. Or Contact your local Braemar direct dealer. TECHNICAL SUPPORT CENTRE: 1300 650 399 For technical support regarding the installation of this product SALES: 1300 650 141 For all your sales enquiries Seeley International Pty Ltd has a policy of continuous product development and therefore reserves the right to make changes to these specifications without notice. Whilst every care has been taken to assure accuracy of the data compiled in the document, Seeley International Pty Ltd does not assume any liability for errors and/or omissions. Braemar is a registered trademark of Braemar Industries Pty Ltd. Seeley International Pty Ltd ACN 23 054 687 035 Albury Manufacturing 77 North Street Albury, NSW 2640 xref0091 August 04 www.seeley.com.au Manufacturers and Designers of Technically Advanced Quality Heating and Cooling Products ECN1100 Doc. No. 613949 /c Specialty Press