Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Similar documents
PowerVac G Single to Twin Conversion Kit [ ]

VetPro Solo Installation

Installation & Operation

PRE-INSTALLATION GUIDE

Vacuum Plumbing Layout Recommendations

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Artizan Ortho-Pedo Bench Installation / User Manual

IMAGE V. Parts and Service Manual

PRE-INSTALLATION GUIDE

TSS 15/55 Hi-Lift Vacuum

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

USER MANUAL/Installation Instructions LRV-4

PRE-INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

PRE-INSTALLATION GUIDE

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

SAVE THESE INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

DRAIN WATER TEMPERING INSTALL

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

LC Series - Light Commercial Pump Station Installation and Operation Manual

PRE-INSTALLATION GUIDE for MODELS

A B A B4

Installation Instructions 30 French Door Built-in Wall Ovens

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

INSTALLATION INSTRUCTIONS

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

Installation Manual PS-225 & PS-275

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

690 Power Fishing System

Product Support Bulletin

Viking Installation Guide

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

690 and Power Fishing Systems

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

KD-27A SERIES DISHWASHERS

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

Top Control Dishwasher

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

PRE-INSTALLATION GUIDE for MODELS

Helpful Tip: NOTE:

A HEATER KIT With Diesel Engine Connection Fittings

Water Boilers ME10EN, ME15EN. Table of Contents

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

FLOOD KING 120V. 2. Keep all filters clean. Do not operate the machine if the filters are clogged.

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

B-14G. for series number with jm or j

Installation Instructions

HOT WATER BOILER ( MBH)

INSTANT HOT WATER DISPENSER

Installation Manual PS-200 & PS-201

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

CLe-series Dishwashers

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

INSTALLATION INSTRUCTIONS

Cool IR. Model C104 - Cooling System. Instruction Manual

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

347002K/177002K/34900

COBRA -300H EXTRACTOR

Installation Instructions

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

MODEL 6430T, 6460 & 6460T POTATO PEELER

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

DRAIN WATER TEMPERING INSTALL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324


INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

INSTALLATION INSTRUCTIONS

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

MOUNTING INSTRUCTIONS

MODEL MW200 MODEL MW600 AIR DRYER

Installation Instructions

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Transcription:

Dry Assembled Elbows MUST Glue when Installed Exhaust Connection P-Trap Must Be Installed to Exhaust or Warranty will be Voided AA2360 Refer to this Manual for installation Instructions 2011 Midmark Corp. 60 Vista Drive Versailles, OH 45380 USA 1-800-643-6275 1-937-526-3662 003-2025-00 Rev. R

PowerVac G Installation Applies to Models: Single Vac Units G3, G5, G7 Twin Vac Units G6, G10, G14 warning Motors are thermally protected with automatic reset. Unit may start without warning. Float Connection Inlet Hose to Vac Unit Connection Vacuum Gauge Caution Vac base unit weighs 375 lbs (170 kgs). Use care when moving to prevent personal injury. Raise leveling feet to roll base unit or use lift handles (77001455). Inlet Hose From Operatory Connection Gasket Vacuum system must be installed per local plumbing and electrical codes. Do not operate without cover. Place vacuum system in a dry, well ventilated area on a solid, level surface. Verify all sides of base unit are not obstructed. Recommended - 6 inches on left and back side. Required - 12 inches on front and right side. Separator Front Cover Fasteners Connections for Remote Low voltage Wires, Float Cords Fan Plugs, Twin Paralleling, and Pressure Sensor Pre-Install, remove shipping bolts... A) Unfasten front cover by turning each fastener 1/4 turn, counter clockwise. B) Lift front cover straight up to remove from side panels. C) Remove lock nuts, washers and bolts, replace front cover. Shipping hardware can be thrown away, they will not be reused. Drain Connection Base Unit 6" Base Unit 6" Hour Meter 12" 12" Shipping Bolts and Washers Lock Nuts Keypad On / Off Switch Level Feet Gear Lube Site Glass 2

