Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Similar documents
Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Airflow Sensors Line Guide

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Airflow Sensors Line Guide

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

FSS-SMT Series. Low Profile Force Sensor

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Installation Instructions for the

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Issue C CAUTION

TruStability Board Mount Pressure Sensors

WARNING MISUSE OF DOCUMENTATION

HIH-5030/5031 Series Low Voltage Humidity Sensors

Selecting Honeywell Board Mount Pressure Sensors

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Micropower Omnipolar Digital Hall-Effect Sensor ICs

FEATURES AND BENEFITS

Application Note Sensors and Flexible Heaters in Ventilator Applications

HIH-4000 Series Humidity Sensors

Honeywell Zephyr TM Digital Airflow Sensors HAF Series High Accuracy: 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM, 300 SLPM

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Sensors in Ventilators

Honeywell Zephyr TM Digital Airflow Sensors: HAF Series High Accuracy 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM or 300 SLPM.

HIH-4602-L Series Humidity Sensors

Application Note Sensors and Flexible Heaters in Anesthesia Machine Applications

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Potential Applications

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Force Sensors Line Guide

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet


HIH-4030/31 Series Humidity Sensors

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Installation Instructions for the

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Quadrature Speed and Direction Sensors

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

HIH-4010/4020/4021 Series Humidity Sensors

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

HOA6480 Series Barcode Sensor Infrared Products

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH V15W Series Watertight Miniature Switches

V-Basic Standard V15 Series

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Board Mount Pressure Sensors Line Guide

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

HIH-4602 A & C Series.

Heavy Duty Pressure Transducers

Wireless Panel-Mount Monitor

Linear Current Sensors

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

Installation Instructions for the 600 Series Optical Encoders

MSP100 Pressure Transducer

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

AMR 4-Pin Quadrature Sensor Integrated Circuit

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH GLL Series

Sensors and Switches in Commercial Traction Elevators

Application Note Sensors and Flexible Heaters in Sleep Apnea Machines

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

MS4525 SPECIFICATIONS

Intrinsically Safe Transmitters, Option Code 2n

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH GSX Series

High Temperature Industrial VRS Magnetic Speed Sensors

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU) Issue 2. Datasheet

Transcription:

Short Port Fastener Mount Honeywell Zephyr Digital Airflow Sensors: ±50 SCCM to ±750 SCCM Long Port Fastener Mount Short Port Snap Mount DESCRIPTION Honeywell Zephyr HAF Series sensors provide a digital interface for reading airflow over specified full-scale flow and compensated temperature ranges. The thermally isolated heater and temperature sensing elements help these sensors provide a fast response to air or gas flow. Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are available at ±50, ±100, ±200, ±400 or ±750 SCCM. Custom flow ranges are also available. The sensors are fully calibrated and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC). The HAF Series is compensated over the temperature range of 0 C to 50 C [32 F to 122 F] and operates across a temperature range of -20 C to 70 C [-4 F to 158 F]. The state-of-the-art ASIC-based compensation provides digital (I 2 C) outputs with a response time of 1 ms. FEATURES AND BENEFITS ( = competitive differentiator) Total Error Band (TEB) as low as ±0.25 %FSS allows for precise airflow measurement, often ideal for demanding application with high accuracy requirements Fast response time allows a customer's application to respond quickly to airflow change, important in critical medical (e.g., anesthesia) and industrial (e.g., fume hood) applications Wide range of airflows: Zephyr measures mass flow at standard flow ranges of ±50, ±100, ±200, ±400 or ±750 SCCM, or custom flow ranges, increasing the options for integrating the sensor into the application Customizable flow ranges and configurable package styles meet specific end-user needs Full calibration and temperature compensation typically allow customer to remove additional components associated with signal conditioning from the PCB, reducing PCB size as well as costs often associated with those components (e.g., acquisition, inventory, assembly) High sensitivity at very low flows provides for faster response time at the onset or cessation of flow Linear output provides more intuitive sensor signal than the raw output of basic airflow sensors, which can help reduce production costs, design, and implementation time High stability reduces errors due to thermal effects and null shift to provide accurate readings over time, often eliminating need for system calibration after PCB mount and periodically over time These sensors operate on the heat transfer principle to measure mass airflow. They consist of a microbridge Microelectronic and Microelectromechanical System (MEMS) with temperature-sensitive resistors deposited with thin films of platinum and silicon nitride. The MEMS sensing die is located in a precise and carefully designed airflow channel to provide repeatable response to flow. Zephyr sensors provide the customer with enhanced reliability, high accuracy, repeatable measurements and the ability to customize sensor options to meet many specific application needs. The combination of rugged housings with a stable substrate makes these products extremely robust. They are designed and manufactured according to ISO 9001 standards. Low pressure drop typically improves patient comfort in medical applications, and reduces noise and system wear on other components such as motors and pumps High 12-bit resolution increases ability to sense small airflow changes, allowing customers to more precisely control their application Low 3.3 Vdc operating voltage option and low power consumption allow for use in battery-driven and other portable applications ASIC-based I 2 C digital output compatibility eases integration to microprocessors or microcontrollers, reducing PCB complexity and component count Insensitivity to mounting orientation allows customer to position sensor in most optimal point in the system, eliminating concern for positional effects Insensitivity to altitude eliminates customer-implemented altitude adjustments in the system, easing integration and reducing production costs by not having to purchase additional sensors for altitude adjustments Small size occupies less space on PCB, allowing easier fit and potentially reducing production costs; PCB size may also be reduced for easier fit into space-constrained applications RoHS-compliant materials meet Directive 2002/95/EC

