Ventilation Solutions IAQ Canada

Similar documents
50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

Ventilation Solutions IAQ Canada

IAQ VENTILATION SOLUTIONS

IAQ VENTILATION SOLUTIONS

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Product Catalog Commercial Solutions US Edition

Product Catalog Commercial Solutions US Edition

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

Light commercial models

Indoor Air Quality Product Brochure.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Indoor Air Quality Product Brochure.

Residential Heat & Energy Recovery

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

SER150. Installation Manual. Energy Recovery Ventilators

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Put the V back in HVAC

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Heat Recovery Ventilators (HRVs) Flexibility. in Perfect Form. Improving indoor air quality through better ventilation

BETTER AIR. BETTER LIFE.

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

TR Series - The Ultimate ERV

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

healthy comfort Indoor Air Quality Solutions

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

BALANCED VENTILATION SYSTEMS

PHRV(R) Series. Heat Recovery Ventilator PHRV 140 PHRV 150 PHRV 200 PHRVR 155 PHRVR 160 PHRVR 205 PHRVR 210 PHRVR 305

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Clean Air Solutions. A Complete Family of Indoor Air Quality Products, for the Protection of your Home and your Family.

Building Science Basics

Tech to Tech May 07 HRV s & ERV s

healthy comfort Indoor Air Quality Solutions

Outside Air Requirements... SOLVED!

SHR & VHR Models. SHR & VHR Series. Installation Manual. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Heat or Energy Recovery Ventilation System

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

VHR SERIES VHR 704. Installation Manual. Heat Recovery Ventilator INSTALLATION, OPERATION AND MAINTENANCE MANUAL

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

Energy Recovery Ventilators

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

SER Models. SER Series Energy Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

READ AND SAVE THESE INSTRUCTIONS

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

The best way to enhance indoor air quality

HEALTH. Particles. Chemicals

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Fresh Air Solutions Whole-Home Ventilation

SAFETY AND INSTALLATION MANUAL MODEL 8100

HEAT RECOVERY VENTILATOR

Ventilation and Indoor Air Quality

Ventilation for New Low-Rise Residential Buildings July 20, 2015

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

VENTILATORS VH30100 COMPACT HEAT RECOVERY VENTILATOR VE30100 COMPACT ENERGY RECOVERY VENTILATOR. Installation and Operation Manual.

A whole lot of fresh.

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted.

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

OPERATIONS & MAINTENANCE MANUAL RESIDENTIAL HEAT & ENERGY RECOVERY VENTILATORS TO BE COMPLETED BY CONTRACTOR AFTER INSTALLATION

PW 150 / PW 100. Heat Recovery Ventilator IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT INSTALLATION, OPERATION AND MAINTENANCE MANUAL 1

ENERGY RECOVERY VENTILATOR

Condensation on Your Windows?

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

Heat Recovery Ventilators models:

INDOOR AIR QUALITY KITS AND ACCESSORIES /12 Supersedes 05/12

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL HEAT & ENERGY RECOVERY VENTILATORS FOR MODELS: H/E80 H/E130

INDOOR AIR QUALITY KITS AND ACCESSORIES /2014. Supersedes 06/2014

HEALTH. Particles. Chemicals

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

INDOOR AIR QUALITY PRODUCT LINE CARD 10.18

Choosing an Air Cleaner

Heat & Energy RECOVERY VENTILATORS

Residential Balanced Ventilation Systems

INSTALLATION AND OPERATION INSTRUCTIONS

Home air-improvement options to suit your needs

10-year industry best core warranty. 5-year warranty on balance of unit.

