Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

Similar documents
Danfoss gas detection units

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Conductive Leakage detectors of the Leckstar range

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Consignes d installation

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Multi-Gas-Controller MGC2

OPTISENS TUR 2000 Technical Datasheet

Insulation fault evaluator EDS460-DG

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Remote alarm indicator and test combination MK2430

ACS-30-EU-VIA-DU-20-MOD

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Speed and Frequency Seite 1 von 7

Danfoss gas detection units

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Constant climate chambers

ST Wiring diagram. Product description. Standard temperature controller. Order number

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

HPLC Column Ovens and Temperature Controllers

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Power Flame Incorporated

Octalarm-T: the latest in future-proof industrial alarm diallers

PolyGard 2-channel Gas Controller MGC-03

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Chromatographic Air circulated Refrigerator, two-door TC 603

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

Low Temperature Zirconia Oxygen Analyzer

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Fire detection and alarm

LC1350 Level Controller

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Constant climate chambers

Advantages / Characteristics

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

RTD TEMPERATURE SENSING SYSTEM

LEAKSTOPPER RANGE Multizone water leak detection systems

Ionisation single-tube smoke detector for duct mounting

Monitoring Devices 11/1

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

TM800. Remote alarm indicator and operator panels

Technical Manual. Level Alarm Unit CARLA & WIDS

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Fire control panel detect 3004 plus and accessories

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Refrigerated Incubator Model and Operating Instructions

PRODUCT LINE. Highest Quality, Best Service

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Colour Observation System

Instructions for the BASIC BCRW Fan, Sizes General

SECTION ELECTRICAL IDENTIFICATION

PANTHER. Condensate removal pump Installation and operating guide

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

UV - Monitor UVT 16. Use. Description

NXM2G Installation and Operating Manual

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

laboratory & sterilization technology

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Industrial Strength Leak Detection

On the job around the clock 24/7: Fire detection systems

Vacuum drying oven for non-flammable solvents

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

HYGROPHIL H process hygrometer

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

APPLICATION DATA SHEET

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Transcription:

Leakage Detection WaterAlarmSystems Fuel-oil/WaterAlarms Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

Reservation Technical data is subject to change without notice. No claims for damages arising from changes, errors or misprints shall be allowed. Attention is drawn to the applicable standards and regulations together with the relevant operating and installation instructions. Delivery only via authorized retailer. Issue 01/05 BARTEC GmbH

Contents Sensors SCR sensor cables 2 PS point sensor 3 Electronic monitoring units RLW electronic monitoring unit with leakage locating function, wall-mounted type 4-5 RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type 6 RDA 01 electronic monitoring unit, without leakage locating function, rack-mounting type 7 Fuel Oil/Water Alarms HMW fuel oil/water alarm wall-mounted 8 HMS fuel oil/water alarm plug-socket type 9 Planning and design Notes for planning and design of water-alarm systems 10-11 Installation and connection examples 12 1

Leakage Detection Systems Sensors SCR sensor cables The SCR sensor cable is used for detection of conductive liquids such as water, acids and alkalis. The sensor cable provides a precise location of the leakage. The SCR takes the form of a flexible, four-core, round-section cable with a protective braiding. Features Fast and easy installation High flexibility, supplied complete with connectors or by the meter Technical data Sensors 2 x 0.25 mm² Protected with partially permeable PTFE insulation Colour: red/white Return cores 2 x 0.25 mm², with FEP; Colour: red/white Protective braiding FEP; Colour: natural Cable diameter 5 mm Minimum bend radius 6 x cable diameter Tensile strength 210 N Temperature stability - 50 C to + 180 C Fire performance V 0 according to Fire-safety Standard UL 1581 SCR ordering data Order no. Order no. SCR sensor cable 1 m, with connectors 17-85M1-1761/5000 3 m, with connectors 17-85M1-1761/5200 5 m, with connectors 17-85M1-1761/5300 15 m, with connectors 17-85M1-1761/5500 30 m, with connectors 17-85M1-1761/5700 by the meter 17-85M1-1761 Accessories Connecting cable 5 m, with connectors 05-0068-0070 Connecting cable 5 m, with connectors 05-0068-0071 SCR terminal connector 05-0080-0161 SCR terminating resistance 05-0080-0164 SCR zone divider module 05-0080-0162 SCR T-branch 17-85Z4-3200 Fixing tape (pack 50 items) 05-0091-0045 Marking plate Sensitive sensor cable" 05-2144-0777 " SCR connector fitting set 05-0091-0054 SCR socket fitting set 05-0091-0055 SCR test module 05-0080-0163 2 Basic requirements for one sensor connection: sensor cable, 1 item SCR terminating resistance or 1 end connector for RLW, 1 item SCR connector, 2 items SCR sockets

