heatersteam unprecedented precision and reliability

Similar documents
heatersteam unprecedented precision and reliability

Humidity matters! CAREL solutions for your humidification needs. carel.com. air humidification systems. isothermal and adiabathic humidification

mc multizone simple and robust, ideal for large industrial environments

heatersteam titanium Climate Platform Climate Business Unit

Water atomiser through compressed air

pchrono the lighting management solution carel.com

High efficiency waterloop system, now refrigerant neutral

E X V sistema Precision mechanics, powerful control. carel.com. connectivity, monitoring and remote managem,ent systems

air humidification systems adiabatic humidification humifog multizone high pressure atomised water humidifier carel.com

High efficiency waterloop system. The neutral refrigerant solution for high efficiency. carel.com

Integrated CO 2 system with pumping unit and direct expansion Energy saving and reduced environmental impact

CAREL heatersteam Electric Element Steam Humidifiers

humifog Pressurized water humidifi ers

High efficiency waterloop system

Connectivity, a guide for supervision

retail sistema as an energy saving solution

The integral solution for. Air Handling Units. Technology & Evolution

Condair Mk5. Getting rid of scale. The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy

humidifi cation for life

High pressure water atomizing humidifier 30.3 (770) Energy saving! 32 (810) 1.5 (40) max 1 (24) 14 (355) 1 (22,6) 1.5 (38) .

Key benefits. Why Condair CP3?

onshow Discover our world, experience our solutions, take part of it! Connected Efficiency

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

Temperature & Humidity Control Systems for the Wine Industry

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

LE Series. Electrode Steam Humidifiers

humisonic direct Climate Business Unit Adiabatic System Platform

Solutions for the use of CO2 in commercial refrigeration

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

STEAM TO STEAM HUMIDIFIER

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

RAYCHEM NGC-30 COMPONENTS

onshow The world of cooling, our natural environment Experience our passion for a greener future

I/O logger box. User manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT!

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

STEAM TO STEAM HUMIDIFIER

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

CONDAIR ESCO. Live steam humidifier with 100% steam tight rotary valve. Humidification and Evaporative Cooling

RESISTIVE STEAM HUMIDIFIER

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

NH Series Electric Steam Humidifiers

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

Chilled Water Precision Air Conditioner for Critical Application

a glance!

Process Alarm Solutions

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

NH-EL. The evolution of the industry s most trusted electrode steam humidifier NH SERIES. humidity.com

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

RACK MONITORING SYSTEM RAMOS Ultra

Reproducible Climate...

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Precision air conditioners with inverter technology for stable room conditions

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

Thermo Scientific VersaCool Refrigerated Circulating Bath. experience the benefits. of going headless

The SKD direct steam injection system uses low pressure steam from an in-house boiler to humidify the air.

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

Flexible & Innovative. Cooling Solutions

Compact Ultra Low Temperature Chamber

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

Customers. The core of our innovation. Feeding&Conveying. Drying Dosing Temperature Control Refrigeration Granulation

SHAKING WATER BATHS ENGLISH

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

Benchtop Test Chambers. Temperature and Humidity

Plant growth chambers

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

ALL PRODUCTS BROCHURE

Leading Humidification Innovation... Once Again. Nortec s GS Series Condensing High Efficiency. Humidification and Evaporative Cooling CONDAIR GROUP

Custom modular design to fit any application

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

SKG Advantages. Typical Applications. Typical Installation

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

"ER" Series Electric Humidifier

ALL PRODUCTS BROCHURE

Vertical self-contained air conditioner

Contamination Control for Electronic and Semiconductor Applications

green&clean multi-rinse Rack Type, Energy Saving Device, medium

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Measuring Recording Online Monitoring Regulation Alarming

Constant climate chambers

Transcription:

heatersteam unprecedented precision and reliability

Electric heater humidification Reliable and precise technology for high-tech applications. Steam production is modulated with the highest precision, using any feedwater. Electric heater humidification is the ideal solution to meet the following requirements: use of steam; exceptional relative humidity control performance (±1%); a functional solution that is independent of feedwater characteristics; service continuity. The features of steam humidification make this technique the preferred solution in applications where the priority is hygiene, such as research laboratories or the agriculture and food industry: steam is in fact completely aseptic and does not carry solid particles, an intrinsic quality that is assured without needing to treat the supply water. Nonetheless, the operation of some types of isothermal humidification technology, such as immersed electrodes, is affected considerably by supply water quality: in applications where supply water properties are constant over time or softened water needs to be used, immersed electrode humidification is quite complex, if not impossible. In addition to these limits, which for example prevent the use of demineralized water (useful to drastically reduce maintenance requirements), there are also technological limits in terms of the obtainable relative humidity control precision.

