Dosimetric verification of intensity modulated radiation therapy

Similar documents
The development of a plastic scintillator for radiotherapy dosimetry

Small-segment intensity modulated radiation therapy dosimetry with various ion detectors and Gafchromic EBT2 film

Urethral alarm probe for permanent prostate implants

Co-60 irradiator for therapy level calibrations at SSDLs

An investigation of the reproducibility and usefulness of automatic couch motion in complex radiation therapy techniques

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Monitoring of Radiation Exposure Adjacent to a Linear Accelerator Treatment Bunker with a Highlight Window

TABLE OF CONTENTS. iii iv vi. vii. xii xiii xvii xix

MapCHECK 3. The New Benchmark for 2D IMRT QA. Your Most Valuable QA and Dosimetry Tools

Independent validation of machine performance check for the Halcyon and TrueBeam linacs for daily quality assurance

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

Victoreen & 660-8

Development and demonstration of a diode laser sensor for a scramjet combustor

University of Pennsylvania. Environmental Health and Radiation Safety (EHRS) X-ray Diffraction User Guide

Measuring Couch Motion Accuracy with X-ray Beam Fluence

INSTRUMENTATION AND CONTROL TECHNICIAN TRADE REGULATION

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

SIMULATION OF THERMAL SYSTEMS

Dosimetry issues related to the SSRT project at the ESRF

Fire Protection Systems FST 209. COURSE SYLLABUS Fire Protection Systems FST 209 [Semester] CRN 3 Credits

Dosimetry for the MR-linac

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

COMMISSION REGULATION (EU) / of

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

Forward-scattered radiation from the compression paddle should be considered when average (or mean) glandular dose is estimated

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

Assessment and management of radiotherapy beam intersections with the treatment couch

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools

Injection with front ends open at the ESRF

Radiation Emitting Devices Research X-ray Safety Program

Dual-Diode Dosimeter Patient Dose Monitor

Reference Dosimetry of High-Energy Therapy Photon Beams with Ionisation Chambers. Recommendations No. 8, Revision 2018

Written as per the revised syllabus prescribed by the Maharashtra State Board of Secondary and Higher Secondary Education, Pune.

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

HUMIDITY CONTROL SYSTEM FOR ROLLING AND FERMENTING ROOM OF A TEA FACTORY

Characterization of dose impact on IMRT and VMAT from couch attenuation for two Varian couches

ESSENTIAL REQUIREMENTS CHECK LIST

CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE

UNIVERSITI TEKNOLOGI MARA

COMMISSIONING OF THE DOSE DELIVERY SYSTEM AT MEDAUSTRON

CONTEXT OF THIS AFRIKAANS PROTESTANT CHURCH

Crown Boiler Company

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

Required Materials For complete material(s) information, refer to

Beam Loss Position Monitoring with Optical Fibres at DELTA

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

Product Solutions Your Most Valuable QA & Dosimetry Tools

The Influence of Graphics on Contemporary Commercial Interiors in Sri Lanka. library UNIVERSITY OF MORATUWA, SRI LANKA MORATUWA

Optical Measurement Techniques for LED Clusters and LED Safety

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

Liquid Ring Vacuum Pumps, Compressors and Systems

Safety Best Practices Manual

Generation and verification of QFix kvue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2

Analytical X-Ray Safety Program

UNIVERSITI TEKNOLOGI MARA EFFECTIVENESS OF VESICULAR ARBUSCULAR MYCORRHIZA ON ROOT DEVELOPMENT OF SAGO PALM PLANTLETS

UNIVERSITI TEKNOLOGI MARA IMPLICATION OF NIGHT-TIME LEISURE ACTIVITIES TOWARDS PLACE IDENTITY OF URBAN PUBLIC PARK IN SHAH ALAM AND PUTRAJAYA

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Active Scanning Beam 2: Controlling Delivery

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Courthouse East vision and policy plan

Determination of the photon beam attenuation by the BrainLAB imaging couch: angular and field size dependence

THE LEEDS TEST OBJECTS NEWSLETTER FEBRUARY 2011

RESPIRABLE CRYSTALLINE SILICA PARAGRAPHS (C) THROUGH (J)

SAN DIEGO COMMUNITY COLLEGE DISTRICT MIRAMAR COLLEGE ASSOCIATE DEGREE COURSE OUTLINE

VIGOUR OF FUNGICIDE-TREATED AND UNTREATED MAIZE SEED FOLLOWING STORAGE VELOSHINIE GOVENDER

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) Environmental and Occupational Health and Safety Manual

