Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

Similar documents
ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

Laser Particle Size Analyzer

PSA Series. Particle Size Analyzer

An FT-NIR Primer. NR800-A-006

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Open-area Smoke Imaging Detection (OSID)

BACK SCATTER ELECTRON (BSE) Rev. 0313

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

ISO INTERNATIONAL STANDARD

Open-area Smoke Imaging Detection (OSID)

Infrared Moisture Balance (FD-800)

Open-area Smoke Imaging Detection (OSID)

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

ISO/TS TECHNICAL SPECIFICATION

Class 1 laser beam sensor safe for your eyes

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

Class 1 laser beam sensor safe for your eyes

Installation Instructions for the

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Class 1 laser beam sensor safe for your eyes

File No. 28(1192)/2017/Pur Date: 19/06/2018

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

Standard Operating Procedure Raman Microscope - Renishaw invia

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Advanced Level Seminar 2015

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

Compact Raman spectrometer system for low frequency spectroscopy

Laser Collimated Beam Sensor

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

CHARACTERIZATION OF SMOKE MACHINES IN TESTING AIRCRAFT SMOKE DETECTORS TINA EMAMI. A thesis submitted to the. Graduate School New Brunswick

PULSE OXIMETER PACKAGE

Sustainability in commercial laundering processes. Management Systems

Smoke Detector Testing

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

Open-area Smoke Imaging Detector. Engineering Specification

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Product data sheet Palas Fidas 200 S

Features and Benefits

Model S FT-IR SPECTROMETER

Features and Benefits

C-NRPP Quality Assurance Guidance for Radon Test Devices

Customized MCPs for Analytical Instruments. An MCP for every application

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Instruction Manual. Self-Leveling Laser Level Model No

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

CALIBRATION HOW IT WORKS

Certificate: / 9 February 2011

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

English. Instruction and operation manual S 530. Leak detector for pneumatic systems

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

CERTIFICATE of Product Conformity (QAL1 )

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

AV6419 BOTDR. Product Overview. Main Features

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

AV6416 OTDR. Product Overview: Main Features:

IQ/OQ Protocol Installation Qualification/ Operation Qualification

CALIBRATION HOW IT WORKS

M700-Series Multifunction OTDR

CEIA THS/PH21. series. High Performance Pharmaceutical Metal Detection Systems. Superior and Consistent Detection

Remote Gamma Imaging of High Dose Environments

CALIBRATION HOW IT WORKS

Laser Use Registration & Application (L.U.R.)

Optical Techniques for Industrial Inspection

International comparison of validation methods for dust concentration measurement

Air Resource Specialists, Inc.

QUICK BGA2015. Precision BGA Rework System. Features:

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

CHAPTER Committee Substitute for Committee Substitute for Committee Substitute for House Bill No. 973

Grove - Laser PM2.5 Sensor (HM3301)

Davis Soil Moisture and Temperature Station Protocol

INTERNATIONAL STANDARD

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Technical Information OUSBT66

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Temperature Data Logging

M700-Series OTDRs. or (800) , (603)

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

The reprint reproduction or disclosure of this material to the third party is prohibited. PARTICULATE MATTER SENSOR. Introduction of

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Software Version 2.01 LEVEL MONITOR MODEL 220

Laser Diagnostics and Optical Measurement Techniques

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Laser Use Authorization

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Shanghai Xixun-----professional supplier of Led sign control system website: un.com Step2, plug u-disk into computer, open LED editor and choose upgra

Sensor Report. University of Florida Department of Electrical and Computer Engineering EEL5666 Intelligent Machines Design Laboratory

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Transcription:

DRY & WET DISPERSION PARTICLE SIZE ANALYZER Instruction Manual Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

Table of Content CHAPTER CONTENT PAGE No. 1 Introduction 1 2 Specifications 2 3 Report Items 3 4 Features 3 5 Software Function 4 6 Service Report 5

