Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

Similar documents
CO 2 Incubators INCO 2

Humidity Chambers HCP

Constant climate chambers HPP Humidity chambers HCP

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Vacuum Ovens VO. From orange juice to electronic chips vacuum technology protects heat-sensitive materials


Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Waterbaths & Oilbaths

ICH260C. Climate Chamber. Product specification

ICP450. Compressor-cooled incubator. Product specification

ICH110. Climate Chamber. Product specification

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

ICH750L. Climate Chamber. Product specification

Constant climate chamber with humidity

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Constant climate chambers

Constant climate chambers

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I. CO2 INCUBATOR ICOmed. COMPRESSOR-COOLED INCUBATOR ICPeco/ICP

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

good reasons for a Memmert

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR ICOmed COMPRESSOR-COOLED INCUBATOR ICP

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

EC 160 CO 2. Incubator

Heating and drying ovens

Heating and drying ovens

Constant climate chambers

CO₂ incubators. C CB series

Plant growth chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Model C 170 CO 2 incubators with hot air sterilization

Environmental simulation chamber for complex alternating climate profiles

Drying and heating chambers

Model KBF 240 Constant climate chambers with large temperature / humidity range

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

incubator, the best in its class

CO₂ incubators. C CB series

KMF Environmental test chamber for constant climate

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO

Protect your research

ENVAIR lab CO2 Tri-Gas Incubator

Vacuum drying oven for non-flammable solvents

Model KBF 1020 Constant climate chambers with large temperature / humidity range

ADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY.

Model KBWF 240 Growth chambers with light and humidity

Model KBWF 720 Growth chambers with light and humidity

Heating and drying ovens

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Safety vacuum drying oven for flammable solvents

Vacuum drying VD VDL series

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Reproducible Climate...

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific Heraeus Heating and Drying Ovens

Platelet bags constant shaking for long periods of time.

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Heating and drying ovens

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

New Generation KBF 240 series

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Constant climate chambers

BINDER Scientific Product Catalog

www

BINDER Industrial. Product Catalog

Worldwide Leader in Technology

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Constant climate chambers

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

ENVAIR lab CO2 Incubator

Memmert. Product Range. Heating. Cooling. Humidity. and O 2 CO 2. Light. Vacuum QUALITY - RELIABILITY - PRECISION. HEATING AND DRYING OVENS INCUBATORS

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Refrigerators and freezers Pharmacy and laboratory 2016

Heating and drying ovens

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Refrigerators and freezers Research and laboratory 2018

NEW GENERATION. Efficient use of valuable space INCUBATORS

Chromatographic Air circulated Refrigerator, two-door TC 603

Introductions. Safe for cultivation

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

BINDER Product catalog

Steam sterilizer AHS-75-DRY


FITOCLIMA 600 & 1200 STABILITY

LABOKLAV. Autoclaves Made in Germany

VD 53 - Vacuum drying oven for non-flammable solvents

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

Transcription:

CO 2 Incubators INCO Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere Seven additional optional modules guarantee a top-class price-performance for every application Working chamber including all fittings as well as all sensors sterilisable at 160 C 100 % AtmoSAFE Choose your own top model for your application Contamination? Not with us! >>>> www.memmert.com

Stainless steel the noble material The inner chamber of the INCO consists exclusive ly of high-grade, fully recyclable hygienic stainless steel 1.4301 (ASTM 304). The additional electropolishing of the chamber, seamlessly welded by laser, ensures particularly smooth surfaces and therefore reduction in contamination risk (feature: Hygiene module). The outer casing is made mainly from sturdy textured stainless steel and is in accord with Memmert s holistic quality philosophy. Your own top model for your application With seven additional optional modules the INCO can be upgraded to your own top model: Comfort module: two gas connections with quick release connectors, automatic switch-over of gas cylinders (not in combination with O 2 module) Hygiene module: electropolished interior, seamlessly welded by laser Communication module: USB interface, Celsius standard software for programming and logging, ring log memory, printer interface CO 2 module: extended CO 2 range from 0 to 20 % Premium module: includes Comfort, Hygiene, Communication and CO 2 module (not in combination with O 2 module) Humidity module: active microprocessorcontrolled humidification and dehumidification (40 97 % rh) O 2 module: control of oxygen concentration by N 2 inlet; adjustment range 1 % up to 20 % O 2 (not in combination with Comfort and Premium module) Lean perfection, top precision! Standard model plus the module you need! The INCO provides for all kinds of applications a top-class price-performance. Every single equipment variation from standard to premium guarantees absolute precision and reliability. To include more comfort, optimum hygiene as well as perfect communication and documentation, users can now easily choose their own special top model, selecting from seven additional optional modules. 3 sizes: 108 153 246 litre chamber volume Standard equipment: CO 2 concentration up to 10 %, adjustable temperature from 20 to 50 C, 88 97 % rh with humidity limit control 2