The CAREL solution From water treatment to different steam distribution systems, generated by the most advanced humidifiers on the market. Evolving technology The air humidification technologies currently on the market have made a significant step forwards with the upgraded CAREL heatersteam range of high-precision heater humidifiers, available in models from 4.4 to 176 lb/h (2 to 80 kg/h). The product has been overhauled in every aspect, from its mechanical components to the new electronic controller with graphic interface based on the c.pco platform. The new software functions make heatersteam even more reliable and versatile, while its extensive connectivity allows seamless communication with any BMS system. Steam distribution heatersteam can be used for humidification in the air duct, if used with the stainless steel distributors, or alternatively directly in the room, in combination with CAREL steam blowers. In the most critical applications, for maximum performance the ideal partner for heatersteam is ultimatesam, the high efficiency duct steam distributor: this guarantees complete steam absorption in just a few inches, while at the same time minimizing condensate formation. Using the special wall-mounted nozzle, heatersteam can also be used to generate steam in steam baths. ultimatesam Steam nozzles Steam blower Stainless steel distributor tubes Why use demineralized water? minimum maintenance, as no scale builds up inside the humidifier; compact solution, easy to install.

The heatersteam titanium heatersteam has been completely upgraded from all points of view, with unique hardware and software functions. heatersteam titanium heatersteam titanium, the world s only humidifier with titanium heaters, represents the pinnacle of this family of cutting-edge humidifiers. Versatile and reliable Integrated protection against overheating (unique on the market) and the patented Anti-Foaming System are guarantees of application reliability. The modulating limit probe prevents condensate formation without abrupt interruptions in steam production. ±1% Accuracy around the relative humidity set point Mission critical DNA The reliability of titanium, combined with protection against overheating, makes heatersteam titanium the natural solution for applications in which service continuity is crucial. In particular, the unit can operate on any type of treated water, even extremely aggressive water with a conductivity below 1 µs/cm and softened down to 0 fh: the titanium heating elements are completely resistant to corrosion. Such ultra-pure water is often used in the pharmaceutical industry, and its characteristics mean it may be aggressive to the materials that are normally to construct humidifiers. In addition, the exclusive master/slave Endurance function manages redundancy and rotation, guaranteeing service continuity even during maintenance. Summary table of heatersteam functions Function Titanium Heaters with thermal protection Titanium Thermal shock Master/slave function Endurance Redundancy and rotation Wireless sensors Web server BACnet, Modbus and CAREL protocols USB port tera ready Preheating Thermally insulated cylinder Kevlar scale removal sack Start-up wizard Evaporation cycles before drain to dilute 50 Certification

Operating principle Heat is transferred to the water via the completely immersed heating elements. The solid state relays, managed by the PWM system with built-in humidity or temperature controller, modulate the quantity of heat delivered to the water so as to precisely control steam flow-rate. The heating elements are made from titanium materials that are highly corrosion resistant, and feature an embedded PTC sensor to protect against overheating, for maximum reliability. These features mean heatersteam is independent of supply water quality, while ensuring very precise flow-rate modulation (±1% RH around the set point). CAREL c.phc controller The heatersteam c.phc electronic controller has been designed and developed by CAREL to ensure simple set-up and commissioning and exceptional performance. Important basic functions include: Start-up wizard Simple and fast guided configuration of the main parameters to set up the unit AFS (Anti-Foaming System) Automatic foam management to prevent droplets being delivered in the air. Modulating limit probe To avoid condensate formation in the duct/ahu. Thermal shock Periodical scale removal from the heating elements. Supervision As standard the units come with Modbus, BACnet and CAREL communication protocols available on the BMS serial port, and Modbus, BACnet on the Ethernet port. Preheating Keeps the water in the cylinder at a set temperature for instant delivery of the required steam flow-rate. tera ready This service can be enabled via the Ethernet connection for remote monitoring and control of the unit. Control Features Continuous modulation (with SSR) 0 to 100% Integrated control (probes not included) (RH) or (temp.) External proportional signal Limit probe supported Remote ON/OFF Alarm relay Type of signal (probe or external controller) 0 to 10 V; 0 to 1 V; 2 to 10 V; 0 to 20 ma; 4 to 20 ma Alphanumeric display RS485 interface as standard

