Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Similar documents
Use of the JET Active Gas Handling Plant Exhaust Detritiation System during and after DTE1

Experiences and Challenges in Pumping the 200m3 vacuum chamber at JET

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

Gaseous detectors. 1

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Metal hydride storage system for MICE experiment at Rutherford Appleton Laboratory. Technical specification.

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

Variable Temperature Microprobe Systems

MODEL 321/421 NUCLEAR POWER PLANT TRITIUM MONITOR

Development of high sensitivity radon detectors

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

Saintech Ion Beam Systems - Ion Current Monitor

300/400 UNITS - MODULAR CONFIGURATION

Victoreen & 660-8

Micromegas in a Bulk

Remote Helium Cooling Loops for Laboratory Applications

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

Cryogenics for Neutral Beam Injector System

Radiation Monitoring Equipment

3.2 Cryoplant and Cryodistribution

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Pocket Dilution Cooler

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

REVIEW ON CONDENSER AIR LEAK TEST

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

MODEL 421 NUCLEAR POWER PLANT TRITIUM MONITOR

ELD500 PRECISION LEAK DETECTOR

Diamond Windows & MCP Detectors for Synchrotron Applications

Temperature Sensors & Compression Seal Fittings

Advances in Leak Detection in the Manufacturing Process

Cast Line Heaters The Benefits of This Space Saving Electric Heater

GAS FREE REFRIGERATOR USING PELTIER MODULE

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Characterization of Desiccant Wheels with Alternative Materials at Low. Regeneration Temperatures

Air Liquide Advanced Technologies Division Sassenage, 38360, France

Customized MCPs for Analytical Instruments. An MCP for every application

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Ultraviolet radiation detector to obtain the rate of particles at different heights

Injection with front ends open at the ESRF

Technical Manual Ionisation Chamber MUSIC80

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Variable Temperature Options for Optical Experiments

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

FEEDGAS FOR MODERN HIGH-PERFORMANCE OZONE GENERATORS. Bruce T. Stanley. Ozonia Ltd Duebendorf, Switzerland 1999

4.8 FARADAY CUP ASSEMBLY OPTION

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

CALIBRATION OF A GAMMAMED 12i 192 Ir HIGH DOSE RATE SOURCE

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Agilent InfinityLab Online SPE Solution

Designing Heated Chucks for Semiconductor Processing Equipment

Model gffoz Process Ozone Sensor (In-Line)

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Heated tools. Semiconductor equipment

Falling Film Heat Exchangers for Solar Water Heaters

SuperCDMS SNOLAB: Road to 100 mm Germanium Detectors

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

Ramon 2.2 Radon-Monitor

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth

Diamond Detectors Ltd. Fabrication and Packaging Capabilities. Kevin Oliver

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

PG 990 Atomic Absorption

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

The development of a plastic scintillator for radiotherapy dosimetry

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

ISIS Design Division Electrical Engineering. S Birch. September 2012.

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

Griffin 824 Operational Suitability: Evaluation of Clear-Down Time for Mass Spectrometry- Based Trace Detector WHITE PAPER. Philip J. Tackett, Ph.D.

Instruction Manual. B Issue B. next Pump Accessories

MicroSL Silicon Photomultiplier Detectors

Solder joints point to point. Technology day AB Tehnik 2016 Technology Day AB Tehnik

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Dosimetry issues related to the SSRT project at the ESRF

Transcription:

EFDA JET CP(04)05-07 L.B.C. Worth, R.J.H. Pearce, J. Bruce, J. Banks, S. Scales and JET EFDA Contributors Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

.