Uniformity inside the chamber Chamber heating from all six sides, together with electronic humidity limit control, is mainly responsible for the optimal temperature and humidity distribution. An aluminium heatconducting jacket helps to ensure the homogeneity inside the chamber and in addition serves as heat store in case of a temporary supply outage. Despite the appreciably higher density of CO 2 compared with air, the turbulence-free chamber ventilation provides a uniformly homogeneous atmosphere. A Memmert special: the all-round heating is located below deep-drawn ribs which carry the non-tipping stainless steel shelves and at the same time ensure optimal and particularly gentle heat transfer to the incubator load. Germ-free through sterilisa tion, because disinfection is not sufficient! Hygiene is the be-all and end-all for highlysensitive applications with an organic chamber load. To prevent appliance-related (cross-) contamination, the chamber, including the ventilation system, the water trays and all the sensors can be sterilised in a 4-hour programme at 160 C (in accordance with DIN 12 880: 2007-05). To prevent unintentional start, the automatic sterilisation cycle (part of the standard equipment) can only be activated via the MEMMERT STERICard. Short recovery times due to active humidity control The INCO is equipped with a humidity limit control by which the maximum relative humidity created by water dishes in the chamber can be reduced from 97 % down to 88 %. The Humidity module, an active humidi fication system, can be incorporated optionally, with con trolled evaporation of water through a steam generator and sterile dry steam mixed into the air flow. This system offers an extended control range of 40 % to 97 % rh. Your advantage: more useful volume, optimum hygiene and short recovery time after opening the door. 100 10 minutes 38 minutes rh% 90 80 70 60 50 40 door open 30 sec. active humidity control humidity limit control rh(%) active rh(%) passive 30 20 t The difference in humidity recovery time between humidity limit control and active humidity control (example: INCO/108). 3

There s no such thing as a little bit reliable! CO 2 atmosphere, exact temperature control up to 50 ºC and condensation-free electronic humidity control up to 97 % rh create a controlled and physiologically perfect environment for cell and tissue cultures growing in vitro. Guarantee: Expression for best quality 3 years guarantee as standard on all INCO equipment variations. Optionally, this period can be extend ed to 4 years Accuracy: for regulated procedures Technical features for faultless processes: Internal ventilation for turbulence-free and uniform distribution of CO 2, O 2, humidity and temperature Multifunctional fuzzy-supported control for exact setting of tempera ture, humidity, CO 2 and O 2 content (with O 2 module only) Calibration facility for temperature, CO 2 and humidity on the actual controller Option: up to three additional and freely positionable Pt100 sensors Digitised NDIR CO 2 sensor with cyclic auto-zero function Capacitive humidity sensor Long-lived O 2 sensor (with O 2 module only) Barometric pressure compensation Documentation: for controlled quality The premium outfit for professional quality assurance (Communication module): Standard Celsius software with more functionality for pro gramm ing and documentation, also optional FDA- conforming software (no domain network support) Driver for communication with LabVIEW Internal ring memory for uninterrupted, long-term documentation fully protected against manipulation (approx. 3 months). USB interface (optional Ethernet) for programming and storage as well as printer interface Safety: of course! Still more functions with no error: Integral auto-diagnostic system with visual and audible error indication Multiple temperature monitoring Two high-grade Pt100 sensors Class A in 4-wire circuit, mutually monitoring Audible and visible signal on over- and under-temperature, CO 2 and humidity (with optional Humidity module), open door and empty gas cylinder Option: volt-free contacts on combination error and setpoint reached Option: personal User-ID-Card for protection against unauthorised operation Option: door with lock Option: HEPA-filter system acc. to EN 1822 Comfort: Just made for you! The INCO is easy to use: Clear, easy-to-clean underglass function display Memmert s unique feature: the push-turn control (patented) for intuitive selection from the entire menu Feet with height adjustment as standard Auto start-up programme Optional Comfort module: two gas connections with quick release connectors, automatic switch-over of gas cylinders (not in combination with O 2 module) Printer interface USB Ethernet LAN 4