heatersteam titanium - features The ideal solution for applications in which reliability and operating flexibility are needed when feedwater characteristics not always under control. fast installation using the wizard; automatic thermal shock; Modbus and BACnet protocols on the BMS and Ethernet ports; USB port; tera ready; preheating for rapid production. More functions The wizard makes installation simple and fast, guiding the user step-bystep through the configuration of the main parameters to get the unit up and running. Controlledtemperature thermal shock cycles, managed in complete safety by the c.phc controller, reduce maintenance requirements and make the unit easier to clean. Built-in USB port The built-in USB port, provides immediate access to several functions: save data log and alarm log to USB flash drive ; copy and paste configuration parameters from one unit to another; update the software directly in the field. A versatile solution The master/slave function can be used to extend installed humidifier capacity without complications. The master/slave function in fact allows one heatersteam to control, via a proportional signal, up to 19 other units, expanding the system capacity up to 3527 lb/h (1600 kg/h). Flexibility heatersteam can operate in conditions in which supply water quality is not controlled or varies over time. Modularity Using the master/slave function, humidification system capacity can be expanded up to 3527 lb/h (1600 kg/h) without complications. Simplified maintenance Thermal shock removes any scale residues from the heating elements, thus reducing maintenance requirements.

The top of the range: extremely high precision, continuous humidity control modulation and unprecedented reliability. Exclusive functions to heatersteam titanium: titanium heaters; built-in web server; master/slave endurance function with redundancy and rotation; wireless sensor reception; Kevlar scale removal sack; thermally insulated cylinder. Accurate and precise heatersteam titanium is the response to applications requiring precise air relative humidity control. When using demineralized water, the CAREL heater humidifier can provide the required humidity with an accuracy of ± 1%. The range of modulation from 0 to 100% of production capacity and the possibility to preheat the water in the cylinder mean heatersteam is always ready to respond to demand for humidity. Perfect integration Modbus and BACnet communication protocols are available as standard on both the BMS and Ethernet serial ports, without requiring optional cards. The CAREL communication protocol is available on the BMS port. Webserver The built-in webserver allows the entire humidification system to be configured and monitored from a PC or tablet connected to the local network, using a simple web browser. Reliability Rotation and redundancy guarantee service continuity even during maintenance. Performance Accuracy of ±1% RH around the set point across a range of continuous modulation from 0 to 100%. Connectivity Monitoring from local network via webserver. Modbus and BACnet protocols allow heatersteam to be perfectly integrated into any system.

heatersteam titanium - applications No limits: heatersteam titanium is the natural solution for the most demanding applications Hospitals (wards and operating theaters) In addition to the hygiene guaranteed by steam, another essential function is the possibility of reduced maintenance requirements - in terms of frequency, complexity and duration - as well as maintenance operations that can be scheduled in advance. ultimatesam heatersteam titanium Museums and libraries Artworks on hygroscopic materials, such as wood and paper, require constant temperature and relative humidity conditions. Swings in these values throughout the day may be quite considerable, as a result of factors such as the weather and the number of visitors. The humidification system must be able to be operate 24 hours a day. heatersteam titanium Steam blower Wireless probe

Cleanrooms and research laboratories Precision, reliability and service continuity are the priorities in cleanrooms, where interruptions to humidity control may place the entire process at risk. Hygiene is guaranteed by steam, which is completely aseptic. Built-in Web server heatersteam titanium Air quality probes

