CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Similar documents
Model 1750A/ 1770A Dehumidifier Installation Instructions

Model 1820 Dehumidifier

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Safety and Installation Instructions Model 1700

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Model 1730A Compact Dehumidifier Installation Instructions

Model 1870 & 1870W Dehumidifier Installation Instructions

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Installation, Safety & Maintenance Manual Model 1750A/1770A

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Model 1850F Dehumidifier Installation and Operating Manual

Model 1870F Dehumidifier Installation and Operating Manual

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Installation Instructions

Installation, Operation and Maintenance Instructions

Quest Dry 105, 155, and 205 Dual

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Quest 105, Dry155, and 205 Dual

Model 76 Dehumidifier Control Installation Instructions

Model 8120 and 8126 Safety & Installation Instructions

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Installation & Operation Instructions

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)

Desiccant Dehumidifier

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation & Operation Instructions

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Quest DRY quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest DRY 180:

Read and Save These Instructions

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Owner s Manual Ultimate 340

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

Installation Instructions

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Installation Instructions Owner s Manual

Read and Save These Instructions

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Quest Dry Quest Dry 105, 155, and 205

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

HVAC Equipment Access Equipment Location

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T20 Model

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

Installation Instructions INSTALLATION BY A HVAC PROFESSIONAL IS RECOMMENDED

Your safety and the safety of others are very important.

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

SAFETY AND INSTALLATION MANUAL MODEL 8100

INSTALLATION INSTRUCTIONS

T-Series Air Conditioner T53 Model

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Quest 215 DryDual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

PHOENIX 200 MAX. 1 Specifications. 2 Operation. Therma-Stor Products. Phoenix 200 Max Operation & Service Instructions

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

ELECTRONIC AIR CLEANER SAFETY AND INSTALLATION MANUAL MODEL 5000 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

Cooktop Chimney Ventilation Hoods

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

DEALER PARTS LIST DEHUMIDIFIERS. Model 1830/1850/1850F/1850W 17A 17B 17C

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTALLER S & OWNER S MANUAL

Installation Instructions

Installation Instructions

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLER S & OWNER S MANUAL

Installation Instructions

DRY 150 Quest PowerDry 1300

Owner s Manual Phoenix 250 MAX

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Owner s Manual HI-E Dry Vehere

INSTALLER S & OWNER S MANUAL

Installation Instructions

e Bath Fan with Light User s Guide

4201 Lien Rd. Madison, WI Owner s Manual Phoenix R250 LGR Dehumidifier. Installation, Operation & Service Instructions

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

Ultra-Aire 150H Whole House Ventilating Dehumidifier

Installation & Operation Instructions

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

IMPORTANT INSTRUCTIONS READ & SAVE

Safety, Installation, and Operation Manual

USER S INFORMATION MANUAL

Transcription:

DEHUMIDIFIERS 506451-01 04/2012 HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) FRONT VIEW (with alternate outlet location on top) BACK VIEW (with alternate outlet location on back) Dehumidistat Alternate Outlet Location Wire Access Door Filter Access Door Outlet Status LEDs Inlet On/Off Switch Drain Power Cord WARNING 1. Improper installation may cause property damage or injury. Installation, service, and maintenance must be performed by a qualified service technician. 2. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing. Leave power disconnected until installation/service is completed. 3. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling ductwork. 4. Dropping may cause personal injury or equipment damage. Use tools or two people to transport dehumidifier. 5. Do not remove the outlet screen. The screen is required to protect from moving parts and electrical components. CAUTION 1. Read all instructions before beginning installation. 2. Do not use in pool applications. Pool chemicals can damage the dehumidifier. 3. Do not use solvents or cleaners on or near the circuit board. Chemicals can damage circuit board components. 4. Wait 24 hours before running if the unit has not been shipped or stored in the upright position. 1