Timer 1 Time indication (real-time) 2 Text messages (with optional O 2 module text and O 2 display) Temperature 11 Heating 12 Sterilisation operation 13 Setpoint/actual temperature Temperature adjustment: 20 50 C (control range from 8 C above ambient temperature up to 50 C) Variation (time): ±0.1 C max. Uniformity (spatial): ±0.3 C max. CO 2 atmosphere 24 Gas cylinder 1 (active) 25 Gas cylinder 2 (with optional Comfort module) 26 CO 2 setpoint/actual CO 2 -concentration selection 0 10 % adjustable in 0,1 % steps (optional CO 2 module: adjustable CO 2 concentration up to 20 %) Variation (time) ±0,1 % CO 2 max. Uniformity (spatial) ±0,3 % CO 2 max. 1 11 12 13 14 15 16 21 24 25 26 2 3 4 7 5 6 19 17 18 20 22 23 8 9 10 Operating mode 3 Normal operation (active) 4 Weekly timer* 5 Printer 6 Configuration 7 Data manipulation prevented through optional User-ID-Card 8 SET key 9 Push-turn control 10 Chip card reader for STERICard and optional User-ID-Card * Weekly timer programmable with one ON and OFF time per weekday; additional group function Monitor 14 Visual alarm 15 Alarm limit (heating switch-off temperature) 16 Sounder 17 Low alarm limit 18 Automatic alarm limit (ASF) 19 Temperature limiter 20 High alarm limit Humidity 21 Setpoint/actual humidity 22 Water level in storage tank 23 Steam generation Humidity selection 88 97 % rh with humidity limit control selected in 1 % steps (optional Humidity module: selectable rh concentration 40 97 % with active humidity control) Variation (time) ±1 % rh max. 5

