COMPARATIVE ANALYSIS AND PEDESTRIAN SIMULATION EVALUATION ON EMERGENCY EVACUATION TEST METHODS FOR URBAN RAIL TRANSIT STATIONS

Similar documents
说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

Prospects and challenges for sustainable urbanization in China

A New Generation of Active Intrusion Detection System for Physical Protection

Collaborative efforts for sustainable campus 可持续校园建设多方协作机制的初探

Work Report of Chinese Steering Commi.ee of Landscape Architecture Educa8on

BUREAU VERITAS GREATER CHINA 必维国际检验集团 大中华区 CRANE SERVICES 起重机服务

Personal Care Appliances in Sweden

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

Personal Care Appliances in Thailand

KMART Corrective Action Plan

LEVEL SENSORS & FLOAT SWITCHES

Provisions for the Means of Escape and Means of Access by Using Lifts and Escalators in the MTRC Main (U/G) Station

PREVENT ALL INJURIES IN THE KITCHEN. GO HOME SAFE AND HEALTHY.

Hot Issues in Fire Engineering July 2014

Kitchen Exhaust Duct (KED) Requirements

TRANSPORTATION EXISTING 交通现状

践行里约 +20 决议, 示范新型城镇化 : 国际人居环境范例新城倡议

New Town Development and Practices

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

Retrospect And Prospect Of Master Land Use Plan In China

CFD Analysis of Fire Characteristics on Subway Junction Station

SUNSTAR 单片机专用电路 TEL: FAX: Features 6 Digit 6 Function LCD Alarm Watch with RGB LE

The Study of Evacuation Times from the Multiplex Theatres

亚太地区世界遗产培训与研究中心 ( 上海 ) 简讯 World Heritage Institute of Training and Research - Asia and Pacific, Shanghai

XJTLU 2017 INTERNATIONAL SYMPOSIUM 国际学术研讨会 TRANSPORT AND URBAN TRANSFORMATION IN CONTEMPORARY CHINA 当代中国的交通与城乡转型发展. Date and Location 会议时间与地点

Urban Models for the 21st Century

Jiangbei New District, Nanjing ISOCARP Urban Planning Advisory Team Report

Gas Pipeline Locating Leak detection and Safety Assessment

矿用电缆 矿 用 电 缆 江苏亨通电力电缆有限公司

漫漫求索科研路 西南交通大学竢实扬华奖章答辩. Evacuation Case Studies and Evacuation Data. Junmin Chen Southwest Jiaotong University 地图学与地理信息工程 2010 级博士研究生

Senab Interior established on the Bund introducing Scandinavian design and new ways to organize the office

RAS-DX18HDK/RAC-DX18HDK

Rosemount 848T High Density Temperature Measurement Family

Consumer Appliances in Germany

Plant Safety 沼气厂安全. Raphael Thies and Dr Katharina Backes

SUSTAINABLE URBAN PLANNING PRINCIPLES WORKING TOWARDS SUSTAINABLE FOREST PRODUCT SOURCING:

Shaking Peltier Device

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

PE Series Jaw Crusher P E

Retailing in Romania. Customer Service Hotline: Page 1 of 23

RECENTLY, multicarrier modulation techniques, such

Award-winning and absolutely new, Very stacks, swivels, and flexes far beyond ordinary seating to inject comfort and life into any space.

qianlong garden restoration project 乾隆花园修复工程

Simulation study of evacuation in high-rise buildings

The Home Depot Quality System Audit. * Example Report * North America Latin America

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

Dr. Qiaoling Luo. Publications

A Study on the People Evacuation Safety for the. Underground MRT Station

New Rural Planning Guidelines in the Chengdu Plain: The Case of Tianfu New Area

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

PolyBox TM. Edition II. Operation Manual

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

PMAC202 Branch Circuit Power Meter User Manual V1.0

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Technical Code for Engineering of Security and Protection System

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

地址 : 北京市朝阳区建国门外外交公寓 7 号楼 1 单元 101 号 电话 : / 传真 :

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

RTKL 谨在此向中国客户呈献本系列宣传册 本丛书一套四册, 涵盖内容广泛, 不仅向您展示 RTKL 过去辉煌的历史, 更力图展现我们对未来的卓越见解 我们的每件作品都富于灵动性和高品质, 在此呈献的仅仅是我们宏大作品库中的极小部分