RADIATION CONTROL GUIDE

EMIRATES AUTHORITY FOR STANDARDIZATION AND METROLOGY (ESMA) Draft UAE.S :2016

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

West Virginia University Laser Safety Program

OSHA Table 1

WG Container & Cargo X-Ray Scanning Portal

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

PUBLIC HEARING May 18, 2010 SUMMARY AND RECOMMENDATION

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Technical Information OUSAF12

Procedure for the Approval of New Fire Detection and Alarm Technologies

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

THE A.A.B. COMPANY 615 McCallie Avenue Chattanooga, TN

EXPERIMENTAL DETERMINATION OF BEAM QUALITY CORRECTION FACTORS IN CLINICAL HIGH-ENERGY PHOTON AND ELECTRON BEAMS

Recent BRANZFIRE enhancements and validation

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

Loss Prevention Standard

INTERNATIONAL STANDARD

Specified Exposure Control Methods When Working With Materials Containing Crystalline Silica

WG Entire Truck & Cargo X-Ray Scanning Portal

Doctoral Dissertation. Energy-saving Modifications Through Passive Cooling for Urban Houses in Hot-humid Climate of Malaysia

Australian Standard. Methods for fire tests on building materials, components and structures

CBI-064. User Manual. Caddx to KNX-BUS Interface

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines. for Safety Systems at Radiation Treatment Centres

VERIFICATION OF IONISING RADIATION MONITORS FOR PRACTICAL USE IN HOSPITALS. C. Montes, F. Sáez, C. Martín, P. Collado, C. J. Sanz, E.

Laser Institute of America. Laser Safety Guide. Eleventh Edition Prepared by LIA Laser Safety Committee

Transcription:

University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2005 Dosimetric verification of intensity modulated radiation therapy Alison Chapman University of Wollongong Recommended Citation Chapman, Alison, Dosimetric verification of intensity modulated radiation therapy, MSc thesis, Department of Engineering Physics, University of Wollongong, 2005. http://ro.uow.edu.au/theses/551 Research Online is the open access institutional repository for the University of Wollongong. For further information contact the UOW Library: research-pubs@uow.edu.au

NOTE This online version of the thesis may have different page formatting and pagination from the paper copy held in the University of Wollongong Library. UNIVERSITY OF WOLLONGONG COPYRIGHT WARNING You may print or download ONE copy of this document for the purpose of your own research or study. The University does not authorise you to copy, communicate or otherwise make available electronically to any other person any copyright material contained on this site. You are reminded of the following: Copyright owners are entitled to take legal action against persons who infringe their copyright. A reproduction of material that is protected by copyright may be a copyright infringement. A court may impose penalties and award damages in relation to offences and infringements relating to copyright material. Higher penalties may apply, and higher damages may be awarded, for offences and infringements involving the conversion of material into digital or electronic form.

DOSIMETRIC VERIFICATION OF INTENSITY MODULATED RADIATION THERAPY A thesis submitted in fulfilment of the requirements for the award of the degree Master of Science - Research from University of Wollongong by Alison Chapman, B Med Rad Phys (Honours) Department of Engineering Physics 2005

Certification I, Alison Chapman, declare that this thesis, submitted in fulfilment of the requirements for the award of Master of Science - Research, in the Department of Engineering Physics, University of Wollongong, is wholly my own work unless otherwise referenced or acknowledged. The document has not been submitted for qualifications at any other academic institution. Alison Chapman 22/05/06

Acknowledgement I would like to thank many people who have helped with this project, including my supervisors Prof Peter Metcalfe and Prof Anatoly Rosenfeld, the staff at the Illawarra Cancer Care Centre, the physics staff at St George Cancer Care Centre, my parents Ken and Judy Chapman, and Mark Bradley for their constant support and commitment. ii

