Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI)

Similar documents
Materials to Restrict Access and Cover the Floor/Ground Signs

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

Experiment #6 Photolithography: Microprocessing Technology Fabrication of the microstructures with SPR photoresist

UNSIGNED HARDCOPY NOT CONTROLLED

STANDARD LEVEL 1 PROCEDURE

PDS 2010 Parylene Coater SOP

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

Wet Bench Standard Operating Procedures

Cleaning of fiber optic connectors

Standard Operating Manual. PEL Wet Station X Clean Organic Solvent Station

Chargebuster Ion Gun Installation, Operation and Maintenance

Operation Procedure for SMiF Wet Hoods (Solvent, Spin Coat, Acid, and Develop Hoods)

UV Lamp and Quartz Sleeve Replacement/Maintenance

Chargebuster Ion Gun Installation, Operation and Maintenance

AIR PURIFIER WITH GERMICIDAL UV LIGHT

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

Critical Environment Ionizing Blower. Model 5810i. User s Manual

Arizona State University NanoFab PARYLENE COATER. Rev D

UV100E Ultraviolet Air Treatment System

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

Cleaning Up After Rodents

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

The safety refresher are mandatory for ALL users Cleanroom access and instrument usage will be denied for users who:

ONSITE WASTEWATER EFFLUENT UV DISINFECTION DEVICE MODEL 120 UV UNIT PART #P8888

Personal Protective Equipment. Shawn Appling Associate Extension Agent, Culpeper County Office Serving Culpeper, Madison, and Orange

HAZARDOUS SAFETY SYMBOLS

Air Cleaning System USE & CARE INSTRUCTIONS. Refurbished

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Fiber Optic Connector Cleaning and Inspection Kit Instructions

Teaching Lab Headway Spinner SOP

MIMAKI ENGINEERING CO., LTD.

1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

CPAP Washbasin Manual

Maintain and restore hard floors

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

Clean! Clean working by Qdel. Qdel laminating supplies Hamburgstraat 9 NL-7575 EG Oldenzaal T: E: I :

Cleaning Kit Instructions - DTC550 Printer

Photolithography SOPs

SUBFAB DOC PDOC 0152 ROGER SHILE 7/11/97. SCIENCE MISSION SQUID CARRIER SUBSTRATE (Part# ) FABRICATION 1. Document Revision Record

Standard Operating Procedure: Spinner

Chargebuster Ion Gun Installation, Operation and Maintenance

OPERATION AND MAINTENANCE MANUAL

Microdiesel Cleaning & Assembly Products

installation Guide

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

PRODUCT SPECIFICATION

R I T Title: Manual Processing Bench #2 Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 08/05/2008

Decon Scrubber Owner s Manual

Item # Modular Blast CaBinEt instructions

Operating / User Manual

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

PDMS Casting Station Supplies

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

PRODUCT SPECIFICATION

Hantavirus Procedures

UVIOOAUltravioletSystem

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN VETERINARY EQUINE PRACTICE

Insulators and Conductors

Care and maintenance instructions for products supplied by VEKSØ A/S

PRODUCT SPECIFICATION

2. PROCEDURE DESCRIPTION AND PROCESS FLOW

USER S GUIDE FOR. 12 Months Residual Protection. Eco-Friendly. Non-Toxic. When Properly Applied

Connection Instructions: Welch 2042 Vacuum Pump To TVO-2 Vacuum Oven

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Cleaning Procedures in ICP-MS Laboratories

HYGIENE AND SANITATION

Annual Tune-Up Procedure

Safety Information Contents List Odorox Boss XL3 Unit Operational Guidelines Operating The Odorox Boss XL3... 4

PERFORM Operating Document

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Packed With Features. Smart Pulsar controls are conveniently

AirInstinct Air Purifier

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

SELF-CONTAINED CRESCENT CUBER

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Packed With Features ACCESSIBLE. Filter cartridge is automatically cleaned each time the pedal is operated.

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

Technical Bulletin IG018 Quanex Building Products

Revised: January 8, Goal: Deposit, expose, and develop standard positive photoresist films as an etch mask, liftoff mask, or sacrificial layer.

The Mirage Touch kit. The Mirage warranty. Residential maintenance guide

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

The True Value of Connector Inspection: New Challenges and Best Practices

TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier

VACUUM CHAMBER PM TECHNIQUE LAM 2300 EXELAN FLEX OXIDE ETCH GRAPHITE ELECTRODE

Oil Mist Eliminator for VSPR Series Leak Detectors

Instruction Sheet DANGER

5Make electrical connections.