PS point sensor The point sensor is used for detection of conductive liquids, such as water, for example. This point sensor gives a quick and reliable indication of a leakage. Features Individual connecting lengths Series installation, up to 50 point sensors can be connected Can be combined with the SCR sensor cable Locating function possible Technical data Type Flat point sensor with cable gland and watertight connecting-terminal chamber Dimensions 80 mm x 26 mm height Cable gland M12 x 1.5, cable-diameter range 3 to 6.5 mm Housing material PVC Temperature stability - 10 C to + 50 C Leakage alarm from 3 mm water depth Electrodes Two, stainless steel Electrode spacing 25 mm Connecting terminals Screw-type terminals on input and output Miscellaneous Integrated terminating resistance RLW ordering data PS point sensor Order no. 17-85M1-3832/0A00 3

Leakage Das neue Detection Wasserwarnsystem Systems mit Ortung Electronic monitoring units RLW electronic monitoring unit with locating function, wall-mounted type Features Open-text system display Fast and accurate leak location Monitoring lengths up to 3 000 m System calibration is not required Simple integration into the building control system Can be combined with sensor cable and point sensor The system is used for monitoring of complete rooms or along pipework, can also be used for monitoring of individual items. Any leak is located with meter accuracy and displayed in the Building Control Center, guaranteeing rapid leak location, and permitting immediate corrective action. Performance features Up to 1 500 m of sensor cable can be connected to each measuring channel Measuring channel can be subdivided into up to 50 zones (e.g. Zone 1: Sensor cable 0 m to 50 m) Zones can be entered in open text (e.g. Tradesmen s Area 3 or Air conditioner 8) Display with background illumination (4 x 20 characters) for open-text messages Sensor-break monitoring Power-failure monitoring Software-protected with password Intrinsic system self-monitoring (Watch-dog) Trilingual front-panel text Trilingual menus on display (German, English, French) Length unit: Meter or feet (selectable) 4

Technical data Design Dimensions Inputs Outputs Event memory Measuring accuracy Measuring method Date/time Operating elements Plastic housing for wall-mounting, with transparent cover, connecting-terminal chamber and cable glands 284 x 217 x 143 mm (W x H x D); (Dimension H not including cable gland) - Power supply (standard) 230 V AC or 115 V AC/50 to 60 Hz/8 VA or 12 V/24 V DC/7 W - Sensor connection - Two potential-free changeover contacts per measuring channel (3 A for 230 V AC) for signaling leakage - Two potential-free changeover contacts for Power-failure monitoring (fail safe): 3 A for 230 V AC - RS 232 interface (standard) and RS 485 (variant); Block-oriented, protected single-master protocol for connection to the Building Management System Storage of the 20 most recent events, with date, time and open text ± 0.1 % of upper limit of effective measuring range Conductive (conductive liquids > 30 µs) Automatic summer-/winter-time changeover Touch-type keyboard (for operation of all functions, including input of open text) Signals Visual: LED displays: On/Leak/Breakage/Fault Acoustic: Piezoelectric buzzer (can be switched on/off) Ambient temperature 0 C to + 50 C Degree of protection IP 65 RLW ordering data Order no. RLW electronic monitoring unit with locating function Single channel 17-85G1-2121 Dual channel 17-85G1-2221 RLW electronic monitoring unit with locating function and RS 485 Single channel Dual channel 17-85G1-2122 17-85G1-2222 5

Leakage Detection Systems RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type Features Rapid leak detection Monitoring lengths up to 1 000 m System calibration is not required Simple integration into the building monitoring system Can be combined with sensor cable and point sensor The system detects escaping liquids quickly and reliably. A visual and acoustic alarm is given. Potential-free contacts for signals to the Building Management System (BMS) and for control functions are set simultaneously. Technical data Type Wall-mounted type, with touch-type keyboard and separate connecting-terminal chamber Dimensions 166 x 160 x 84 mm (W x H x D) Inputs Power supply 230 V AC/50 to 60 Hz/8 VA or 24 V DC/7 W standard Sensor via two-wire line max. sensor cable length 1 000 m max. 50 point sensors Outputs Alarm relays, two separate changeover contacts (6 A for 230 V AC/6 A for 24 V DC) Breakage/power-failure relays, 1 changeover contact for fail-safe function (6 A for 230 V AC/6 A for 24 V DC) Memory Alarm/breakage-relays memory Measuring method Conductive (conductive liquids > 2 µs) Reaction sensitivity Adjustable Self-monitoring Sensor breakage and power-failure Operating elements Two-stage Acknowledge/Cancel button (Stage 1: Buzzer off); On/Off button Signals Visual: LED displays: On/Alarm/Break Acoustic: Piezoelectric buzzer Ambient temperature 0 C to + 60 C Degree of protection IP 54 RDW 03 ordering data RDW 03 electronic monitoring unit without leakage locating function, wall-mounted type Order no. 17-85F3-8322 6