Installation Instructions for the MICRO SWITCH VPX Series Valve Position Indicator for Hazardous Locations

Characteristics of nitrogen, phosphorus and potassium absorption and optimum fertilization in Sugarcane Liuqiang ZHOU, Hongwei TAN

TeMA. Vol.10 n.2 August 2017 METHODS, TOOLS AND BEST PRACTICES TO INCREASE THE CAPACITY OF URBAN SYSTEMS TO ADAPT TO NATURALAND MAN-MADE CHANGES

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Enlightenment of Biodiversity Construction in Chanba Ecological District of Xi 'an

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

Beijing Urban Design Studio Summer 2008

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

A Study of the Improvement of Planning Systems for Land Use Control in Agricultural Heritage Sites

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

TeMA is realized by CAB - Center for Libraries at Federico II University of Naples using Open Journal System

Evacuation Hazards in Crowded Subway Stations

Dehumidification of air with a newly suggested liquid desiccant

Urban Greenery Worldwide Researches on Urban Greenery and Urban Climate

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

Rainwater Harvesting Techniques in Syrian Desert (Badia Basin)

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

System development and performance evaluation of track intrusion in Taipei MRT system

RURAL URBAN FRAMEWORK Sample

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Boiler Safety Technical Supervision Administration Regulation

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

MultiTemp IV Thermostatic Circulator

QIN Jing. Binzhou University, Binzhou, China. Identification and Classification of Hedges

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

丹麦,Fuglsang 美术馆 / Tony Fretton Architects

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

不同灌溉方法对冬小麦农田小环境及根系分布的影响

Tunnel Fire Dynamics and Evacuation Simulations

Transcription:

ZIJIA WANG FENG CHEN E-mail: fengchen@bjtu.edu.cn XIAOHONG LI Beijing Jiaotong University Department of Civil and Architecture Engineering Beijing 100044, PR China Transport Engineering Review Accepted: Nov. 29, 2011 Approved: Nov. 13, 2012 COMPARATIVE ANALYSIS AND PEDESTRIAN SIMULATION EVALUATION ON EMERGENCY EVACUATION TEST METHODS FOR URBAN RAIL TRANSIT STATIONS ABSTRACT The emergency evacuation test method of rail transit station not only affects the operation safety of the station, but it also has significant influence on the scale and cost of the station. A reasonable test method should guarantee both the safety of evacuation and that the investment is neither excessive nor too conservative. The paper compares and analyzes the differences of the existing emergency evacuation test methods of rail stations in China and other regions on the evacuation load, evacuation time calculation and the capacity of egress components, etc. Based on the field survey analysis, the desired velocity distribution of pedestrians in various station facilities and the capacity of egress components have been obtained, and then the parameters of pedestrian simulation tool were calibrated. By selecting a station for the case study, an evacuation simulation model has been established, where five evacuation scenarios have been set according to different specifications and the simulation results have been carefully analyzed. Through analyzing the simulation results, some modification proposals of the current emergency evacuation test method in the design manual have been considered, including taking into account the section passenger volume, walking time on escalators and stairs of the platform, and the condition in which the escalator most critical to evacuation should be considered as out of service. KEY WORDS urban rail transit, station, emergency evacuation, comparison, pedestrian simulation 1. INTRODUCTION As passenger distribution nodes, stations of urban rail transit are one of the public buildings with the highest pedestrian density. Furthermore, stations, especially the underground ones, have closed environments and varied facilities, where passenger s walking behavior is complicated, so in case of fire, toxic gases or other human-caused accidents, the passenger evacuation will face great challenges. If the evacuation is not timely, the consequences will be disastrous [1]. Therefore, the relevant design specifications or manuals of stations in China and other countries specify that the scale and layout of the distribution facilities at stations should not only be calculated using passenger load under normal conditions, but they should also be checked to determine if they can meet the demand of emergency evacuation. However, the regulations of design method for emergency evacuation, including the calculation methods of evacuation load, facility evacuation capacity per unit width and evacuation time, etc., are quite different among the design specifications of different countries and regions [2]. For the same station with the same passenger volume, the results obtained by different test methods are quite different. Therefore, it is necessary to conduct a comparative analysis and evaluation on these test methods so as to provide proposals for establishing a secure and economical check calculation method. 2. COMPARISON OF EMERGENCY EVACUATION TEST METHODS IN DIFFERENT REGIONS Design specifications and manuals are the main embodiment at practice level of the relevant research. This paper chooses three typical specifications and manuals about test methods of emergency evacuations of urban rail transit station, and takes a comparative analysis on the load of evacuees, facility evacuation capacity and evacuation time calculation methods of these design specifications and manuals. The three Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542 535

