Development and Application of Micro Channel Heat Exchanger for Heat Pump

Similar documents
Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Purdue e-pubs. Purdue University

Investigation of Port Level Refrigerant Flow Mal-distribution in Microchannel Heat Exchanger

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Global Journal of Engineering Science and Research Management

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

REVIEW PAPER ON REFRIGERATION SYSTEM USING MICROCHANNEL CONDENSER

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Application of a hybrid control of expansion valves to a 3-ton large room cooling system

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Advanced round-tube, plate-fin (RTPF) heat-exchanger coils contribute to the high efficiency of heat pumps

Study of R161 Refrigerant for Residential Airconditioning

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Comparison of Oil Retention in R134a and CO 2 Climate Control Systems

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Slide 2 The type of coils we will be talking about today are round copper tube, flat fin coils.

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

Keywords: Micro channel condenser, refrigeration system, heat transfer rate, refrigerant Effect.

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

2.2. General view of Microchannel Heat Exchangers

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Design and Realization for the Environmental Protection Type of Pig-Farm Model Based on the Sensor Technology

2. HEAT EXCHANGERS MESA

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Efficient adsorption refrigerators integrated with heat pipes

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Development of Small-diameter Tube Heat Exchanger: Circuit Design and Performance Simulation

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

R32 Compressor for Air conditioning and Refrigeration applications in China

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

DESIGN, DEVELOPMENT AND TESTING THE

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental study on combined defrosting performance of heat pump air conditioning system for pure electric vehicle in low temperature

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology


Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

Study and Investigation of Refrigeration System Using Microchannel Condensers and round tube condenser-review

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

13 SEER CONDENSING UNITS & AIR HANDLERS

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Design of Humidity Monitoring System Based on Virtual Instrument

Performance investigation of Air-conditioning system using ejector as expansion device

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

Evaluation the Effect of Washing on the Heat Transfer Capacity and Air-Side Flow Resistance of Air Cooled Condensers

Review of Temperature and Humidity Control Technology for Air Conditioning and Heat Pump Systems Paper 2386

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

EFFICIENT ADSORPTION REFRIGERATORS INTEGRATED WITH HEAT PIPES

A study of Transient Performance of A Cascade Heat Pump System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Application of a Hybrid Control of Expansion Valves to a 5-ton Domestic Heat Pump

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Submittal Data Sheet

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

Heat pump supplemental heating system for motor vehicles

Low GWP Refrigerants for Air Conditioning Applications

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

70% Save time and money with MCHE standard products. MicroChannel Heat Exchangers. Lower refrigerant charge

Induction heating with the ring effect for injection molding plates

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Transcription:

Development and Application of Micro Channel Heat Exchanger for Heat Pump Jing ZHOU a, Zhiheng YAN a, Qiang GAO a, * a Sanhua (Hangzhou) Micro Channel Heat Exchanger Co.,Ltd, #289, 12 th Street, Hangzhou Economic Development Area, Zhejiang, 310018, Abstract China In the paper, micro channel heat exchangers are applied to residential and commercial heat pump airconditioning systems. The performance of heat pump system using micro channel heat exchangers is compared with that of baseline heat pump system using tube & fin heat exchangers. Experimental results show that the capacity of heat pump system can increase by 4% at most by using micro channel heat exchangers, and energy efficiency can increase by 4% at most. The weight of heat exchangers can be reduced by 45% at most, and the refrigerant charge can be reduced by 51% at most. In addition, the distribution of refrigerant becomes more uniform by distribution optimization. Keywords: Micro channel heat exchanger; air-conditioning; heat pump; SEER; HSPF; refrigerant charge; defrosting; frosting; 1. Introduction With the improvement of the air-conditioning energy efficiency, as well as cost increase, the air conditioner manufacturers are looking for the solutions of efficiency improving and cost saving. Micro channel heat exchanger (MCHE), gets the attention from air-conditioning refrigeration industry because it has many advantages such as the high heat transfer efficiency, less refrigerant charge, compact structure and light weight. So MCHE is applied to the air conditioner system gradually. But till now, the MCHE has not been used for mass productive heat pump system widely because the refrigerant maldistribution and defrosting issue are not easy to deal with. In Satish G. Kandlikar s (2007) study, he provided a roadmap for their implementation, with a critical review of the status of his understanding in this field, recommendations for obtaining fundamental performance data and correlations, and an emphasis on innovative designs of minichannel heat exchangers. According to the study of Zhaogang Qi etc. (2009), the new mini-channel evaporator had advantages on volume (17.2% smaller), weight (2.8% lighter) and heat transfer (4.3% higher), but a little penalty on air and refrigerant side pressure drop. In the paper of Liang-Liang Shao etc. (2010), the refrigerant-side maldistribution was found remarkable impact on the microchannel heat pump system performance under the frost conditions. And they figured out the best trade-off in the design of frost tolerant evaporators. Jianghong Wu etc. (2011) studied the frosting process of a folded louvered-fin. The non-uniform surface temperature distribution caused by the unequal distribution of the refrigerant flux in the flat tubes micro channels resulted in uneven distribution of frost. Ehsan Moallem etc. (2012) found out that at a given air dry bulb temperature, the fin surface temperature and air humidity were the primary parameters that influence the frost growth rates. Water retention and air velocity had a secondary impact on the frosting performance. There were some studies about applying the MCHE to heat pump system. In the * Corresponding author. Tel.: +86-571-86672503; fax: +86-571-86672332. E-mail address: qianggao@sanhuamc.com.

