BOP Management System Information

Similar documents
Dependable Solutions for Gas Detection

ClampOn DSP Corrosion- Erosion Monitor

OPTIBAR DP 7060 Supplementary Instructions

GasAlertMicroClip X3 Specifications

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

ALTAIR 5X Multigas Detector Product Specification

your dust explosion protection experts

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

INSTRUCTION MANUAL A131 High Level Audible Warning System

805QS Pressure Switch-Transmitter

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Maglink consoles Site manager & top level software Filling stations and fuel depots management MAGNETOSTRICTIVE & WIRELESS TECHNOLOGY

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Isco 3700ZR Sampler. Manual Set

INTRODUCTION / TABLE OF CONTENTS

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Description. Applications

Combi B Alarm box. Mounting instructions

DTS Light fittings for explosive atmospheres

Vanguard. Toxic & combustible gas detector

Beacon 800 Gas Monitor Operator s Manual

PANELBOARD PROTECTION ON A GLOBAL SCALE

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

PURGE/PRESSURIZATION SYSTEM

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

official distributor of Newson Gale Ltd.

ClampOn DSP Pig Detector

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Manual Power relay SR853

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

MBCE-110/230FR Flame Sensor Module

GIRTON CABINET WASHER MODEL 794A

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Industrial Signalling

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Fisher LCP100 Local Control Panel

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Commercial and Light Industrial Fire Alarm Control Panel

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

Quick Start Guide For the

Design Manual Installation Operation Maintenance

INTRINSICALLY SAFE LIGHTING RANGE

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

Comfort. Description. Applications

Survey of electrical equipment installed in hazardous areas on tankers

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

TELECOMMUNICATION. Telecommunication. Wireless Phone

S5000 Gas Monitor. GMS5000.com

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

INSTRUCTION & SERVICE MANUAL

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

Rosemount 2051T In-line Pressure Transmitter

Dräger X-zone 5500 Area Monitoring

PROTÉGÉ ZM SINGLE GAS MONITOR

Rosemount 3490 Series

OPTIMUM APPLIED SYSTEMS,

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Certificate of Compliance

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

Wall-Mount Preferred-Cutout Disconnects Hoffman WATERSHED Wall-Mount Disconnects

AO Annunciator Module

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES SENSING BUMPERS INTERFACE CONTROLLERS LIGHT CURTAINS CUSTOM DESIGNS

OILFIELD INSTRUMENTATION & CONTROL SYSTEMS. Rig Control Products Ltd

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

WAVE SEQUENCER DELIVERS:

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

OPTIBAR P 1010/2010 C Supplementary instructions

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

ColorMax Cyclone Cleaning Kit

ULTIMA X5000. MSAX5000.com

W1/B, O, W2/E, Y1, Y2, G. Gas or electric. Wireless, 915MHz, proprietary protocol. Up to 100 feet 24VAC, 2.4VA. Molded plastic

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Dräger X-zone 5500 Area Monitoring

Rosemount 2051T In-Line Pressure Transmitter

LTFX Electric Tank Immersion Heaters Installation Instructions

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

SYSTEMS PRODUCT OVERVIEW

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

GS01 (wireless) Detection of flammable gases and vapours

standards: standards:

Steam Humidifier Models 1150 and 1160

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Mustang Vaporizer. Installation, Operation & Maintenance MV

Direct Fired Heater Model AD Specification

Transcription:

BOP Management System Information V 1.0 June 10, 2015

Table of Contents Display Panel... 3 Power Disconnect... 5 Pneumatic Override (Optional)... 7 Foot Pedal Transducer (Optional)... 9 BOP Ram Sensor... 11 LED Indicator... 13 Warning Station... 15 Pressure Sensor... 17 Commissioning, Testing and Training... 19 2

Display Panel Install Time Rig Status Requirements QUICK FACTS 30-60 Minutes Racked, Moving or Operating Location selected by Rig Manager. 12 VDC - 24 VDC power Description of Function: The panel is the main display, wireless receiver and control module for the Rigsmart BOP Management System. Sensor transmissions are received through the panel and clearly displayed for the operator. The panel is where BOP logic is loaded, and is the main controller for dumping air and alarming events. Location: The panel is located in the doghouse (or supervisor specified area) and can be mounted to any fixed surface. It is designed for outdoor use in all weather conditions. Rig Requirements: Rig Status The panel is installed while the rig is racked. A 12 VDC - 24 VDC power source from the rig to the Rigsmart power disconnect is required, and technicians must have access to the doghouse (or other specified mounting location). Crew Responsibilities The supervisor should provide a location preference for the panel. Time Required 30-60 minutes is required for panel mounting and setup. Antenna and configuration requirements may vary according to the chosen panel location. 3

