CO2 Sensor User and Installation Guide

Similar documents
esense CO2 Transmitter and Alarm

VX SERIES Wireless Thermostat with Occupancy Sensor

Owner s Manual. PIR-1 IR Learner

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

RK CO 2 Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

CD6102 / CD6102 OC / CD6102-2

CT2 Retro Box Installation Instruction Manual

INSTALLATION INSTRUCTIONS TALKBACK MODULE

RK-05 Combustible Gas Transmitter Operator s Manual

MaxLite LED Vapor Tight Linear Fixture

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

INSTALLATION & OPERATION MANUAL

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Figure 1. Figure 2. See notes 1 and 2 below.

Model 4001 Series Single Channel Controller

RATIO:GUARD Model E-1S EC Monitor

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

RK Transmitter Technical Notice

RK Combustible Gas Transmitter Operator s Manual

Environmental Monitoring SmartSlot Card

ion Genesis Pump Controller

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Industrial Dehumidifier Operating Instructions. Model: VG 1500

RK/ RK Oxygen Detector Operator s Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Warranty Registration

RK-05 Carbon Monoxide Transmitter Operator s Manual

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

C0-210 Carbon Monoxide Probe

Document No

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

TrueClean ToteCleaner

RK Carbon Monoxide Transmitter Operator s Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

OWNERS MANUAL MODEL 451 (-101 & -201)

A2Z Ozone, Inc. PRODUCT MANUAL

Proliphix Thermostat Installation Guide. Release 2.0

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Ozone + UV Sanitation

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

User Guide. for the Beacon ProActTM 200 System

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Installation Instructions

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

Static Pressure Control

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

MaxLite LED High Bay Fixtures

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTRUCTION MANUAL HS-229G

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Non-Programmable Digital Thermostat

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

Combustible Gas Sample-Draw Detector Operator s Manual

Safety, Installation, and Operation Manual

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

OPERATION MANUAL. CLASSIC PLUS 14 and CLASSIC PLUS 26 ~ SECTION EN FRANÇAIS

Home Theater Interface Plate INSTALLATION INSTRUCTION

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Installation & Operation Manual

SKORPION Process Air Heater

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

! "! # Please read these installation and operating instructions completely and carefully before starting.

TrueClean ToteCleaner

Carbon Dioxide Sample-Draw Detector Operator s Manual

Duct Mount. Installation Instructions

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

RK / RK CO 2 Detector Operator s Manual


Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

BioZone Scientific International contact information

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Controllers. Instruction Manual WARNING

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Quest Power Electric Heat EHS 62 Pro

Transcription:

CO2 Sensor User and Installation Guide P/N: 110227

WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one) year from the date of initial installation on site (the "warranty period"). 2. Load cells are not covered by ROTEM s warranty. 3. ROTEM warrants that during said warranty period, any item/items or part/parts of equipment found defective with respect to materials or workmanship or which do not conform to the technical specification shall be repaired or replaced (at ROTEM's sole discretion), free of charge. 4. During the warranty period, in the event of an alleged defect, authorized resellers in relevant regions should be notified as soon as possible from the date of noticing the said defect, but no longer than thirty (30) days from such a discovery. The report shall include (1) a short description of the defects noticed (2) type of card / component and its matching serial number. 5. ROTEM's sole liability under this warranty is the repair or replacement of the defective item of product. Conditions and Limitations 1. ROTEM will not be responsible for any labor costs or expenses associated with replacement of defective items or other parts of the product or repair. 2. This warranty shall not cover: (i) product or part therein which has been modified (without prior written approval of ROTEM), or (ii) product or part therein which has not handled or installed by an authorized reseller of ROTEM or (iii) product or part therein which has either handled or installed not in strict accordance with ROTEM's instructions, (iv) products which were used for function other than agriculture industry. 3. This warranty will not apply in the following cases: (i) if all components of the product are not originally supplied by ROTEM (ii) the defect is the result of an act of nature, lighting strikes, electrical power surge or interruption of electricity (iii) the defect is the result of accident, misuse, abuse, alteration, neglect, improper or unauthorized maintenance or repair. ROTEM warns and alerts all users that the Product is inherently complex and may not be completely free of errors. ROTEM's products are designed and manufactured to provide reliable operation. Strict tests and quality control procedures are applied to every product. However, the possibility that something may fail beyond our control exists. Since these products are designed to operate climate control and other systems in confined livestock environments, where failure may cause severe damage, the user should provide adequate backup and alarm systems. These are to operate critical systems even in case of a ROTEM system failure. Neglecting to provide such a backup will be regarded as the user s willingness to accept the risk of loss, injury and financial damage. In no event will ROTEM be liable to a user or any third party for any direct, indirect, special, consequential or incidental damages, including but not limited to any damage or injury to business earnings, lost profits or goodwill, personal injury, costs of delay, any failure of delivery, costs of lost or damaged data or documentation, lost or damaged products or goods, lost sales, lost orders, lost income. Except for the above express warranty, ROTEM makes no other warranties, express or implied, relating to the products. ROTEM disclaims and excludes the implied warranties of merchantability and fitness for a particular purpose. No person is authorized to make any other warranty or representation concerning the performance of the products other than as provided by ROTEM. Software Version: 1.0 Document Version: 1.5

TABLE OF CONTENTS 1 Introduction... 5 1.1 Features... 5 1.2 Operating Mode... 6 2 Installation... 7 2.1 Installing the Sensor... 7 2.2 Controller Connection... 9 2.3 Calibrating the Device... 10 2.4 Disconnecting the Sensor... 11 3 Maintenance and Care... 12 4 Specifications... 12 5 Troubleshooting... 12