Clean air is a human right

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

HEPA Filtration. HEPA Series. Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Ventilation has never been more important

Desiccant Dehumidifier

Temperature Relative Humidity

ClalrlTech INNOVATIONS. ClairiTech. 120 Hybrid. Installation and Operations Manual Model: H-120 Rev: 1.4

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

WHOLE-HOUSE VENTILATION SYSTEMS

Exhaust Makeup Air System What goes out, must come in

Installation Information

Transcription:

Ventilation Solutions IAQ Canada

2 IAQ Canada Indoor Air Quality Keep your family safe What s All The Talk About Indoor Air Quality? What The Experts Say: You ve heard it on TV and read about it in magazines. The news is everywhere... the air inside your home can be up to five times more polluted than the air outside. Since the 1970s, when we started building tighter energy-efficient homes, the level of indoor air pollutants has steadily increased. Why? Contaminated air which once escaped through cracks around windows and doors is now trapped inside with you and your family. In a survey conducted by the American Lung Association 50% of the people surveyed were not aware that poor indoor air quality is one of the top five most urgent environmental risks to public health. - American Lung Association Proper ventilation will always make a positive contribution to indoor air quality aiding in the control of contaminants including moisture and mold. - Home Ventilating Institute Indoor air quality is important to human health because we spend over 80% of our time indoors. Tight insulation, too much humidity and other factors can lead to unhealthy air in your home or workplace, causing a number of health problems. - Health Canada Improving ventilation and airflow is basic to air quality, especially if your home is new or recently remodeled. - Mayo Clinic

IAQ Canada 3 Safeguard Your Home Three easy steps Your home should be safe and comforting, not a place that makes you sick. People can have air quality problems in any kind of home, new or old. The good news is that that you can do something right now to improve your home s air quality. The Lung Association of Canada. Asthma affects over 20 million people in North America including 6.3 million children. Step 1 Toxic Clean Up Step 2 Better Ventilation Step 3 Clean and Filter The Air Once you become aware of the possible pollutants in your home, you can take the first step to improving the quality of the air you breathe just by eliminating many of the irritants. Different types of pollutants that might be found in your home include. Biological Contaminants Chemical Contaminants Combustion Sources Building Materials Don t smoke indoors Limit chemicals used for cleaning purposes Wash bedding/linens in hot water to kill dust mites Keep pets outside Improve indoor air quality with better ventilation in the areas of the home where moisture, smoke or steam occur. Bathrooms Kitchens Laundry Rooms with Fireplaces Today s energy efficient construction methods make homes so tight that mechanical ventilation is needed to remove contaminants which cause mold, mildew or poor air quality. An energy saving Fantech Heat Recovery Ventilator is an ideal choice to bring a continuous supply of fresh, filtered air into your home while expelling stale air. The third step to better indoor air quality is to filter the air. Fantech s Whole House HEPA Filtration unit is one way you can do just that. This small, compact unit is designed to clean the total volume of air in an average size house once an hour. Mold spores, pet dander, cooking odors, dust, dust mites and their by-products are all captured in a series of three filters. Fantech s HEPA Filtration System easily installs on the existing ductwork of your forced air furnace/ air handler or can be used as an independent system mounted in the attic, crawl space or closet.

4 IAQ Canada Heat Recovery Ventilators The basic Did You Know? What are HRVs Benefits of a Heat Recovery Ventilator Studies have found that simple things like mopping the kitchen floor, taking a shower, doing the laundry or just breathing can generate enough moisture in your home to raise the relative humidity to an unhealthy level. Increased humidity and moisture inside your home can lead to severe structural damage that you can t see until it s too late. Increased moisture levels can also dramatically affect your family s health due to increased mold and mildew. To better understand these products and their function, here are a few things to remember. Heat Recovery Ventilators are recommended for colder areas of the country that have longer heating seasons. Heat Recovery Ventilators are complete whole house ventilation systems that incorporate a supply motor and an exhaust motor in one unit. The supply motor draws fresh air in from the outside and the exhaust motor pushes stale contaminated air out. The two air steams are separated by a heat recovery core which tempers the air making it the most comfortable solution for a healthy indoor environment. Brings a continuous supply of fresh, filtered outside air into the home Exhausts environmental contaminants for improved indoor air quality Saves energy by recovering heat from exhaust air in the winter Cools incoming air in the summer when the house air is cooler than the outdoor air Controls excess humidity in cooler seasons by introducing outdoor air into the house For information on how these units can help you save energy and lower heating or cooling costs, read How Do They Work?.