study of Bo Xu etc. (2013), ice blockage formed in the fin root gaps of the horizontal-tube sample was because of water retention. The vertical-tube sample exhibited no obvious water retention on the surface. In this study, the MCHEs are applied to residential and commercial heat pump systems. The performance, weight and refrigerant charge of the heat pump system using MCHEs are compared with that using copper tube & fin heat exchangers (TFHEs). And the refrigerant maldistribution and defrosting issue are solved. 2. Micro channel heat exchanger for the residential heat pump system 2.1. Micro channel heat exchanger design The MCHEs are applied to a residential heat pump system, which is a common residential 3Ton unitary split unit in North America. The refrigerant is R410a. The indoor and outdoor units are shown in Fig. 1. And Fig. 2 shows the pictures of indoor and outdoor heat exchangers. The indoor TFHE is A shape, and has 3 rows φ9.52 mm copper tubes, which is replaced by a 1 row 25.4 mm width MCHE. And the outdoor TFHE is C shape, and has 1 row φ9.52 mm copper tubes, which is replaced by a 16 mm width MCHE. Both of the indoor and outdoor MCHEs have horizontal headers, vertical micro channel tubes and louver fins. The details of TFHEs and MCHEs could be found in Table 1. The heat pump system with TFHEs is named case 1, and the heat pump system with MCHEs is case 2. The experiments are performed on the psychrometric calorimeter test bench of Sanhua company. The test conditions are shown in Table 2. This paper compares the performance of the heat pump system with TFHEs (case 1) and the heat pump system with MCHEs (case 2). As shown in Fig. 3, when compared with case 1, the cooling capacity and SEER of case 2 increase by 4% and 2% separately. Meanwhile, case 2 has equal heating capacity with baseline case 1, and HSPF can increase by 1%. Fig. 3 also shows that the weight of heat exchangers in case 2 is only 56% of case 1. And the refrigerant charge of case 2 is only 49% of case 1. Two phase refrigerant mal-distribution is one of the main problem for MCHE when it is used as evaporator. The outdoor MCHE is taken as an example to show the distribution optimization. The thermal images of outdoor MCHE before and after refrigerant distribution optimization could be seen in Fig. 4. Defrosting is another problem for the outdoor MCHE when it runs as evaporator. Residual frost is not accepted, and the drainage water needs flow down quickly during the defrosting process. According to the tests, there is no frost remain and no drainage problem during the defrosting process for the outdoor MCHE. Fig. 1. Pictures of the indoor unit and outdoor unit for the 3Ton unitary split heat pump system. 2