specifications respectively are the Code for the Design of Metro [3] of Mainland China (2003 edition, hereinafter referred to as Code ), the Underground Station Design Guideline of MRT [4] of Taiwan (hereinafter referred to as Guideline ), and the NFPA 130: Standard for Fixed Guideway Transit and Passenger Rail Systems [5] of the USA (2007 edition, hereinafter referred to as the Standard ). 2.1 Code of Mainland China The evacuation test method in the Code is relatively simple. In accordance with the relevant provisions, all the passengers and staff on the platform should be evacuated from the platform within 6 minutes (including 1-minute reaction time). The time test formula is: Q1 Q T 1 + 2 = + (1) 09. 6 A 1 ^N- 1 h+ AB 2 @ In the formula, Q1 denotes crush load of a train; Q2 is entraining load and staff on the platform; A1 for capacity of unit width escalator (person /(min m)); A2 refers to capacity of unit width stairway (person / (min m)); N is quantity of escalators; B means total width of all the stairways. The occupant load consists of the entraining load in a headway and the workers on the platform when emergency happens and a fully loaded train arrives in the station. Considering that the total width of stairways influences the scale of the platform and the distribution capacity of the escalators, it is assumed that one escalator is out of service but the working escalators are still used as egress route. The facility evacuation capacity is not specified. According to the design material of the designing institute, the evacuation capacity still adopts the capacity under normal operation condition, where escalator evacuation capacity is 150 persons/(min m) and the stairways evacuation capacity is 62 persons/(min m). Counting in panic influence, the evacuation capacities are deducted by 10 percent. 2.2 Standard of USA The Standard sets two requirements on emergency evacuation: first, empty the platform in four minutes; second, the most remote passengers to the exits can move to the safe place within six minutes. The following formula is used to calculate the platform evacuation time: Q Fp = p # 4 min (2) C p where Qp is occupant load on the platform; Cp refers to platform facility evacuation capacity Provisions 5.5.5.6 and 5.5.6.2 of the Standard describe the evacuees on the platform and the facility evacuation capacity in detail. There is no formula to calculate the occupants load but it stipulates that the passengers awaiting on the platform and the passengers in the train need to be considered. The volume of passengers in the train is determined according to the combination of the headway in peak hours and such factors as the unpunctuality rate and the system reaction time, etc. For the facility evacuation capacity, the escalator is considered as stairways, and it is assumed that the escalator most critical for evacuation is out of service, and the escalators take the evacuation of no more than half of the passengers except in specified conditions. For the evacuation time from the most remote point of the platform to a safe place, the Standard does not give a definite formula, but rather just stipulates that the concourse level in a different fireproof partition can be taken as a safe place, considering the walking time on the facilities and the waiting time at the bottleneck facilities. According to the example given by the Standard, if taking the entrance/exit as the safe place, the total evacuating time can be calculated as follows: m n / / (3) i = 1 j Ttotal = Ti+ Wj where: Ti - denotes Walking time on the circulation facility i, including platform, stairways, concourse level, and fare collection equipment; Wj - is the waiting time at the bottleneck facility j. Take the calculation of Wp for example, which is the waiting time at the exit of the stairways and escalators: Wp= Fp- Tp, and Fp means platform evacuation time, calculation formula shown as formula (2); Tp is walking time from the most remote point to its nearest stairway exit. Designing parameter value is shown in Table 1 [7]. Table 1 - Facility evacuation capacity Facilities Maximum capacity (person/(min m)) Walkway 81.9 Maximum velocity (m/min) 37.8 (Low density zone) 61.0 Stairway 55.5 14.63 (vertical) 2.3 Guideline of Taiwan MRT The provisions about emergency evacuation of Guideline of Taiwan MRT are similar to the Standard, but for the occupant load and facility evacuation capacity, it is more detailed, shown as follows: W 2IL. Lor1900 6F1 IF 1 = + + 2 # 4min (4) 70^a- 1h+ 35b where F1 - refers to peak minute passenger volume of peak direction; F2 - peak minute passenger volume of off-peak direction; a - number of escalators (a - 1 536 Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542