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment L.B.C. Worth, R.J.H. Pearce, J. Bruce, J. Banks, S. Scales and JET EFDA Contributors* EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK * See annex of J. Pamela et al, Overview of Recent JET Results and Future Perspectives, Fusion Energy 2002 (Proc.19 th IAEAFusion Energy Conference, Lyon (2002)). Preprint of Paper to be submitted for publication in Proceedings of the 7th Tritium Science and Technology Conference, (Baden Baden, Germany 12-17 September 2004)

This document is intended for publication in the open literature. It is made available on the understanding that it may not be further circulated and extracts or references may not be published prior to publication of the original when applicable, or without the consent of the Publications Officer, EFDA, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK. Enquiries about Copyright and reproduction should be addressed to the Publications Officer, EFDA, Culham Science Centre, Abingdon, Oxon, OX14 3DB, UK.

ABSTRACT The accuracy of process measurements of tritium with conventional ion chambers is often affected by surface tritium contamination. The measurement of tritium in the exhaust of the JET torus is particularly difficult due to surface contamination with highly tritiated hydrocarbons. JET s first unsuccessful attempt to overcome the contamination problem was to use an ion chamber, with a heating element as the chamber wall so that it could be periodically decontaminated by baking. The newly developed ion chamber works on the principle of minimising the surface area within the boundary of the anode and cathode. This paper details the design of the ion chamber, which utilises a grid of 50-micron tungsten wire to define the ion chamber wall and the collector electrode. The effective surface area which, by contamination, is able to effect the measurement of tritium within the process gas has been reduced by a factor of ~200 over a conventional ion chamber. It is concluded that the new process ion chamber enables sensitive accurate tritium measurements free from contamination issues. It will be a powerful new tool for future tritium experiments both to improve tritium tracking and to help in the understanding of tritium retention issues. Fig.1(a), and one incorporating a heater element 3 Fig.1(b). These ionisation chambers have been used mainly for the detection of tritium in the secondary containment of AGHS components, in tritium process control applications and for accountancy measurements. INTRODUCTION The Joint European Torus (JET) is the largest magnetic confinement fusion experiment and the only operational tokamak to operate with tritium. Tritium measurements are important for accounting, safety, and experimental understanding. A variety of measurement techniques are used on JET for the measurement of tritium. Ion chambers provide the simplest form of online tritium measurement. EXPERIENCE WITH ION CHAMBERS Several designs of ion chamber have been designed and tested for use in the JET Active Gas Handling System (AGHS) [1,2]. These include a conventional ion chamber, Fig.1(a), and one incorporating a heater element 3 Fig.1(b). These ionisation chambers have been used mainly for the detection of tritium in the secondary containment of AGHS components, in tritium process control applications and for accountancy measurements. These ionisation chambers have been effective in the measurement of tritium with concentrations greater than 1 MBqm -3, but due to the memory [4] effects, can be subject to offsets and large errors. The background ion current from the ionisation chamber tends to rise as the internal surfaces become contaminated with tritium oxide, tritiated hydrocarbons, or tritium which permeates into the surface structure. Heating up to 200 o C has limited success for water vapour de-contamination as tritium permeates into the electrodes and then migrates back to the surface of the ion chamber. 1