Fig. 2. Pictures of the indoor and outdoor heat exchangers. Table 1. Information of tube & fin heat exchangers (TFHEs) and microchannel heat exchangers (MCHEs) for the 3Ton unitary split heat pump system. Case Indoor/Outdoor Coil Type Size Tube Parameter Fin Height FPI (mm mm) (mm) (mm) Row 1 Indoor Coil TFHE 420 610 φ9.52 / 14 3 Outdoor Coil TFHE 2320 1020 φ9.52 / 16 1 2 Indoor Coil MCHE 420 610 25.4*1.3 8.1 16 1 Outdoor Coil MCHE 2170 880 16*1.3 8.1 14 1 Table 2 Test conditions Indoor Dry-Bulb ( ) Indoor Wet-Bulb ( ) Outdoor Dry-Bulb ( ) Outdoor Wet-Bulb ( ) ARI-A 80 67 95 75 ARI-B 80 67 82 65 ARI-C 80 57 82 ARI-D 80 57 82 ARI-H1 70 60 47 43 ARI-H2 70 60 35 33 ARI-H3 70 60 17 15 2.2. Experiment results and analysis This paper compares the performance of the heat pump system with TFHEs (case 1) and the heat pump system with MCHEs (case 2). As shown in Fig. 3, when compared with case 1, the cooling capacity and SEER of case 2 increases by 4% and 2% separately. Meanwhile, case 2 has equal heating capacity with baseline case 1, and HSPF can increase by 1%. Fig. 3 also shows that the weight of heat exchangers in case 2 is only 56% of case 1. And the refrigerant charge of case 2 is only 49% of case 1. Two phase refrigerant mal-distribution is one of the main problem for MCHE when it is used as evaporator. The outdoor MCHE is taken as an example to show the distribution optimization. The thermal images of outdoor MCHE before and after refrigerant distribution optimization could be seen in Fig. 4. Fig. 5 shows that the heating capacity of heat pump system increases by 5% after distribution optimization of outdoor MCHE. Also, the HSPF has 4% increase according to the optimization. Defrosting is another problem for the outdoor MCHE when it runs as evaporator. Residual frost is not accepted, and the drainage water needs flow down quickly during the defrosting process. According to the tests, there is no frost remain and no drainage problem during the defrosting process for the outdoor MCHE. 3

Fig. 3. Comparison of 3 Ton unitary split heat pump systems using TFHEs (Case 1) and MCHEs (Case 2). Fig. 4. Thermal images of outdoor MCHE before and after refrigerant distribution optimization. Fig. 5. Comparison of heating capacity and HSPF before and after distribution optimization of outdoor MCHE. 4

3. Micro channel heat exchanger for the commercial heat pump system 3.1. Micro channel heat exchanger design The MCHEs are applied to a 65 kw commercial heat pump system, which is a modular air cooled type in China. The refrigerant is R410a. Fig. 6 shows the pictures of the unit. There are four TFHEs in the unit, each of which has 3 rows φ9.52 mm copper tubes. All of the TFHEs are replaced by the MCHEs, and MCHEs have horizontal headers, louver fins and 2 rows vertical 20.6 mm width microchannel tubes. Fig. 7 shows the 3D model picture of two MCHEs. The 2 rows MCHEs are designed to be counter-flow when used as condensers, and they are parallel-flow when used as evaporators. And there are different FPI for each row. The row which transfer heat with the air flow first is 8.5FPI, and the second row is 16FPI. The heat pump system with TFHEs is named case 3, and the heat pump system with MCHEs is case 4. The details of the TFHEs and MCHEs could be found in Table 3. The experiments are performed on the psychrometric calorimeter test bench of Sanhua s customer. The test conditions are shown in Table 4. Fig. 6. Pictures of the 65kW commercial heat pump unit. Fig. 7. 3D pictures of the MCHEs for the 65kW commercial heat pump unit. Table 3. Information of tube & fin heat exchangers (TFHEs) and microchannel heat exchangers (MCHEs) for the commercial heat pump. 5

