Radio fire detection system

Similar documents
SWING radio fire detection system

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDM273 Radio manual call point Mounting

FDCW241 Radio gateway Mounting

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

DM1131 / DM1133 / DM1134 Manual call points

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DOW1171 / DCW1151 Radio fire detection system

FDOOT221, FDO221, FDT221

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

OH720, OP720, HI720, HI722

Multi line separator module

Output module (230 V)

FDOOT241-9, FDOOT241-A, FDO241, FDT241

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Input module, input/output modules

Input module, input/output module

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Mimic display driver, LED ribbon cable

DT1101A / DT1102A / DO110xA Automatic fire detectors

ASA linear smoke detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Fire control panels FC360

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Room thermostat with 24-hour time switch and large LCD

OOH740-A9-Ex Multisensor fire detector

FC2040. Fire control panel. Sinteso. FS20 series, MP6

OOH740, OOHC740 Automatic fire detectors

Electronic timeswitch

FDCL221-M Multi line separator module

OOH740-A9-Ex Multi-sensor fire detector

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Test units and accessories

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Duct Temperature Sensors

FT2080 Fire terminal (Touch) Mounting Installation

FDCIO223 (ES 45) Transponder

Fire control panels FC726 FC726-XA

FT2080 Fire terminal (Touch) Mounting Installation

DF1151-Ex Infrared flame detector

Fire control panel for modernization

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FC722 Fire control panel

FC724 Fire control panel

Test units and accessories

Cerberus FIT conventional system

FC723 Fire control panel

Frost Protection Thermostat

FC2020 Fire control panel

XC10 Extinguishing control panels

Call stations and extensions

FDCL221-Ex Line adapter (Ex)

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

Room thermostats with LCD RDD100..

Room Temperature Controllers

FC722 Fire control panel

DC1192 Input /Output module

FC724 Fire control panel

FDL241-9 Linear smoke detector Mounting Commissioning

Wireless room thermostat with LCD

FDCI221, FDCIO221 Input module, input/output module Technical Manual

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

FDBZ290 Air sampling smoke detection kit Technical Manual

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Room Temperature Sensors

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDOOT241-A9-Ex Automatic fire detector Technical Manual

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Room Temperature Controller

Test units and accessories

Room thermostat with independent DHW control

DF1101-Ex Infrared flame detector

EU Declaration of Conformity

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDCL221 Line separator

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Synova TM product catalog.

Room thermostat with Auto Timer, independent DHW

Frost Units for air temperature monitoring

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature Sensor

XC10 combined fire detection and extinguishing control

EU Declaration of Conformity

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Semi flush-mount room thermostats

EU Declaration of Conformity Lampenwerk Wipperfürth

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

RVL479. Heating Controller. for use with a partner unit

EU eclaration of Conformity

Sinteso TM product catalog.

Flush-mounted room thermostat

Transcription:

OEM Radio fire detection system FDOOT271-O, FDM273-O, FDM275-O Radio fire detection system Multihop mesh technology High transmission reliability thanks to the use of independent communication paths transmission takes place via at least two communication paths Long range thanks to radio transmission via up to two intermediate stations Low power consumption 2016-11-24 Control Products and Systems

Use Typical application areas Rooms of a high historical value, e.g.: Museums Churches Libraries Rooms that only permit brief interruptions in operation while the fire detection installation is being installed, e.g.: Hotel rooms Executive offices Conference facilities Extension of existing sites with minimum wiring work; e.g.: Industrial premises undergoing a change in use Offices whose layout is being changed Goal and purpose In functional buildings, fire detection installations are optimized, planned, and set up in a way that suits the needs of the first group of users. As experience has shown, however, even this group's requirements can become outdated in just a short time due to growth in the company as well as changes in the building's use and structures resulting in the need for structural adaptations. Type Overview Radio fire detector FDOOT271-O and detector base FDB271 FDOOT271-O Radio fire detector S54323-F312-A1 0.132 FDB271 Detector base S54319-F12-A1 0.038 BAT3.6-10 Li-SOCl2 Batt.Pack 3.6 V, 10 Ah S54370-Z11-A1 0.093 Accessories for base FDB271 FDBZ293 Detector locking device A5Q00005035 0.001 FDBZ291 Designation plate A5Q00002621 0.002 FDZ291 Detector dust cap A5Q00004814 0.003 Radio manual call point FDM273-O FDME273-O Switching unit for FDM273-O S54323-B311-A1 0.098 FDMH273-R Red housing, with glass insert DMZ1196-AC and key DMZ1195 S54323-B109-A1 0.279 BAT3.6-10 Li-SOCl2 Batt.Pack 3.6 V, 10 Ah S54370-Z11-A1 0.093 2