Table of Contents Overview... 2 Location Notes... 2 Specifications... 2 Dimensions and Clearances... 3 Unpacking and Contents... 3 Installation Components...................................... 4 Set-Up... 4 Mechanical Installation... 4 Wiring... 7 Start Up/System Checkout... 9 Service Parts List... 10 Sequence of Operation... 10 Troubleshooting Guide... 11 Wiring Schematic... 12 Overview The Whole Home Dehumidifier is designed to control humidity throughout the home. It can also be configured to control humidity in basements, crawl spaces and attics or other areas within the home (for more detail refer to the Mechanical Installation section). The dehumidifier can be wired to activate the HVAC blower during dehumidification, providing better circulation and balancing of indoor air conditions. The dehumidifier is equipped with a dehumidistat which continually measures the humidity of the air in which it is located and controls to the dryness level set on the dial. The dehumidistat can remain mounted on the unit or can be removed and mounted in a living space. DANGER Risk of Carbon Monoxide Poisoning and/or Explosion. Can cause injury or death. Negative pressure can cause back-drafting of combustion gases in other household appliances such as Gas Furnaces, Oil Furnaces, Hot Water Heaters, Wood Stoves, Fireplaces, etc. Combustion and flue gases from heating appliances must never be allowed to enter return air or living spaces. Seal all duct connections with joint tape and check for leaks. A balanced and sealed system will prevent negative pressure. Location Notes 1. Install Unit Indoors: Do not expose to elements. 2. Drain Accessibility: If a drain is not located in the installation area, a condensate pump may be required. 3. Power: Outlet within 8 feet of unit. Specifications IMPORTANT Installation must conform to all applicable codes. For the HCWH-065, a dedicated 15 Amp circuit is recommended but not required for proper operation of the dehumidifier. If a dedicated circuit is not available, use a lightly loaded circuit. Do not use an extension cord. For protection of the compressor, unit must be transported and installed in an upright position. If the unit was shipped or stored on its side, a 24 hour settling period is required before running the unit. Dimensions: Width: 12.5 cabinet, 13 with doors Height: 14.5 cabinet, 18.5 with leveling feet fully extended Length: 22 cabinet, 27 with collars Weight: 65 lbs. Capacity: 65 pints/day @ 150 cfm AHAM DH-1-2003 80 F, 60% RH conditions Efficiency: 1.8 Liters per kilowatt hour AHAM DH-1-2003 80 F, 60% RH conditions Power: 115VAC, 60 Hz, 8A Operating Current Unit equipped with 8 ft. grounded power cord 15 Amp circuit required Airflow: P ("w.c.) Airflow (cfm) 0 230 0.25 190 0.50 150 Inlet Air Operating Conditions: 60 F to 95 F, 30% RH to 99% RH Installation Conditions: 40 F to 140 F, 0% RH to 99% RH Evaporator Frost Sensor: 25 F +/- 5 F, circuit opens (cut-out) 55 F +/- 5 F, reset temperature (cut-in) Filter: MERV 8, washable All access panels/doors must be properly installed during system/unit operation. Never use access doors/panels as a return air inlet. Never connect a return or supply duct to other heating devices such as fireplaces or wood stoves. 2

Dimensions and Clearances Figure 1 8 in. (203) Round Collar Adjustable Legs 13-1/8 (333) ON/OFF Switch OUTLET AIR END Wiring Access 14-1/2 (368) 4 Max. (102) 2-1/2 (64) Power Cord Air Flow 22-1/8 (562) FRONT VIEW Filter Access (Front and Back) 2-1/2 (64) 8 in. (203) Round Collar 13-1/8 (333) 1-3/8 (35) INLET AIR END Humidity Control Drain 1 (25) 2-1/8 (54) clearance from leveling feet Support struts for suspending (bottom of unit) 12 in. (305) control access clearance, both ends SERVICE CLEARANCE 12 in. (305) filter/front panel service clearance (either side) TOP VIEW 4-1/2 filter access panel clearance (either side) (114) 90-1502 Unpacking and Contents Figure 2 Carton Opening & Contents Do not tip unit to remove from carton. 1. Open carton completely using cut line shown along bottom perimeter of carton. 2. Remove all cardboard inner pack (top edges and duct collars). 3. See Figure 2 for opening view and contents. a. Installation Manual b. Owner s Manual c. Dehumidistat (mounted to inlet panel) d. Bag with Dehumidistat Cover Plate, Screws (2), Anchors (2) e. Outlet with Back Flow Damper f. 8 ft. Grounded Power Cord g. Wiring Access Panel a b c d e f g 90-1464 3

