The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Similar documents
Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Guide to Membership Assessments

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Consumer unit replacement in domestic and similar premises

Your specialist partner for total electrical compliance. Electrical Testing

Electrical Contractors Association. presents. The Hidden Perils of Poor Electrical Installation in Domestic Property

Electrical Safety The Hidden Perils

PERIODIC ELECTRICAL TESTING POLICY

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Electrical Safety Policy

Periodic Electrical Testing Policy

The Gas Safety (Installations and Use) Regulations 1998.

Electrical Safety Policy and Management System

Guide to Condition Reports for Domestic Electrical Installations

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

HVCA. Guide to Good Practice. Heating and Ventilating Contractors Association. Mothballing and Re-commissioning of Buildings SFG30

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

Guide to condition reports for domestic electrical installations.

THE SAFE USE OF ELECTRICITY

Loss Prevention Standard

Title: Room-sealed fanned draught flue systems concealed within voids

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Guide to: 17 th Edition Consumer Units

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

COMPLIANCE WITH SAFETY

The new fire regulations - more demands on the employer? The Regulatory Reform (Fire Safety) Order 2005

Code of Practice for In-service Inspection and Testing of Electrical Equipment. 4th Edition

Building Standards Division. Whisky Maturation Warehouses Storage Buildings (Class 1) Automatic Fire Suppression Systems

Cumbria MECHANICAL AND ELECTRICAL INSTALLATION CONTRACTORS. Electrical (Cumbria) Ltd. Electrical Contractors and Design Engineers

Project Briefing Document. Section 3 Electrical Services design guide and specifications

The new Gas Appliances Regulation (EU) 2016/426

Fire prevention and protection

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

A guide to landlords duties: Gas Safety (Installation and Use) Regulations What type of property is covered?

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Fire prevention and protection

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

Loss Prevention Standard

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

Periodic inspection reporting - recommendation codes for domestic and similar electrical installations

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

High Speed Rail (London- West Midlands)

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

The Association for Specialist Fire Protection

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

Alan Wells Technical and Standards Director Certsure LLP trading as NICEIC

SUMET05 Install and connect electrical cables, conductors, wiring systems and equipment

DOMESTIC INSTALLATIONS COMMERCIAL INSTALLATIONS LIGHTING SOLAR PV REPAIRS LANDLORDS SWITCH ON TO SWH ELECTRICAL SOLUTIONS

Panic and Emergency Exit Devices

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

Hardware for Sliding Doors & Folding Doors

Australian/New Zealand Standard

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

dhf General Information Automated Gates Guidance for enforcement bodies

Accredited SIA ACS & ISO 9001:2001 ISO & ISO BSIA Member

Tudor House, Kingsway Business Park Oldfield Road, Hampton, Middlesex, TW12 2HD Phone: +44 (0) Website: EQUALITY ACT 2010

Electrical tests and gas safety checks for church buildings (June 2016) A Church Growth Trust Briefing Paper. Droveway ARCHITECTURE

Controlled Door Closing Devices

Training, Assessment, Consultants for Hazardous & Industrial Areas

Systems of inspecting the existing building and the procedures of auditing engineering plans. M. Mostafa

For your commercial needs, we offer the following services:

The Facilities Manager s Guide to: Electrical Testing, Fire Alarms and Emergency Lighting Regulations. Updated May 2016

Third Party Certification:

FIRA Technical Services. Suzie Radcliffe-Hart Technical Manager

Guide to Gate Safety Legislation & the Machinery Directive

FIRE SAFETY POLICY Revised March 2013

Fire Safety Policy (Communal Areas)

Part P and how it affects you

SUMET09 Maintain electrical systems and equipment (SQA Unit Code- H956 04)

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Fire Safety. A TUC guide for trade union activists

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

HTA ACCREDITATIONS. NADCAP (Heat Treating) 2 AS 9100C 5-6 ISO NADCAP (Heat Treating) 3 AS 9100C 5-6 ISO NADCAP (Heat Treating) 4

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Building Investigation & Testing Services

Design Innovation Engineering Personified

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Fire alarm provisions for alerting the Fire Service

Managing Ex Asset Integrity

Fire Safety Policy Date: 0

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

The management of shared facility HMOs

MULTIKWIK SEWER SYSTEMS MULTIKWIK WC PAN CONNECTORS

Boiler Product Range

Record of Amendments. Version Date Amendment Section/page affected

FIRE SAFETY POLICY June 2014

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

An overview of the main proposals in BS th Edition. Electrical Contractors Association

Where Process Safety meets Machine Safety

Guidance Note. Visual Alarm Devices: Conflict between BS 5839 and EN 54-23

Emergency Voice Communication System (EVCS) Consu ltant s Specific atio n CONTENTS

User Information Sheet 008 : 2010

Transcription:

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition Issued in the interests of safety by