RDA 01 electronic monitoring unit without leakage locating function, rack-mounting type Features Rapid leak detection Monitored lengths up to 1 000 m System calibration is not required Simple integration into the Building monitoring system Can be combined with sensor cable and point sensor The system detects even small amounts of leakage quickly and reliably. A visual and acoustic alarm is given. Potential-free contacts for messages to the Building Management System (BMS) and for control functions are set simultaneously. Technical data Type Rack-mounted housing for Mounting Rail TS 35 Dimensions 22.5 x 82 x 101 mm (W x H x D) Inputs Power supply: Type 2322 230 V AC/50 to 60 Hz/1.2 VA Type 2422 24 V DC/0.8 W Sensor connected via two-wire line max. sensor cable length: 1 000 m max. number of point sensors: 50 Outputs Collective-alarm relays, two changeover contacts (0.25 A for 230 V AC/1 A for 24 V DC) Memory Alarm/break-relays memory Measuring method Conductive (conductive liquids > 2 µs) Reaction sensitivity Adjustable Self-monitoring Sensor break and power-failure Operating elements Reset button Alarm Visual: LED displays: On/Alarm/Break Acoustic: Piezoelectric buzzer Ambient temperature - 25 C to + 60 C Degree of protection IP 20 RDA 01 ordering data Order no. RDA 01 electronic monitoring unit without leakage locating function, rack-mounted type 230 V AC 17-85F4-2322 24 V DC 17-85F4-2422 7

Leakage Detection Systems Fuel Oil/Water Alarms HMW fuel oil/water alarm, wall-mounted The BARTEC alarm system provides indication of even the smallest fluid-leaks, e. g. water or fuel-oil, simply and reliably. The tiny sensor head can be installed even in narrow and extremely confined spaces, providing safety for your equipment. Features For water and fuel-oil leaks Ready to use Durable and maintenance-free Automatic reset after repair of leak Sensor break control Function The fuel-oil/water alarm consists of the monitoring device and the point-sensor. The monitoring device provides an alarm via an LED and an acoustic signal if liquid touches the sensor. A potential-free contact for further alarm generators and other devices, such as a siren, indicator light or shut-off valve is switched simultaneously. Directives and approvals Design homologation: DIBT/Z-65.40-391 EMC Directive: 89/336/EWG Low Voltage Directive: 73/27/EWG Technical data Monitoring device Power supply 230 V AC/50 to 60 Hz/1,2 VA Ambient temperature - 10 C to + 60 C Displays LED green: On, LED red: Alarm Acoustic signal Potential-free contact 230 V AC/1 800 VA, 100 V DC/300 W Structure Polyester enclosure, IP 65 with cable clands Potection class II (double insulated) Dimensions 110 x 75 x 55 mm (W x H x D) Power-connector cable 1.5 m, shock proof plug Sensor Dimensions 36 x 16 x 6 mm (W x H x D) Connection cable 2.0 m, flexible PVC cable Structure sensor head PA, Injection-moulded, enclosure Measuring method Optical Ambient temperature - 10 C to + 60 C Sensetivity Alarm signal by getting approx. 3 mm fluid level Fixing via enclosed mounting-clip HMW ordering data HMW fuel oil/water alarm, wall-mounted Order no. 17-85H3-1120 8