Installation Components See specific set-up configurations for details. Required Drain Line Condensate Pan & Float Switch Set-Up Optional Wire (18-22 awg) 8 Duct (Flex or Rigid) Supply Collar The dehumidifier can be installed as shipped, with the supply collar on the outlet panel, or if space is restricted, the supply collar can be relocated to the top of the unit. Top Mount Supply Collar (Figure 3) 1. Remove the four screws securing the supply collar (with backflow damper) and screen to the outlet panel. 2. Remove the four screws securing the top-mounted outlet cover plate. 3. Attach screen and supply collar with damper to the top of the unit. 4. Attach outlet cover plate to the outlet panel. Figure 3 Top Mount Supply Collar NOTE: Leave room to make wire connections and view LED indicators. Supply collar mounted to top of unit LED indicators Dehumidistat Location The dehumidistat mounted to the dehumidifier can remain on the unit or be removed and mounted in the living space. Attic installations require that the dehumidistat be moved to the living space. Note: Any dry contact, normally open humidity control can be used as the controlling device for the dehumidifier. If using a normally open control other than the one provided, remove the dehumidistat as described in steps 1-6 in the WIRING, Dehumidistat Wall Mount Installation section. Follow steps 7-10 to wire an alternate control. If wiring to an icomfort System, remove the dehumidistat as described in steps 1-8 in the WIRING, Dehumidistat Wall Mount Installation section. See WIRING, icomfort System Installation section. Wall Mount Location Mount approximately 5 feet above the floor on an inside wall of the living space. Do not locate dehumidistat in the direct path of drafts from open doors and windows. Do not install where operation might be affected by lamps, outside sources of humidity (i.e. shower), fireplace, registers, or radiators. Mechanical Installation Drain Run vinyl or PVC tubing from the 3/4 drain outlet on the dehumidifier inlet to a floor drain. Make sure the drain line has a constant downward slope and is not kinked. Refer to local codes to determine if a p-trap is required. In attic installations a drain pan with float switch is required. See Float Switch section for wiring instructions. CAUTION An auxiliary drain pan with float switch is required in attic installations or in areas where water overflow may damage the structure. Outlet cover plate moved to outlet panel OUTLET VIEW 90-1425 4

Suspended Installation If hanging the unit, use 1/4 threaded rod and two unistruts to support the base just inside the leveling feet. It is recommended that vibration isolators be placed between the unistruts and dehumidifier base. See Figure 4. Do not position threaded rods over filter access doors. There must be a minimum clearance of 12 on one side of the unit to allow for removal of the filter. Figure 4 Suspended Installation FILTER ACCESS DOOR 4-1/2" Attic Installations The Preferred Installation ensures warm, dehumidified air is thoroughly mixed with HVAC system air before being discharged into the living space. If adequate space exists between the supply plenum and the first branch, allowing for proper mixing with the HVAC system air, the dehumidifier discharge may be ducted to the supply side. The Alternate Installation minimizes re-evaporation of moisture off the cooling coil. Attic installations require the dehumidifier to be installed in the supplied condensate pan with a field supplied float switch. Vibration isolators placed under the dehumidifier feet are recommended when the dehumidifier is installed on ceiling joists. THREADED ROD OUTLET THREADED ROD INLET Figure 5 Preferred Attic Installation PLENUM BOX OR Y-FITTING 6" MIN. 6 FT. MIN. AIR HANDLER VIBRATION ISOLATORS 2-1/8" CLEARANCE FOR LEVELING FEET FILTER UNISTRUT UNISTRUT 90-1427 90-1618-2 8" DIA. INSULATED DUCT BOTH SIDES CONDENSATE PAN Ducting The dehumidifier is supplied with two 8 round collars. An integral backflow damper is installed in the outlet collar. In a ducted installation, the dehumidifier pulls air from the living space or HVAC return duct and supplies the dehumidified air back to the HVAC return duct, and is the preferred installation. (See Figures 5 & 8). This installation must include wiring the dehumidifier to activate the HVAC blower during dehumidification. (See Wiring to HVAC System in WIRING section.) Activating the HVAC fan during dehumidification is recommended because it offers better circulation and balancing of indoor air conditions, and reduces moisture on the HVAC coil. Ducted Installation Move supply collar to the desired location, if necessary. (See Supply Collar in SET-UP section.) Use the least amount of ductwork possible. To ensure best performance, do not exceed a total of 50 feet of duct installed in accordance with SMACNA Standards. UL approved, 8 diameter, insulated duct is recommended for all connections. All joints and seams must be sealed. Figure 6 Alternate Attic Installation PLENUM BOX 0.4" w.c. MAX. 6" MIN. 6" MIN. AIR HANDLER 90-1618-4 24" MIN. 8" DIA. INSULATED DUCT BOTH SIDES Closet Installation Figure 7 Closet Installation FILTER CONDENSATE PAN PLENUM DEHUMIDIFIED AIR IS SUPPLIED DOWNSTREAM FROM A-COIL TO MINIMIZE EVAPORATION OFF A-COIL CAUTION Sharp edges hazard. Equipment sharp edges can cause injuries. Use protective gloves when grasping equipment edges. HVAC / FURNACE 2 FT INSULATED FLEX DUCT ON INLET TO REDUCE NOISE DEHUMIDIFIER 90-1618-7 CAUTION Ensure return grill in door is not obstructed so dehumidifier does not pull from HVAC system. 5