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition Electricity is the most versatile and convenient source of energy known to man. However, it can be potentially dangerous if the system has not been properly designed, installed, operated and maintained. Invariably electrical installations are modified and extended over time to serve additional equipment and requirements. Frequently these additions were not anticipated in the original design and may affect the integrity of the installation. In addition, electrical installation equipment can deteriorate in time because of unforeseen adverse environmental conditions. Therefore it is essential that all electrical installations are inspected, tested and properly maintained in order that they may operate safely. This leaflet is intended to help employers understand the requirements and implications of the legislation and to assist them to meet the obligations which such legislation imposes upon them. THE LAW The Electricity at Work Regulations (EAW) 1989, made under the Health and Safety at Work Act 1974, came into force on April 1st 1990. These regulations require all electrical installations in work places to be designed, constructed and maintained in such a manner as to be safe to use at all times. How can Employers comply with the Law? The Health and Safety Executive booklet The Memorandum of Guidance on the EAW Regulations suggests that in order to comply with the law the condition of the electrical systems should be monitored by regular inspection and testing, and records of the test results should be maintained. Why is it necessary to inspect and test installations? Inspection and testing is necessary to identify any damage to, or defects in, an installation which may give rise to danger, so as to ensure the safety of persons and livestock from the effects of electric shock and burns, and property from the effects of fire and heat, arising from a defective electrical installation. In other words, to ensure that it is SAFE TO USE. Who is responsible? EAW Regulation 3 It is the responsibility of the employer and in some instances a self employed person, to ensure that electrical systems are safe. Employees have a duty to co-operate with the employer in this respect. "Employer" in this sense includes those persons charged with the management of the work place. What premises do the regulations cover? All premises and places where people work, for example: Public buildings - schools hospitals, sports and leisure centres, museums, cinemas, theatres, football, cricket and athletic grounds; Residential - residential homes for the elderly, hotels and guest houses; Industrial - factories, farms and construction sites; Commercial - offices, shops and warehouses. Who should carry out inspection and testing of electrical installations? EAW Regulation 16. IEE Wiring Regulations Inspection and Testing shall be carried out by competent persons who shall have sufficient technical knowledge and experience appropriate to the type of installation, and an understanding of the test methods and requirements in order to prevent danger or injury. Since the person must make judgements on the appropriate levels and frequency of testing required, he must have an understanding of the use of the premises concerned, the operating environment and any relevant safety standards or licensing requirements that may be applicable to the premises. The correct instruments must also be used. How frequently should electrical installations be periodically inspected and tested? Public buildings, sports and leisure facilities - every year, or as required by the Local Authority conditions of licence; Industrial and agricultural - 3 years; Commercial, educational and residential (not domestic) - 5 years; Construction sites - 3 months, or as frequent as the testing engineer considers necessary according to the exposure of the installation to deterioration or damage.

What needs to be inspected? The inspection should comprise a careful scrutiny of the installation to ascertain if there has been any deterioration or damage to the installed equipment, or if there are any installation defects that may give rise to danger. Cables, trunking and conduits, switchgear, distribution boards and protective devices, equipment, lighting fittings and accessories, all need inspecting for deterioration; due to age, the working environment, or the affects of heat generated by overloading or loose connections, and for electrical and mechanical damage. What needs testing? EARTHING: The earthing arrangements to ensure that the installation and all metal parts are adequately connected to earth and that all devices for protection will operate within prescribed times when a fault occurs. POLARITY: to ensure that the cables and equipment are not live when switches are in the off position. INSULATION: The resistance of the insulation of cables and equipment to ensure that there are no dangerous leakage currents which may be the cause of a fire or a circuit failure. RCDs: Residual current devices need to have specific tests applied to them to ensure that they will operate and disconnect the circuit within the specified time when required to do so. these devices are installed as supplementary protection against electric shock if a person should touch a live cable or metal that is live because of a fault. Important note: It is essential that RCDs are "tested" frequently by the user of the installation so as to ensure that the operating mechanism will move freely and rapidly when required. How should test results be documented? EAW Regulation 4(2) It is advisable to have a test results schedule for every distribution board and control panel. The schedule should record information about the supply to the distribution board as well as details of the final circuits. Earth Loop Impedance and Insulation Resistance values should be recorded for every circuit. The test records should be retained for comparison with future test results. What about a certificate of safety? There is no requirement for certification but BS7671; 2008 Requirements for Electrical Installations, IEE Wiring Regulations 17th Edition require a "Report to be given by the person carrying out the Inspection and Testing, to the person ordering the work". The report should contain a list of any damage to and defects in the installation, and noncompliance with the Regulations, which may give rise to danger. The report should also detail the limitations of the Inspection and. Testing. Where can I get further information? The answers given above are intended for guidance only and you are strongly advised to refer to the relevant legislation and safety standards to assess your obligations. For more information, the following publications are particularly recommended: The Health and Safety at Work Act of 1974 HSE Guidance Note HS(R)25 - Memorandum of Guidance on the Electricity at Work Regulations 1989 HSE Books, PO Box 1999, Sudbury, Suffolk CO10 6FS. Tel: 01787 881165 www.hsebook.co.uk BS7671 2008 Requirements for Electrical Installations, IEE Wiring Regulations 17th Edition. Inspection and Testing Guidance Notes 3. Contact: The Institution of Engineering and Technology, Michael Faraday House, Six Hills Way, Stevenage, Herts SG1 2AY. www.theiet.org How can ECA members help? The Regulations are very complex and imply that the testing programme from the initial assessment of procedures through to the final report is carried out by technically competent and experienced people. ECA members are capable of carrying our this work for you and thus help you to comply with the EAW Regulations. They will be willing to discuss your installations and advise t of the procedures you should adopt. A copy of the register of ECA members is available on request. ECA members offer a recognised Inspection and Testing Contract and a Maintenance contract which have been registered with the office of Fair Trading. They can also offer and advise on a planned maintenance programme to ensure the efficiency and safety of all electrical systems and equipment.