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Display Panel Data Sheet Overview The main display, wireless receiver and control module for the Rigsmart BOP Management System. Sensor transmissions are received through this panel and are clearly displayed for the operator. The Panel is also where BOP logic is loaded, and is the main controller for dumping air before a collision occurs, and alarming the crew. The panel is typically mounted in the doghouse. Operating time 100% (continuous duty) Voltage type 12-24 VDC, 7.5A normal operating range (can accept 11-32 VDC) Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection Woodhead, bulgin or amphenol Mounting options Bolt on bracket Hazardous locations Class 1 Division 2 Ex na IIB+H2 T4 Certified to: IEC CAN/CSA E60079-15:02 Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 4

Power Disconnect Install Time Rig Status Requirements QUICK FACTS 15 Minutes Racked, Moving, Operating Location selected by Supervisor. 24 VDC power Description of Function: The Power Disconnect is the main on/off switch for the Rigsmart System. The box requires a 24 VDC power source, either provided directly from the customer or from a power converter box provided by Rigsmart Systems. Location: The box is located in the doghouse (or other specified location) and can be mounted to any fixed surface. It is designed for outdoor use in all weather conditions. Rig Requirements: Rig Status The panel is installed while the rig is racked. A 24 VDC power source from the rig to the Rigsmart power disconnect is required, and technicians must have access to the doghouse. Crew Responsibilities The Supervisor should provide a location preference for the power disconnect. Time Required 15 minutes is required for mounting and setup. Configuration requirements may vary according to the chosen panel location. 5

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Power Supply Data Sheet Overview The Rigsmart Power Supply Box runs on a standard 120 VAC 240 VAC source provided by the customer, and outputs 24 VDC for the use of the Rigsmart System components. Operating time 100% (continuous duty) Voltage type Input: 120 240 VAC Output: 24 VDC Operating temperature -40 C to +60 C Construction - 16 gauge steel body and cover - Welded seams without knockouts or holes - Seamless poured-in place gasket - Door includes a quarter turn slot for added safety Connection Bulgin Mounting options Bolt on bracket Hazardous locations Ex II 3 G Ex na nc IIC T4 Gc TÜV 11 ATEX 079480 X Ex na nc IIC T4 Gc IECEx TUN 11.0007X Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 6

Pneumatic Override (Optional) Description of Function: Install Time Rig Status Requirements QUICK FACTS 1 Hour Racked Access to the air or electrical system A pneumatic or electric throttle control box is connected to the service rig, drilling rig or snubbing unit power pack. When the rams are closed, the system will kill throttle to prevent the rig from pulling into the closed rams. The component is paired with a throttle override pedal for bypass. Location: The pneumatic or electric throttle control box is connected to the service rig, drilling rig or snubbing unit power pack. It is used to interrupt the throttle airline or electric control line. Rig Requirements: Rig Status - The rig should be racked, with the air or power de-energized. The Rigsmart technician requires access to the air or electric throttle system. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations. Time Required - Can be installed in approximately 1 hour. 7

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Pneumatic Override Data Sheet Overview The Rigsmart Pneumatic override will cut the operators throttle in the event of an alarm. The override can be bypassed and throttle restored at a reduced rate if the operator actuates the wireless foot pedal. Once the alarm condition clears, the override releases control of the operators throttle. Operating time 100% (continuous duty) Voltage type 12 or 24 VDC Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Hot compression molded fiberglass reinforced polyester (thermoset) Connection ¼ NPT Mounting options N/A Hazardous locations All internal components are rated for Class1 Division 2 Environmental Ingress Protection IP67 Application Snubbing Units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 8

Foot Pedal Transducer (Optional) Description of Function: Install Time Rig Status Requirements QUICK FACTS N/A N/A N/A The Wireless Foot Pedal provides a way for the operator to move the string at a reduced speed when an alarm condition is present. The device is wireless so it can be easily moved to wherever the operator is standing. Location: Normally on the driller s platform but the device can be placed anywhere, due to its wireless nature. Rig Requirements: Rig Status No special access is required. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations. Time Required N/A 9

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Foot Pedal Transducer Data Sheet Overview The Rigsmart Wireless foot pedal will restore limited throttle to the operator during an alarm condition. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Body material Ultramid 8333G Hi- Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Foot pedal to be placed near operator Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E60079-11:02 Environmental Ingress Protection IP67 Application Snubbing Units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 10

BOP Ram Sensor Install Time Rig Status Requirements QUICK FACTS 30 Minutes Racked, deenergized BOP access and custom bracket Description of Function: The BOP Ram Sensors detect whether or not the rams on the BOP stack are in the open or closed position. The sensors come in sets of two (one for each ram side) and work in conjunction. The transducer is made up of a proximity sensor that can detect when a metal object is close to it or not. The panel identifies that the ram (and which side) has been closed. Location: The sensors are mounted on the very end of the ram. When the ram is open, the end of the ram shaft is positioned ¼ away from the sensor s pickup. Rig Requirements: Rig Status - The monitored equipment needs to function after installation, for testing purposes. Crew Responsibilities - Some minor assistance from the crew may be required in testing operations, and creating a mount location. Time Required - Sensors can be installed in approximately 1 hour, once the mounts are fabricated. 11