denotes one that is considered as having failed); b - number of equivalent 0.55m width stairways; I - is headway, min; L.L - section load, or line load; 1900 - passenger load of a fully loaded train (6-car train). The platform evacuation load adopts the sum of the larger value between the crush load of a train and section load in two headways and the entraining passengers in 6 minutes of peak direction and that of offpeak direction in a headway. For the calculation of the evacuation time of the most remote point, it is the same as the one in the Standard. 2.4 Analysis of the main differences In conclusion, the main differences of the provisions given by the three standards are presented respectively as follows: (1) For the basic requirements of evacuation, the Code merely requires that pedestrians on the platform be evacuated in 5 minutes, while the Standard and the Guideline require that this should be completed in 4 minutes, and the total evacuation time from the most remote point to the safe point, which is not necessarily the concourse level, should be limited within 6 minutes. Actually, it is possible to have the pedestrians on the platform evacuated in 4 minutes, but the last pedestrian s total walking time may not be able to meet the requirement. For this problem, the Code regulates that the distance between any point on the platform and the exit of the stairs and escalators should be no more than 50 meters, which enables the time of walking on the platform less than the time waiting at the exit. Furthermore, according to the practical design of stations in China, although the concourse level and the platform belong to the same fire compartment, owing to the paid area which is divided by removable barrier the fare collection equipment is no longer the bottleneck in case of emergency, and as a result, the concourse level can be considered as a safe point. However, the walking time between the exits of the stairs/escalators and the concourse level may have effect on the last passenger, and this still needs further analysis whether such walking time should be calculated in the whole evacuation time. (2) With regard to the calculation of the evacuation load on the platform, the Code considers just the crush load of a train, staff of the station and the passengers awaiting on the platform, where the exact volume of waiting passengers is not specified, while the designing staff adopts the number of waiting passengers of a headway. The Standard gives no definite calculation method of the passengers waiting on the platform, but the cases of delay and system response need to be taken into consideration. The Guideline presents the definite and conservative rules. The passengers waiting on the platform are divided into two groups: peak direction and off-peak direction. As to the peak direction, passengers waiting on the platform should be counted as passengers gathered in 6 minutes rather than one headway. The lager one between the section load in two headways and the crush load of a train is taken as evacuation load in train. Considering the reaction ability of the FAS system, it is practicable to take the entraining load in one headway. Since the current long-term headway of new lines in central areas is 2 minutes or even shorter, it may happen that two trains in opposite directions arrive at the same time during emergency events, and if the section load is larger than the crush load of a train, the calculation occupant load in the Code cannot meet the requirement. (3) With respect to the evacuation capacity, the Code adopts the normal operation capacity of the stairs and escalators, while the Standard and the Guideline take escalators as stairways in case of emergency, and the value is less than that of the Code (upward-moving stairs capacity is 10.5 percent less than that of the Code ). The provisions of the Code explain that because the evacuation capacity of the stairs is far less than that of the escalators, if the escalators are regarded as stairways in case of emergency, the scale and also the construction cost of the station will be much increased. As a solution, the electricity load of the escalators is raised to the first grade to guarantee normal operation in case of emergency. The Standard clearly specifies that the escalator out of service is assumed to be the most adverse to evacuation, but the Code gives no such specifications. The practical evacuation capacity cannot be experimented, so the maximum value in operation is adopted. 3. EVALUATION OF EVACUATION METHODS THROUGH SIMULATION The analysis above indicates that compared with the standards of emergency evacuation in other countries and regions, the Code requires further study in parameter selection and evacuation time calculation method. The field experiments are unavailable for evaluating the evacuation method, while computer simulation provides a feasible way and it has been adopted in this paper to test and evaluate the evacuation method. 3.1 Case station and simulation model A certain station in planning has been chosen as the case station: 6-car train, centre platform with single column, the peak hour factor is 1.3 and the future headway is 2 minutes. The basic data of pedestrians Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542 537

