Now That You re Living With Sprinklers

Similar documents
HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

The Benefits of Home Fire Sprinklers

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

Illinois Fire Safety Alliance

Opening. Monster Guard. Grades 1-3. Teacher s Guide

Home Fire Sprinkler. Display Guide USE THIS KIT TO CUSTOMIZE THE HOME FIRE SPRINKLER DISPLAY TO MATCH THE REQUIREMENTS IN YOUR JURISDICTION.

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

PROTECT WHAT YOU VALUE MOST

School Fire Safety. A Guide for Educators. saskatchewan.ca

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

HELP THEM PROTECT THEIR WORLD.

The Role of Home Fire Sprinklers in CRR

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

Lesson Plan for Fire Safety Starts with You!

Fire Prevention and Risk Reduction Program

School Fire Safety Checklist

What builders need to know about home fire sprinklers

2015 MPHI. Sound Off with the Home Fire Safety Patrol is made possible by funding from the USDHS/FEMA, Award No. EMW-2O14-FP-OO164.

2019 MPHI. Sound Off with the Home Fire Safety Patrol made possible by funding from the USDHS/FEMA, Award No. EMW-2017-FP-00271, with generous

Office Safety: Housekeeping

Unit 2 Fire Safety (Zone 1)

TIMOTHY R. SZYMANSKI Instructor

Fire Safety Lesson Plan- Fourth Grade. Session 1: Home Escape Planning

Related KidsHealth Links

FIRE PREVENTION AND PROTECTION FACT SHEET

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

In just two minutes, a fire can become life-threatening. In five minutes, a residence can be engulfed in flames.

Academic and Administrative Buildings

Policies - Building Rules and Regulations

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

2 nd Grade Lesson Plan: Plant Life Cycle

Preparing Your Home for Disasters

Residential Sprinkler For Sloped Ceilings

Maintenance Tips for Tenants

FIRE SAFETY IN THE HOME

Chapter 4: Fire Protection Systems

esfr dry pendent sprinkler Vk501 (k14.0)

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

Fire Is... A New Approach to Fire and Life Safety

Solutions for Common Problems

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

CHM 130LL: Lab Safety Name: Answer Key _ Section:

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

District heating at home. It s simple.

RVAC-100 VACUUM CLEANER MANUAL. For Household Use Only

U.S. Fire Administration Fire Safety Checklist. for Older Adults. FA-221/July 2012

freedom residential flush pendent sprinkler vk476 (K4.9)

SCC BULLETIN DPS/SCC Directive Date of issue: December 4, 2002

Construction Set: Smart Home

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Student Activity Book

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

STEP #4: KNOW WHAT TO DO EARTHQUAKE

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

esfr dry pendent sprinkler Vk502 (k14.0)

FIRE SAFETY IN THE HOME

Plant Life Cycle Begins

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA. Page 1 of 6

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

Two light bulbs are in series when all current going through one must go through the other in parallel

Fire & Life Safety Education

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Methodist College Emergency Procedures

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Solatube Daylight Dimmer Installation Instructions

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

quick response horizontal sidewall sprinkler vk360 (K8.0)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

START HERE TO GET YOUR SYSTEM UP AND RUNNING IN MINUTES. Quick Start Guide

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

A. Layout. B. Furniture

Additional Bulletins applicable to all F1RES LL Sprinklers Wall Wetting - Bulletin 007 Design and Installation - Bulletin 140

INSTRUCTIONS AND WARRANTY

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

ELECTRIC FIREPLACE with Remote Control

Fire Evacuation Plan Davidge Hall. UMB POLICE or

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

Home Fires Are Common, Deadly and Preventable

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

Microfast quick response Fusible element hsw sprinkler

Villas I at Snowden Overlook Condominium Suggested Home Maintenance Checklist July 27, 2018

Provided by Fire Safety Solutions for Oklahomans with Disabilities: A joint project of Oklahoma ABLE Tech & Fire Protection Publications at Oklahoma

microfast sr/qr extended coverage pendent sprinkler

NFPA Edition Update

Transcription:

Now That You re Living With Sprinklers

Fire Sprinklers Save Lives When a fire starts, its high temperature causes the fire sprinkler closest to the fire to spray water. The water quickly controls deadly heat, smoke and flames while the fire is still small. That fast action prevents injuries and saves lives. Because they are so effective at life safety and property protection, more and more houses today are being built with fire sprinkler systems installed. Smoke Will Not Set Off Your Fire Sprinklers No matter what you have seen in movies, fire sprinklers do not flow water all at once. And they cannot be set off by smoke. Each fire sprinkler has a glass or metal trigger. Only the heat of a fire can make it work. An Arizona study showed that 90% of the time only one fire sprinkler is needed to control a home fire. HOW HOME FIRE SPRINKLERS WORK pipe (connected to water supply) A typical home fire sprinkler covers a minimum 12 x 12 foot area. liquid-filled bulb bursts at 135-165 F (57-74 C) plug (frees water) sprinkler

KNOW YOUR WATER CONTROLS Main Drain/Inspector Test - this valve is used for testing the system, see the instructions on the back to do the flow test. Control Valve may be here or here Pressure Gauge Water Main Backflow Valve (Not on all systems) Water Flow Switch (optional) Water Supply for Sprinklers Water Meter Water Supply for Plumbing Fire Sprinklers Are Easy To Live With Fire sprinklers are very reliable. You ll be happy to learn that your fire sprinkler system needs little maintenance. The National Fire Protection Association (NFPA) recommends these simple steps: Once a month: Check to be sure all valves are open. If you have a water storage tank, make sure it is full. Test the pump (if you have one), to be sure it starts. Twice a year: If you have a water flow device, test it and your monitoring service (if any). Year-round: Look at all your fire sprinklers and inspect any visible pipes to make sure nothing is hanging from them. Make sure nothing is obstructing any fire sprinkler.

Good Practice Do Not Hang Anything From the Fire Sprinkler Plants, clothing and other hanging items can damage or break the bulb on the fire sprinkler. If that happens, water will flow from the fire sprinkler. Protect Fire Sprinklers from Bumps Be careful when carrying ladders and other large items. Don t bump fire sprinklers or exposed pipes. Teach children not to touch or play with fire sprinklers. Do Not Paint the Fire Sprinkler Or the Cover Paint may stop the fire sprinkler from working correctly. It may take longer for the fire sprinkler to go off or it may not work at all. While doing messy work, such as painting, cover the fire sprinklers with plastic. Important: Remove the plastic as soon as you are finished. Give Your Fire Sprinklers Space If fire breaks out, the fire sprinkler protects your family by spraying water over the fire. Don t block the fire sprinkler with anything. Keep pictures and tall furniture away from fire sprinklers that are installed on walls. Hang lamps and plants away from ceiling fire sprinklers.

Sidewall Fire Sprinkler Concealed Fire Sprinkler Pendent Fire Sprinkler

Understanding Your Water Controls Make Sure The Control Valve Is Always Open The control valve is OPEN when it is parallel or in line with the pipe. The control valve is CLOSED ( turned off ) when it is perpendicular to or makes a corner to the pipe. Use a padlock to keep the valve LOCKED OPEN.. OPEN CLOSED LOCKED OPEN Tape the padlock key to the pipes or a wall nearby so you can find it when you need it. Keep The Area Around Your Water Controls Clear It s a good idea to store items at least one foot (30 cm) away from your water controls. Do a Flow Test Twice a Year You can do this yourself or your fire sprinkler contractor can do it for you. If you want to do it yourself, follow the instructions on the Living With Sprinklers hang tag, or visit HomeFireSprinkler.org.

A System of Fire Safety You Need Working Smoke Alarms and Home Fire Drills Too Even homes with fire sprinkler systems need working smoke alarms installed on each level. Plan how to get out if there is a fire and practice with occasional fire drills.

Find Out More Living With Sprinklers Hang Tag You may have a tag attached to your fire sprinkler controls that explains the parts of your system and how to take care of them. If not, you can download it at HomeFireSprinkler.org. There is no charge. HomeFireSprinkler.org The Home Fire Sprinkler Coalition (HFSC) is a 501(c)(3) nonprofit group. HFSC has all the information you need about fire sprinklers. You ll find answers to your questions, videos, brochures and even games for you and your children. There is no charge to you. SprinklerSmarts.org HFSC has created Sprinkler Smarts just for children. Music, games and activities help young children and middle-school students learn basic fire safety, plus gain an understanding of home fire sprinklers. 2015 Home Fire Sprinkler Coalition