Honeywell Zephyr Digital Airflow Sensors POTENTIAL APPLICATIONS Medical Anesthesia delivery machines Ventricular assist devices (heart pumps) Hospital diagnostics (spectrometry, gas chromatography) Nebulizers Oxygen concentrators Patient monitoring systems (respiratory monitoring) Sleep apnea machines Spirometers Ventilators Laparoscopy Industrial Air-to-fuel ratio Analytical instrumentation (spectrometry, chromatography) Fuel cells Gas leak detection VAV system on HVAC systems Gas meters HVAC filters Table 1: Absolute Maximum Ratings 1 Characteristic Parameter CAUTION Supply voltage -0.3 Vdc to 6.0 Vdc IMPROPER USE Voltage on output pin -0.3 V to Vsupply Do not use these products to sense liquid flow. Storage temperature range -40 C to 125 C [-40 F to 257 F] Failure to comply with these instructions Maximum flow change 5.0 SLPM/s may result in product damage. Maximum common mode pressure 25 psi at 25 C [77 F] Maximum flow 10 SLPM Note 1: Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings. Table 2: Operating Characteristics Characteristic Parameter Note Supply voltage 3.3 Vdc ±10%; 5.0 Vdc ±10% Supply current 16 ma max. Power: 3.3 Vdc 5.0 Vdc 23 mw typ. 38 mw typ. Operating temperature range -20 C to 70 C [-4 F to 158 F] Compensated temperature range 0 C to 50 C [32 F to 122 F] 1 Accuracy See Figure 1 2, 4 Total error band (TEB) See Figure 2 3, 4 Null accuracy ±0.02% FSS 4, 10 Response time 1 ms typ. 5 Resolution 12 bit min. Start up time 17 ms 6 Warm up time 30 ms 7 Calibration media gaseous nitrogen 8 Bus standards I 2 C, fast mode (up to 400 khz) 9 Null stability ±0.01% FSS maximum deviation from null output after 1000 hours at 25 C Reverse polarity protection no Notes: 1. Custom and extended compensated temperature ranges are possible. Contact Honeywell for details. 2. Accuracy is the maximum deviation from the nominal digital output over the compensated flow range at a reference temperature of 25 C. Errors include offset, span, non-linearity, hysteresis and non-repeatability (see Figure 1 for the Accuracy Error Band vs Flow). 3. Total error band includes all errors over the compensated flow range including all effects due to temperature over the compensated temperature range (see Figure 2 for the Total Error Band). 4. Full Scale Span (FSS) is the algebraic difference between the digital output at the forward Full Scale (FS) flow and the digital output at the reverse FS flow. Forward flow is defined as flow from P1 to P2 as shown in Figure 8. The references to mass flow (SCCM) refer to gas flows at the standard conditions of 0 C and atmospheric pressure 760 (101.3 kpa). 5. Response time: time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer may be affected by the pneumatic interface). 6. Start-up time: time to first valid reading of serial number proceeding streaming 14-bit flow measurements. 7. Warm-up time: time to the first valid flow measurement after power is applied. 8. Default calibration media is dry nitrogen gas. Please contact Honeywell for other calibration options. 9. Refer to the Technical Note I 2 C Communications with Honeywell Digital Airflow Sensors for I 2 C protocol information. 10. Null accuracy is the maximum deviation in output at 0 SCCM from the ideal transfer function over the compensated temperature range. This includes offset errors, thermal airflow hysteresis and repeatability errors.