Abstract Intensity modulated radiation therapy (IMRT) is a relatively new treatment planning and delivery technique. The complex multiple-segment nature of an IMRT plan makes it difficult to verify using traditional look-up tables and hand calculations. The purpose of this project was to develop an effective and time-efficient plan checking procedure using a combination of ionisation chambers and film. The dosimeters available were 0.03 cc volume and 0.6 cc volume thimble ionisation chambers, Kodak X-Omat V (XV) film and Kodak Extended Dose Range (EDR2) film. First the dosimeters were tested for accuracy in terms of their dose response in the clinical range required (up to about 200 cgy). All were found to be suitable for further investigation for use in IMRT plan checking. One non-imrt and six IMRT plans were validated. The plans were transferred from the patient geometry to a 30 cm x 30 cm x 30 cm cubic phantom made up of slabs of solid water. The ionisation chambers and films were calibrated and used to measure the dose delivered to the phantom at the isocentre for each beam and for an entire IMRT treatment. The film was also used to provide axial and planar dose distribution maps for comparison with the predicted distributions. Time restraints meant that not every type of dosimeter was used for every beam and treatment plan. It was found that the isocentric 0.6 cc volume ionisation chamber provided a suitably accurate dose check, with an average difference between predicted and measured full treatment doses of 2.0 cgy with a standard deviation of 2.7 cgy and 1.5% with a standard deviation of 2.1%. The film was less successful, with the EDR2 film (digitised and analysed using ImageJ software) giving an average difference between predicted and measured full treatment doses of 5.4 cgy with a standard deviation of 4.0 cgy and 4.0% iii

with a standard deviation of 3.1%. The film was very useful for obtaining qualitative dose distribution maps, which could be used as surrogates to verify that the radiotherapy treatment planning system s co-ordinate information was being transferred correctly. Following the results of the test cases a procedure was established for all future IMRT plans. The procedure can easily be varied to include further measurements if necessary, and consists of measuring the dose at isocentre from each beam and the whole treatment using the 0.6 cc ionisation chamber. EDR2 film is to be used to visually verify the axial dose distribution, and XV film to verify planar dose distributions for each beam. iv

Contents List of Figures... x List of Tables... xvi Abbreviations... xx Chapter 1: Introduction 1.1 Project Aims... 1 1.2 Cancer and Radiotherapy... 2 1.2.1 Cancer... 2 1.2.2 Radiotherapy... 5 1.3 Radiation Interactions - Clinical IMRT Sites... 7 1.3.1 Lacrimal Gland... 8 1.3.2 Parotid... 10 1.4 Dosimetry Validation... 12 1.4.1 Quality Assurance... 12 Chapter 2: Literature Review 2.1 IMRT Delivery Methods... 15 2.1.1 Matchlines... 19 2.1.2 Tongue and Groove Effect... 20 2.2 Planning... 21 2.2.1 Radiotherapy Planning Computer... 21 2.2.2 Conventional Planning... 24 2.2.3 Convolution Calculations... 25 2.2.4 Inverse Planning... 26 2.2.5 Plan Verification... 28 v

Chapter 3: Materials and Methods 3.1 Planning Computer... 30 3.2 Treatment Delivery... 32 3.2.1 Linear Accelerators... 32 3.2.2 Radiation Interactions from Linear Accelerators... 38 3.2.3 Conversion of Monitor Units... 41 3.2.4 Multileaf Collimator... 43 3.3 Verification Dosimetry... 48 3.3.1 Ionisation Chambers... 49 3.3.2 Electrometers... 53 3.3.3 Film... 55 3.3.4 Kodak X-Omat V... 61 3.3.5 Kodak EDR2... 62 3.3.6 Dosimetry Phantoms... 64 3.3.7 Vidar Film Scanner... 67 Chapter 4: Ionisation Chamber Tests 4.1 Aim - Ionisation Chamber Tests... 70 4.2 Method - Ionisation Chamber Tests... 73 4.2.1 Method - Ionisation Chamber Set-Up... 73 4.2.2 Method - Ionisation Chamber Dose Measurements... 76 4.3 Results - Ionisation Chamber Tests... 78 4.3.1 Results - Effective Point of Measurement... 79 4.3.2 Results - Regular Ionisation Chamber Calibration... 81 4.3.3 Results - Small Ionisation Chamber Calibration... 88 4.3.4 Results - Ionisation Chamber Volume Comparison... 95 vi

4.3.5 Results - Small Field Dose Profiles... 98 4.4 Conclusion - Ionisation Chamber Tests... 102 Chapter 5: Film Tests 5.1 Aim - Film Tests... 104 5.1.1 Aim - Step Film Tests... 105 5.1.2 Aim - Film Orientation Tests... 106 5.1.3 Aim - Film Dose Response Tests... 108 5.1.4 Aim - Film Scanner Tests... 109 5.2 Method - Film Tests... 110 5.2.1 Method - Film Preparation... 110 5.2.2 Method - Film Exposure... 111 5.2.3 Method - Scanner Tests... 114 5.2.4 Method - Step Film Tests... 116 5.3 Results - Film Tests... 117 5.3.1 Results - Osiris and ImageJ Software... 117 5.3.2 Results - Step Film Tests... 122 5.3.3 Results - Film Measurements... 126 5.3.4 Results - EDR2 Film Set-Up Tests... 127 5.3.5 Results - XV Film Calibration... 135 5.3.6 Results - EDR2 Film Calibration... 138 5.3.7 Results - Scanner Exposure Tests... 141 5.3.8 Results - Scanner Resolution Tests... 143 5.4 Conclusion - Film Tests... 145 Chapter 6: Patient Dosimetry vii

