Bottom Mount Refrigerator---Technical Information

Similar documents
AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

CAUTION. No-Load Performance, Controls in Normal Position

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Bottom Mount Refrigerator Technical Information

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

FOR SERVICE TECHNICIAN S USE ONLY

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

Image Key Part Number Description Substitution Qty.

FOR SERVICE TECHNICIAN S USE ONLY

Image Key Part Number Description Substitution Qty.

SERVICE NOTEBOOK BUILT-IN REFRIGERATOR VCSB481 / VCSB482

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

Side-by-side combined refrigerator-freezer

Fast Track Troubleshooting

Fast Track Troubleshooting

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Fast Track Troubleshooting

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

T-32-TS Touchscreen Thermostat. Installation Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

3. OPERATING INSTRUCTIONS & INSTALLATION

Ice Maker (Fresh Food Compartment)

Fast Track Troubleshooting

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

2010 Whirlpool 26 SXS Refrigerators

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Upright S-Series. hoshizakiamerica.com

4. ALIGNMENT AND ADJUSTMENTS

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

Product Information and Technical Guide

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

REACH-IN SAFETEMP (-AAC)

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

Liebert InteleCool Warranty Inspection Check Sheet

Product Information and Technical Guide

Prodigy Flaked and Nugget Ice Machines Technical Review

User Guide ems25plus. Page 1. Normal operation. Product interface

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

Instruction Sheet

Super-Flo Low Profile Unit Cooler

Hoshizaki America, Inc.

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Product Information and Technical Guide

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

User s Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

MODEL URS-1: FACTORY RETROFIT PROGRAM

-30 C Undercounter Plasma Freezer

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

HPXA19. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

PACKAGE AIR CONDITIONER

MACH N-407 Heat Pump Air-Cooled Chiller

Service Documentation

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

Installation Instructions

MFM-9TP MFM-9TPW INSTRUCTION MANUAL. Microwave Oven TABLE OF CONTENTS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

SCN60 Residential Nugget Ice Machine

Fast Track Troubleshooting

TEMPERATURE & PRESSURE CONTROLS

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

Portable Refrigerator

SERVICE NOTEBOOK Side-by-Side Refrigerators

INSTALLATION INSTRUCTIONS

Norcold Repair Guide for Ice Maker

KM-630MAH KM-630MWH KM-630MRH

Peachtree City is home office for America located about 30 miles south of the Atlanta airport this is were all KM cubers as well as Flakers are built.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Transcription:

Bottom Mount Refrigerator---Technical Information WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operation. Failure to do so can result in death or electrical shock. No-Load Performance, Controls in Normal Position Kw/24 hr ±0.4 Percent Run Time ±10% Cycles/24 hr ±25% Refrigerator Center Compartment Average Food Temperature ±3 F Freezer Compartment Average Food Temperature ±3 F Ice Maker Compartment Average Temperature ±5 F Ambient F 110 110 110 110 110 110 20 cu ft 1.2 2.0 2.6 38 55 80 25 22 25 38 38 38 0 0 0 15 15 15 22 @ 25 cu ft 1.2 2.0 2.6 38 55 80 25 22 25 38 38 38 0 0 0 15 15 15 Temperature Relationship Test Chart Evaporator Outlet ±3 F Evaporator Inlet ±3 F Suction Line ±7 F Average Total Wattage ±10% Suction Pressure ±2 PSIG Head Pressure ± 5 PSIG Ambient F 25 cu ft -20-17 -20-17 85 105 145 150 0 0 83 135 22 @ 25 cu ft -20-17 Schematic -20-17 85 105 145 150 0 0 83 135 1 12827955 02/07