Case Indoor/Outdoor Coil Type Size Tube Parameter Fin Height FPI (mm mm) (mm) (mm) Row 3 Outdoor Coil 1#&3# TFHE 890*1016 φ9.52 / 16 3 Outdoor Coil 2#&4# TFHE 890*914 φ9.52 / 16 3 4 Outdoor Coil 1#&3# MCHE 889*1017 20.6*1.3 8.1 8.5 & 16 2 Outdoor Coil 2#&4# MCHE 889*919 20.6*1.3 8.1 8.5 & 16 2 Table 4. Test conditions. Water flow rate [m3/(h kw)] Water Temperature ( ) Outdoor Dry-Bulb ( ) Outdoor Wet-Bulb ( ) Cooling 0.172 7 35 - Heating 0.172 45 7 6 Defrosting 0.172 45 2 1 3.2. Experiment results and analysis The performance of the heat pump system with TFHEs (case 3) is compared with the heat pump system with MCHEs (case 4) in this study. As shown in Fig. 8, the cooling capacity and EER of case 4 increases by 2% and 4% separately when compared with case 3. Meanwhile, the heating capacity and COP are same with baseline. Fig. 8 also shows that the weight of heat exchangers in case 4 is only 65% of case 3. And the refrigerant charge of case 4 is only 60% of case 3. The MCHEs are 2 rows parallel-flow design which have different FPI for each row. The refrigerant flow velocity in the microchannel tubes is enhanced by using this 2 rows design, so the heat transfer coefficient in the tube is enhanced, and the oil return risk is reduced greatly. The first row which transfer heat with the air flow first is designed to be 8.5 FPI in order to avoid the blocks of air flow path by frost, and the second row is 16 FPI to increase the heat transfer area as much as possible. Though the refrigerant distribution optimization of 2 rows MCHE is much more difficult than 1 row MCHE when used as evaporator, a good distribution is gotten after optimization. There is no frost remain or drainage issue for the defrosting condition. The system heating capacity and HSPF can meet the target finally. Fig. 8. Comparison of 65 kw commercial heat pump systems using TFHEs (case 3) and MCHEs (case 4). 6

4. Conclusion For the 3Ton residential heat pump system, when compared to the system with TFHEs, the cooling capacity can increase by 4% by using MCHEs, and SEER and HSPF can increase by 2% and 1%. The weight of heat exchangers can be reduced by 44%. And the refrigerant charge can be reduced by 51%. For the 65kW commercial heat pump system, the cooling capacity can increase by 2% by using MCHEs, and EER can increase by 4%. The weight of heat exchangers can be reduced by 35%. And the refrigerant charge can be reduced by 40%. The refrigerant distribution of MCHE can become more uniform by optimizing. And the performance under frosting and defrosting condition can meet the target. And there is no frost remain and drainage issue. It is verified that MCHEs has higher heat transfer performance, much lower weight and refrigerant charge, which is a good choice for improving the efficiency and saving cost. References [1] Satish G. Kandlikar. A Roadmap for Implementing Minichannels in Refrigeration and Air-Conditioning Systemd- Current Status and Future Directions. Heat Transfer Engineering, 28(12):973-985, 2007. [2] Zhaogang Qi, Jiangping Chen, Reinhard Radermacher. Investigating performance of new mini-channel evaporators. Applied Thermal Engineering, 29: 3561-3567, 2009. [3] Liang-Liang Shao, Liang Yang, Chun-Lu Zhang. Comparison of heat pump performance using fin-and-tube and microchannel heat exchangers under frost conditions. Applied Energy, 87: 1187-1197, 2010. [4] Jianghong Wu, Guang Ouyang, Puxiu Hou, Haobin Xiao. Experimental investigation of frost formation on a parallel flow evaporator. Applied Energy, 88: 1549-1556, 2011. [5] Ehsan Moallem, Sankar Padhmanabhan, Lorenzo Cremaschi, Daniel E. Fisher. Experimental investigation of the surface temperature and water retention effects on the frosting performance of a compact microchannel heat exchanger for heat pump systems. International Journal of Refrigeration, 35: 171-186, 2012. [6] Bo Xu, Qing Han, Jiangping Chen, Feng Li, Nianjie Wang, Dong Li, Xiaoyong Pan, Experimental investigation of frost and defrost performance of microchannel heat exchangers for heat pump systems, Applied Energy, 103:180-188, 2013. 7