are as follows: the platform width is 13 meters, 3 meters for waiting areas on each side, two groups of stairs are settled splayed symmetrically, each side contains a group of escalators including an upward-moving and a downward-moving one, and the stairs in the middle of two escalators with a width of 2.5 meters. The facilities on the platform are settled as Feature 1. The section load denotes the passenger volume on the train just before arriving at the station. Table 2 - Station forecast long-term passenger volume Track Long-term peak hour passenger volume (person/h) Boarding passengers Alighting passengers Section load Right 9,784 4,053 28,348 Left 8,753 6,839 26,816 Since the temporary barrier between the paid zone and the un-paid zone on the concourse level can be removed quickly, and a well designed ventilation system is designated, so it is reasonable to take the concourse level as a safe place and thus as the evacuation destination in the simulation analysis. In accordance with the passenger flow and facilities scale, using the calculation method and parameters in the Code, the evacuation time of the platform is 3.19min. (excluding 1 minute reaction time) and it meets the requirement. If using the practical capacity, the emptying time is 4.09min. and still the requirement is met. The time of 4.09 minutes is adopted as the value in the Code. However, the calculation in the Code is based on a simple static volume-capacity method, while emergency evacuation is a complex dynamic process. Whether the above result is reliable, it is not certain. And also, according to Chapter 2, the method in the Code differs a lot from the one in design manuals of other countries or regions. To this end, it is necessary to apply micro-pedestrian simulation to evaluate the method and determine the reasonable one. Thus, a 3D simulation environment of the case station has been built according to Figure 1 with simula- Figure 1 - Platform arrangement Figure 2 - Simulation model 538 Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542

tion tools developed based on the social force model [8-10], as shown in Figure 2, including the train. 3.2 Parameter calibration According to abundant statistical data collected from the field study in typical urban railway stations in Beijing, the desired speed distribution of pedestrians on the stairs and the platform and the practical capacity of the stairs and escalators have been finally determined. The simulation model parameters were calibrated. According to the features of pedestrian distribution on the steps, the practical capacity of the stairs and escalators cannot reach the design capacity. After calibrating the parameters including speed distribution etc. of the simulation model, the values of the maximum capacity obtained from the simulation are in accordance with the test results, which confirmed the rationality of the calibrated parameters. Table 3 - Desired speed attained in stations from field study Facility Male Global Female Stairway up (Horizontal Direction) Stairway down (Horizontal Direction) Max (m/s) 1.956 1.733 1.194 1.236 Min (m/s) 0.828 0.697 0.306 0.547 Mean (m/s) 1.391 1.180 0.700 0.728 Sq. Dev. 0.038 0.031 0.024 0.026 Table 4 - Facility capacity attained in practice from field study Facility Design manual (person/(min m) Practical (person/(min m) Escalator 0.65m/s 160 115 Stairways 3.3 Scenario setting Up 62 57 Down 70 66 There are five evacuation scenarios considered in the simulation based on the analysis in Chapter 2. Scenario 1: The evacuation load in the Code includes entraining passengers awaiting trains for both directions in one headway (2 minutes here), which are 9,784/60 2 1.3=424 (rounded up) and 8,753/60 2 1.3=380 (rounded up) calculated from the long-term peak hour boarding passenger volume in Table 2 with peak hour factor of 1.3, respectively, and crush load of one 6-B-type-car-train, which is 1,460 in design manual, and crew on the platform (15 persons). Then, the evacuation load in this scenario is totalized as 424+380+1,460+15=2,279. In addition, the most critical escalator for evacuation is considered out of service. Scenario 2: Assuming that two trains arrive with train load of one headway on all tracks, the larger of the total train load and crush load of one train is adopted. In this case, the train load is 28,348/60 2 1.3 (rounded up) plus 26,816/60 2 1.3 (rounded up) derived from the long-term peak hour section load in Table 2 with peak hour factor, which is bigger than the crush load of one 6-B-type-car-train, so it is taken as evacuation load in train. Entraining load and crew load is the same as in Scenario 1. Therefore, the evacuation load in this scenario is totalized as 424+380+1,229+1,163+15=3,211. The most critical escalator is considered out of service. Other conditions remain the same as in the Code. Scenario 3: Similar to Scenario 1, whereas escalators are taken as stairways, with the most critical escalator out of service. Scenario 4: Similar to Scenario 2, whereas escalators are taken as stairways, with the most critical escalator out of service. Scenario 5: Similar to Scenario 1, with the least critical escalator out of service. 3.4 Analysis of simulation results With the simulation model above, the five evacuation scenarios were carried out. The evacuation begins when the train arrives with the awaiting crowd randomly generated on the platform. According to the investigation, the model assumes that 80 percent of the crowd stands at both sides of the waiting areas and the rest of 20 percent in the middle circulation area facing the stairways. According to the research by Cheung [11], the probability of choosing escalator for passengers at the entrance of one abreast escalator-stairway and the time difference between using escalator and stairway fits Logistic regression. During simulation, the average time difference between 10 passengers traversing escalator and stairway is calculated dynamically, so the probability for the following passengers choosing escalator can be drawn through the Logistic model with calibrated parameters. According to the passenger flow ratio through the entrance and exit, the largest passenger flow volume emerges at the upward direction on the left platform with the adjacent and the farthest stairway and escalator being the most adverse and the most favorable conditions, respectively. The evacuation is completed when the pedestrians reach the concourse level area. When the simulation ends, the walking time and the distance for each passenger were recorded. Then the total evacuation time and the average walking distance and time were calculated and listed in Table 5. Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542 539