Important Information Intended Use To provide vacuum suction during general examinations and procedures conducted by qualified dental professionals. Electromagnetic Interference This Midmark PowerVac G is designed and built to minimize electromagnetic interference with other devices. However, if interference is noticed between another device and these units: Remove interfering device from room Increase separation between vacuum and interfering device Contact Midmark if interference persists Disposal of Equipment At the end of product life, the units, accessories, and other consumable goods may become contaminated from normal use. Consult local codes and ordinances for proper disposal of equipment, accessories and other consumable goods. Transportation / Storage Conditions Ambient Temperature Range:... 50 F to 104 F (+10 C to +40 C) Relative Humidity...10% to 90% (non-condensing) Atmospheric Pressure... 700hPa (20 Hg) to 1060hPa (31 Hg) Safety Symbols danger Indicates an imminently hazardous situation which will result in serious or fatal injury. This symbol is used only in the most extreme conditions. warning Indicates a potentially hazardous situation which could result in serious injury. Safety Symbols continued... Consult User Guide for important information. Proper shipping orientation Fragile Protective earth ground Keep Dry Maximum stacking height (palliated units) Fuse rating specification Caution Indicates a potentially hazardous situation which may result in minor or moderate injury. It may also be used to alert against unsafe practices. IPXO Caution hot surface Ordinary Equipment Indicates a potentially hazardous situation which could result in equipment damage. 3

PowerVac G Loose Parts Exhaust Fittings Intake Fittings Bushing - 2 NPT x 1 1/2 FPT, PVC* Adapter, 1 1/2 NPT x Socket, PVC* Coupling Reducer SOC 2 x 1 * Exhaust Assembly Components** Pipe Nipple, 1 1/2 NPT, Plastic* Coupler, 1 1/2 SOC 2 x 1 * Adapter, 1 1/2 NPT x Socket, PVC* Extra Fittings for Hose Connections to Existing Pipes * Included with Separator Loose Parts Kit - 002-1441-00 ** Included with Base Loose Parts Kit - 002-1440-00 PowerVac G Parts A sample bottle of Precision Clense Plus is packaged with the separator assembly, refer to care guide for instructions. Garden Hose Adapter* Refer to Care Guide on Base Unit or www.midmark.com Foot Wrench 1/2 Twin Opened End** 1 x 8 low pressure Exhaust Hose Assembly** Intake Hose Assembly* Drain Hose Assembly* AA2244 4

PowerVac G Site Requirements Plumbing Electrical : All PowerVac G models electrically designed to be sold in U.S.A. or Canada. Environmental Exhaust Line Single Models G3, G5, G7 Twin Models G6, G10, G14 Type Size PVC Sch 40, CPVC Sch 80, Copper or Galvanized Steel 1-1/2 for up to 15 exhaust line length 2 for greater than 15 exhaust line length Termination 1 1/2"" PVC Sch 40 CPVC Sch 80, copper or Galvanized Steel 2 for all exhaust line lengths Intake (Suction) Line Single Models G3, G5, G7 Twin Models G6, G10, G14 Type PVC Sch 40 Pipe Recommended - for Main Trunk and Branch Lines Line Size Refer to: Vacuum Plumbing Layout Recommedations, document 004-1130-00. Pump Termination 1 1/2 2 Drain Single Models G3, G5, G7 Twin Models G6, G10, G14 Type Flow Capacity Floor Drain or 1 1/2" PVC Sch 40 P-Trap Minimum 25 Gallons per Minute Tank Wash Supply 3/4"" Garden Hose Fitting Provided per Tank for Non-Permanent Supply Water Connection Boxes Single Models G3, G5, G7 Twin Models G6, G10, G14 User Supplied Fused Disconnect Switch Box : Boxes) to be located within 6 of Vacuum Unit(s). Supply (1) 208-230 Volt, Single Phase, 60Hz (2) 208-230 Volt, Single Phase, 60Hz 1 @ 30 AMP Required 2 @ 30 AMP Required Supply Leads Single Models G3, G5, G7 Twin Models G6, G10, G14 Leads (10 GA Wires) (1) 6 Supply Conduit Provided (2) 6 Supply Conduits Provided Temperature Single Models G3, G5, G7 Twin Models G6, G10, G14 Equipment Room Vent Continuous-run 800 CFM Fan Continuous-run 1600 CFM Fan Equipment Room Ambient Temperature 40 to 104 F 4 to 40 C : All PowerVac G models are recommended to be installed and operated in a thermostatically or otherwise stable ambient temperature environment. Forced air and HVAC input should be used in addition to an exhaust fan if normal ambient temperatures vary from specified operating temperature range. 5