6.1 Aim - Patient Dosimetry... 147 6.2 Method - Patient Dosimetry... 148 6.2.1 Method - Ionisation Chamber Calibration... 148 6.2.2 Method - Ionisation Chamber Zero Gantry Angle Measurements... 150 6.2.3 Method - Film Calibration... 151 6.2.4 Method - Film Axial Cross-Section Measurements... 152 6.2.5 Method - Film Planar Measurements... 153 6.3 Case 1 Dosimetry... 154 6.3.1 Aim - Case 1... 154 6.3.2 Method - Case 1... 154 6.3.3 Results - Case 1... 155 6.3.4 Conclusion - Case 1... 162 6.4 Case 2 Dosimetry... 163 6.4.1 Aim - Case 2... 163 6.4.2 Method - Case 2... 163 6.4.3 Results - Case 2... 164 6.4.4 Conclusion - Case 2... 173 6.5 Case 3 Dosimetry... 174 6.5.1 Aim - Case 3... 174 6.5.2 Method - Case 3... 174 6.5.3 Results - Case 3... 175 6.5.4 Conclusion - Case 3... 184 6.6 Case 4 Dosimetry... 186 6.6.1 Aim - Case 4... 186 viii

6.6.2 Method - Case 4... 187 6.6.3 Results - Case 4... 188 6.6.4 Conclusion - Case 4... 194 6.7 Case 4 Boost Dosimetry... 195 6.7.1 Aim - Case 4 Boost... 195 6.7.2 Method - Case 4 Boost... 195 6.7.3 Results - Case 4 Boost... 196 6.7.4 Conclusion - Case 4 Boost... 201 6.8 Case 5 Dosimetry... 202 6.8.1 Aim - Case 5... 202 6.8.2 Method - Case 5... 202 6.8.3 Results - Case 5... 202 6.8.4 Conclusion - Case 5... 207 6.9 Case 6 Dosimetry... 208 6.9.1 Aim - Case 6... 208 6.9.2 Method - Case 6... 208 6.9.3 Results - Case 6... 209 6.9.4 Conclusion - Case 6... 215 Chapter 7: IMRT Dosimetry Conclusion 7.1 IMRT Dosimetry... 216 References... 245 ix

List of Figures 1.1 Normal cell structure compared to cancer formation, which is forcing normal cells out of the way... 2 1.2 The defined treatment volume. The IV would surround the TV... 6 1.3 Diagram of the eye showing the position of the lacrimal gland... 8 1.4 Diagram showing the position of the parotid glands... 10 2.1 The tongue and groove underdosage effect from a three-segment IMRT sequence. The line indicates the regions of underdosage (courtesy of Peter Hoban and Peter Metcalfe, private communication, 2004)... 20 2.2 Example of isodose curves in a depth dose distribution... 22 2.3 An example of the DVH that was created to evaluate Case 2 plan... 23 3.1 A linear accelerator similar to that used for the IMRT deliveries, showing the treatment couch in the bottom left corner, the rotating gantry, and the stand behind... 32 3.2 A control room at ICCC, showing the various monitors, computers, and keyboards necessary to control the linear accelerator... 33 3.3 The major components of a linear accelerator... 34 3.4 The bending magnet and beam shaping components of a linear accelerator... 35 xi

3.5 A schematic diagram of linear accelerator monitor ionisation chambers, the second chamber set at right angles to the first... 37 3.6 Schematic of the photoelectric effect... 39 3.7 Schematic of Compton scattering... 39 3.8 Schematic of pair production... 40 3.9 The treatment head of a linear accelerator, showing the MLC... 44 3.10 The electrometer and small ionisation chamber used for the dose measurements... 49 3.11 The regular NE 2571 Farmer ionisation chamber used for dose measurements... 50 3.12 The small IC 10 ionisation chamber used for dose measurements... 51 3.13 A schematic of an electrometer... 53 3.14 The layers of film: protective coating A; film emulsion B; subbing layer C; film base D... 55 3.15 A digitised section of the step film used... 57 3.16 The cubic solid water phantom used in this project... 65 3.17 The Vidar VXR-12 film scanner... 67 xii