HMS fuel oil/water alarm, power-socket The BARTEC alarm system provides indication of even the smallest fluid-leaks, e. g. water and fueloil, simply and reliably. The tiny sensor head can be installed even in narrow and extremely confined spaces, providing safety for your equipment. Features For water/fuel-oil leaks Ready to use Durable and maintenance-free Automatic reset after repair of leak Sensor break control Function The fuel-oil/water alarm consists of the monitoring device and the point-sensor. The monitoring device provides an alarm via an LED if liquid touches the sensor and a further de-energizes the socket outlet at the same time. Directives and approvals Design homologation: DIBT/Z-65.40-391 EMC Directive: 89/336/EWG Low Voltage Directive: 73/27/EWG Technical data Monitoring device Power supply 230 V AC/50 to 60 Hz/1.2 VA Ambient temperature - 10 C to + 60 C Displays LED green: On, LED red: Alarm Max. breaking capacity 230 V AC/1 800 VA, 100 V DC/300 W Structure PPO enclosure, IP 20 Protection class I (prot. each conductor) Dimensions 125 x 67 x 50 mm (W x H x D) Sensor Dimensions 36 x 16 x 6 mm (W x H x D) Connection cable 2.0 m, flexible PVC cable Structure Injection-moulded, PA enclosure Measuring method optical Ambient temperature - 10 C bis + 60 C Sensetivity Alarm signal by getting approx. 3 mm fluid level Fixing via enclosed mounting-clip HMS ordering data HMS fuel oil/water alarm, power-socket Order no. 17-85H2-1120 9

Leakage Detection Systems Planning and design Notes for planing and design of water-alarm systems General notes for planning and installation in buildings with false floors/ceilings Preparation Listing of possible sources of danger (e.g. water pipes, airconditioning systems, etc.) Listing of endangered items and systems (e.g. computing centers, communications cabinets, valuable items, etc.) Marking of all sources of danger and endangered items on the building plan Sensor-system planning Place the route of the sensor cable(s), the location of the point sensors and the electronic monitoring unit(s) on the building plan. An installation diagram showing lengths in meters is not absolutely necessary if the RLW electronic monitoring unit is used, provided the rooms, spaces and objects to be monitored are clearly indicated on the plan. The leak location and zone can be displayed in open text. Monitoring of individual items using point sensors or short lengths of sensor cable. Monitoring of large-area rooms and zones using sensor cables. Install the sensor cable in a meandering pattern on the floor (recommended installation distance = 1 m, or twice the tile spacing). Systematic room/zone monitoring using sensor cable: Install the sensor cable on the floor immediately along the sources of danger, or completely enclosing the danger source. Between individual objects or rooms/zones which are not to be monitored, the sensor cable can be connected to a standard installation cable (e.g. LIYY 4 x 0.5 mm²). Connectors, couplings and zone dividers are provided for this purpose. T-branch junctions, which permit branching within the route of the sensor cable, are also available. Precise leak locating and breakage monitoring remain unaffected. Please request separate Notes on Planning for the T-branch junction. Planning of electronic monitoring units Determine the number and/or the zones of buildings, rooms, floors, areas, to be monitored. Leak-locating function necessary: Yes/No (Depending on item size and inspectability in case of leakage) The RDW and RDA type electronic monitoring units are used for monitoring applications in which no leakage locating function is required. Both sensor cables and point sensors can be connected. See data-sheet for performance features. The RLW type electronic monitoring unit is used for monitoring applications in which the leakage locating function is necessary. Both sensor cables and point sensors can be connected. See data-sheet for performance features. Number of electronic monitoring units A rational number of electronic monitoring units should in all cases be determined using the building plans. 10 Recommendation When a leakage alarm signal to the control room is supplemented by other functions (such as a the closure of individual water supply lines, for example) the planned number of electronic monitoring units should be increased, in order to achieve selective shut-down. The installation of one electronic monitoring unit per building or per zone is recommended in cases in which building sections and/or zones are widely separated from one another.

Installation Retrospective installation of sensor cables and/or point sensors behind false floors/ceilings is possible at any time. The sensor cable should be fixed directly to the painted and dust free floor. Features Simple, direct local connection of sensor cables/meter-lengths of cable to the connectors The highly flexible cable can be easily installed Lengths of cable pre-fitted with connectors, etc., enable rapid installation Easy to fix cabling with self-adhesive fixing tapes No dust is produced during installation, no drilling required (important fo cleanrooms, computing centres, etc.) Necessary installation documents Installation diagram System documentation, consisting of:, data-sheets, installation instructions, notes for installation, operating instructions, commissioning, operating instruction sheets, test report Time of installation All other work, including final cleaning, should have been completed before the sensor cable is installed; this eliminates the danger of damage to the sensor cable as a result of third-party work. Notes for sensor-cable installation The substrate must be dry and clean, and completely free of dust. The sensor cable should be fixed to the floor using self-adhesive fixing tapes at intervals of 1 m. The sensor cable must not be crushed by metal components, since the electronic evaluation system checks the cable for electrical resistance. Ensure that dripping condensed water from pipes or cooling/refrigeration systems is not able to affect the sensor cable. A non-detecting connecting cable or a protecting tube or hose must be used in wall penetration and other points of the building. Warning notices ("Caution! Sensitive sensor cable ) should be affixed at points at which the sensor cable could be subjected to damage. The sensor cable must be in contact with the surface to be monitored (installation over obstructions, such as flush-mounted cable routings, for example, is permissible provided leak-detection can be continued immediately after the obstruction). Enter the length of sensor cable installed on the installation diagram (particularly important in the case of part-lengths with T-branches). The sensor cable s insulation resistance must be checked during and after completion of the installation work before the system is activated (see Test Record). Commissioning and technical data: see System Documentation. Tender specifications and further information can be found at www.wasserwarnsystem.de 11

