SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

Similar documents
SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

SS-3N Express Lavatory System SS-Series

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Express Lavatory System MG-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

Express Lavatory System MG-Series

AV60 Advocate Lavatory System AV-Series

AV90 Advocate Lavatory System AV-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

LVSD2 Verge Wash Basin LVS-Series

HL45, HL80 Thermostatic High-Low Valves

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Washfountain Application Guide

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation Instructions

LVSD2 Verge Wash Basin LVS-Series

AV60 Advocate Lavatory System AV-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LVQD1 Verge with WashBar Technology LVQ-Series

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

LD-5010 OmniDeck with WashBar 5000 Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Model Z Sundara Reef Triple Basin Hand Washing System

Installation Instructions

Installation Instructions

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Durability within reach

School Solutions Ideabook

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Installation Instructions

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

LA45 DISCONTINUED IMPORTANT!

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Installation Instructions

Installation Instructions

MERIDIAN MODEL# 3793

Bobrick - Washroom Accessories. Conversion Chart

TMV45 & TMV80 Standard Thermostatic Mixing Valves

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

LA60 DISCONTINUED IMPORTANT!

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Model Z Sundara Float Double Basin Hand Washing System

Installation Instructions OBSOLETE

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Moen Commercial Products Eco-Performance Product Guide

FL-3H, FL-3L Frequency Lavatory System FL-Series

LA90 DISCONTINUED IMPORTANT!

A. Section Joint Sealants: Seal fixtures to walls and floors.

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

PRO SERIES IMPORTANT SAFETY INFORMATION

Wall Mounted Shower Systems

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

FAUCET PARTS - EXPLODED VIEW Model: K-59

Installation Instructions

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

Transcription:

cupc Certified Available with Air, Infrared or TouchTime Available in a or 36" Bowl Size Standard and Juvenile Height Model with Infrared, TouchTime Pushbutton and Piezo or Air (hand) are ADA/TAS Compliant Factory Tested and Shipped Pre-assembled Vandal Resistant and Easy to Clean Specifications Size and Capacity Accommodates 5 users (36" models) or 8 users ( models) at a time, using less water, energy and space than lavs equipped with conventional faucets. The sectional sprayhead module is controlled by a push button, which actuates an air valve (hand or foot control models), or a solenoid valve (TouchTime models) or by an infrared sensor-actuated solenoid valve. Flow restrictor keeps flow rate constant at 0.5 GPM per station for all pressures. Operating range is 20-80 PSI. Construction Bowl and Pedestal All exposed materials are type 304 stainless steel polished to a #4 finish. Bowl, pedestal, access panels, frame, foot control housing; support tube and sprayhead are heavy gauge stainless steel. Exposed fittings are chrome plated. Vandal Resistance Bowl and support tube are an integrally welded assembly, with the support tube welded to extruded flange from bowl. Spray nozzles and push buttons/infrared sensors are secured to unit from inside the sprayhead module. Air valves/solenoid valves are safely concealed inside the washfountain. Access panels are removable. All supply and waste connections are concealed within the pedestal, which is secured to the floor with anchor bolts (supplied by others). Mounting Heights Sentry washfountains can be installed at standard or juvenile height. Floor-mounted models require mounting height selection. Wall-mounted units are simply installed at the desired height. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: Navigator thermostatic mixing valve, flexible stainless steel supply hoses and stop valves. Stop valves are 1/2" compression female. Activation Types Air - Hand Activation Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. Push button requires less than five pounds of pressure. Air - Hold open Foot Activation Each push button pneumatically actuates a hold-open air single temperature valve with slow closing upon release of foot pressure. Push button requires less than five pounds of pressure. Infrared Each of the stream formers is controlled by a separate slow-closing solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from one spray nozzle. Shut-off is automatic after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area that does not exceed the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: Solenoid 12VDC, 3/8" tube fitting. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Plug-In Adapter UL/CSA-listed 120VAC/12VDC plug-in adapter designed to plug into a standard GFCI protected electrical outlet. Location of plug-in adapter per local electrical code. Page 1 of 5 9/18/2017 SN2005, SN2008 TouchTime Each low-voltage pushbutton or piezo switch actuates a non-hold-open, slow closing antihammer solenoid valve that is timed from an electronic potted assembly. Each pushbutton activates one valve which, in turn, activates one station. TouchTime controls water flow at each station through the use of solid state, digital circuitry. Timing is factory set at a 15 second run time, but is field adjustable to pre-set time out periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Pushbutton requires less than five pounds of pressure. Code Compliance and Certifications cupc Certified Sentry Washfountains are Uniform Plumbing Code (cupc) certified through the International Association of Plumbing and Mechanical Officials (IAPMO). Barrier-Free (ADA Compliant) Models Only The standard or juvenile height Sentry Washfountain with Infrared, TouchTime or Air Metering hand activation is designed to comply with all ADA/TAS guidelines on reaches, clearances and operation. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Certified to NSF/ANSI 372 SN2008 (Air Valve Foot) SN2008 (Infrared) SN2005 (Infrared)