4.1 The set-up of the ionisation chamber in the solid water phantom with the beam incident perpendicular to the axis of the chamber... 74 4.2 The set-up of the ionisation chamber in the solid water phantom with the beam incident parallel to the axis of the chamber... 75 4.3 Results for calibration of the regular ionisation chamber in all set-ups... 86 4.4 Results for calibration of the small ionisation chamber in all set-ups... 93 4.5 Results for the regular and small ionisation chambers, normalised to 1.0, perpendicular orientation at 15 cm depth... 97 4.6 Results for the small chamber, CC 01 chamber and XV film dose profile measurements at 1.5 cm depth...99 4.7 Results for the small chamber and CC 01 chamber dose profile measurements at 10 cm depth... 100 4.8 Results for the small chamber and CC 01 chamber dose profile measurements at 20 cm depth... 101 5.1 The set-up of the film in the solid water phantom with the beam incident perpendicular to the plane of the film... 106 5.2 The set-up of the film in the solid water phantom with the beam incident parallel to the plane of the film... 107 xiii

5.3 Plot of normalised results for measurements of EDR2 film with Osiris software at 8-bit and 12-bit depth... 119 5.4 Plot of normalised results for measurements of EDR2 film with ImageJ software at 8-bit and 12-bit depth... 121 5.5 Plot of results for calibration for step test film with ImageJ software at 12-bit depth... 125 5.6 Plot of results for calibration of EDR2 and XV film, comparison of orientations at 15 cm depth... 134 5.7 Plot of results for calibration of XV film, perpendicular orientation, 15 cm depth... 137 5.8 Plot of results for calibration of EDR2 film, perpendicular orientation, 15 cm depth... 140 5.9 Results for measurements of EDR2 film with different scanner exposure times... 142 5.10 Results for measurements of EDR2 film with different scanner resolution settings... 144 6.1 The axial dose distribution for Case 1 measured on EDR2 film and digitised... 157 6.2 The planar dose distribution for Case 1, Beam1 measured on XV film and digitised... 158 xiv

6.3 The axial dose distribution for Case 2 measured on EDR2 film and digitised... 165 6.4 The parallel dose distribution for Case 2, Beam4 measured on XV film and digitised... 167 6.5 The planar dose distribution for Case 2 (a) Beam8 and (b) Beam4 measured on XV film and digitised... 169 6.6 The axial dose distribution for Case 3 (a) predicted by Pinnacle, showing the beam angle distribution and (b) measured on EDR2 film and digitised... 177 6.7 The planar dose distribution for Case 3, Beam7 measured on XV film and digitised... 178 6.8 The axial dose distribution for Case 4 (a) predicted by Pinnacle (b) measured on EDR2 film and digitised and (c) coloured... 189 6.9 The parallel dose distribution for Case 4, Beam6 and Beam7 measured on XV film and digitised... 190 6.10 The axial dose distribution for Case 4 Boost measured on EDR2 film (a) digitised and (b) coloured... 197 6.11 EDR2 film axial dose distribution for Case 5 (a) digitised and (b) coloured... 203 6.12 Beam7 for Case 5 planar dose distribution... 204 xv

6.13 The axial dose distribution for Case 6 measured on EDR2 film (a) digitised and (b) coloured... 211 6.14 The planar dose distribution for Case 6, Beam6 measured on XV film and digitised. Note the matchline effect that appears vertically... 212 7.1 An example of the IMRT Physics Dosimetry form developed for ICCC... 224 xvi

List of Tables 4.1 Effect of effective point of measurement on regular ionisation chamber... 80 4.2 Results for calibration of regular ionisation chamber, perpendicular orientation, 1.5 cm depth... 83 4.3 Results for calibration of regular ionisation chamber, perpendicular orientation, 15 cm depth... 84 4.4 Results for calibration of regular ionisation chamber, parallel orientation, 15 cm depth... 85 4.5 Comparison of results for calibration of regular ionisation chamber, perpendicular and parallel orientations, 15 cm depth... 87 4.6 Results for calibration of small ionisation chamber, perpendicular orientation, 1.5 cm depth... 90 4.7 Results for calibration of small ionisation chamber, perpendicular orientation, 15 cm depth... 91 4.8 Results for calibration of small ionisation chamber, parallel orientation, 15 cm depth... 92 4.9 Comparison of results for calibration of small ionisation chamber, perpendicular and parallel orientations, 15 cm depth... 94 4.10 Comparison of results for calibration of regular and small ionisation chambers, perpendicular orientation, 15 cm depth... 96 xvi