±750 SCCM ±750 SCCM ±400 SCCM ±400 SCCM ±200 SCCM ±200 SCCM ±100 SCCM ±100 SCCM ±50 SCCM ±50 SCCM ±50 SCCM to ±750 SCCM Figure 1. Accuracy Error Band for Bidirectional Forward Flow Optimized Figure 2. Total Error Band for Bidirectional Forward Flow Optimized Error (%FSS) See table for null accuracy Error (%FSS) See table for null accuracy Airflow (SCCM) Airflow (SCCM) Applied Flow (SCCM) Accuracy Error (%FSS) -50 to -16.7 ±0.06 x flow (±6% reading) Applied Flow (SCCM) Total Error Band (%FSS) -50 to -14.3 ±0.07 x flow (±7% reading) -16.7 to 0 ±1-14.3 to 0 ±1 0 ±0.08 0 ±0.08 0 to 20 ±1 0 to 14.3 ±1 20 to 50 ±0.05 x flow (±5% reading) 14.3 to 50 ±0.07 x flow (±7% reading) -100 to -14.3 ±0.035 x flow (±7% reading) -100 to -14.3 ±0.035 x flow (±7% reading) -14.3 to 0 ±0.5-14.3 to 0 ±0.5 0 ±0.04 0 ±0.04 0 to 20 ±0.5 0 to 16.7 ±0.5 20 to 100 ±0.025 x flow (±5% reading) 16.7 to 100 ±0.03 x flow (±6% reading) -200 to -11.1 ±0.0225 x flow (±9% reading) -200 to -11.1 ±0.0225 x flow (±9% reading) -11.1 to 0 ±0.25-11.1 to 0 ±0.25 0 ±0.02 0 ±0.02 0 to 40 ±0.25 0 to 22.2 ±0.25 40 to 200 ±0.006 x flow (±2.5% reading) 22.2 to 200 ±0.01125 x flow (±4.5% reading) -400 to -26.7 ±0.0112 x flow (±9% reading) -400 to -32 ±0.0125 x flow (±10% reading) -26.7 to 0 ±0.3-32 to 0 ±0.4 0 ±0.02 0 ±0.02 0 to 68.6 ±0.3 0 to 71.1 ±0.4 68.6 to 400 ±0.0044 x flow (±3.5% reading) 71.1 to 400 ±0.00625 x flow (±4.5% reading) -750 to -31.3 ±0.008 x flow (±12% reading) -750 to -31.25 ±0.008 x flow (±12% reading) -31.3 to 0 ±0.25-31.25 to 0 ±0.25 0 ±0.02 0 ±0.02 0 to 68.2 ±0.25 0 to 50 ±0.25 68.2 to 750 ±0.0036 x flow (±5.5% reading) 50 to 750 ±0.005 x flow (±7.5% reading)