Accessories and spare parts for radio manual call points FDM273-O DMZ1197-AC Protective cover BPZ:5223550001 0.012 DMZ1196-AC Glass insert BPZ:4942050001 0.011 DMZ1195 Key BPZ:4851910001 0.001 Radio manual call point FDM275-O FDM275-O Radio manual call point S54323-F310-A1 0.216 BAT3.6-10 Li-SOCl2 Batt.Pack 3.6 V, 10 Ah S54370-Z11-A1 0.093 Accessories and spare parts for radio manual call points FDM275-O FDMC295 Protective cover A5Q00013440 0.036 FDMG295 Glass insert 'Neutral' A5Q00013442 0.012 FDMP295 Plastic insert 'Neutral' A5Q00013445 0.008 FDMK295 Key A5Q00013448 0.001 Other accessories FDUZ227 MCL-USB adapter (radio) S54323-F106-A1 0.188 FDCH271 Housing base for radio gateway S54370-N45-A1 0.054 FDCH272 Housing cover for radio gateway S54370-N46-A1 0.042 OEM components FDRA272-O Antenna (pre-assembled) S54323-N113-A1 0.018 FDRF272-O Radio module S54323-B114-A1 0.004 3

Description of the devices Radio fire detector FDOOT271-O Consistent response to a wide range of different fires Dynamic analysis of the sensor signal in the detector itself Built-in diagnosis algorithms with automatic selftest High degree of immunity to false alarms and environmental influences High-quality opto-electronic sensor system Automatic compensation for soiling Radio fire detector can be mounted anywhere in a radio cell Detector can be inserted and removed using the detector exchanger tool up to a height of 8 meters Functions: Several danger levels: Enable activation of differentiated measures and an early warning in the case of incorrect application. Selftest: The detector performs a comprehensive selftest periodically or on command. Signal processing: Several parameter sets enable optimum signal processing for different fields of application. This ensures excellent interference immunity and operational reliability. Measurement compensation: Ensures the detector demonstrates a virtually identical level of sensitivity throughout the operating period. The integrated alarm indicator shows the alarm on site. Supply: The fire detector FDOOT271-O is supplied with power by a battery pack (AA lithium batteries). The batteries must not be inserted until the time of commissioning. Detector base FDB271 Base for radio fire detector FDOOT271-O. Once the battery has been connected, the detector must not be inserted into the base until the time of commissioning. 4

Radio manual call point FDM273-O Radio manual call point can be mounted anywhere in a radio cell The radio manual call point consists of a housing and a switching unit including radio electronics and dual-band antenna Indirect alarm activation by smashing the glass insert and pressing the alarm button A protective cover (accessories) protects the manual call point against the glass being broken accidentally Supply: The radio manual call point FDM273-O is supplied with power by a battery pack (AA lithium batteries). The batteries must not be inserted into the switching unit until the time of commissioning. Radio manual call point FDM275-O Radio manual call point FDM275-O can be mounted anywhere in a radio cell. The radio manual call point consists of a housing and a switching unit including radio electronics and dual-band antenna The alarm is activated directly by pressing the plastic insert. A key is used to reset the radio manual call point and restore readiness for operation. A protective cover (accessories) protects the manual call point against accidental activation. Supply: The radio manual call point FDM275-O is supplied with power by a battery pack (AA lithium batteries). The batteries must not be inserted into the switching unit until the time of commissioning. Description of consumables Battery pack BAT3.6-10 For supplying radio devices with power Lithium batteries BAT3.6-10 LI-SOCI2 battery pack 3.6 V, 10 Ah. Batteries with cable and connector with protection against polarity reversal Inscription field for commissioning date Service life of at least three years in normal operation Battery monitoring to ensure remaining life of at least six months by connecting a backup battery. Compatible with components which include the following: Radio fire detector FDOOT271-O Radio manual call point FDM273-O Radio manual call point FDM275-O 5