PowerVac G Site Requirement Layout - Elevation View See Exhaust Installation located in this manual for more details. (Provided by Plumber) Roof Disconnect Box 230V 30 AMP Single Phase 60 Hz Circuit with approved ground required. 1 EA motor (2 in system shown) (Provided by Electrician) If Hard Plumbed Vent per Local Codes (Provided by Plumber) Roof Disconnect boxes mounted within 3 Max of each other and 3 of installation centerline. OR Drain OR Operatory Trunk Line Terminate in 2 Pipe Stub for Twin unit. (Single unit - 1 1/2 ) Plastic PVC Sch 40 (Provided by Plumber) 6-12 AA2253-1 1 1/2 P-Trap With 1 Air gap or Floor Sink (Provided by Plumber) 2 MAX. Ventilation required for room to remain in the range of 40 to 104 F or 4 to 40 C with 4500 BTU/HR equipment heat input. Twin Unit Shown, a single unit only requires one disconnect box. 6

Plumbing & Exhaust Installation for Single Models Use Elbow Only if Needed to Connect to User Supplied Exhaust Line Exhaust Drain Assembly Connect Poly Tube to Exhaust Assembly and Route to Drain Out to Vent Inlet Hose Black-Rubber Exhaust Hose Connect to Operatory Verify all local codes before installing Inlet and Drain hoses. Termination of hoses to be provided by installer. Connections must be hand tight. May use mild soap for hose connections. Do NOT use glue on hose connections. Use glue ONLY on PVC connections. Level Base Drain Hose Fans Pressure Sensor Float Back View Single Unit Install.. A) Use wrench supplied to loosen nut on leveling feet located in each corner, lower feet so casters are raised off floor. B) Use a level to level the base front to back and side to side by adjusting the leveling feet. B) Remove back cover then set to side. Do not unplug fan cords. C) Plug in pressure sensor, float, and parallel cord. (Parallel is for twin models only.) D) Connect inlet from base unit to separator. E) Connect hose from separator to operatory. F) Connect drain hose to separator and out to drain. G) Assemble exhaust drain assembly. Connect assembly to exhaust hose and to user supplied exhaust line to vent. H) Replace back cover. Front View AA2247-1i (Wrench Supplied) : Do not cut or shorten hose, High Temp. 7 (Continue with Single Model on Electrical Connections Page)

Exhaust Install - Twin Models Pressure Sensor Use Elbow Only if Needed to Connect to User Supplied Exhaust Line Out to Vent Brass Tee Reducer Barbed Fitting Verify all local codes before installing Inlet and Drain hoses. Termination of hoses to be provided by installer. Black-Rubber Exhaust Hose Connections must be hand tight. May use mild soap for hose connections. Do NOT use glue on hose connections. Use glue ONLY on PVC connections. Parallel Float Fans Parallel AA2254-1 (Wrench Supplied) Twin Unit Plumbing... A) Lower level feet on base unit. Loosen nut on feet to lower leveling feet and raise casters and base unit off floor. B) Remove back covers, set to side, do not need to unplug fan cords. C) Plug in pressure sensor, float and parallel (twin models only). D) Install a reducer and barbed fitting into each end of brass tee. E) Connect two black-rubber exhaust hoses from base unit to barbed fittings. F) Assemble exhaust drain assembly. Connect assembly to exhaust hose and to user supplied exhaust line to vent. F) Replace back covers. : Do not cut or shorten hose, High Temp. Continue with Twin Model on Page 9 When working on twin units (replacements or adjustments), unplug parallel harness. 8

Plumbing Install - Twin Models Verify all local codes before installing Inlet and Drain hoses. Termination of hoses to be provided by installer. Connections must be hand tight. May use mild soap for hose connections. Do NOT use glue on hose connections. Use glue ONLY on PVC connections. Tee Bracket Tee Assembly Connect to Operatory Inlet Hose Twin Unit Plumbing Continued.. A) Mount tee assembly bracket, place tee assembly on bracket. B) Connect inlet hose from base unit to separator. C) Connect inlet hose from each separator to tee assembly. D) Connect inlet hose from tee assembly to operatory E) Connect each drain hose to drain hose connector and out to drain. F) Connect each drain hose to drain tee assembly. G) Connect main drain hose to tee and out to drain. AA2246-2 (Continue with Twin Model on Electrical Connections Page) Drain 9