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* BOP Ram Sensor Data Sheet Overview The Rigsmart BOP Ram Sensor is a proximity device which detects the presence of the BOP polish rod. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Brackets fabricated for various BOP s Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E60079-11:02 Environmental Ingress Protection IP67 Application Snubbing units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 12

LED Indicator Install Time Rig Status Requirements QUICK FACTS N/A N/A N/A Description of Function: The LED Display is a visual indicator for the ram sensors. Each LED is paired to a specific set of rams, and will flash either red (for closed ram status) or green (for open), as indicated by the sensors. Location: The sensors are magnetically mounted, and can be placed wherever the operator has a direct line of sight to the device. Rig Requirements: Rig Status N/A Crew Responsibilities N/A Time Required N/A 13

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* LED Indicator Data Sheet Overview The Rigsmart LED indicator visually displays the BOP status. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options Magnetic mounting bracket Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E60079-11:02 Environmental Ingress Protection IP67 Application Snubbing units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 14

Warning Station Install Time Rig Status Requirements QUICK FACTS 1.5 2 hours Racked Access to doghouse and de-energize electric system Description of Function: The Warning Station receives status from the display panel on the BOP and accumulator system. Red indicates a closed ram, green indicates an open ram, and yellow indicates low accumulator pressure. The warning station also has two horns that sound different audible alarms, based on the status of the rams or accumulator. Location: The device is mounted on top the doghouse, or other supervisor specified area. Rig Requirements: The electric system needs to be de-energized, and access to the doghouse is required. Rig Status Racked Crew Responsibilities Assistance with the installation location may be required. Time Required 1.5 2 hours 15

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Warning Station Data Sheet Overview The Rigsmart Warning station can be equipped with ram closed strobe, ram open strobe, accumulator pressure low strobe and alarm horns for BOP closure and accumulator low pressure. Operating time 100% (continuous duty) Voltage type 12-24 VDC Operating temperature -40 C to +60 C Construction - 16 gauge steel body and cover - Welded seams without knockouts or holes - Seamless poured-in place gasket - Door includes a quarter turn slot for added safety Connection Certified electrical connection Mounting options Custom for alarm station location Hazardous locations Alarm station is typically not mounted in the classified zone. Environmental Ingress Protection IP67 Application Drilling rigs, Service rigs, Snubbing units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 16

Pressure Sensor Install Time Rig Status Requirements QUICK FACTS 30 minutes Racked Hammer Union or Nipple Description of Function: A wireless component which measures fluid or gas pressure directly off of pipes and transmits the reading back to the main display panel. Location: Can be connected to any ½ NPT port or configured to any custom connection. A Hammer Union or ½ port is required. Rig Requirements: Rig Status Racked Crew Responsibilities Provide assistance with installation location. Time Required 30 minutes 17

*Information subject to change without notice. Consult the factory for the most current data and part numbers.* Pressure Sensor Data Sheet Overview A wireless component which measures fluid pressure directly off of pipes and transmits the reading back to the main display panel. They are available in 100, 3,000, 5,000, 10,000, and 15,000 PSI models. Operating time 100% (continuous duty) Voltage type Powered by a 3.6 volt D cell lithium battery Operating temperature -40 C to +60 C Operating Frequency Range 900-928 MHz in North America 868-870 MHz in Europe Material Body material Ultramid 8333G Hi-Polyamide 6 Seals ROHS compliant silicon rubber, 60 durometer shore-a, compound # SIM40160 Connection No connection, component provides a wireless signal Mounting options 1/4 NPT, 1/2 NPT, hammer union, custom Hazardous locations Exia IIB T4 Intrinsically Safe per IEC CAN/CSA E60079-11:02 Environmental Ingress Protection IP67 Application Drilling Rigs, Service Rigs, and Snubbing Units Rigsmart Systems, Inc. 4908 97 St. Edmonton, AB T6L 4B2 Ph: 780.438.9475 Email: info@rigsmart.com 18

Commissioning, Testing and Training Install Time Rig Status Requirements QUICK FACTS Various Operating Driller, Rig Manager, operator, supervisor and any personnel requiring training Description of Function: Commissioning, testing and training are considered the most important part of the installation procedure. Calibrations are vital to optimal system performance, and each component must be proven to interact with the panel software as it was designed, for each specific unit. It is Rigsmart s goal is to train operators and crews to use and maintain their own systems safely and effectively. Collision and zone management limits are set and adjusted with the rig crew s input and cooperation. Post installation service is available 24/7, but through adequate training many service related issues can be avoided. Rig Requirements: Rig Status The rig must be operational and able to provide a full function test. Crew Responsibilities A driller or Rig Manager is required to operate the different functions of the rig such as raising or lowing the blocks, link-tilt or moving the top drive. The crew will also be required to provide input on collision limits for the system. Time Required- Testing each component can take up to 30 minutes per component. Commissioning the full system may take up to 4 hours, depending on the situation. Training the Rig Manager and crew may take anywhere between one hour of instruction to several days of operational-drilling tutorials. 19