Component Specifications Component Compressor run capacitor Compressor Electric damper control Thermistor Condenser motor Evaporator fan motor Overload/Relay Thermostat (Defrost) Evaporator heater Control board Dual Water Valve Ice Box Fan Light switch Specifications all parts 115VAC/60HZ unless noted Volt... 220 VAC Capacitance... 15 fd 10% BTUH... 730 BTUH Watt... 60 Hz / 153 watts Current Lock rotor... 19.0 amps± 15% Current Full load... 1.09 amps± 15% Resistance Run windings... 3.33 ohms± 15% Resistance Start windings... 4.28 ohms± 15% Maximum closing time... 8 seconds Temperature Rating... 20 F- 110 F RPM... 4.2 Temperature... Resistance 77 F... 10,000 ohms± 1.8% 36 F... 29,500 ohms± 1.0% 0 F... 86,300 ohms± 1.8% Rotation (facing end opposite shaft)... Clockwise RPM... 1120 RPM Watt... 3.4 watts±15%@115vac Current... 0.085 amps± 15%@115VAC Rotation (facing end opposite shaft)... Clockwise RPM... 3000 RPM Watt... 5.5.9±15% watts@12 VDC Note: Fan blade must be fully seated on shaft to achieve proper airflow. Ult. trip amps @ 158 F (70 C)... 2.40 amps± 15% Close temperature... 142 F ±9 Open temperature... 284 F ±9 Short time trip (seconds)... 17 seconds ±5 Short time trip (amps @77 F (25 C)... 12 amps ±2amps Volt... 120/240 VAC Watt... 495 watts Current... 5.8/3.75 amps Resistance across terminals: 56 K ohms Above 42 F ±5... Open Below 12 F ±7... Closed Volt... 115 VAC Wattage... 470 ±5% watts @ 115VAC Resistance... 29 ±5% ohms Volt... Watts... Blue side 35w,Yellow side 20w Rotation (facing end opposite shaft)... Clockwise RPM... 3000 RPM Watt... 5.5.9±15% watts@12 VDC Note: Fan blade must be fully seated on shaft to achieve proper airflow. Type... SPDT NO/NC Volt... 125/250 VAC Current... 5.0 amps 120VAC, 60 HZ See Control board troubleshooting section 2 12827955 02/07

Service Specifications Programming Mode: NOTE: The Program Code is located on the Serial Plate on this unit after the word Code. 1. Press and hold the Alarm Keypad. Alarm 2. Press and hold Freezer Temperature Down Keypad. 3. Release the Alarm Keypad and wait 3 seconds. Alarm 4. The control will display PE to indicate the programming mode. 5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more. 6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate. NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Alarm Keypad for 3 seconds. 7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to change the digit value with each key press. 8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit. 9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad until the Program CODE begins flashing indicating it has been saved. NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated. The Programming mode can be exited at any time by pressing Alarm key for 3 seconds or will exit if unattended for four minutes. 3 12827955 02/07

Service Specifications Defrost Operation: The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. Forced Defrost Mode: The forced defrost function is performed using the Freezer display and Refrigerator keypad. Enter the Forced Defrost Mode by performing the following sequence of events: 1. Press and hold the Alarm Keypad. 2. Press and hold Refrigerator Temperature Down Keypad. 3. Release the Alarm Keypad Alarm and wait 3 seconds. Fd appears in Freezer display. 4. Press the Refrigerator Down Keypad again. Sh appears in right display. 5. Press again to force defrost Fd and Sh will flash in display indicating unit is in defrost. Service Test Mode: The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode by performing the following sequence of events: 1. Press and hold the Alarm Keypad. 2. Press and hold Refrigerator Temperature Up Keypad. 3. Release the Alarm Keypad Alarm and wait 3 seconds. 4. The Freezer display will display SE confirming entry in the Service Mode. 5. Press the Refrigerator Up Keypad again to confirm entry in the Service Mode. 6. Display will show 101 in left display and numeric or dashes in right display. 7. Press Freezer Up Keypad and Freezer Down Keypad to toggle through Service Test numbers. Service Test - 101 Defrost Heater & Defrost Circuit Press the Refrigerator Up keypad and Refrigerator Down keypad to energize or de-energize the Defrost circuit. The display will read OFF when de-energized, OP when energized with open defrost thermostat and CL when energized with closed defrost thermostat. Service Test - 102 Compressor / Condenser Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Compressor/Condenser fan On and Off. 4 12827955 02/07

Service Specification Service Test 112 Freezer Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Freezer Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 113 Ice Compartment Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Ice compartment Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 121 Damper Operation Press the Refrigerator Up keypad and Down keypad to toggle Damper (OP) open and (CL) closed. NOTE: If damper is opening or closing it will not allow you to toggle damper and beep. Display will show state CL or OP if Damper is in the process of closing or opening. Service Test 131 Mullion Heater Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Mullion Heater Off and On. Service Test 141 Fresh Food Thermistor Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 144 Ambient Thermistor Will Show AmbientTemperature or, OP open thermistor or SH shorted thermistor. Service Test 145 Ice Box Thermistor Will Show Ice BoxTemperature or, OP open thermistor or SH shorted thermistor. Service Test 151 Fresh Food State Will show state of Fresh Food. OP (open) CL (closed). NOTE: By pushing either fresh food door switches you can toggle state from OP (open) to CL (closed). Service Test 152 Freezer Food State Will show state of Freezer. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle state from OP (open) to CL (closed). Service Test 153 Disable Internal Lights Press the Refrigerator Up keypad and Down keypad to toggle Enable (En) and Disable (dis) internal. 5 12827955 02/07