IAQ Canada 5 Heat Recovery Ventilators Features Electrostatic Filters Fully Insulated Cabinet Motor How Do They Work? Control Board Aluminum Core Motor Features in all Models Stale air to outside Fresh air from outside Stale air from inside Fresh air to inside An HRV is designed to bring a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air. HRVs use what is called a heat recovery core. This special aluminum core transfers heat from the exhaust air stream to the incoming air stream. Fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs. Fantech HRVs are equipped with automatic defrost mechanisms so even if you live in the cold climates you can use your HRV all year long. Heat Recovery Ventilators : Defrost Methods Defrost by air recirculation for a higher efficiency at low temperature. Doesn t cause depressurization of the building, the unit uses indoor air to defrost the core and prevent freezing. Defrost by exhaust takes the air from the inside to defrost the core and expels indoor air for a very short period to a predetermined temperature to prevent freezing of the core. This method never interrupts ventilation since the exhaust fan remains on while the supply fan is momentarily shut-off. Aluminum Core The high quality aluminum core used in Fantech HRVs offers efficient heat transfer, improved defrost characteristics and ease of maintenance. Lifetime warranty. Washable Electrostatic Filters The filters don t need to be replaced. Fully Insulated Cabinet Powder-coated galvanized steel (20-24 gauge) with foil-faced insulation Electronic Control Boards Superior microprocessor technology efficiently controls operation of the unit while making it easy to connect to existing HVAC equipment and convenient wall controls. Built in surge protection for long life. Motors The unique design of Fantech s External Rotor Motors significantly extends life expectancy of the motors. Typical motor life could be is in excess of 100,000 hours. Permanently lubricated bearings guarantee maintenance-free operation. Internal thermal overload protection is built in. Suitable for continuous or intermittent duty. 7 year (limited) warranties. Superior Warranties 7 Year (Limited) Motor Warranty Lifetime (Limited) Warranty on Aluminum Core 5 Years (Limited) Warranty on other Component Parts

6 IAQ Canada The Right Unit: How many room does your home have? Use the table below to determine your minimum ventilation needs. If you choose to use the HRV to provide the required supplemental exhaust for bathrooms or the kitchen, refer to the building code to determine the additional ventilation capacity required. Number of bedrooms in dwelling unit Continuous ventilation capacity Minimum Maximum L/s cfm L/s cfm 1 16 34 24 51 2 18 38 28 59 3 22 47 32 68 4 26 55 38 81 5 30 64 45 95 More than 5 System must comply with Clause 9.32.1.3.1(1)(a) * Table 9.32.3.3.A., National Building Code of Canada. Installation Options HRVs can be installed as stand-alone systems that use independent ductwork or they can be connected to the existing duct of your forced air heating or cooling system. Fully dedicated system Provides the best fresh air distribution in the house; lowest operation cost since the furnace/air handler is not needed. Partially dedicated system Conditions the fresh air from the furnace then distributes it throughout the house. Simplified installation Least expensive installation type. Exhaust air from baths Fresh air to bedrooms & living room Bath Kitchen Bedrooms Living room Fresh air to bedrooms & living room via furnace duct Bath Kitchen Bedrooms Living room Fresh air to bedrooms & living room via furnace duct Bath Kitchen Bedrooms Living room Exhaust air from baths & kitchen Exhaust air from baths & kitchen Exhaust air from house via furnace duct