Technical data, models and accessories for CO 2 Incubators INCO Interfaces: Optional with Communication or Premium module USB printer interface 75 D A 75 supply cable CO 2 In1 parallel interface USB interface 38 F C 202 38 Optional: (instead of USB): Ethernet LAN opening for test purposes 12 8 mm (minimum height) E CO 2 or N 2 In2 Pressure balancing pipe inner glass door B Dimensions of CO 2 Incubators (see table below) adjusting screw 76 6 Model sizes INCO 108 153 246 Stainless steel interior (deep-drawn) Volume approx. l 108 153 246 Width / Height / Depth (less 25 mm for air duct in the middle of the back wall) (A) / (B) / (C) mm 560 / 480 / 400 480 / 640 / 500 640 / 640 / 600 Provision for perforated shelves or grids half width / full width number _ / 4 _ / 6 2 x 6 / 6 Stainless steel Width (D) mm 710 630 790 exterior (rear zincplated Height (variable through adjustable feet) (E) mm 778 938 938 steel) Depth (without door handle, depth of handle 38 mm) (F) mm 550 650 750 Fully insulated, heated stainless steel door Extra internal glass door Ventilation Uniform atmosphere and temperature distribution through enclosed non-turbulent ventilation system, fully covered by the sterilisation process Temperature Electronic microprocessor temperature controller with Pt100 and auto-diagnostic system Temperature sensors Pt100 Class A in 4-wire circuit for uninterrupted operation on failure of one Pt100 with warning indication double double double Temperature range (during sterilisation the temperature is fi xed at 160 C set value) C from 20 1) up to 50 from 20 1) up to 50 from 20 1) up to 50 Temperature fl uctuations with time (to DIN 12 880: 2007-05) C ± 0,1 ± 0,1 ± 0,1 Temperature variation in chamber at 37 C (to DIN 12 880: 2007-05) C ± 0,3 ± 0,3 ± 0,3 Sterilisation STERICard for automatic chamber sterilisation cycle 4 h at 160 C (not for sterilising the load!) CO 2 Digital electronic CO 2 control with autozero, NDIR system with auto-diagnostic system, acoustic fault indication, barometric pressure compensation Setting accuracy CO 2 0,1 % 0,1 % 0,1 % Adjustment range CO 2 0 up to 10 % 0 up to 10 % 0 up to 10 % Humidity Capacitive humidity sensor (sterilisable) Monitor Timer functions Setup Standard water dishes number 1 1 2 Adjustable humidity limit control (88 97 %) incl. digital indication and auto-diagnostic system with visual and acoustic fault indication (air supply via sterile fi lter) ensures rapid reaching of set humidity and short recovery times while avoiding condensate formation Microprocessor temperature monitor acting as overtemperature protection, with Pt100 incorporating fault diagnostics with visual and audible alarm Digital over- and undertemperature monitor Temperature monitoring band automatically linked to the setpoint (ASF) Relay for reliable heating cut-off in case of fault Mechanical temperature limiter (TB) Audible alarm: Over- and under-temperature, over-co 2 and empty gas cylinder, open door, underhumidity and empty water tank Real-time/weekly programmer with group function (e.g. Monday-Friday) Calibration (no separate PC required): Temperature: 3-point calibration on controller. CO 2 : 3-point calibration at 5 %, 7 % and 10 %, Auto-zero-function of NDIR CO 2 -sensor after every sterilisation and cyclically every 24 h. Humidity: 2-point calibration at 20 % and 90 % Setting of language for dialogue and display D / UK / E / F / I Further data Electrical supply 2) V / Hz 230 / 50/60 230 / 50/60 230 / 50/60 Electrical load at a voltage of 230 V 2) (±10 %), 50/60 Hz approx. W 1000 1500 2000 Net weight / Gross weight approx. kg 70 / 78 80 / 96 110 / 125 Subject to technical modifi cations All performance data are typical average values for standard appliances. 1) Operating range from 8 C above ambient 2) Other voltages on request