Technical specifications Specifications UR002 UR004 UR006 UR010 UR013 UR020 UR027 UR040 UR053 UR060 UR080 General Rated steam production lb/h (kg/h) 4.4 (2) 9 (4) 13 (6) 22 (10) 29 (13) 44 (20) 60 (27) 88 (40) 116 (53) 132 (60) 176 (80) Power consumption (kw) 1.5 3 4.5 7.5 10 15 22.5 30 40 45.7 60 Power supply (other voltages on request) 208 Vac - 15/+10%, 50/60 Hz three phase 208 Vac -15/+10%, 50/60 Hz single-phase 230 Vac -15/+10%, 50/60 Hz single-phase 230 Vac - 15/+10%, 50/60 Hz three-phase 400 Vac -15/+10%, 50/60 Hz three-phase 460 Vac - 15/+10%, 50/60 Hz three-phase 575 Vac - 15/+10%, 50/60 Hz three-phase Steam connection inches (mm) Ø 1.18 (Ø 30) Ø 1.6 (Ø 40) 2x Ø 1.6 (2x Ø 40) Steam pressure (Pa) 0 to 1500 0 to 2000 Number of heaters 1 1 3 3 3 3 3 6 6 9 9 Operating conditions 33.8 to 104 F (1 to 40 C), 10 to 60% RH non-condensing Storage conditions 14 to 158 C (-10T70 C), 5 to 95% RH non-condensing Ingress protection IP20 Water fill Connection (mm) ¾ G male Temperature limits 33.8 to 104 F (1 to 40 C) Pressure limits (MPa bars) 0.1 to 0.8 1 to 8 Instant flow-rate 0.3 gpm (1.1 l/m) 1 gpm (4 l/m) 2.6 gpm (10 l/m) Total hardness ( fh) 5 to 40 Conductivity limits (µs/cm) 1 to 1500 Water drain Connection Ø 1.6 (Ø 40mm) Ø 2 ( Ø 50 mm) Temperature <212 F (<100 C) Instant flow-rate (l/m) 2.4 gpm (9 l/m) 6 gpm (22,5 l/m) Drain tempering 6 gpm (23 l/m) 14.3 gpm (54.3 l/m) Unit codes U R _ H 0 3 rated instant steam production: 002= 4.4 lb/h (2 kg/h) 004= 9 lb/h (4 kg/h) 006= 13 lb/h (6 kg/h) 010= 22 lb/h (10 kg/h) 013= 29 lb/h (13 kg/h ) 020= 44 lb/h (20 kg/h) 027= 60 lb/h (27 kg/h) 040= 88 lb/h (40 kg/h) 053= 116 lb/h (53 kg/h) 060= 132 lb/h (60 kg/h) 080= 176 lb/h (80 kg/h) power supply: D= 230 Vac 1~ U= 208 Vac 1~ L= 400 Vac 3~ W= 208 Vac 3~ K= 230 Vac 3~ M= 460 Vac 3~ N= 575 Vac 3~ model: 1= titanium Note: not all the combinations of codes are available. CAREL INDUSTRIES 2016 all rights reserved. CAREL INDUSTRIES reserves the right to modify the features of its products without prior notice. +30U0109US - 1.0-26.05.2016 Headquarters ITALY Sales organization Affiliates CAREL INDUSTRIES HQs Via dell Industria, 11 35020 Brugine - Padova (Italy) Tel. (+39) 0499 716611 Fax (+39) 0499 716600 carel@carel.com CAREL Asia - www.carel.com CAREL Australia - www.carel.com.au CAREL Central & Southern Europe - www.carel.com CAREL Deutschland - www.carel.de CAREL China - www.carel-china.com CAREL France - www.carelfrance.fr CAREL Mexicana - www.carel.mx CAREL Middle East - www.carel.com CAREL Nordic - www.carel.com CAREL Russia - www.carelrussia.com CAREL South Africa - www.carelcontrols.co.za CAREL Sud America - www.carel.com.br CAREL Czech & Slovakia - www.carel.com CAREL Ireland - www.carel.com CAREL Japan - www.carel-japan.com CAREL Turkey - www.carel.com.tr CAREL Korea - www.carel.com CAREL Thailand - www.carel.com CAREL Ibérica - www.carel.es CAREL U.K. - www.careluk.co.uk CAREL Italy - www.carel.it CAREL U.S.A. - www.carelusa.com CAREL India - www.carel.in All trademarks hereby referenced are the property of their respective owners. CAREL is a registered trademark of CAREL INDUSTRIES in Italy and/or other countries.