H-MOSS Occupancy Sensors Control Units and Add-A-Relay

Similar documents
H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Section D. H-MOSS Occupancy Sensors Index. Wall Switches. Wall and Ceiling Mount. Sensors. Residential and Vacancy. Sensors

H-MOSS. Sensors for an Energy Conscious World

0ACDT2000MV Ultasonic/Infared Occ Sensor

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Interior Control Solutions

Mini Product Guide.

Sensors and Detectors

Lighting Control Strategies. to meet code requirements save energy and improve building performance

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Occupancy Sensor Selection Guide

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

SECTION. Occupancy Sensors & Lighting Control Products

Ever evolving energy code requirements and the large demand for energy

180 Degree Ceiling Mounted Occupancy Sensors

Never forget to turn the lights off again. Motion Sensors

LIGHTING CONTROL DEVICES

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

Installation Instructions

Versatile wall switch sensors maximize payback and simplify code compliance

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

A. This Section includes the following lighting control devices:

ENERGY EFFICIENCY EXPERTS

A. This Section includes the following lighting control devices:

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Installation Instructions

Sensors and Timers P&S. designed to be better. A COMPLETE LINE FOR ENERGY SAVINGS AND CONVENIENCE.

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

National Grid Small Business Program Rebate Manual

GE LightSweep Lighting Control System Guideform Specification

Installation Instructions

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

Movement-based energy control

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

SECTION LIGHTING CONTROL DEVICES

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

Infrared Wall Mount Occupancy Sensor

Wherever the best is needed. Sensors for professionals.

Office Title Solutions

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

FR-A180 FR-A360. Occupancy detector. Use

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Energy Management Products

Low-Voltage Occupancy Sensors

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Maestro 0 10 V Dimmer Sensor

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Maestro Dual-Circuit Occupancy Sensing Switch

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Catalog Number. Notes

Education Title Solutions

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

The Power To Supply... All Your Electrical Products

IN2 Lighting Control Devices

Installation Instructions

Occupancy Sensor Operation with Lighting Fixtures

CONTENTS SENSOR SWITCH

DIMMING WASP Occupancy and Daylight Sensor

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

High Performance Lighting. Terry Egnor Senior Consultant NBI

LOS SUPER CEILING SENSOR Installation Manual

From: Commander, Naval Facilities Engineering Command (Code 15C) To: Distribution OCCUPANT SENSORS, INTERIM TECHNICAL GUIDANCE (ITG)

Applied Lighting Controls

Wireless Plug Load Control

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

VESICA LINEAR SUSPENDED VES L

INTEGRATED LIGHTING CONTROLS

PMCSF6 OCCUPANCY SENSOR

Emery County Senior Center Green River 06/07

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Sensors Explained AUTOMATION

GS-12 GREEN SEAL STANDARD FOR OCCUPANCY SENSORS FIRST EDITION FEBRUARY 14, 1997

Healthcare Title Solutions

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

LIGHTING CONTROLS

Technical Application Guide

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

APPENDIX E LIGHTING CONTROL DATA

IP65 High Bay Dual Sense Sensor

Residential Occupancy & Vacancy Sensors

SECTION LIGHTING CONTROLS

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

PIR Occupancy & Motion Sensor

Transcription:

Control Units and Add-A-Relay Control Units Hubbell CD series control units are required for use with Hubbell ATD, ATU, ATP, and PIR series ceiling and wall mount occupancy sensors. The control units provide a V DC power supply for 1 to 3 sensors or sensor/add-a-relay combinations and contain an internal relay for the control of an external lighting load. Control Unit, 1V AC, 60 Hz, for use with ATD, ATU, ATP, Control Unit, 230V AC, 0/60 Hz, for use with ATD, ATU, ATP, Control Unit, 277V AC, 60 Hz, for use with ATD, ATU, ATP, Control Unit, 347V AC, 60 Hz, for use with ATD, ATU, ATP, CU1A CU230A CU277A CU347A CU1A, CU230A CU277A, CU347A Add-A-Relay Hubbell AAR Add-A-Relay is designed for use with Hubbell CU series control units and Hubbell ATD, ATU, ATP, and PIR series ceiling and wall mount occupancy sensors. The AAR contains an internal relay for control of an external lighting load. The AAR requires a V DC power supply from the Hubbell CU series control unit. The AAR is typically used when: 1) It is desired to switch more than one circuit when occupancy is sensed. 2) The lighting load exceeds the maximum rating of the control unit. Catalog Number Add-A-Relay, for use with CU series control units. AAR AAR Note: See pages D-17-19 for technical data and wiring schematics. Dimensions in Inches (mm) www.hubbell-wiring.com HUBBELL) Wiring Device-Kellems ^^V \ I Jj<^S D-11