NEW DESIGN PRINCIPLES The standard ion chamber for tritium measurement works on the principle of measuring the ion current between two electrodes. The current being as result of the ionisation of the carrier gas by the beta decay of tritium. The current is driven by a bias on one electrode. The larger the volume between the two electrodes the higher the sensitivity of the instrument.the path length of the mean energy (5.7keV) decay beta in atmospheric air is ~0.36mm [5]. Hence if the volume between electrodes can be kept high, the material surfaces kept away from this volume and the surface area of the electrodes minimised, then a sensitive ion chamber, which is insensitive to contamination effects, can be produced. This principle was first used by Overhoff 4 in commercially available stack and area tritium monitors. The aim of the new JET design was to go significantly further in the reduction of surfaces within the electrode envelope for a process ion chamber. The design was also to take into account the longer path lengths of the highest energy betas (18.5keV) and longer path lengths expected from working at reduced pressure. MECHANICAL DESIGN A fine wire mesh has replaced the solid electrodes surfaces of the conventional ionisation chamber. The outer electrode mesh forms the chamber wall. For compatibility the design of the new ion chamber uses the same de-mountable Conflat flange fitted with a multi-pin feed through, as on the previous ion chambers installed at JET. The new design (Fig.1(c)) utilises a fine (50µm) array of gold-coated tungsten wires for both the bias grid and collector array. The structure supporting the wire grid array was machined from MONEL 400 and gold plated. Gold plating was used to further reduce contamination effects. The seven tungsten wires that form the collector array are tensioned and spot welded to the support structure at both ends, as are the 24 wires that make up the bias electrode. The entire arrangement has a surface area some 180 times smaller than the previous designs (~2857 mm 2 compared to ~516798 mm 2 ). The effective volume of the chamber was 401282 mm 3 giving a theoretical sensitivity of ~8.5 10 19 A/Bq. Electrical connections to the 100V outer bias grid are made through a multi-pin ceramic feed through. The collector connects a gold coated BNC connector situated at the centre of the feed through. The electrical signal was first amplified through an electrometer which was mounted directly onto the detector via the feed-through and carried to the readout through doubly screened cable. The electrometer and amplifier where supplied by The Overhoff Technology Corporation [4]. BASIC TESTS & MODE OF OPERATION An investigation into the variation of detector output current versus bias voltage was performed. The detector was stimulated using a Co 60 gamma source and the bias voltage varied between 0 and 150V. At each bias voltage the measured current from the detector is shown on Graph 1. To characterise the chamber in gas with a known concentration of tritium the wire grid ionisation chamber was installed in the JET facility helium gas-baking loop 6 in series with a tritium monitor, 2

which is used as part of the Radiation Protection Instrumentation (RPI) at JET. This monitor had previously been calibrated with known concentrations of tritium and showed the activity of tritium in the helium loop to be 48.5MBqm -3. Prior to exposure to the helium loop a background reading of 0.6E -14 A was recorded from the ionisation chamber. The ionisation chamber was exposed to the helium in the loop and an output current of 6E -13 A was recorded corresponding to a tritium activity of ~51 MBqm -3. The ionisation chamber was left continuously sampling the baking plant gas for 72 hours. A steady output current of 6E -13 A was recorded for the duration. On completion of the test, purging the detector with nitrogen caused a reduction in ion current to the original amplifier offset thus showing no memory effect at this level of tritium concentration. INSTALLATION TO MONITOR THE JET EXHAUST An ion chamber of new design was installed on the JET machine in the torus exhaust line (ML1) in parallel to an existing ion chamber (of mesh variety), and was operated using a semiautomated sequence sampling the exhaust gas. The sequence consisted of several sequential steps. Collection of the exhaust gas from ML1 followed by the introduction of a carrier gas to raise the pressure in the sample chamber to ~0.5bar. A measurement of the ion current was made and sample gas was then pumped away by ML1. Neon was chosen as the carrier gas for compatibility with the tritium re-processing plant. Using the ion chamber in this mode allows the sample gas to be exhausted from the ionisation chamber after each measurement, thus minimising the contamination caused by the build up of tritiated hydrocarbons on the ionisation chamber surfaces. During the clean up phase of the Trace Tritium Experiment [7] (TTE) the wire grid ionisation chamber in ML1 was exposed to tritium in the exhaust gas for long periods, both during pulsing and after operations where the exhaust gas was held in the ionisation chamber overnight. Prior to exposure to the exhaust gas the measured current from the chamber was 3E -14 A. The ion chamber exhaust gas sequence was operated over 60 times during the clean up phase and the final ion current measured, after single purge with neon, was 4E -14 A. The ion chamber was opened to the torus exhaust during the vessels first purge with air following TTE. The signal from the wire grid ionisation chamber was continuously monitored and is shown in Graph 2. The rapid nature of the decay has not previously been observed using other ion chambers which were effected by contamination. Graph 3 shows the tritium concentration as measured by the mesh type ionisation chamber compared to that measured by the wire grid ionisation chamber after some period of air purging. (Both installed in the same position). Note the mesh type ionisation chamber records a tritium concentration 300 times higher than the wire grid ionisation chamber due to contamination. The variation in the signal from the wire grid ionisation chamber is attributed to differing rates of air purge through the torus. 3