Electrical Install - ALL Models Electrical Connections... A) Connect remote panel wires to low voltage control wires. B) Hard wire power supply conduit (back of base unit) to user supplied electrical boxes). : Refer to Control Panel Cross Wiring chart to connect Low Voltage wires. Pump must have line voltage present and be turned on & off with the low voltage circuit in order for the timer to work properly. DO NOT modify the length of the cables used on the seperator tank floats or the pressure sensor. Control Panel Cross Wiring Low Voltage Control Wires Brand Wire A B (Light) C Midmark Blue White Red Air Techniques Yellow Brown Orange Den-Tal-Ez Black Brown Yellow Matrx Red Blue White 230 Volt Source, Single Phase, 60 Hz Recommended - 30 Amp Fuse Disconnect Box (Electrician Supplied) Green/Yellow = Ground One Black & One Red (Hot Wires) Connect to 230 Volt Electrical Supply All vacuum systems are to be installed according to local electrical codes. Never operate the equipment without complete and proper grounding. Refer to specification sheet for electrical ratings in this manual. AA2248 10

Installation for ALL Models - Check and Test WARNING The On/Off switch controls only the secondary circuit power. The main power source must be turned off to remove all power in the control box. Too high vacuum level can cause injury and or operatory equipment failure. Do Not introduce foaming cleansers into vacuum system Max To Equipment Room Add From Operatory To Test... A) Check gear lube level on site glass. Add if below 1/3 full. Only use Midmark lube, PN 064-0028-01. B) Start Vacuum. C) Spray soapy water to check for leaks on external plumbing parts. D) Check the vacuum gauge. Vacuum level range is 6 Hg to 18 Hg. E) Vacuum 1-2 gallons of fresh water into system through operatory lines. Run vacuum for 15 min. F) Turn vacuum off and ensure that water drains from separator without leaks. : Vacuum will not run without front cover. On/Off Switch Midmark recommends operation at factory preset of 12 Hg. If reading is low check for leaks or open operatory lines prior to adjusting. 11

Vacuum Adjustment note When working on Twin units, unplug parallel harness. Adjust Vacuum Level (Only if needed)... note: Adjustment can only be made if unit is running and not in sleep mode. If unit is in sleep mode, turn unit off and back on before making adjustment. Unit will enter back into sleep mode in 60 seconds. Adjust vacuum level ( Hg) by... A) Press the ESC button until V xx shows on the screen. B) Press Enter to enter the vacuum setting. C) Press the right arrow to highlight the number you would like to change (fl ashing number is selected). D) Use up and down arrows to change the fl ashing number. E) Press Enter to confi rm the vacuum setting. F) To get back to displaying the pressure value, press the ESC button until the V xx shows on the screen. G) Press the up or down arrows until you see Mon on the display. Press enter. H) Press up or down to select U8-02, press enter. Pressure value should appear on the display. Vxx xx is a Variable Reading Mon Reading U8-02 Reading AA2326 AA2327 AA2328 note Vacuum level range is 6 Hg - 18 Hg. Midmark recommends operation at factory preset of 12 Hg. If reading is low check for leaks or open operatory lines prior to adjustment. 12 Installation is Complete

PowerVac G Specification Sheet Classifications: Class 1, Type B Applied Part Model Max Users Base Unit HxWxD Separator HxWxD Actual Weight (LBS.) Total HP Voltage Amps Hertz Recommended Breaker Size (Amps) Inlet Connection Size (IN.) Fuses Drain Connection Size (IN.) G3 3-5 26 x 19.5 x 18.5 34 x 22 x 22 Base Unit - 375 Separator - 49 3 208-230 20 60 30 1 1/2 1/8 A, 250V Type T 1 1/2 G5 5-7 26 x 19.5 x 18.5 34 x 22 x 22 Base Unit - 375 Separator - 49 3 208-230 20 60 30 1 1/2 1/8 A, 250V Type T 1 1/2 G7 7-10 26 x 19.5 x 18.5 34 x 22 x 22 Base Unit - 375 Separator - 49 3 208-230 20 60 30 1 1/2 1/8 A, 250V Type T 1 1/2 G6 6-10 26 x 19.5 x 18.5 (qty 2) 34 x 22 x 22 (qty 2) Base Unit - 375 Separator - 49 6 208-230 40 60 2 x 30 2 1/8 A, 250V Type T 1 1/2 G10 10-14 26 x 19.5 x 18.5 (qty 2) 34 x 22 x 22 (qty 2) Base Unit - 375 Separator - 49 6 208-230 40 60 2 x 30 2 1/8 A, 250V Type T 1 1/2 G14 14-20 26 x 19.5 x 18.5 (qty 2) 34 x 22 x 22 (qty 2) Base Unit - 375 Separator - 49 6 208-230 40 60 2 x 30 2 1/8 A, 250V Type T 1 1/2 Verify all sides of base unit are not obstructed. Recommended - 6 inches on left and back side. Required - 12 inches on front and right side. 13