IAQ Canada 7 Fantech s Residential HRVs Specifications FLEX 100H 20-49 L/s @ 100 Pa (47-105 cfm @ 0.4 in wg. ) Small Compact Size Includes easy-mount wall bracket TURBO Mode option increases airflow up to 50% 5 oval ports with integrated balancing damper and balancing port Quick Connect Recirculation defrost ENERGY STAR qualified VHR series VHR 70R 9-30 L/s @ 75 Pa (20-64 cfm @ 0.3 in wg.) Small compact size Includes easy-mount wall bracket 5 oval ports with integrated balancing damper and balancing port Quick Connect Recirculation defrost ENERGY STAR qualified VHR 704 9-32 L/s @ 75 Pa (20-67 cfm @ 0.3 in wg.) Small compact size Includes easy-mount wall bracket 4 round ports Exhaust defrost VHR 100R 20-49 L/s @ 100 Pa (47-105 cfm @ 0.4 in wg. ) Small Compact Size Includes easy-mount wall bracket 5 oval ports with integrated balancing damper and balancing port Quick Connect Recirculation defrost ENERGY STAR qualified VHR 150R 29-74 L/s @ 100 Pa (62-157 cfm @ 0.4 in wg) 6 oval ports with integrated balancing damper and balancing port Quick Connect Recirculation defrost ENERGY STAR qualified VHR 2005R 28-95 L/s @ 100 Pa (60-201 cfm @ 0.4 in wg) 6 round ports Recirculation defrost VHR 150 24-75 L/s @ 100 Pa (50-159 cfm @ 0.4 in wg.) 6 oval ports with integrated balancing damper and balancing port Quick Connect Exhaust defrost VHR 2004 28-95 L/s @ 100 Pa (60-201 cfm @ 0.4 in wg.) 6 round ports Exhaust defrost

8 IAQ Canada Fantech s Residential HRVs Specifications SHR series SHR 1505R 24-71 L/s @ 100 Pa (50-152 cfm @ 0.4 in wg) Recirculation defrost, 5 th port SHR 2005R 28-95 L/s @ 100 Pa (60-201 cfm @ 0.4 in wg) Recirculation defrost, 5 th port SHR 3005R 31-109 L/s @ 100 pa (65-231 cfm @ 0.4 in wg ) Serie s most energy efficient 2 Heat recovery cores Recirculation defrost, 5 th port SHR 1504 24-70 L/s @ 100 Pa (50-149 cfm @ 0.4 in wg) Exhaust defrost SHR 2004 28-95 L/s @ 100 Pa (60-201 cfm @ 0.4 in wg) Exhaust defrost SHR 3205RD 31-126 L/s @ 100 Pa (65-267 cfm @ 0.4 in wg) 2 access doors Recirculation defrost, 5 th port Selection Charts Heat recovery ventilators Model Port location Port Size in Average Airflow Range L/s @ 100 Pa CFM @ 0.4 wg Defrost Mode Application Closet Wall Suspended Installation type Dedicated Partially dedicated Simplified Effectiveness (ASE) at 0oC ENERGY STAR Qualified Products FLEX100H Vertical 5 oval 20-49 47-105 Recirculation 80 VHR 704 Vertical 4 round 9-32* 20-67* Exhaust 67 VHR 70R Vertical 5 oval 9-30* 20-64* Recirculation 69 VHR 100R Vertical 5 oval 20-49 47-105 Recirculation 80 VHR 150 Vertical 6 oval 24-75 50-159 Exhaust 79 VHR 150R Vertical 6 oval 29-74 62-157 Recirculation 79 VHR 2004 Vertical 6 round 20-95 60-201 Exhaust 77 VHR 2005R Vertical 6 round 28-95 60-201 Recirculation 77 SHR 1504 Horizontal 6 round 24-70 50-159 Exhaust 73 SHR 1505R Horizontal 6 round 24-71 62-157 Recirculation 76 SHR 2004 Horizontal 6 round 28-95 60-201 Exhaust 77 SHR 2005R Horizontal 6 round 28-95 60-201 Recirculation 77 SHR 3005R Horizontal 6 round 31-109 65-231 Recirculation 91 SHR 3205RD Horizontal 8 round 31-126 65-267 Recirculation 77 Note: Before choosing a unit, always check local code requirements. Unit`s dimensions are available on the spec sheets. * Average airflow measurements @ 0.3 in.wg (75 Pa)

IAQ Canada 9 Filtration Whole house HEPA Fantech provides an added solution for better indoor air quality with the Whole House HEPA filtration unit. This small, compact unit installs on the existing ductwork of your furnace/air handler or can be used as an independent system mounted in the attic, crawl space or closet. It is designed to clean and filter the total volume of air in an average 2200 sq. ft. (204 m 2 ) house once an hour. Larger homes will take slightly longer for complete air change. Mold spores, pet dander, cooking odors, dusts, dust mites and their by-products are all captured in a series of three filters. The prefilter collects the largest particles while the carbom filter absorbs odors. The third filter is a true, certified HEPA filter which collects particles down to 0.3 microns. Three models to choose from CM3000 Collar mount model comes with for collars, two pieces of UL Listed 8 flex duct and hanging chains. CM3000I Insulated unit is used in unconditioned spaces such as attics and garages. Insulated outer shell prevents condensation problems. Kit includes hanging chains DM3000P Duct mount model features integrated airflow sensor switch which energizes the unit any time furnace/air handler operates. Designed with a backplate that allows direct connection of the unit to air handler or furnace.

