Welsh Government Consultation: Renting Homes (Wales) Act 2016 Fitness for Human Habitation Response from ARLA Propertymark January 2018 Background

Similar documents
Consultation on Fire and Smoke Alarms in Scottish Homes

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Proposed Social Housing (Automatic Fire Suppression Systems) (Scotland) Bill Shelter Scotland consultation response

Manifesto for the 2017 General Election: Preventing deaths and injuries in the home

5 Sadly, recent tragic events in South Yorkshire saw a two year old girl, Libby- Jayne Hornsby lose her life in a house fire in Conisbrough.

Smoke Alarm Legislation

Consultation on Fire and Smoke Alarms in Scottish Homes: Analysis of Responses PEOPLE, COMMUNITIES AND PLACES. social. research

Fire safety and high rise student accommodation

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Carbon Monoxide Safety

Shelter submission to the DCLG review of the Smoke and Carbon Monoxide Alarm (England) Regulations 2015

November 17, Sent Via Electronic and Regular Mail

ABOUT NATIONAL ENERGY ACTION

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

Weatherization Assistance Program (WAP) Space Heater Policy

Professional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

Information Guide Maintenance and Refrigerant Regulations. Issue 35

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Preventing deaths and injuries in the home in Scotland

Gas Safety-Landlords Responsibilities

Domestic and Residential Fire Sprinklers Design Policy

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: EQUALITY ACT 2010

Melrose Fire Department

Fire precautions in dwellings

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

The story so far. We ve been developing Firemark Education with colleagues from DCLG and the government for two years to date.

Fire Safety Protocol

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

ELECTRICAL FIRE SAFETY

UK HOUSEHOLDERS SPEND 16.6 BILLION ON HOME MAINTENANCE IN 2008

WELSH GOVERNMENT SPRINKLER PILOT STUDY

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

FIRE SAFETY LOG BOOK

Fire Safety Policy (Communal Areas)

NOTTINGHAM CITY HOMES

ADVICE NOTE FIRE SAFETY IN FLATS. A general guide to fire safety in blocks of flats

SHORELINE, FLOOD AND COASTAL DEFENCE MANAGEMENT PLANS

Safety Alert New Gas Regulation 2013

Response to call for evidence for Independent Review of Building Regulations and Fire Safety. October 2017

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

Carbon Monoxide Alarm Update

LANDLORD S GUIDE. The Landlord s Guide to the Gas Safety Regulations Electrical Equipment (Safety) Regulations Who must comply?

Recent Revisions and Proposed Key Changes to Fire Code

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

Township of Maplewood

HOLLY HILL FIRE DEPARTMENT

Fire risk your responsibility?

Implementing the Domestic Fire Safety Regulations 2013

Carbon monoxide Knowing more

Proposed clause wording to come in from 1 September August 2018

19 th October FAO Paul Lewis Planning Policy Branch Planning Division Welsh Assembly Government Cathays Park Cardiff CF10 3 NQ

Ways we can help. Making your energy easy

STATE OF MAINE Department of Public Safety Office of State Fire Marshal 52 State House Station Augusta, ME

Welcome to your new home

Knight Frank Interior Services

Balcombe Neighbourhood Plan. Habitats Regulations Assessment Screening Report

Circulation Report for SIG-TMS Comments Document # 72

Safety. in all our homes MONITORED BURGLAR ALARMS HOME SECURITY INSTALLED FOR COMPLETE PEACE OF MIND INSURANCE BROKERS

LANDLORD INSTRUCTION FORM

Plymouth University - Application for Landlord Registration

Call for Proposals. Heritage, natural capital and ecosystem services: case studies. Project No: Date of Issue: Tuesday 14 th November 2017

Certificate of Continued Occupancy Residential Application

technical specification smoke venting systems

Smoke Alarm Requirements find the article at: "

This block joins with others on each side that contain large amounts of native vegetation and would support a significant number of native fauna.