Leakage Detection Systems Installation and connection examples 1. Installation under a false floor Telecommunications Equipment room Computing center Equipment room Plug connection Terminating connector Zone divider 10 m Leak reference point Connecting cable Sensor cable Air-conditioning system Monitoring unit List of materials Connecting cable Electronic monitoring unit SCR socket/scr connector Warning notices "Caution! Sensor cable, on item at intervals of 5 m SCR sensor cable Quantity Order no. Electronic monitoring unit RDA 01, rack-mounted type, 230 V AC 1 item 17-85F4-2322 or RDA 01, rack-mounted type, 24 V DC 17-85F4-2422 or RDW 03, wall-mounted type, 230 V AC 17-85F3-8322 or RLW single-channel, with locating function 17-85G1-2121 8 m approx. 1 m Sensor cable SCR, running meters 44 m 17-85M1-1761 Accessories Fixing tapes, one item per meter Calculation of sensor-cable length: Area x 1.1 = cable length Example: 40 x 1.1 = 44 m 5 m SCR socket SCR terminating resistance or connector Connecting cable (state required length) 1 m 02-4042-0011 SCR terminating resistance, 220 Ohm, for RDA, RDW 1 item 05-0080-0164 or SCR terminating connector for RLW 05-0080-0161 Fixing tape (pack 50 items) 1 item 05-0091-0045 Warning notice "Sensitive sensors 9 item 05-2144-0777 SCR connector, installation set 1 item 05-0091-0054 SCR socket, installation set 2 item 05-0091-0055 12

2.Installation instructions for wall penetrations "Bare - unprotected" installation of the sensor cable through masonry is not permitted. The zone divider permits optimum separation of leakage detection between two rooms. The offset of the zone divider (10 m) must be taken into account in the installation diagram (see drawing). Example: 50 m sensor cable installed in Room 1 and 30 m sensor cable in Room 2. i.e., 80 m total cable length + 10 m zone divider. The electronic monitoring unit calibrates to 90 m. The connecting cable does not change the overall length. In the case of open-text signals on the display, the room designation can be stored in addition to the meter indication using the "Channel Zone menu. Zone 1: 0 to 50 m Text: e.g. Computer Room 1 Zone 2: 60 to 90 m Text: e.g. Computer Room 2 Up to 50 zones can be implemented. False floor Sensor cable to electronic system 50 m SCR sensor cable SCR zone divider (Offset: 10 m) Connecting cable SCR terminating connector 30 m SCR sensor cable Installation on vertical pipes Fixing tape 3. Installation on pipes Time of installation All pipe installation work must have been completed before the sensor cable is installed, in order to avoid damage to the sensor cable. Notes for sensor-cable installation The pipe must be dry and clean The sensor cable must be protected against condensation water or water from the exterior by means of an isolation system around the pipe Installation of the sensor cable in the open is not permissible if rain, snow or a wet environment may occur Note the technical data for the sensor cable and the connectors The sensor cable must not be crushed against metal items The sensor cable s insulation resistance must be checked during and after completion of the installation work Sensor cable Insulation Installation on horizontal pipes Fixing tape Pipe Sensor cable Sensor cable 13

BARTEC Your Partner for fuel-oil and water alarm systems BARTEC GmbH Max-Eyth-Straße 16 D-97980 Bad Mergentheim Phone: 07931 597-0 Fax: 07931 597-491 info.wasserwarnsystem@bartec.de www.bartec.de/wasserwarnsystem D-UK-BHT150502-09/02-BARTEC WerbeAgentur-215900