Models (Must select one) Model Size Stations Description SN2005 36" 5 Floor-Mounted SN2008 8 Floor-Mounted* Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with H O Centrally rising vent with Off-line vent with supplies from above Mounting Height Type (select one) STD Standard Pedestal Height JUV Juvenile Pedestal Height Activation Type (select one) AST4 Air - Hand Activation AST4-F Air - Hold Open Foot Activation** IRP Infrared Soap Dispenser Type (select one) LSD Four Integral Liquid Soap Dispensers NSD No Soap Dispenser Water Supply Type (select one) TMA Thermostatic Mixing Valve PBV Pressure Balance Mixing Valve Optional Selections Towel Dispenser Type CFTD (3) C-Fold, Multi-Fold Dispenser SFTD (3) Single-Fold Dispenser TTPA TTPB TL Shroud Type SH Stainless Steel Shroud (conceals overhead plumbing) NONE No Shroud TouchTime Pushbutton TouchTime Piezo Switch Tempered Line Supply NONE No Towel Dispenser * These models are ADA/TAS Compliant when mounted at standard or juvenile height dimensions with Infrared, TouchTime Pushbutton, TouchTime Peizo or Air (hand) Activation. ** Non-cancelable, not-returnable. Shroud is recommended for drain type B, H and O to conceal vent and/or supplies. Page 2 of 5 9/18/2017

Dimensions - Sentry Circular Washfountain SN2005, SN2008 Dimensions - Sentry 36" Circular Washfountain Infrared Activation Infrared Activation 40-1/* (1022) 15-1/2" (394) 40-1/* (1022) 6-1/2" (165) Air Valve - Hold Open Foot Activation 18-1/2" (470) Air Valve - Hold Open Foot Activation 9-1/2" (241) 10" (254) 7-1/ (184) 2-1/ (57) 3" (76) 3-1/ 39-1/2" (1003) Hand Activation (AST4 and TouchTime) 3" (76) Hand Activation (AST4 and TouchTime) 3-1/2" (89) 41"* (1041) 15-1/2" (394) 41"* (1041) 6-1/2" (165) 18-1/2" (470) Standard or Juvenile height models with Infrared, TouchTime or Air Metering Hand Activation are ADA/TAS compliant. Page 3 of 5 9/18/2017 * Subtract from this dimension for juvenile height. 9-1/2" (241)

Rough-In Dimensions for Drain and Supplies Type A Off-line vent with Type B Centrally rising vent with 3-1/ Tube Supplies Through Floor (Stub Up 2-1/2" (64) Above Floor) 1-3/16" (30) Drain Stub Up 3" (76) Above Floor 5" (127) Drain Stub Up 3" (76) Above Floor Tube Supplies from Above Must be Located on These Centers to Pass Through Washfountain Sprayhead * Remote mounting of transformers with 120VAC/12VDC electrical supply to washfountain is recommended. See local electrical codes before roughing in. (This conduit location is only a recommendation.) Type A Drain Supplies below Off-drain vent P-Trap furnished by others Type B Drain Supplies above Centrally-rising vent P-Trap furnished Rough-In Notes 1. Rough-In dimensions for this model accommodate standard height and juvenile height pedestals. 2. Maximum flow rate required to washfountain is 2.5 GPM for Model SN2005 and 4.0 GPM for Model SN2008. Size supply lines accordingly. 3. Unit with A drain and paper towel dispensers and/or a shroud, should use H drain Rough-Ins. Page 4 of 5 9/18/2017

Rough-In Dimensions for Drain and Supplies Type H Drain Centrally rising vent with Type O Drain Off-line vent with 3-1/ Tube Supplies Through Floor (Stub Up 2-1/2" (64) Above Floor) Conduit Location* (IR Only) 1-3/16" (30) Drain Stub Up 3" (76) Above Floor 5" (127) Drain Stub Up 3" (76) Above Floor Tube Supplies from Above Must Be Located on These Centers to Pass Through Washfountain Sprayhead * Remote mounting of transformers with 120VAC/12VDC electrical supply to washfountain is recommended. See local electrical codes before roughing in. (This conduit location is only a recommendation.) Type H Drain Supplies below Centrally-rising vent P-Trap furnished Type O Drain Supplies above Off-drain vent P-Trap furnished by others Rough-In Notes 1. Rough-In dimensions for this model accommodate standard height and juvenile height pedestals. 2. Maximum flow rate required to washfountain is 2.5 GPM for Model SN2005 or 4.0 GPM for Model SN2008. Size supply lines accordingly. 3. Unit with O drain and paper towel dispensers and/or a shroud, should use B drain Rough-Ins. Page 5 of 5 9/18/2017