Adaptive Technology Wall Switches Hubbell wall switch occupancy sensors utilize passive infrared technology to determine occupancy. These sensors require line of sight to detect body heat in motion. Wall switch occupancy sensors are best suited for small enclosed spaces such as offices, conference rooms, storage closets, small lunch rooms, and copy rooms. Hubbell's complete offering of wall switch sensors enables you to choose the right product for these various applications. Hubbell AT series wall switches incorporate Adaptive Technology for performance critical applications such as enclosed offices and conference rooms. Adaptive Technology sensors automatically adjust the time delay setting to fit the application. This prevents false-offs that result when a sensor's time delay is too short for the activity level of the occupant. Product features and benefits are provided on page D-3. AT1I, AT1W, AT277I, AT277W 1V AC, 2 to 00 watts, 10 sq. ft. coverage, with photocell. 277V AC, 2 to 00 watts, 10 sq. ft. coverage, with photocell. AT1I AT1W AT277I AT277W Hubbell ATP series Adaptive Technology wall switch sensors are dual voltage rated for use on 1V or 277V AC applications. These sensors feature a pushbutton ambient light level control that allows for quick, accurate setting of the ambient light level threshold. ATP1277I,ATP1277W ATP1277GY 1/277V AC. 800 watts at 1V AC, 10 watts at 277V AC, 10 sq. ft. coverage, with photocell. Same as above except gray. Notes: Nylon wall plate supplied with each sensor. AT and ATP series wall switch sensors are gangable. See section K for additional wall plates. See pages D-14 for technical data and wiring schematics. ATP1277I ATP1277W ATP1277GY o 0 Horizontal Coverage _, ~(3.0m) (6.1m) 14." (36.8cm) Mounting Height 42" to 4" (6.7 137.2cm) Vertical Coverage \2 Of See Horizontal View for Range D-4 HUBBELL Wiring Device-Kellems www.hubbell-wiring.com Dimensions in Inches (mm)

Adaptive Technology Ceiling Sensors Dual (Ultrasonic and ) x lli/j Vm.'///I %W» ATD00CRP, ATD00C,11'^ Hubbell ATD series sensors incorporate both ultrasonic and passive infrared detection technologies. These dual technology sensors provide the most reliable means of automatic lighting control. Common applications include open office spaces, conference rooms, classrooms, and executive offices where flawless performance is necessary. An isolated relay and photocell are included on models with "RP" suffix. A CU series control unit is required for use with ATD series sensors. ultrasonic-32 khz), 00 sq. ft. coverage, with isolated relay ultrasonic-32 khz), 00 sq. ft. coverage. ultrasonic-32 khz), 00 sq. ft. coverage, with isolated relay ultrasonic-32 khz), 00 sq.ft. coverage. ultrasonic-40 khz), 00 sq. ft. coverage, with isolated relay ultrasonic-40 khz), 00 sq. ft. coverage. ATD00CRP ATD00C ATD00CRP ATD00C ATD00CRP ATD00C Notes: A CU series control unit is required for use with ATD series ceiling sensors. See page D-11 for control units and Add-A-F!elay. ATD00CRP, ATD00C ATD00CRP, ATD00C opassive Infrare oultrasonic 30 2 0 2 30 0 2 30 0 22LJ2" ^@f ATD00CRP, ATD00C ATD00CRP, ATD00C ATD00CRP, ATD00C D-6 Wiring Device-Kellems www.hubbell-wiring.com Dimensions in Inches (mm)

Adaptive Technology Ceiling Sensors Ultrasonic Hubell ATU series sensors detect occupancy based on an ultrasonic signal. Since these sensors do not require line of sight to detect occupancy, they work particularly well in areas with obstructions such as restrooms and storage rooms. Another common application is hallways. An isolated relay and photocell are included on models with "RP" suffix. A CD series control unit is required for use with ATU series sensors. 00 sq. ft. coverage, with isolated relay 00 sq. ft. coverage. 00 sq. ft. coverage, with isolated relay 00 sq.ft. coverage. Adaptive Technology, ultrasonic-40 khz, 00 sq. ft. coverage, with isolated relay Adaptive Technology, ultrasonic-40 khz, 00 sq. ft. coverage. ATU00CRP ATU00C ATU00CRP ATU00C ATU00CRP ATU00C Notes: A CU series control unit is required for use with ATU series ceiling sensors. See page D-11 for control units and Add-A-Relay. / ///*i-«n» : ATU00CRP, ATU00C iin'f/^ ATU00CRP, ATU00C ATU00CRP, ATU00C Ultrasonic 30 2 0 2 30 0 2 30 3 0 2 30 3 0 ATU00CRP, ATU00C e _ - - - / o - - 9 1 ATU00CRP, ATU00C,- a ATU00CRP, ATU00C Dimensions in Inches (mm) www.hubbell-wiring.com QJH^?^ Wi " n9 Detfice - Kellen «i D-7

Ceiling and Wall Mount Sensors PIR00C, PIR00C Hubbell PIR series sensors detect occupancy based on a passive infrared signal. The ceiling mount model is available with a wide view lens for large areas with multiple occupants and a high density lens for areas with a single occupant where small motion detection is desired. The wall mount model is available with wide view and hallway coverage patterns and includes a photocell for ambient light level control. A CD series control unit is required for use with PIR series sensors. Passive infrared ceiling sensor, wide view lens, 00 sq. ft. coverage. Passive infrared ceiling sensor, high density lens, 00 sq. ft. coverage. Passive infrared wall mount sensor, wide view lens, 1600 sq. ft. coverage, with photocell. Passive infrared wall mount sensor, hallway lens, 7 linear ft. coverage, with photocell. Passive infrared ceiling sensor, wide view lens, 00 sq. ft. coverage, V AC, for use with Direct Digital Control (DDC) Systems. Adapter plate for use with PIR00C, PIR00C,, or LON1C when mounting on a 4" octagonal flush steel box and concrete ring. PIR00C PIR00C PIR1600W PIR90HW1 HMCAP Notes: A CU series control unit is required for use with PIR series ceiling and wall mount sensors. See page D-11 for control units and Add-A-Relay. PIR1600W, PIR90HW1 0 2 30 3 40 0 30 40 0 60 70 80 0-9 PIR90HW1 2 30 3 40 Catalog # PIR00C A(ft.) 28 B(ft.) PIR1600W PIR00C D- HUBBELL Wiring Device-Kellems www.hubbell-wiring.com Dimensions in Inches (mm)