CHAPTER 1. INTRODUCTION : This model is used for both wet and dry dispersion method of particle size measurement and analysis. Application: Measure the particle size distribution of samples that can't be dispersed in liquid but in air, and also can measure the samples that can be dispersed in liquid. Principle: Uses the principle of laser light scattering to determine particle size distribution. Patents adopted: Integrated Laser Emitter, Scattered light detection around a sphere surface (DAS). One standard LPSA-40A includes:- 1) Measuring unit. 2) Sample feeders (dry sample feeder and an attachment for wet sample feeder). 3) Air Compressor. 4) Air Tank. 5) Oil-water filter. 6) Air drier. 7) Vacuum cleaner. 8) Special software. 9) Lab tools and other accessories. The large angle detectors are placed in a spherical surface to get accurate focus of the large angle scattered light. 10 9 8 1. Laser 2. Beam extender 3. Pinhole 4. Device for center alignment 5. Fourier lens 6. Reflection prism 7. Measurement window 8. Central detector 9. Array of ring-shaped detectors 10. Array of large angle detectors 1 2 3 4 5 6 7-1 -

Scattered light detection around a sphere surface ( DAS ) Air compressor Air container Filter Dust Collector Air Dryer LPSA-40A Laser Particle Sizer Dust collector of vortex Printer Computer Dust Catcher Sample circulating system THE STRUCTURE OF LPSA-40A DRY & WET DISPERSION LASER PARTICLE SIZE ANALYZER 2. SPECIFICATIONS:- 1. Measuring Range : 0.1-800μm 2. Sample Feeding : dry and wet dispersion 3. Repeatability : <3% 4. Measurement Duration : 1-2minutes 5. Number of Detectors : 54 6. Light Source : He-Ne laser, 2.0 mw, 0.6328 μm 7. Environmental Requirement : Temperature : o 5-35 C Humidity : <85% 8. Power Consumption : Measuring unit : 30W Circulation sample feeder : 150W Air Compressor : 1500W Bucket type vacuum cleaner : 1200W 9. Dimension : - 2 -

Measuring Unit : 1000 350 250mm (L W H) Circulation Sample Feeder : 370 200 300mm 10. Sampling Continuous Time : 1-100seconds 11. Date output, save and transmission : Video display Printer copy Computer hard disk save Long-distance transmission 12. Printer : Any printer that is compatible with the computer. Pressure controlling-valve Air filter cleaner Air Compressor Gas Container Dry Powder Feeder Beam extender Signal magnifier A/D conversion A/D Laser Pinhole Collimation lens Fourier lens Array of Detector Computer Vaccum Cleaner 3. REPORT ITEMS:- Particle size distribution table & graph, median diameter, characteristic diameter, coefficient of breadth, SSA, subsection size percentage, percentage of particles over >80μm (fineness), other indices. 4. FEATURES:- 1. Two patents adopted to enable a high accuracy of measurement. 2. Without changing the lens, through the measurement provides great convenience in operation. 3. Auto alignment of detectors, shock-proof pinhole. 4. Two sample feeding systems, the dry sample feeder being integrated with the main measuring unit and the wet sample circulating feeder standing alone with built-in ultrasonic probe, realize a conveniently optional shift between dry & wet dispersions. 5. A manual pre-setting on the scope of beam obscuration eliminates the size distributions of samples whose obscurations are not within the scope and hence enables a higher accuracy of measurement. 6. The application of large angle scattered light detectors, in addition to the dominating and assistant detectors, extends the lowest measurement range down to 0.1μm. - 3 -

5. SOFTWARE FUNCTION:- 1. Two distribution models : Rosin-Ramler, multi wave crest. 2. Two report models : General purpose, statistics. 3. Two accumulative directions : small to large, large to small. 5. Data input function. 6. Reports can be exported as Excel format or other text format files. 7. Multiple reports can be opened at the same time to enable comparisons among reports. 8. Report items can be set according to customer's requirements. 9. Adjustment and control on every single step of measurement. 10. Adjustment and control on the sample feeders. 11. Password function. - 4 -

SERVICE REPORT Customer s Address : Contact Person / Designation : Tel.No.: Fax No.: Weekly Off.: Dept.: Date From Time To System Configuration Model Serial No. Date : Status : OK SR. No. Not OK Installation Warranty Demonstration Maintenance Repairs Contract Application Calibration Billable Validation Courtesy Nature of Problem : Observation & Action Taken : Customer s Remarks : Parts Replaced : Parts Recommended / Action Required : Yes Service Engineer s Name & Signature No Requisition Number : Customer s Name, Signature, Date & Stamp Page Of -- 13 5 --