5.1 Comparison of normalised results for measurements of EDR2 film with Osiris software at 8-bit and 12-bit depth... 118 5.2 Comparison of normalised results for measurements of EDR2 film with ImageJ software at 8-bit and 12-bit depth... 120 5.3 Results for calibration of step test film with ImageJ software at 12-bit depth... 124 5.4 Results for measurements of EDR2 film, perpendicular orientation, 15 cm depth... 129 5.5 Results for measurements of EDR2 film, horizontal-parallel orientation, 15 cm depth... 130 5.6 Results for measurements of EDR2 film, vertical-parallel orientation, 15 cm depth... 131 5.7 Results for measurements of EDR2 film, 2-degree-parallel orientation, 15 cm depth... 132 5.8 Results for measurements of XV film, perpendicular orientation, 15 cm depth... 133 5.9 Results for calibration of XV film, perpendicular orientation, 15 cm depth... 136 5.10 Results for calibration of EDR2 film, perpendicular orientation, 15 cm depth... 139 xvii

6.1 Case 1 individual beams measured with regular ionisation chamber for (a) normal MU delivery and (b) tripled MU delivery... 159 6.2 Case 1 individual beams measured with EDR2 film for (a) perpendicular set-up and (b) parallel set-up... 160 6.3 Case 1 full treatment results for ionisation chambers and EDR2 film... 161 6.4 Case 2 individual beams measured with regular ionisation chamber for (a) normal MU delivery and (b) tripled MU delivery... 170 6.5 Case 2 individual beams measured with parallel XV film... 171 6.6 Case 2 full treatment results for ionisation chambers and EDR2 film... 172 6.7 Case 3 individual beams measured with regular ionisation chamber for (a) normal MU delivery and (b) tripled MU delivery... 180 6.8 Case 3 individual beams measured with small ionisation chamber for (a) normal MU delivery and (b) tripled MU delivery... 181 6.9 Case 3 individual beams measured with parallel XV film... 182 6.10 Case 3 full treatment results for ionisation chambers and EDR2 film... 183 6.11 Case 4 individual beams measured with regular ionisation chamber for normal MU delivery... 191 xviii

6.12 Case 4 overlapped beams measured with parallel XV film... 192 6.13 Case 4 full treatment results for ionisation chambers and EDR2 film... 193 6.14 Case 4 Boost individual beams measured with regular ionisation chamber for (a) normal MU delivery and (b) tripled MU delivery... 199 6.15 Case 4 Boost full treatment results for ionisation chambers and EDR2 film... 200 6.16 Case 5 individual beams measured with regular ionisation chamber for normal MU delivery... 205 6.17 Case 5 full treatment results for ionisation chambers and EDR2 film... 206 6.18 Case 6 individual beams measured with regular ionisation chamber for (a) normal MU delivery and (b) planar MU delivery... 213 6.19 Case 6 full treatment results for ionisation chambers and EDR2 film... 214 7.1 Comparison of the physics time required to check a regular radiotherapy plan and an IMRT plan... 216 7.2 All patient dosimetry results, regular ionisation chamber... 219 7.3 All patient dosimetry results, EDR2 film ImageJ 12-bit depth... 220 xix

Abbreviations %dd - percentage depth dose 3DRTP - three dimensional radiation treatment planning 3DCRTP - three dimensional conformal radiation treatment planning AAPM - American Association of Physicists in Medicine AHTAC - Australian Health Technology Advisory Committee AP - anteroposterior BEV - beam s eye view CT - computed tomography dmlc - dynamic multileaf collimator DVH - dose volume histogram EDR2 - Kodak Extended Dose Range [film] FF - field factor Gy - gray IAEA - International Atomic Energy Agency ICCC - Illawarra Cancer Care Centre ICRU - International Commission on Radiation Units and Measurements IMRT - intensity modulated radiation therapy MLC - multileaf collimator MU - monitor unit OD - optical density PA posteroanterior QA - quality assurance relod - relative optical density ROI - region of interest SAD - source-to-axis distance SSD - source-to-surface distance STF - step test film TLD - thermoluminescent dosimeter WHO - World Health Organisation XV - Kodak X-Omat V [film] xx

Z - atomic number xxi