Model sizes INCO 108 153 246 Standard Perforated stainless steel shelves (full width) number 2 3 3 accessories Stainless steel water dishes, 40 mm high number 1 (full width) 1 (full width) 2 (half width) Works calibration certifi cate (test point chamber centre at 37 C) Standard version Incubator INCO INC 108 INC 153 INC 246 Modules Comfort module: 2) two gas connections with quick release connectors, automatic switch-over of gas cylinders T1 T1 T1 Hygiene module: electropolished interior, seamlessly welded by laser T2 T2 T2 Communication module: USB interface, Celsius 1) standard software for the control and logging of temperature, CO 2, O 2 (with O 2 module) and relative humidity; internal log memory 1024 kb as ring memory for all setpoint values, actual values, errors, settings with real time and date: logging T3 T3 T3 approx. 3 months at 1 min. logging interval; parallel printer interface for all PCL3-compatible printers CO 2 module: extended CO 2 range from 0 to 20 % T4 T4 T4 Premium module: 2) includes Comfort, Hygiene, Communication and CO 2 module T5 T5 T5 Humidity module: active microprocessor control for humidifying and dehumidifying (40 97 % rh), incl. digital indication and auto-diagnostic system; humidity supply with distilled water (from an external tank), dehumidifying via sterile fi lter; K7 K7 K7 (standard humidity limit control and water dishes are omitted). O 2 module: 2) Control of oxygen concentration by N 2 inlet, adjustment range 1 % bis 20 % O 2, setting accuracy 0,1 % T6 T6 T6 Options Entry port at the back, heated, can be closed by a silicone stopper, inner diameter 57 mm F9 F9 F9 Additional Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documentedvia the Celsius 1) software or on an attached printer H8(x) H8(x) H8(x) HEPA-fi lter for chamber according to EN 1822, packed in sterile condition, incl. fi xing unit H9 H9 H9 4-part partitioning of interior with 4-part gas baffl e K4 (replacement of 3 full-width shelves by 6 half-width shelves) Door with lock (safety-lock) B6 B6 B6 Door hinged on the left B8 B8 B8 Additional perforated stainless steel shelf, half width E6(x) Additional perforated stainless steel shelf, full width E7(x) E7(x) E7(x) Additional stainless steel grid, full width E3(x) E3(x) E3(x) Additional water dish E2(x) (full width) E2(x) (full width) E2(x) (half width) Stacking version for 2 units of equal size (bottom unit modifi cation) G3 G3 G3 Subframe (622 mm high) 3) G5 G5 G5 Subframe (130 mm high for 2 stacked incubators) 3) G7 G7 G7 STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) V9 V9 V9 Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties V1 V1 V1 Computer interface RS485 (for networking a maximum of 16 ovens) instead of USB 4) V2 V2 V2 Interface RS232 instead of USB 4) W6 W6 W6 Interface Ethernet instead of USB incl. software Celsius Ethernet-Edition 4) W4 W4 W4 Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units 4) W1 W1 W1 Documentation package consisting of parallel USB converter cable including PCL3- compatible HP colour inkjet printer with USB interface (HP Offi cejet 6000 or successor) W2 W2 W2 for direct connection of printer to Memmert unit 4) USB connection cable for computer interface 4) W7 W7 W7 Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (setpoint of temperature and CO 2 is reached) H5 H5 H5 Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for combination error message of temperature and CO 2 controller (e. g. supply failure, sensor fault or fuse) H6 H6 H6 Pressure reducing valve to DIN 8546, incl. gas cylinder monitor H7 H7 H7 Works calibration certifi cate for 5 %, 7 % and 10 % CO 2 (measured at 37 C) Z5 Z5 Z5 IQ check list with works test data for incubator as support for validation by customer Q1 Q1 Q1 OQ check list with works data for one freely selectable CO 2, humidity and temperature value 5) incl. temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 with Q2 Q2 Q2 works test data as support for validation by customer Software Celsius FDA Edition 4) + 6) for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down Q3 Q3 Q3 in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA) Integration of additional units (up to max. 16 units) into an already existent FDA-software licence 4) + 6) Q4 Q4 Q4 Start-up of INCO incubators and brief training 7) (D, A, CH only) through MEMMERT service. Requirement: incubator is at its fi nal location and all services have been provided by the purchaser. K9 K9 K9 (Applies only in connection with orders and payments for new units) Guarantee extension by 1 year Q5 Q5 Q5 Subject to technical modifi cations All performance data are typical average values for standard appliances. Standard model, basic specifi cation Not available (x) Please specify quantity required after the order number 1) MEMMERT Celsius software has been tested for Windows 7, Vista and XP 2) Combination O 2 module with Comfort and Premium module impossible 3) Screws for adjusting height are taken out of the feet and mounted into the subframe 4) Only in combination with Commmunication or Premium module 5) Additional temperature values optionally 6) Requires Windows 2000 Professional or XP Professional 7) Service not subject to any discount 7

Universal ovens Incubators Hot air sterilisers Ovens Vacuum ovens Peltier-cooled incubators Compressor-cooled incubators Storage chambers Cooled incubators Memmert GmbH + Co. KG P.O. Box 1720 D-91107 Schwabach Germany Tel. +49 (0) 9122 / 925-0 Fax +49 (0) 9122 / 145 85 E-Mail: sales@memmert.com www.memmert.com www.facebook.com/memmert.family CO 2 incubators Humidity chambers Constant climate chambers Climate chambers Climatic test chambers Temperature test chambers Environmental test chambers Water and oil baths Your Memmert Partner The platform for experts: www.atmosafe.net Upon your request we are pleased to send you detailed brochures. Some of the illustrations in this publication include special accessories. We reserve the right of technical modifications. Dimensions are subject to confirmation. MS-Windows is a registered trade-mark of the Microsoft Corporation. LabVIEW is a registered trade-mark of National Instruments. Order No. D10901 Printed in Germany CO 2 1111 e 3.0 by Memmert GmbH + Co. KG www.ad-room.de