The Premier Association of Electrical Installation Engineers The Electrical Contractor's Association represents the interests of companies in England, Wales and Northern Ireland designing and installing the electrical engineering services needed in homes, schools, hospitals, factories, industrial plant and commercial premises. These installations include traditional power and lighting outlets together with complex high technology control, security and data communications system for automated offices, industrial plant and environmental services. The ECA was founded in 1901. It has over 3,000 member firms which range from local employers with only a few operatives to national multiservice companies with many branches employing thousands - many operating worldwide. ECA members have a collective annual turnover in excess of 3 billions which represents 80% of all the electrical installation engineering work undertaken in England, Wales and Ireland. Its members employ over 30,000 operatives and support 8,000 apprentices in their craft training. ECA Ensuring Installation Safety and Customer Satisfaction The aim of the ECA is to ensure that electrical installation work is undertaken by qualified people to high standards of quality and safety and to terms which are equitable to the client and installer. This relates to the technical and commercial abilities of the contractor. Members of the ECA must have been operating successfully for at least one year before joining the Association. In addition: Potential members are inspected and assessed to ensure that they operate sound business practices. The installation work of a potential member is inspected rigorously to ensure technical compliance with relevant national standards across all aspects - design, procedures, installation, inspection, test and documentation. Subsequently members are inspected on a regular basis as part of the ECA's Periodic Technical Assessment Scheme to ensure that satisfactory standards are maintained. For work falling within its scope all members work to BS 7671: 2008 Requirements for Electrical Installations (The Institution of Electrical Engineers (IEE) Wiring Regulations). All members employ qualified electricians, registered with the Joint Industry Board for the Electrical Contracting Industry (JIB). All members work to a published Code of Fair Trading duly registered with the UK Office of Fair Trading to ensure an equitable exchange with their clients. Copies of the Code are available on request for Members of the Association. ECA Guarantee The ECA Guarantee of Work Scheme replaced the ECA Warranty Scheme, on 1 January 2009. The Warranty, where used, will continue to cover contracts signed before 1 January 2009 in accordance with scheme s terms and conditions. The Guarantee of Work Scheme guarantees to customers of ECA members that subject to terms and conditions, electrical installation work failing to comply with relevant British Standards will be rectified. Products and materials selected by the member must conform to relevant Sale of Goods Legislation. The Guarantee is compliant with TrustMark and Part P of the Building Regulations. It is effective for claims notified within six years of completion of the work and is subject to a maximum limit of 50,000 (including VAT) and 100,000 (including VAT) for multiple contracts for the same customer in any one year. ECA Bond The ECA Bond, which is underwritten by an insurer provides the following cover: The Bond, subject to the terms and conditions of the scheme, provides the Claimant with an assurance that if the member's employment is determined for a Specified Reason, such as the insolvency of the member, the additional cost of completion will be met by the Insurer to a maximum limit of 50,000 or 10% of the members contract value shown on its certificate. The benefits of the Bond are available to all clients on all contracts using 'Approved Forms'. Certificates Certificates are issued to each ECA member company and the contract specifier or client is recommended to request copies from the contractor to verify their validity in support of the ECA Guarantee and ECA Bond schemes. ECA Supporting and Encouraging Professionalism in the Industry The ECA strives to help its members provide their customers with the best possible service. It maintains permanent service departments which provide qualified assistance, information and advice on employee relations, technical, commercial and legal matters. In addition it operates over 50 business training courses to keep its members updated on new practices and technologies. These include courses on inspection and Test, and Portable Appliance Testing. A network of ECA Regional Offices maintains an efficient local contact structure much appreciated by clients and members alike. Electrical Contractors Association, ESCA House, 34 Palace Court, London, W2 4HY Tel 020 7313 4800 Fax 020 7221 7344 Email info@eca.co.uk www.eca.co.uk P15750907 The ECA Logo is a Registered Collective Mark. Information presented is accurate at time of printing.

SJD Associates Ltd Unit 6 Mount Avenue Mount Farm Milton Keynes MK1 1LS Web: www.sjd-electrical.co.uk Email: ruthdevine@sjd-electrical.co.uk Phone: 01908 632488 The ECA Logo is a Registered Collective Mark. Information presented is accurate at time of printing. Electrical Contractors Association ESCA House, 34 Palace Court, London, W2 4HY Tel 020 7313 4800 Fax 020 7221 7344 Email info@eca.co.uk www.eca.co.uk