FURTHER INVESTIGATION It is planned to fully automate the torus exhaust sampling system, timed to the end of a JET pulse with a measurement made directly after each pulse, allowing a detailed measurement of the tritium gas balance on JET during future operations. It is also planned to extend the operation to the pumping line from the Neutral beam injection 8 (NI) to AGHS, thus enabling the inventory of tritium on the cryogenic panels in the NI to be ascertained prior to reprocessing of the gas by AGHS after regeneration. Two further ion chambers of the wire grid design are to be installed in glove-boxes on the AGHS plant and will be used to measure tritium concentrations in atmospheric air of ~ 1MBqm -3. It is also planned that an ion chamber will be installed in the tritium re-processing loop in AGHS. This ion chamber will be exposed to tritium gas with well known concentrations from 25% to 100% to further test the resistance of the chamber to contamination. CONCLUSIONS We have demonstrated a new design of ion chamber utilising ultra fine wire electrodes. The ion chamber can measure tritium down to 1 MBqm -3. We have shown that, at the concentrations of tritium in the exhaust gas from TTE, the wire grid ionisation chamber does not show any of the memory effects associated with contamination seen in other ion chambers. The ion chamber is a demonstrably significant improvement over previous JET designs and a very useful tool in monitoring the torus exhaust. Its use at JET will be expanded and its resistance to surface contamination after exposure to much higher concentrations of tritium tested. REFERENCES [1]. R. Haange et al., General Overview of the Active Gas Handling System at JET. Fusion Technology, 14 (1988) 469-475 [2]. D.B. Brennan et al., Operation of the JET Active Gas Handling System during the Trace Tritium Experiment 2003. These proceedings [3]. C.J. Caldwell-Nichols et al., The Design and Performance of the JET Ionisation Chambers for use with Tritium Fusion Technology, 17 (1992) [4]. Overhoff Technology Corporation. 1160 US Route 50, Milford, Ohio, USA [5]. Safe Handling of Tritium. Review of Data and Experience Technical reports series No.324 International Atomic Energy Agency. Vienna 1991 [6]. R.J.H. Pearce et al., The JET Gas Baking Plant for DT Operation and Analysis of Tritium Permeation and Baking Gas Activation in DTE1 Fusion Technology, 20 (1998) 1001-1004 [7]. R.J.H. Pearce et al., New Safety and Technical Challenges and Operational Experience on the JET First Trace Tritium Experiment These proceedings [8]. E. Surrey et al., Neutral Beam Injection in the JET Trace Tritium Experiment These proceedings. 4

JG04.392-4c JG04.392-5c Figure 1(a): Mesh type ionisation chamber; Volume 699713 mm 3. Surface Area 516798 mm 2. Figure 1(b): Ionisation chamber (heater type). Volume 570000 mm 3. Surface Area ~450000 mm 2. JG04.392-6c Figure 1(c): New wire grid type ionisation chamber; Volume 401282 mm 3. Surface Area 2857 mm 2. 5

0.25 0.20 Measured Current (pa) 0.15 0.10 0.05 0 0 20 40 60 80 100 120 140 160 Bias Voltage (V) JG04.392-1c Graph 1. Ion chamber output current as a function of bias Activity MBqm -3 300 200 100 0 0 100 200 300 400 500 Time (h) JG04.392-2c Activity GBqm -3 Activity MBqm -3 12 10 40 20 0 Mesh Type Ionisation Chamber ML1 Wire Grid Type Ionisation Chamber ML1 175 200 225 250 275 300 375 Time (h) JG04.392-3c Graph 2. Activity of torus exhaust Vs time during vent and subsequent air purge. Graph 3. Comparison of signals from ionisation chambers in ML1 6