CYNGOR SIR POWYS COUNTY COUNCIL

ADVICE NOTE GAS SAFETY. How you can stay gas safe in your flat

Risk Assessment and Control Measures for Household Hot Water Systems

From the Operating Guidance:

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Gas appliances. Keeping them safe

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

PERIODIC ELECTRICAL TESTING POLICY

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System

BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS

Your Questions Answered

Housing Division Notice

7. DOES THE PLAN OR PROJECT NEED AN APPROPRIATE ASSESSMENT?

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

Product Safety Reporting Requirements in the European Union

Fire Risk Assessment Guidance

Building Regulations Update. by Eamonn Smyth

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Lakanal House inquest: Statement from the Fire Sector Federation

Periodic Electrical Testing Policy

A DRAFT ALLOTMENT POLICY FOR STIRLING COUNCIL

carbon monoxide alarms

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Property News January 2017

Royal Surrey County Hospital NHS Trust. A guide to your onsite key worker accommodation

Your guide to a more

Policy for Safe Evacuation of Persons with Disabilities

Sofia Office. Sustainability. Capability brochure

LYHA Fire Safety Policy

Management of Asbestos

Masterplanning. BRISTOL OXFORD. Bagley Croft Hinksey Hill Oxford OX1 5BS Tel: Fax:

Transcription:

Welsh Government Consultation: Renting Homes (Wales) Act 2016 Fitness for Human Habitation Response from ARLA Propertymark January 2018 Background 1. ARLA Propertymark is the UK s foremost professional and regulatory body for letting agents; representing over 9,000 members. ARLA Propertymark agents are professionals working at all levels of letting agency, from business owners to office employees. 2. Our members operate to professional standards far higher than the law demands, hold Client Money Protection and we campaign for greater regulation in this growing and increasingly important sector of the property market. By using an ARLA Propertymark agent, consumers have the peace of mind that they are protected and their money is safe. Questions Q1. Determination of whether a dwelling is FFHH. Do you agree with our approach to determining whether a dwelling is FFHH, in particular referencing the 29 matters and circumstances set out in the guidance? 3. Yes, we agree with the Welsh Government s approach to determining whether a dwelling is FFHH. Q2. Landlord requirements carbon monoxide. Do you agree with the requirement for a landlord to install a carbon monoxide alarm? 4. Yes, we agree with the requirement for a landlord to install a carbon monoxide alarm. Carbon monoxide is known as the Silent Killer because you can t see it, taste it or smell it and it can kill quickly with no warning. Each year carbon monoxide poisoning affects over 4,000 people in the UK. 1 Therefore, it is vital that all privately rented homes in Wales have a carbon monoxide alarm. Q3. Landlord requirements smoke alarms. Do you agree with the requirement for a landlord to install a smoke alarm? 1 http://www.policyconnect.org.uk/appcog/research/carbon-monoxide-poisoning-saving-lives-advancingtreatment

5. Yes, we agree with the requirement for a landlord to install a smoke alarm. The London Fire Brigade warn that people are four times more likely to die in a fire in the home if there is no smoke alarm. 2 Therefore it is vital that every privately rented home in Wales has a fire alarm fitted. Q4. If yes to question 3. Should there be any additional requirements on the type of smoke alarm installed? 6. We do not think at this stage there should be any additional requirements on the type of smoke alarm installed. However, the Welsh Government should monitor the effectiveness of the regulations and upon evaluation potentially seek to bring in additional requirements. Q5. If yes to question 4 which type of alarm should be installed? 7. Should an evaluation of the effectiveness of the regulations demonstrate a strong need for additional regulation, we believe that sealed unit lithium battery-powered smoke alarms with 10-year lifespan should be specified. Q6. Landlord requirements for electrical safety testing. Do you agree with the requirement for a landlord to undertake electrical safety testing? 8. Yes, we do agree with the requirements for a landlord to undertake electrical safety testing. ARLA Propertymark supports measures to increase the standards of electrical safety in order to benefit tenants without introducing excessive regulation and costs for landlords and letting agents. We were a key member of the Department for Communities and Local Government Working Group which was set up to look at how electrical safety testing in England should be implemented and helped shape the recommendations. The private rented sector has undergone rapid growth in the last 10 years and in 2015-16, 14% (201,782) of households in Wales were renting privately. 3 Therefore it s imperative that electrical safety standards reflect the growing importance of the sector. At present electrics in private rented sector properties just have to be safe with no definition as to what this means. Therefore, electrical safety testing rules will give a clear and unambiguous requirement that brings electrical safety more in line with the regulations that apply to gas safety. 2 http://www.london-fire.gov.uk/news/latestnewsreleases_landlords-urged-to-snap-up-freealarms.asp#.wlisrq5l_iu 3 http://gov.wales/docs/statistics/2017/170427-dwelling-stock-estimates-2015-16-en.pdf