Basement Installations Figure 8 Preferred Basement Installation DEHUMIDIFIED AIR IS SUPPLIED DOWNSTREAM FROM A-COIL TO MINIMIZE EVAPORATION OFF A-COIL Stand Alone Installations In a free standing installation, the dehumidifier pulls air from the installed space and returns the dehumidified air back to that space. See Figure 10. Place unit in area with drain access and within 8 of an outlet. Unit can also be ducted to pull and return to a single living space. See Figure 11. Figure 10 Stand Alone, Non-Ducted HVAC / FURNACE AIR IS PULLED FROM RETURN DUCT DEHUMIDIFIER DEHUMIDIFIED AIR IS SUPPLIED TO INSTALLED SPACE 90-1618-18 AIR IS PULLED FROM INSTALLED SPACE Figure 9 Alternate Basement Installation DEHUMIDIFIER DEHUMIDIFIED AIR IS SUPPLIED DOWNSTREAM FROM A-COIL TO MINIMIZE EVAPORATION OFF A-COIL 90-1423 Figure 11 Stand Alone, Ducted HVAC / FURNACE AIR IS PULLED FROM RETURN DUCT LIVING SPACE DEHUMIDIFIER 90-1618-6 Basement Installation Note: The dehumidifier must be installed in an auxiliary drain pan with float switch. DEHUMIDIFIER 90-1423 6

Leveling Adjust feet as required for leveling and proper drainage (see Figure 12). Figure 12 Leveling Wiring 7/8" MINIMUM 4" MAXIMUM CONDENSATE PAN Wiring to HVAC System The dehumidifier can be wired to activate the HVAC blower during dehumidification. This is recommended because it offers better circulation and balancing of the indoor air conditions, and reduces moisture on the HVAC coil. Note: Running the HVAC blower during dehumidification does not affect moisture removal efficiency. If the unit is not wired to the HVAC system, air is pulled through the unit, dehumidified, and circulated solely by the dehumidifier blower. 90-1498 HVAC Wiring Instructions 1. Disconnect power to the HVAC system using disconnect switch or fuse/breaker. 2. Unplug the dehumidifier. 3. Remove wiring access panel on the dehumidifier outlet panel. 4. Run a 3-wire cable from the dehumidifier to the furnace/air handler. 5. The G-STAT, R-HVAC, & G-HVAC terminal can be removed from the circuit board for ease of wiring. Unplug the terminal and make the connection shown in Figure 13. 6. Plug terminals back into circuit board. 7. Replace the wiring access panel when wiring is complete. Dehumidistat Wall Mount Installation (Figure 14) 1. Gently pull knob (A) from the dehumidistat cover (B). The cover is held in place by snap clips. Remove the cover by pulling carefully. Do not touch the sensing element on the dehumidistat (C). 2. Remove 4 screws in base plate (D) and save for attaching the provided cover plate in place of the dehumidistat. 3. Pull dehumidistat off unit until 4-6 of wire is outside of unit. 4. Cut wires and use tape to secure leads to inside of unit, preventing contact with blower. 5. Remove the gasket from the base plate. This will be used with the insulated cover plate installed in the next step. 6. Using the screws removed in Step 2, install the provided insulated cover plate with gasket over the dehumidistat opening on the unit. 7. Remove the wiring access panel on unit outlet panel. 8. Unplug the REMOTE terminals from the circuit board, remove the two wires and cut off bare leads. Once cut, the wires may remain in the unit. 9. Run a 2-wire cable (18-22AWG) from the dehumidifier to the wall mount location. 10. Connect cable at the dehumidifier to the REMOTE terminals. Plug terminals into the circuit board and replace wiring access panel. See Figure 15. 11. Use the dehumidistat base as a template to mark mounting holes and wire access location on the wall. 12. Drill two 3/16 holes at mounting locations and a 3/8 hole at desired wire access location. 13. Pull 2-wire cable from the dehumidifier through the wire access opening in the wall. 14. Strip wire ends coming from the dehumidistat and dehumidifier and connect with small, field supplied wire nuts. 15. Push excess wire and wire nuts through the access hole in the wall. Use the supplied screws (E) and wall anchors (F) to attach the base plate (with dehumidistat) to the wall using the top centered hole and bottom centered slot. 16. Reassemble dehumidistat cover by snapping in place on base plate and press on knob. icomfort System Installation A Lennox control with a dehumidifier connection can be used as a dehumidifier control with the addition of an external relay. For operation with a Lennox control, make the connections shown in Figure 16. Figure 13 Dehumidifier/HVAC Unit Wiring Instructions THERMOSTAT R C G W Y HVAC EQUIPMENT R C G W Y REMOVABLE DEHUMIDIFIER CIRCUIT BOARD TERMINALS G STAT R HVAC G HVAC 90-1424 7