1 INTRODUCTION The CO2 Sensor measures CO 2 levels in an agricultural environment. Working in conjunction with a controller, the CO2 Sensor sends a signal when the measured CO 2 levels fall outside the user-defined specifications. This signal activates the controller s ventilation. Refer to Figure 1. Figure 1: CO2 Sensor NOTE: The unit comes supplied with a 12 VDC supply. 1.1 Features Self-contained environment and impact-resistant sealed box Quick open clasps Easy installation Simple to connect and configure Continuous uninterrupted CO2 sensing Diagnostic LEDs Door-mounted sensor 5 CO2 Sensor

1.2 6BOperating Mode The CO2 Sensor operates in a Current Loop mode (4-20 milliamps). In this mode, the CO 2 Sensor provides a signal proportional to CO 2 levels. NOTE: Verify that J2 is not shorted (refer to Figure 2). Figure 2: J2 Jumper CO2 Sensor 6

2 INSTALLATION This section details: Installing the Sensor Calibrating the Device 2.1 Installing the Sensor The CO2 Sensor comes with an extension cable that is used to: Connect the sensor to a power source Connect the sensor to the Platinum Controller (Figure 10, page 9) Detach the unit from the house during cleaning and maintenance procedures (Disconnecting the Sensor, page 11) Figure 3: CO2 Sensor Attached to Connector To install the unit: 1. Mount the sensor in place. 2. On the female plug, remove the retaining screw from the protective cover (Figure 4). Figure 4: Protective Cover 3. Pull out the connector from the protective cover (Figure 5). Figure 5: Remove the Connector 4. Place the cable through the protective cover (Figure 6). 7 CO2 Sensor

Figure 6: Threading the Cable 5. On the top of the connector are numbers (Figure 7. Each wire must be attached to the corresponding port (Table 2). Connect the four wires to the connector Figure 8. Figure 7: Connector Numbers Table 1: Connecter Port Functions Port Number Function Wire Color 1 +12 V Red 2 12 V Com (-) Black 3 SIG Out White 4 SIG Com Green Figure 8: Wired Connector 6. Place the wired connector back into the protective cover and place the retaining screw in place (Figure 9). Figure 9: Wired Unit in Protective Cover CO2 Sensor 8

2.2 Controller Connection 1. Attach the other end of the cable to the power supply and Platinum Analog Input Card as indicated in Figure 10. 2. Connect: CO2 COM to COM CO2 output signal to the T5 or T6 terminal 3. Place a jumper on the T5 or T6 pins (sets the 4 20 ma mode). Figure 10: Power Supply Wiring CAUTION Connect the shield to the safety ground. 9 CO2 Sensor

2.3 9BCalibrating the Device Figure 11: Jumpers The C02 sensor comes calibrated. In normal conditions fresh air should have approximately 350-450 ppm CO2. Calibrate the device if the following conditions are met: The CO2 sensor is exposed to fresh air or a room with open windows The sensor reading is above 550 To calibrate the sensor: 1. If connected, disconnect the device from the controller. 2. Place the sensor on a steady base (in an area with fresh air or in a room with open windows). 3. Apply 12V DC power. 4. Operate the CO2 sensor for five minutes to stabilize the device. 5. Using the supplied jumper, short the Background jumpers for 10 seconds as shown in Figure 12. Figure 12: Shorting the Background Jumpers 6. Remove the jumper. 7. Disconnect the power and (re)connect the sensor to the controller. CAUTION Do not short the Zero jumpers; they are for factory-calibration only. NOTE: If the device reading is still above 550 when exposed to fresh air, repeat the process. CO2 Sensor 10

2.4 Disconnecting the Sensor Before cleaning the poultry/animal house, disconnect the CO2 sensor. To disconnect the sensor: 1. Dismount the sensor from the wall. 2. Separate the male and female plugs. 3. Place the plug cap on the female cap. Figure 13: Plugs Separated 4. Snap the cap into place. Figure 14: Cap in Place Figure 15: Cap Snapped into Place 11 CO2 Sensor

3 2BMAINTENANCE AND CARE The CO2 Sensor requires little or no maintenance. The following are general maintenance rules: Avoid damaging the CO2 Sensor box Avoid contact with water or other fluids (when you clean the poultry house, remove the box) Ensure sensor grill on front box panel is clean and clear of obstructions NOTE: Water may damage the sensor; therefore minimize exposure while washing, or using water for any purpose. 4 3BSPECIFICATIONS Input signal Output signal Operating temperature CO2 range Accuracy 1% Maximum cable length Minimum wire size Power supply 5 4BTROUBLESHOOTING 12 VDC 4 20 mamp 10 º - 70º C 0 5000 ppm 300 meters 22 AWG 12 VDC The field technician diagnostic LEDs are visual diagnostic indicators for the field technician only. They are not end-user serviceable parts or indicators. Table 2 details possible system failure issues. Table 2: CO2 Sensor System Failure Issues Problem The Sensor Fail LED is lit when CO2 sensing element fails. The Min.Fail or Max. Fail LED is lit: The sensor is out of acceptable range. If the diagnostic LEDs are lit (D2, R12), indicates that the circuit may be incomplete. Readings are off the scale, even when fresh air is present. Readings are lower than expected. Power LED remains unlit Solution Replace CO2 sensing element Replace CO2 sensing element Check circuitry for breaks Verify that there is a jumper on the Platinum Analog card, placed on T5 or T6, set for 4 20 ma (refer to Figure 10). Remove jumper from J2 terminal (refer to Figure 2). Check if power/com wiring has been reversed (refer to Table 1). CO2 Sensor 12