Q7. Landlord requirements electrical safety testing. Do you agree that the maximum period between electrical safety testing should be five years? 9. Yes, we agree that the maximum period between electrical safety testing should be five years. This would make the checks consistent with electrical safety standards for Houses of Multiple Occupation and align with standards in Scotland and proposals for England. Checks every five years would also spread the costs for landlords. They would create the right balance between being too burdensome, such as at the start of every tenancy or annually, and not achieving its aims, such as every ten years. Q8. Specific requirements imposed on landlords. Do you agree that the three specific requirements imposed on landlords (installing a carbon monoxide detector, smoke alarm, and undertaking electrical safety testing) address the most important concerns? 10. Yes, we do agree that three specific requirements imposed on landlords address the most important concerns. Q9. Draft guidance on fitness for human habitation. Do you agree that the draft guidelines on fitness for human habitation adequately explains: a) the nature of the 29 matter and circumstances b) the specific requirements placed on landlords by the regulations? 11. Yes, on the whole we agree that the draft guidelines on fitness for human habitation adequately explains the nature of the 29 matters and circumstances. However, in relation to Noise and the Potential Landlord action - Bathrooms/WCs in flats not sited above living rooms/bedrooms, this does not take into consideration the locality of these facilities in flats and nearly all houses. Therefore it would be impossible for landlords to move facilities in houses and impractical for landlords to make adjustments in flats where they do not own the apartment above as well. This action needs to be better explained or removed altogether. 12. In relation to the specific requirements placed on landlords by the regulations, particularly for the installation of smoke alarms and carbon monoxide detectors, the draft guidelines need to clearly define and explain what agents need to do to ensure that the alarms are in proper working order. When similar rules were introduced in England concerns were raised by letting agents and inventory providers that there were no guidelines and so agents have just been pressing the test button. However, it is not clear whether this is enough. Clearer guidance is particularly important for

carbon monoxide detectors because by pressing the test button this only tests the circuitry of the detector, it does not test the actual sensor that lets you know if there is carbon monoxide in the air. Therefore, guidance in Wales needs to be clear and specifically state whether testing the button is sufficient. To this end, to do anything more would put massively onerous requirements on agents, such as using detector testers with an aerosol smoke dispenser. To reduce the chance of confusion in Wales, the guidelines need to provide specific information on what is required. 13. The specific requirements placed on landlords by the regulations should be adequately phased in. The implementation date must ensure that that there are sufficient alarms available for landlords to comply fully. The timetable must also ensure that it is practical for letting agents, many of whom manage large property portfolios, to gain access to the properties and to install these alarms on behalf of their clients in the time frame allotted. To this end, the rules should be brought in for new tenancies first and then all existing tenancies by a later date. 14. The draft guidelines also do not outline when testing of smoke alarms and carbon monoxide alarms should be carried out. To ensure that landlords and letting agents can adequately carry out the tests we believe that there should be a requirement for the alarms to be tested either a fortnight prior or post the start of each new tenancy. This is because agents have large portfolios, many tenants move in on Fridays and they simply cannot get round all the properties they are checking-in. Letting agents must be given a realistic period of time to both be informed of the regulations and also to ensure they are able to implement the rules. Q10. Do you have any further comments to make on the draft regulations, including any on their cost implications? 15. We do not have any further comments to make on the draft regulations. Q11. Welsh Language Impact: Whilst this consultation paper is being made available in Welsh, please can you suggest how the proposed Fitness For Human Habitation Guidance document can be formulated or changes so as to have i) positive effects or increased positive effects on opportunities for people to use the Welsh language and on treating the Welsh language no less favourably than the English language, and ii) no adverse effects on opportunities for people to use the Welsh language and on treating the Welsh language no less favourably than the English language.

16. In light of the impact of recent legislation, tax changes for landlords and the Welsh Government s announcement that they will ban letting agent fees to tenants, agents need to cut costs so will be unwilling to go to additional expense of making everything bi-lingual. Therefore, without a free translation service provided by the Welsh Government to help with legislative changes there will be a negative impact on the Welsh language as agents will only deal in English.