Figure 14 Wall Mount ANCHOR F (x2) SCREW E (x2) BASE PLATE D DEHUMIDISTAT C COVER B KNOB A BASE PLATE D DRILL 3/16 DIA HOLES FOR MOUNTING CUT WIRES 4-6 LENGTH 90-1466 Figure 15 Dehumidistat to Dehumidifier Wiring 90-1465 Figure 16 Lennox Control to Dehumidifier Wiring NOTE: Normally closed controllers are not recommended. If the controller loses power, is removed from the wall, or if the batteries fail, the dehumidifier would revert to continuous operation, which has the potential of leading to a water leak. LENNOX icomfort CONTROLLER R I+ I- I- C C icomfort ENABLED HVAC UNIT R R I+ G DH C EXTERNAL RELAY REMOVABLE DEHUMIDIFIER CIRCUIT BOARD TERMINALS FLOAT SWITCH REMOTE G-STAT R-HVAC G-HVAC 90-1465 8

Float Switch If the dehumidifier is installed in an attic or an area requiring leak protection, the unit must be placed in a drain pan with a normally closed condensate overflow safety switch (float switch). The float switch should be wired to the FLOAT SWITCH terminals on the circuit board on the outlet panel (See Figure 17). The compressor is disabled when the float switch is open. Wiring Instructions 1. Remove wiring access panel on the outlet panel. 2. Unplug the FLOAT SWITCH terminals and remove the jumper. 3. Run a 2-wire cable from the dehumidifier to the float switch. 4. Wire float switch to FLOAT SWITCH terminals and plug the terminals back into circuit board (Figure 17). 5. Replace the wiring access panel. Figure 17 Wiring to Float Switch LOW VOLTAGE NORMALLY CLOSED FLOAT SWITCH FLOAT SWITCH 90-1429 Start Up/System Checkout 1. Check the wiring and restore power to the HVAC equipment (if applicable). 2. Plug in the dehumidifier and turn on/off switch ON. 3. Check LED indicators located below the wiring access panel. Verify the green LED is on. The green LED is on when power is applied to the system. See Figure 3. 4. Rotate the dehumidistat knob fully clockwise to ON position. 5. If set-up is correct, the dehumidifier blower, and HVAC fan (if applicable) will turn on. The compressor will turn on after the dehumidifier blower has run for 3 minutes. Refer to the TROUBLESHOOTING GUIDE if the dehumidifier blower and/or compressor do not activate. 6. Check LED indicators. Green should remain on. If Red LED is on, refer to the TROUBLESHOOTING GUIDE. The red LED turns on when a fault condition is active. Possible fault conditions include open float switch or open high temperature switch. 7. After verifying operation, rotate the dehumidistat knob counterclockwise to set the dehumidifier to the desired dryness level. Start at 2-1/2 as the initial setpoint for economy, property protection and upper end of comfort range. Change dryness level up or down as desired for comfort or economy. This will vary depending on location and conditions. Moving the knob toward MORE DRY will increase the amount of time the dehumidifier runs, making conditions dryer. Moving the knob toward LESS DRY reduces the amount of time the dehumidifier runs, allowing for higher humidity levels. See Figure 18 for knob setpoint. Figure 18 Dehumidistat Setpoints 90-1490 9