Best practices in Cleaning and Safety

Instruction Sheet DANGER

Operating Instructions

ZERO Economy Blast Cabinets

ADORABLE Air Purifiers

Ultrasonic and Megasonic Cleaners

eware Handling & Cleaning Procedures

Cleaning & Sterilization

R I T Title: RCA Bench #2

Transcription:

Rev ECO Description Author Approved Date A 37-428 Initial Release M Gabutti RFGoeke 10/19/2016 D Riley Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI) Precision Cleaning Procedure Dwg. No. 99-02012 Revision A June 13, 2016 99-02012 Page 1 of 5 Revision A

Table of Contents 1.0 PREFACE 3 2.0 SCOPE 4 3.0 ACRONYMS 4 4.0 SAFETY 4 5.0 CLEANING PROCEDURE 4 5.1 MATERIALS REQUIRED 4 5.2 CLEANING PROCEDURE 4 6.0 ALTERNATE CLEANING PROCEDURE 5 6.1 MATERIALS REQUIRED 5 6.2 ALTERNATE CLEANING PROCEDURE 5 99-02012 Page 2 of 5 Revision A

1.0 Preface Revision A is the Initial Release of 99-02012 99-02012 Page 3 of 5 Revision A

2.0 Scope This document describes the process for cleaning a wide variety of materials and components. It may be used for cleaning stainless steel; aluminum with anodized, chromated, or hard coated surfaces; Teflon, nylon, and various types of plastic materials, metals and hard coated surfaces 3.0 Acronyms UC: Ultrasonic cleaner ESD: Electrostatic discharge DI: Deionized water IPA: Isopropyl Alcohol 4.0 Safety Latex rubber gloves shall be worn at all times while performing this procedure. Safety glasses must be worn while working with solvents. Safety UV polycarbonate glasses must be worn when working with UV light sources. Never look directly into a UV light source. Questions should be directed to the responsible engineer. 5.0 Cleaning Procedure 5.1 Materials Required Ultrasonic cleaner Electrowave SUH- 110 or similar Ultrasonic cleaner Electrowave EW- 22EXP with explosion proof cover Small Tenney Jr oven or similar Surface Cleanse 930 detergent Deionized water Texwipes Isopropyl alcohol UV Light UVP- 100 or similar UV protection goggles HEPA vacuum ESD safe swabs Cleanroom ESD ZipTop bags Latex gloves 5.2 Cleaning Procedure 1. Put Items being cleaned in UC wire basket. 2. Fill UC with tap water just enough to cover the parts being cleaned. 3. Add surface cleanse 930 cleaning solution in a 100:1 ratio water/cleaning solution 4. Turn UC on. 5. Let items sit in wire basket for 3-5 minutes Do NOT exceed 5 mins. 6. Removed wire basket with items and rinse again in a stainless steel basin with D.I water 7. Place parts on clean Texwipes and blow dry with filtered lab grade N2 8. Place parts in UC. 9. Fill UC with IPA enough to cover parts. 99-02012 Page 4 of 5 Revision A

10. Turn UC on and wait 1.5 minutes (do NOT exceed this limit) 11. Turn UC off 12. Drain UC 13. Rinse part with clean IPA while still inside the UC 14. Drain UC 15. Place parts on Texwipes 16. Blow dry with filtered lab grade N2 17. Place parts in Tenney oven and bake at 75C for 30 mins 18. Let parts cool off. 19. Inspect parts with UV light (wear UV eye protection goggles) 20. If particulates are found use HEPA vacuum to vacuum particles 21. If no particulates are found double bag with ZipTop ESD bags and store parts in bonded stock room. 6.0 Alternate Cleaning Procedure For large items that can t fit in the Ultrasonic Cleaner. 6.1 Materials Required Isopropyl Alcohol, 99.5% IPA TEXWipes UV Light source UVP Model B100Y or equivalent Polycarbonate UV safety glasses HEPA Vacuum Cleanroom gowning attire Latex gloves 6.2 Alternate Cleaning Procedure 1. Perform a gross cleaning of the item using IPA wipes prior to entering the cleanroom gowning area. a. Perform a general cleaning on all exposed surfaces. b. Ensure the item has no particulate or fiber debris. 2. Transfer the item into the gowning area. 3. Gown into clean room attire. 4. Repeat the item cleaning using IPA wipes in the gowning area a. Wipe items in one direction only. b. Replace wipes as needed to ensure cleanliness is achieved. 5. Turn on UV light. Wait approximately 5 minutes until bulb is fully warmed. a. Put on UV safety goggles b. Caution: UV lens is extremely hot, avoid contact. 6. Turn lights off in gowning area. 7. Perform UV light inspection, particulates will appear white under UV light illumination. 8. If item is clean and free of particulates you can proceed to transfer item into cleanroom. 9. If item needs further cleaning continue to next step 10. Turn on HEPA Vacuum. Use UV light and vacuum off the item while looking for particulates. Remove as many particles as possible. Turn off vacuum and UV light when finished 11. Turn lights on in gowning area. 12. Transfer the item into the cleanroom. 99-02012 Page 5 of 5 Revision A