Honeywell Zephyr Digital Airflow Sensors Table 3. Environmental Characteristics Characteristic Humidity Shock Vibration ESD Radiated immunity Parameter 0% to 95% RH, non-condensing 100 g, 11 ms 15 g at 20 Hz to 2000 Hz Class 3B per MIL-STD 883G Level 3 from (80 MHz to 1000 MHz) per spec IEC61000-4-3 Table 4. Wetted Materials Characteristic Covers Substrate Adhesives Electronic components Compliance Parameter high temperature polymer PCB epoxy silicon, gold RoHS, WEEE Table 5. Recommended Mounting and Implementation Characteristic Parameter CAUTION Mounting screw size 5-40 Mounting screw torque Tubing for long port style 0.68 N m [6 in-lb] 70 durometer, size 0.125 inch inside diameter, 0.250 inch outside diameter silicone tubing O-ring for short port style AS568A, Size 7, Silicone, Shore A 70 O-ring for long port style AS568A, Size 10, Silicone, Shore A 70 Filter recommendation 5-micron filter upstream of the sensor LARGE PARTICULATE DAMAGE Use a 5-micron filter upstream of the sensor to keep media flow through the sensor free of condensing moisture and particulates. Large, high-velocity particles or conductive particles may damage the sensing element. Failure to comply with these instructions may result in product damage. Figure 3. Nominal Digital Output Ideal Transfer Function Digital Output Code = 16384 * [0.5 + 0.4 * (Flow Applied/Full Scale Flow)] Flow Applied = Full Scale Flow * [(Digital Output Code/16384) - 0.5]/0.4

±50 SCCM to ±750 SCCM Figure 4. Long Port Style Flow vs Pressure Pressure Drop (inches H2O) 0.12 0.06 0-0.06-0.12-750 -600-450 -300-150 0 150 300 450 600 750 Flow (SCCM) Flow Typ. Pressure Drop for Long Port (SCCM) inh 2O mbar -750-0.1011-0.2517-550 -0.0602-0.1499-400 -0.0358-0.0891-300 -0.0232-0.0578-200 -0.0129-0.0321-100 -0.0046-0.0114-50 -0.0014-0.0035-20 -0.0003-0.0007 0 0.0000 0.0000 20 0.0003 0.0007 50 0.0014 0.0035 100 0.0046 0.0014 200 0.0129 0.0321 300 0.0232 0.0578 400 0.0358 0.0891 550 0.0602 0.1499 750 0.1011 0.2517 Figure 5. Short Port Style Flow vs Pressure Pressure Drop (inches H2O) 0.6 0.4 0.2 0-0.2-0.4-0.6-200 -150-100 -50 0 50 100 150 Flow (SCCM) 200 Flow Typ. Pressure Drop for Short Port (SCCM) inh 2O mbar -200-0.470-1.1707-150 -0.284-0.7074-100 -0.143-0.3562-50 -0.045-0.1120 0 0.000 0.0000 50 0.048 0.1196 100 0.139 0.3462 150 0.287 0.7149 200 0.452 1.2589 Figure 6. Wave Solder Profile Temperature ( C) 300 250 200 150 100 50 Max. temp. = 243 C Max. temp. = 205 C 0 0 20 40 60 80 100 Time (s) Housing temp. (top of device) Pin temp. (bottom of device)

Honeywell Zephyr Digital Airflow Sensors Digital Interface For additional details on the use of Zephyr with digital output see the Technical Note I 2 C Communications with Honeywell Digital Airflow Sensors. The sensor uses the I 2 C standard for digital communication with a slave address specified in the Nomenclature and Order Guide in Figure 8. Following sensor power-up, each of the first two read sequences shown in Figure 7 will respond with 2 bytes of the unique 4-byte Serial Number. The first read after power-up will respond with the two most significant bytes of the Serial Number, while the second read will respond with the two least significant bytes of the Serial Number. For reliable performance, allow sensor to be powered for the sensor startup time before performing the first read, then allow a 10 ms command response time before performing the second read. Figure 7. Sensor I 2 C Read and Write Sequences After the power-up read sequence described above, the sensor will respond to each I 2 C read request with a 16-bit (2 byte) digital flow reading. Read requests taken faster than the Response Time (1 ms) are not guaranteed to return fresh data. The first two bits of each flow reading will be 00, while non-flow responses (such as error and status codes) will begin with 11. The maximum sink current on SCL or SDA is 2 ma. Therefore, if the pull-up resistors are biased by V DD and if V DD reaches the maximum supply voltage of 6 V, then the pull-up resistors for SCL and SDA must be greater than 3.0 kω to limit the sink current to 2 ma. The typical value for SCL and SDA pull-up resistors is 4.7 kω (this value depends on the bus capacitance and the bus speed).