Figure 3 - Emergency evacuation begins when the train arrives at the station Table 5 - Simulation results of evacuation simulation evacuation time is 212s larger than the one calculated with the method in the Code, which is far from meeting the evacuation requirements. 3) Escalators are taken as stairways in Scenarios 3 and 4, with other conditions as Scenarios 1 and 2, respectively. The simulation results indicate that the evacuation times in the two scenarios increase by 117s and 135s, respectively where escalators are taken as stairways. To meet the requirement when the escalator is seen as stairways, the additional stairway must be provided and the station width and the construction cost will increase sharply. In fact, after upgrading the reliability from the secondary to the first grade, the failure rate of the escalators can be guaranteed. Therefore, it is not appropriate to be too conservative and to increase the investment dramatically. 4) Scenario 5 shows that the failure of the least or the most critical escalator has notable influence on the evacuation. In this case, the evacuation for the scenario with the least critical escalator hav- Scenario Total evacuation time(s) Average evacuation time(s) Average evacuation distance(m) Compared with the calculation in the "Code" (s) Whether with satisfaction 1 331 146 48.04 +86 Yes 1 2 457 167 45.87 +212 No 3 448 209 47.55 +203 No 4 592 247 46.30 +347 No 5 299 119 46.34 54 Yes Note 1: The requirement cannot be satisfied if the reaction time (1min.) is taken into account in practice. The simulation results demonstrate the following: 1) Scenario 1 shows that, without counting the reaction time, the evacuation time in the simulation is 86s larger than the calculated time The main reason is that the alighting time of a person in the train loaded with passengers and the time spent on the stairway and escalator by the last pedestrian are not reflected in the calculation method. According to the simulation analysis of the travel time, the passenger alighting time is 11s; the average time of passengers to get through the stairway is 48s; the total is 59s. Therefore, they should be included in the calculation of the platform evacuation time. 2) Scenario 2 illustrates that, for stations with high section load as the case station, if the trains in opposite directions reach the station at the same time when the accident happens (which is highly possible), the occupant load will far outweigh the load calculated with the method in the Code (more than 40.90 percent), the corresponding 540 Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542