Product documentation Document ID A6V10425624 A6V10425645 A6V10425652 A6V10347735 A6V10960086 A6V10933611 Name Technical Manual Radio fire detector FDOOT271-O Technical Manual Radio manual call point FDM273-O Technical Manual Radio manual call point FDM275-O Installation MCL-USB adapter (radio) FDUZ227 Data sheet Housing base for radio gateway FDCH271, Housing cover for radio gateway FDCH272, Antenna (pre-assembled) FDRA272-O Data sheet Radio module FDRF272-O You will find more information in the manufacturer's fire detection installation technical manual. Notes Operation EU Directive 2011/65/EU (RoHS) Disposal Use Consider the range between radio gateway and radio devices. The building structure can have a significant effect on the radio range (materials such as steel, concrete, lime sand brick, wood, etc.). Mesh technology provides a means of bypassing difficult points with up to two intermediate stations. Limitations The range can be restricted in rooms with a high level of transmission field damping, such as those with a framework of metal bars used as a partition or with metallic storage racks. Power supply The radio fire detector FDOOT271-O and the radio manual call points FDM273-O and FDM275-O are supplied with power by the battery pack BAT3.6-10. The same type of battery can be used for each device. The batteries have a service life of at least three years in normal operation. Thanks to battery monitoring, a backup battery can be connected to achieve a remaining life of at least six years. The device does not contain any substances in concentrations and applications that are prohibited by the Directive 2011/65/EU (RoHS Directive). The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. 6

Technical data Device General (irrespective of the device) Sending/receiving aerials Dual band aerial Radio frequencies 433.05 434.79 MHz band 44b and 45b 1 868 870 MHz band 48, 49, 50, 54b, and 56 1 Number of channels 868 870 MHz band: 27 433.05 434.79 MHz band: 20 Channel grid 50 khz Transmitting power 10 mw ERP in band 44b, 45b, and 49 1 Range Supply Typ. 10 (max. 25) mw ERP in band 48, 50, 54b, and 56b 1 Indoors: Max. 180 m Outdoors: Max. 1000 m Battery pack BAT3.6-10 (to be ordered separately) 1 2013/752/EU: according Official Journal of the European Union, COMMISSION IMPLEMENTING DECISION of 11 December 2013 amending Decision 2006/771/EC on harmonisation of the radio spectrum for use by shortrange devices and repealing Decision 2005/928/EC (notified under document C(2013) 8776) (Text with EEA relevance) Electromagnetic compatibility FDOOT271-O FDM273-O FDM275-O 100 khz 2.5 GHz: 30 V/m 10 khz 100 khz: 160 V/m 100 khz 2.5 GHz: 30 V/m Permissible wind speed Max. 5 m/s Battery service life > 3 years > 3 years > 3 years 10 khz 100 khz: 160 V/m 100 khz 2.5 GHz: 30 V/m Operating temperature -10 +55 C -10 +55 C -10 +55 C Storage temperature -30 +75 C -30 +75 C -30 +75 C Air humidity (no moisture condensation) Protection category (IEC 60529) 95 % rel. 95 % rel. 95 % rel. IP44 IP44 IP24D Color RAL 9010 pure white RAL 3000 flame red RAL 3000 flame red Dimensions Ø 117 x 64 with FDB271 135 x 135 x 58 87 x 87 x 63 Standards 1 EN 54-5, EN 54-7, EN 54-25 EN 54-11 (type B indoors) EN 54-25 EN 54-11 (type A indoors) EN 54-25 Approvals VdS: G216094 VdS: G216095 VdS: G216096 1 You will find more information about standards in the information about CE marking below 7

16 16 16 0786 FDM273-O Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. A6V10425645 FDM273-O - Manual callpoint using radio link for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-25 ; 2014/53/EU (RED): EN 300 220-2 / EN 301 489-3 / EN 60950-1 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21528; DoC No.: CED-FDM273-O 0786 FDM275-O Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. A6V10425652 FDM275-O - Manual callpoint using radio link for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-11 / EN 54-25 ; 2014/53/EU (RED): EN 300 220-2 / EN 301 489-3 / EN 60950-1 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download 0786 DoP No.: 0786-CPR-21529; DoC No.: CED-FDM275-O Siemens Switzerland Ltd; Gubelstrasse 22 CH-6301 Zug Technical data: see doc. A6V10425624 FDOOT271-O - Smoke/heat detector using radio link for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-5 / EN 54-7 / EN 54-25 ; 2011/65/EU (RoHS): EN 50581 ; 2014/53/EU(RED): EN 300 220-2 / EN 301 489-3 / EN 60950-1 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0786-CPR-21527; DoC No.: CED-FDOOT271-O Dimensional drawings Radio fire detector FDOOT271-O with detector base FDB271 117 Radio manual call point FDM273-O Radio manual call point FDM275-O 64 135 87 87 63 135 58 All dimensions in [mm] Issued by Siemens Switzerland Ltd Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2014 Technical specifications and availability subject to change without notice. 8 Document ID Edition 2016-11-24