±50 SCCM to ±750 SCCM Figure 8. Nomenclature and Order Guide Notes: 1. The Long Port Port Style with the Snap Mount Housing Style is not a valid configuration. 2. The 200 SCCM Flow Range is available in the long and short Port Styles. Customer-specific Requirements Apart from the general configuration required, other customer-specific requirements are also possible. Please contact Honeywell.

Honeywell Zephyr Digital Airflow Sensors Figure 9. Mounting Dimensions (For reference only: mm [in]). Additional port and housing styles available. Long Port Style, Fastener Mount Short Port Style, Snap Mount 22,00 [0.87] Honeywell Zephyr MODEL NUMBER LOT CODE DIA. 2,30 [0.09] MODEL NUMBER LOT CODE HAFBLFXXXXXXXXX 0x123456789 Honeywell Zephyr HAFBSSXXXXXXXXX TERMINAL SIDE 0x123456789 2X DIA. 3,40 [0.13] 3,0 [0.12] 2,00 TYP. [0.079] 36,00 [1.42] 6,35 [0.25] 12,70 [0.50] 1,00 [0.04] 28,80 [1.13] AIRFLOW DIRECTION, PORT SIDE 3,50 [0.14] 10,3 [0.40] 10,00 [0.39] 6,50 [0.26] 19,90 [0.78] 4X DIA. 0,812 [0.032] 2X PORTS 18,00 [0.71] 2X DIA. 5,35 [0.21] 36,00 [1.42] SENSOR FOOTPRINT VIEWED FROM TERMINAL SIDE 2X DIA. 3,40 [0.134] 3,3 [0.13] TERMINAL SIDE 26,00 [1.02] 2,00 TYP. [0.079] 1,00 [0.04] 6,35 [0.25] 12,70 [0.50] 28,80 [1.13] AIRFLOW DIRECTION, PORT SIDE 4,80 [0.19] 1,80 [0.071] 10,3 [0.40] 19,90 [0.78] 2,50 [0.10] 4X DIA. 0,812 [0.032] 2X PORTS 6,50 [0.26] 10,40 [0.41] 22,0 [0.866] 4,60 [0.18] 3,00 [0.12] 12,8 [0.50] 26,00 [1.024] SENSOR FOOTPRINT VIEWED FROM TERMINAL SIDE 2X DIA. 2,2 [0.086] THRU HOLES FOR MOUNTING 3,80 [0.150] 0,65 [0.026] 4,00 [0.157] 2X 2,50 [0.098] 2X Short Port Style, Fastener Mount 3,0 [0.12] 2,00 TYP. [0.079] Honeywell Zephyr HAFBSFXXXXXXXXX 0x123456789 TERMINAL SIDE 1,00 [0.04] MODEL NUMBER LOT CODE 3,50 [0.14] Pinout (digital function) 1 = SCL 2 = Vsupply 3 = ground 4 = SDA 10,3 [0.40] 2,50 [0.10] 2X DIA. 4,00 [0.16] 6,50 [0.26] 19,90 [0.78] 18,00 [0.71] 36,00 [1.42] 2X DIA. 3,40 [0.13] 36,00 [1.42] 6,35 [0.25] 12,70 [0.50] 28,80 [1.13] AIRFLOW DIRECTION, PORT SIDE 4X DIA. 0,812 [0.032] 2X PORTS SENSOR FOOTPRINT VIEWED FROM TERMINAL SIDE 2X DIA. 3,40 [0.134]

WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: sensing.honeywell.com Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 sensing.honeywell.com 008178-7-EN December 2012 2012 Honeywell International Inc. All rights reserved.