Service Specification Service Test - 161 Cube Dispenser Display shows the state of the Ice Auger Motor (ON or OFF). NOTE: By pushing Actuator pad you can control state of the Ice Auger Motor without opening Ice Chute door. Service Test - 163 Water Dispenser Display shows the state of the Water Dispenser Valve (ON or OFF). NOTE: By pushing Actuator pad or Front fill you can control state of Water Dispenser Valve. Service Test - 164 External Ice Chute Display shows the state of the External Ice Chute CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of External Ice Chute. Service Test - 165 Dispenser Lamp Display shows the state of the Dispenser Lamp (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can control state of dispenser lamp. Service Test - 166 Internal Ice Chute Operation Display shows the state of the Internal Ice Chute CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of Internal Ice Chute. Service Test - 167 Cavity Heater Test Display shows the state of the Cavity Heater ON or OFF. Service Test - 171 Actuator Pad Display shows the state of the Actuator Pad (ON or OFF). Service Test - 172 Bottle Fill Display shows the state of the Bottle Fill (ON or OFF). Service Test - 173 Ambient Light Display shows light sensor measurement (Hi or Lo). Night light will turn on when light sensor measures Lo. By changing the sensor's exposure to ambient light you can control the sensor measurement. Service Test - 175 Dispenser Line Display shows the state of the Dispenser Line (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can change state of Dispenser Line. Service Test - 182 LED Indicator Operation Press the Refrigerator Up Keypad to show operation of LED Indicators. All LED Indicators will flash. Press twice and LED will stop flashing. NOTE: This test is not operational at this time. Service Test - 183 Keypad Operation Display shows a numeric or letter display indicating the last key pressed. NOTE: Refrigerator Up/Down keypads have no effect when pressed and Freezer Up/Down keypads remain operational. 6 12827955 02/07

Service Specification Service Test - 192 Ice Maker State Test Display shows the status of the Ice Maker and the Heater (ON or OFF). When left Fresh Food door is open the Ice Maker cannot be energized, the test will display dr indicating an open Fresh Food door. When the Ice Maker heater is on, the test will display OnH. Service Test - 201 Mullion Heater Override Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Mullion Heater from cycling on with compressor (Off position) to 100% operation (On Position). Service Test - 202 Default Defrost Operation Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Defrost Operation from normal adaptive defrost (Off position) to minimum time between defrosts (On position). Service Test - 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual temperature (Off position) showing temperature set points only (On position). Service Test - 211 Fresh Food Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Fresh Food Temperature plus or minus in 1 F increments up to 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test - 212 Freezer Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Freezer Temperature plus or minus 1 F in increments up to 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test - 213 Ice Compartment Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Ice Compartment Temperature plus or minus 1 F in increments up to + 0 / + 8 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test - 221 Reset Default Settings Press the Refrigerator Up Keypad and Down Keypad to force to def (default factory settings). Service Test - 231 Water Filter Usage Display shows the percent water filter consumption. 100% indicates the filter should be replaced. Service Test - 232 Water Filter Days In Use Display shows the number of days since the filter was installed. Service Test - 241 Software Revision Main Control Board Display shows the Software revision of the Main Control Board). Service Test - 244 Software Revision Display Board Display shows the Software revision of the Display Board). 7 12827955 02/07

Wiring Diagram Service Specification Service Test 112 Freezer Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Freezer Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 113 Ice Compartment Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Ice compartment Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 121 Damper Operation Press the Refrigerator Up keypad and Down keypad to toggle Damper (OP) open and (CL) closed. NOTE: If damper is opening or closing it will not allow you to toggle damper and beep. Display will show state CL or OP if Damper is in the process of closing or opening. Service Test 131 Mullion Heater Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Mullion Heater Off and On. Service Test 141 Fresh Food Thermistor Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 144 Ambient Thermistor Will Show AmbientTemperature or, OP open thermistor or SH shorted thermistor. Service Test 145 Ice Box Thermistor Will Show Ice BoxTemperature or, OP open thermistor or SH shorted thermistor. Service Test 151 Fresh Food State Will show state of Fresh Food. OP (open) CL (closed). NOTE: By pushing either fresh food door switches you can toggle state from OP (open) to CL (closed). Service Test 152 Freezer Food State Will show state of Freezer. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle state from OP (open) to CL (closed). Service Test 153 Disable Internal Lights Press the Refrigerator Up keypad and Down keypad to toggle Enable (En) and Disable (dis) internal. 8 12827955 02/07 5 12827955 02/07