10 IAQ Canada Convenient Low Voltage Wall Controls ECO-Touch Programmable Touch Screen Wall Control Our most complete, yet easy to use control system Sleek design with backlight touchscreen LCD ECO mode selects the best operating mode and speed for the season, minimizing energy use associated with ventilation Set preferred indoor relative humidity range and ventilation mode for day and night conditions No battery to replace, all programmed settings are retained during power outage Maintenance reminder indicator Error code messages reduce troubleshooting time Use in one central location RTS2 Pushbutton Timer 20-Minute Timer with LED Light Boosts system to high speed with the touch of a button Up to five can be used with one system Use in bathrooms, kitchens, laundry *RTS3 Pushbutton Timer 20-40-60 Min. Boost Timer Press button once to energize system to high speed for 20 minutes Press button twice and the unit will run for 40 minutes on high speed. MDEH1 Dehumidistat Press button three times for 60 minutes of high speed Up to five can be used with one system Rotary Dial Dehumidistat Just turn dial to set desired humidity level Multiple units can be used Install in bathrooms, kitchen, laundry Dehumidifies when air outside is dryer than air inside EDF7 Electronic Multifunction Dehumidistat Mode button provides 3 modes of operations: Ventilation Recircualtion and Standby User selected fan speed: Reduced, Medium, Normal and 20 minutes per hour AUTO setting allows the homeowner to deactivate the dehumidistat When the humidity exceeds the desired setpoint, the ventilation system operates at Normal speed Once the desired humidity level is achieved, your ventilation system resumes to its previous mode of operation EDF1/R Triple Function Wall Control Press button once for continuous low speed Press button twice and the unit will cycle 20 minutes ON/40 minutes OFF and repeat EDF1R: Press the button a third time and the system will run recirculation on high speed EDF1: Press the button a third time and the system will run continuously on high speed Use in one central location *RTS5 Pushbutton Timer 20-40-60 Min. Boost Timer Press button once to energize system to high speed for 20 minutes Press button twice and the unit will run for 40 minutes on high speed. *MDEH2 Dehumidistat Press button three times for 60 minutes of high speed Up to five can be used with one system Dial lights up when dehumidistat turns unit to high speed Use one per system On/off slider switch Dehumidifies when air outside is dryer than air inside. * Verify compatibility

IAQ Canada 11 Selection Charts Wall controls Heat recovery ventilators ECO-Touch EDF7 EDF1R EDF1 RTS2 RTS3 RTS5 MDEH1 MDEH2 FLEX100H VHR 704 VHR 70R VHR 100R VHR150 VHR 150R VHR 2004 VHR 2005R SHR 1504 SHR 1505R SHR 2004 SHR 2005R SHR 3005R SHR 3205R Accessories MGE/MGS Metal Exhaust/Supply Grilles CG Contour Grille FB6 Inline Filtration Box This diffuser made of painted steel has a device for generating a distribution of air at 180 and an adjustable opening. Grilles are manufactured of flame retardand, polypropylene that resist yellowing. White matte finish can be painted to match walls or ceiling. Filter box equipped with a MERV12 filter. The casing is made of painted galvanized steel and can be connected directly to the duct.

Customer Support 800.565.3548 CANADAsupport@fantech.net Send Orders: CANADAorders@fantech.net 877.747.8116 Systemair Inc December, 2014 413885 Keep yourself updated on all news and new products by following us on fantech.net Fantech reserves the right to modify at any time and without notice any or all of its products features, designs, components and specifications to maintain their technological leadership position.