Service Parts List Sequence of Operation Catalog Number Y3032 Y5028 Y5029 Y5030 Y5031 Y5032 Y5033 Y5034 Y5035 Y3066 Y3033 Y3064 Y3065 Y3196 Service Parts List Part Description Air Filter Backflow Damper Impeller with Bracket Leveling Foot 55 MF Capacitor for Compressor Control PCB Assembly High Temperature Cutout Switch Low Temperature Cutout Switch Outlet Screen Dehumidistat Control Assembly Filter Access Door Assembly Dehumidistat Hole Cover Outlet Cover Plate Condensate Pan The dehumidistat continually measures the humidity of the air in which it is located and controls to the dryness level set on the dial. Humidity level rises above the dial setting on the dehumidistat. Dehumidifier blower turns on. DEH amber LED on the power board (not visible unless dehumidifier cover is removed) will illuminate. If wired to HVAC system, HVAC system blower and HVAC amber LED (not visible unless dehumidifier cover is removed) will turn on and illuminate. After 3 minutes of blower operation, the dehumidifier compressor and COMPR amber LED (not visible unless dehumidifier cover is removed) will turn on and illuminate. Note: To prevent shortcycling, the dehumidifier compressor will turn on 3 minutes after the blower. Humidity level falls below the dial setting on the dehumidistat. Dehumidifier compressor turns off. Dehumidifier blower turns off. If wired to HVAC system, HVAC system blower turns off, unless the system thermostat keeps it running. The dehumidifier is equipped with an automatic defrost feature. When the evaporator coil temperature drops below the cut-out point of the frost sensor, the dehumidifier begins the defrost cycle and the dehumidistat will turn off the compressor and the blower will continue to run. The compressor will remain off until the evaporator coil temperature rises above the cut-in point of the frost sensor. 10

Troubleshooting Guide Symptom Red LED On Blower & compressor not running. Red LED On Blower is on but compressor not running. Dehumidifier blower is running but little or no airflow. Blower is running but compressor is not. Dehumidifier is not draining properly. The dehumidifier does not run. Dehumidifier is loud when operating. Dehumidifier is producing hot air. Possible Reason/Troubleshooting Procedure Open Float Switch If float switch not installed, confirm jumper installed at FLOAT SWITCH terminals. If float switch installed, confirm switch is not open. Clear obstruction in drain pan/tubing. High System Pressure/High Discharge Line Temperature Due to Lack of Airflow or Excessive Inlet Temperature Check dehumidifier air filter and wash or replace. Check for blocked ductwork and clear. Pressure Drop Across Dehumidifier is Higher than 0.8 w.c. Check dehumidifier air filter and wash or replace. Check for blocked ductwork and clear. Check if back flow damper is blocked or stuck and remove obstruction. Coil Frosting Lack of or reduced airflow, check/clean filter. Inlet air conditions too low (below 60 F), turn down dryness setting. Blower 3 Minute Minimum ON Time Wait 3 minutes. Compressor will not start until blower has run for 3 minutes. Incorrect Drain Installation Check drain line for continuous downward slope. Verify there are no kinks, traps or debris in drain line. If drain trap installed, confirm trap is properly installed, clear and primed. Unit is not level, adjust feet. No Power to Unit Green LED Off (15 amp circuit required). Check that the power switch on the dehumidifier is ON. Check if circuit breaker has tripped. Dehumidistat is OFF Turn on dehumidistat. Fan Noise If inlet is not ducted to HVAC return, install approximately 2 of 8 flex duct on inlet collar. Vibration Install vibration isolators under dehumidifier feet. The dehumidifier normally produces heated, dry air. Better mixing with the HVAC system air is needed. Change ducting to allow for maximum mixing. See Mechanical Installation section. Wire dehumidifier to the HVAC system. 11

Wiring Schematic RUN CAPACITOR FOR COMPRESSOR HIGH TEMP CUTOUT SWITCH LOW TEMP CUTOUT SWITCH CONTROL PCB ASSY COMPRESSOR C S ORG RED LEDS HVAC DEH COMPR R BRN BLU BLK YEL BRN CIRCUIT BOARD MANUAL DEHUMIDISTAT 24VAC TRANSFORMER BLOWER GRN / YEL BRN POWER CORD GRN WHT BLK BLU BLU WHT 10uF BLK 10 MFD CAPACITOR ON / OFF SWITCH BLK 90-1765 10009811 4.12 B2205710A 12