ing failure takes 32s less than that for the scenario with the most critical escalator having failure. So it should be clearly specified that the evacuation time should be calculated in accordance with the condition where the most critical escalator is out of service. 4. CONCLUSION Through comparative analysis of the typical evacuation test methods for rail transit stations in China and other countries, combined with field data and pedestrian simulation, the following main conclusions have been reached: 1) Through the comparison and analysis between the Code and the test methods of emergency evacuation in other countries and regions, the differences below can be confirmed: other standards consider not only the platform evacuation time, but also the walking time from the farthest point to the safe position; other standards consider evacuees load calculation in a more conservative and comprehensive way; although escalators are regarded as evacuation facilities in other standards, they are seen as the stairways, where the escalator most critical to evacuation should be assumed as having failed; the stairways and the escalators carrying capacities set in the Code are higher than those in other standards, but the actual values cannot reach the specified values. 2) The simulation illustrates that it takes more time to egress than the time that was calculated. The main reason is that the time of passenger s alighting and passing through from the escalator to the platform is not reflected in the calculated value. 3) For the stations with high section load, when two trains on both tracks reach the station simultaneously, the evacuation time is much longer than the scenarios where there is only one fully loaded train. 4) When the evacuation is calculated, the position of the failed escalator has a great influence on the evacuation time. Based on the conclusions above, the test method in China can be improved in the following aspects: 1) Because many of the paid and free areas of the concourse level are temporary barrier the concourse level has high egress capacity. In addition to the well-designed FAS and ventilation system, the concourse level can be regarded as safe area as specified in Code [12], but the walking time on the stairways and the escalators should be included into the platform evacuation time. 2) The evacuation load shall adopt the larger one between the crush load of a train and the section load, and should also include the entraining load and the staff. 3) The escalator with most adverse effect on evacuation should be assumed as having failed. 4) As the facility evacuation capability adopts the measured value, while other values remain the same, the calculation formula is as follows: max6qv, ^IQlh@ + IQb+ Qs T = 1 + + Ts (5) 09. 6A1^N- 1h + AB 2 @ where, Qv denotes full passenger volume in a train; Ql, section passenger volume; Qb, the number of waiting passengers; Qs, the working staff; I, headway; Ts, walking time from the platform to the concourse level, and the meanings of other parameters are the same as in Formula 1. ACKNOWLEDGMENT Supported by National Natural Science Foundation of China (Program ID: 51278029) and Beijing Scientific Research Base Construction Program (Program ID: C10H00010) 王子甲, 陈峰, 李小红 ( 土木建筑工程学院, 北京交通大学, 中国, 北京,100044) Ō 城市轨道交通车站紧急疏散检算方法对比分析与仿真评价 摘要 轨道交通车站紧急疏散检算方法不仅关系到车站的运营安全, 同时对车站规模和造价有重要影响 合理的检算方法应该能在保证乘客疏散安全的同时不至投入过大, 过于保守 本文比较分析了目前国内外设计规范中检算方法在人员疏散负荷 疏散时间计算和通过能力取值等方面的异同 采用调研分析的方法确定了行人速度分布和设施通过能力, 标定了计算机仿真工具的参数, 并选择案例车站建立了行人疏散仿真模型, 根据不同规范的差异设定了 5 个仿真疏散工况, 并对仿真结果进行了深入分析, 基于此提出了考虑断面客流量 计入楼扶梯行走时间和明确故障扶梯应为最不利位置的扶梯等紧急疏散方法改进建议 关键词 城市轨道交通车站紧急疏散比较行人仿真 LITERATURE [1] WANG Yan-fu JIANG Jun-cheng: Research of Safety Evacuation from Subway Fire [J]. China Safety Science Journal, 2007, 17(7):26 [2] WU Jiao-rong; FENG Jian-dong: CHEN Xiaohong. Comparative Study of Subway Station Evacuation Design of PR China and USA [J]. Journal of Tongji University, 2009, 37(8): 1035-1041. [3] GB50157-2003. Metro Design Code of China [S] [4] Cheng, Yi-Hsuan: A Study on Layout of Major Facilities in Transit Station [D]. Taiwan, National Chiao Tung University, 1999 Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542 541

[5] NFPA130. Standard for Fixed Guideway Transit and Passenger Rail Systems [S], 2007 Edition. NFPA, 1 Batterymarch Park, Quincy, MA 02169-7471 [6] Beijing Urban Engineering Design & Research Institute Co., LTD, Design Specification of Beijing Metro Line 15 [R], 2010 [7] Transportation Research Board. Transit Capacity and Quality of Service Manual [M]. 2003 [8] Parisi, D.R., Dorso, C.O.: Microscopic dynamics of pedestrian evacuation [J]. Physica A. 354 (2005): 606-618 [9] D. Parisi, R., Gilmana, M., Moldovana, H.: A modification of the Social Force Model can reproduce experimental data of pedestrian flows in normal conditions, Physic A. 388 (2009) 3600-3608 [10] Johansson, A., Helbing, D., Shukla1, P.K.: Specification of a Microscopic Pedestrian Model by Evolutionary Adjustment to Video Tracking Data, Advances in Complex Systems. 25 (2008) [11] Cheung, C.Y., William H.K. Lam. Pedestrian route choices between escalator and stairway in MTR Stations [J]. Journal of transportation engineering, 1998(5): 277-285. [12] Shi, C. et al.: Modeling and safety strategy of passenger evacuation in a metro station in China. Safety Sci. (2010), doi:10.1016/j.ssci.2010.07.017 542 Promet Traffic&Transportation, Vol. 24, 2012, No. 6, 535-542